839 resultados para stent coronariano


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We sought to determine a potential interaction between statins and antiplatelet therapy with aspirin and clopidogrel. Previous laboratory studies have shown a possible drug-drug interaction of statins metabolized by cytochrome P450 3A4 and clopidogrel (prodrug metabolized by cytochrome P450 3A4), resulting in an impaired inhibitory effect of clopidogrel on platelet aggregation. However, conclusive prospective data assessing this potentially relevant interaction are lacking. In 73 patients, 23 with previous coronary stent thrombosis (ST) (ST group) and 50 without coronary ST (control group), platelet aggregation was measured 3 times in monthly intervals using light transmission aggregometry (adenosine diphosphate [ADP] and arachidonic acid induction). Measurements were carried out with aspirin monotherapy (100 mg/day), dual antiplatelet therapy with aspirin plus clopidogrel (75 mg/day), and additional treatment of 20 mg/day of atorvastatin or 40 mg/day of pravastatin. ADP (5 and 20 micromol)-induced platelet aggregation was significantly decreased with clopidogrel (p <0.001) but remained stable under additional treatment with atorvastatin or pravastatin in the 2 groups. Patients with previous ST showed a higher ADP-induced aggregation level than control subjects. This difference was not influenced by clopidogrel or statin treatment. In conclusion, patients with previous ST show a higher aggregation level than control subjects independent of statin treatment. Atorvastatin and pravastatin do not interfere with the antiaggregatory effect of aspirin and clopidogrel. In conclusion, drug-drug interaction between dual antiplatelet therapy and atorvastatin or pravastatin seems not to be associated with ST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Restenosis has been the principal limitation of bare metal stents. Based upon the presumption that platelet and inflammatory cell recruitment initiate neointimal proliferation, we explored a novel polymer coating that reduces cell-stent interactions. The purpose of the present study was to investigate the effect of poly(L-lysine)-graft-poly(ethyleneglycol) (PLL-g-PEG) adsorbed to stent surfaces to reduce neointimal hyperplasia in the porcine restenosis model. METHODS AND RESULTS: Seven animals were instrumented each with 2 stainless steel stents (15 mm length, 2.5-3.5 mm diameter), randomly implanted in 1 major epicardial coronary artery. One stent was dip-coated with PLL-g-PEG, whereas the other stent served as the uncoated control stent. All animals were sacrificed after 6 weeks for histological examination. Neointimal hyperplasia was significantly less (-51%) in the PLL-g-PEG-coated stents (1.15 +/- 0.59 mm2) than in the uncoated control stents (2.33 +/- 1.01 mm2; p < 0.001). Conversely, lumen size was larger in the PLL-g-PEG-coated stents (2.91 +/- 1.17 mm2) than in the uncoated stents (2.04 +/- 0.64 mm2; p < 0.001). High magnification histomorphologic examination revealed no signs of inflammation or thrombus formation in either stent group. CONCLUSIONS: Polymeric steric stabilization of stents with PLL-g-PEG significantly reduces neointimal hyperplasia in the porcine restenosis model. Reduction of cell-stent interactions mediated by PLL-g-PEG appear to improve biocompatibility of stainless steel stents without evidence of adverse inflammatory or prothrombotic effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare coronary collateral function in patients after bare-metal stent (BMS) or drug-eluting stent (DES) implantation. BACKGROUND: Drug-eluting stents have an inhibitory effect on the production of cytokines, chemotactic proteins, and growth factors, and may therefore negatively affect coronary collateral growth. METHODS: A total of 120 patients with long-term stable coronary artery disease (CAD) after stent implantation were included. Both the BMS group and the DES group comprised 60 patients matched for in-stent stenosis severity of the vessel undergoing collateral flow index (CFI) measurement at follow-up and for the duration of follow-up. The primary end point of the investigation was invasively determined coronary collateral function 6 months after stent implantation. Collateral function was assessed by simultaneous aortic, coronary wedge, and central venous pressure measurements (yielding CFI) and by intracoronary electrocardiogram during balloon occlusion. RESULTS: There were no differences between the groups regarding age, gender, body mass index, frequency of cardiovascular risk factors, use of cardiovascular drugs, severity of CAD, or site of coronary artery stenoses. Despite equal in-stent stenosis severity (46 +/- 34% and 45 +/- 36%) and equal follow-up duration (6.2 +/- 10 months and 6.5 +/- 5.4 months), CFI was diminished in the DES versus BMS group (0.154 +/- 0.097 vs. 0.224 +/- 0.142; p = 0.0049), and the rate of collaterals insufficient to prevent ischemia during occlusion (intracoronary electrocardiographic ST-segment elevation > or =0.1 mV) was higher with 50 of 60 patients in the DES group and 33 of 60 patients in the BMS group (p = 0.001). CONCLUSIONS: Collateral function long after coronary stenting is impaired with DES (sirolimus and paclitaxel) when compared with BMS. Considering the protective nature of collateral vessels, this could lead to more serious cardiac events in the presence of an abrupt coronary occlusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the case of 77-year-old woman who underwent five coronary angiographies in 9 months due to in-stent re-stenosis of Cypher-Stents, and who finally required coronary artery bypass grafting surgery. Preoperative investigations revealed a significant internal carotid stenosis, which was due to a fractured and embolized Cypher-Stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the primary success and short-term patency associated with a new 4-F sheath-compatible self-expanding nitinol stent after failed conventional angioplasty of distal popliteal and infrapopliteal lesions in severe lifestyle-limiting claudication (LLC) and chronic critical limb ischemia (CLI). MATERIALS AND METHODS: Between May 2003 and July 2005, 35 patients with Rutherford category 3-5 disease (16 patients with CLI, 19 patients with LLC) underwent percutaneous transluminal angioplasty (PTA) and stent implantation. Indications for stent placement were residual stenosis, flow-limiting dissections, or elastic recoil after PTA. Before and after the intervention and during the 6-month follow-up, clinical investigation, color-flow and duplex Doppler ultrasonography, and digital subtraction angiography were performed. Technical success, primary patency at 6 months, clinical improvement as defined by Rutherford with clinical and hemodynamic measures, and complications were evaluated. RESULTS: A total of 22 patients underwent distal popliteal artery stent placement and 13 underwent tibioperoneal artery stent placement. Stent implantation was successfully performed in all patients. After stent placement, the primary cumulative patency rate for the study group at 6 months was 82%. The mean resting ankle-brachial index at baseline was 0.50 +/- 0.16 and significantly increased to 0.90 +/- 0.17 at 12-24 hours after intervention and 0.82 +/- 0.24 at latest follow-up (P < .001 for both). The sustained clinical improvement rate was 80% at the 6-month follow-up. The 6-month limb salvage rate regarding major amputation was 100%. The rate of major complications was 17%. CONCLUSIONS: Infrapopliteal application of the new nitinol stent is a safe, feasible, and effective method with good short-term patency rate in the treatment of severe LLC and chronic CLI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to evaluate the diagnostic accuracy of coronary binary in-stent restenosis (ISR) with angiography using 64-slice multislice computed tomography coronary angiography (CTCA) compared with invasive coronary angiography (ICA). BACKGROUND: A noninvasive detection of ISR would result in an easier and safer way to conduct patient follow-up. METHODS: We performed CTCA in 81 patients after stent implantation, and 125 stented lesions were scanned. Two sets of images were reconstructed with different types of convolution kernels. On CTCA, neointimal proliferation was visually evaluated according to luminal contrast attenuation inside the stent. Lesions were graded as follows: grade 1, none or slight neointimal proliferation; grade 2, neointimal proliferation with no significant stenosis (<50%); grade 3, neointimal proliferation with moderate stenosis (> or =50%); and grade 4, neointimal proliferation with severe stenosis (> or =75%). Grades 3 and 4 were considered binary ISR. The diagnostic accuracy of CTCA compared with ICA was evaluated. RESULTS: By ICA, 24 ISRs were diagnosed. Sensitivity, specificity, positive predictive value, and negative predictive value were 92%, 81%, 54%, and 98% for the overall population, whereas values were 91%, 93%, 77%, and 98% when excluding unassessable segments (15 segments, 12%). For assessable segments, CTCA correctly diagnosed 20 of the 22 ISRs detected by ICA. Six lesions without ISR were overestimated as ISR by CTCA. As the grade of neointimal proliferation by CTCA increases, the median value of percent diameter stenosis increased linearly. CONCLUSIONS: Binary ISR can be excluded with high probability by CTCA, with a moderate rate of false-positive results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Stent thrombosis is a safety concern associated with use of drug-eluting stents. Little is known about occurrence of stent thrombosis more than 1 year after implantation of such stents. METHODS: Between April, 2002, and Dec, 2005, 8146 patients underwent percutaneous coronary intervention with sirolimus-eluting stents (SES; n=3823) or paclitaxel-eluting stents (PES; n=4323) at two academic hospitals. We assessed data from this group to ascertain the incidence, time course, and correlates of stent thrombosis, and the differences between early (0-30 days) and late (>30 days) stent thrombosis and between SES and PES. FINDINGS: Angiographically documented stent thrombosis occurred in 152 patients (incidence density 1.3 per 100 person-years; cumulative incidence at 3 years 2.9%). Early stent thrombosis was noted in 91 (60%) patients, and late stent thrombosis in 61 (40%) patients. Late stent thrombosis occurred steadily at a constant rate of 0.6% per year up to 3 years after stent implantation. Incidence of early stent thrombosis was similar for SES (1.1%) and PES (1.3%), but late stent thrombosis was more frequent with PES (1.8%) than with SES (1.4%; p=0.031). At the time of stent thrombosis, dual antiplatelet therapy was being taken by 87% (early) and 23% (late) of patients (p<0.0001). Independent predictors of overall stent thrombosis were acute coronary syndrome at presentation (hazard ratio 2.28, 95% CI 1.29-4.03) and diabetes (2.03, 1.07-3.83). INTERPRETATION: Late stent thrombosis was encountered steadily with no evidence of diminution up to 3 years of follow-up. Early and late stent thrombosis were observed with SES and with PES. Acute coronary syndrome at presentation and diabetes were independent predictors of stent thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. METHODS AND RESULTS: Since January 2004, patients presenting with very late stent thrombosis (> 1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for > or = 2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630+/-166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9+/-16.0 versus 13.3+/-7.9 mm; P<0.001) and stents (34.6+/-22.4 versus 18.6+/-9.5 mm; P<0.001), more stents per lesion (1.6+/-0.9 versus 1.1+/-0.4; P<0.001), and stent overlap (39% versus 8%; P<0.001). Vessel cross-sectional area was similar for the reference segment (cross-sectional area of the external elastic membrane: 18.9+/-6.9 versus 20.4+/-7.2 mm2; P=0.46) but significantly larger for the in-stent segment (28.6+/-11.9 versus 20.1+/-6.7 mm2; P=0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P<0.001) and maximal incomplete stent apposition area was larger (8.3+/-7.5 versus 4.0+/-3.8 mm2; P=0.03) in patients with very late stent thrombosis compared with controls. CONCLUSIONS: Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.