981 resultados para simultaneous determination
Resumo:
Differential pulse stripping voltammetry method(DPSV) was applied to the determination of three herbicides, ametryn, cyanatryn, and dimethametryn. It was found that their voltammograms overlapped strongly, and it is difficult to determine these compounds individually from their mixtures. With the aid of chemometrics, classical least squares(CLS), principal component regression(PCR) and partial least squares(PLS), voltammogram resolution and quantitative analysis of the synthetic mixtures of the three compounds were successfully performed. The proposed method was also applied to the analysis of some real samples with satisfactory results.
Resumo:
A novel differential pulse voltammetry (DPV) method was developed for the simultaneous analysis of herbicides in water. A mixture of four herbicides, atrazine, simazine, propazine and terbuthylazine was analyzed simultaneously and the complex, overlapping DPV voltammograms were resolved by several chemometrics methods such as partial least squares (PLS), principal component regression (PCR) and principal component–artificial networks (PC–ANN). The complex profiles of the voltammograms collected from a synthetic set of samples were best resolved with the use of the PC–ANN method, and the best predictions of the concentrations of the analytes were obtained with the PC-ANN model (%RPET = 6.1 and average %Recovery = 99.0). The new method was also used for analysis of real samples, and the obtained results were compared well with those from the GC-MS technique. Such conclusions suggest that the novel method is a viable alternative to the other commonly used methods such as GC, HPLC and GC-MS.
Resumo:
Hybrid linear analysis (HLA) was applied to resolution of overlapping spectra of Fe3+-salicylfluorone and Al3+-salicylfluorone complexes and simultaneous spectrophotometric determination of Fe3+ and Al3+. The absorbance matrix of 7 standard mixtures at 41 measuring points ranged from the wavelength of 550 nm to 630 nm was used for calibration. To avoid the effect of interaction between the two components on the determination, the column vector of K matrix obtained from the standard mixtures with least squares was used as the pure spectrum of component. The recoveries of the two elements for the analysis of the synthetic samples were 93.3% similar to 107.5% in the range of the concentration ratio of Fe3+:Al3+ = 10:1 to 1:8. Comparing with the partial least squares (PIS) model, the HLA method was simple, accuracy and precise.
Resumo:
The voltammetric behaviour of acetophenetidin(A(1)) aminopyrine(A(2)) acetaminophenol(A(3)) and aminophenol(A(4)) was investigated by linear-sweep, differential-pulse, cyclic voltammetry at a glassy carbon electrode. In a medium of 0.1 mol/L NaOH solution, 4 high sensitivity and resolution anodic peaks were obtained. Their peak potentials are about at 0.68 V, 0.51, 0.22 and - 0.06 V( vs. Ag/AgCl). They can be used for direct determination of A(1), A(2),A(3),A(4) in samples respectively. The method is simple and rapid. The mechanism of the electrode reaction was discussed.
Resumo:
The absorption spectra of W, Mo and Ti-phenylfluorone cetyltrimethylammonium bromide complexes and the optimum conditions for the simultaneous spectrophotometric determination of microamounts of W, Mo and Ti were studied. In order to examine the effect of the errors of calibration matrix on the analytical resulte, the approach of selecting the analytical wavelengths was investigated and the comparison of computation results between AKC method (the matrix representation of Beer-Lambert's Law) and ...
Resumo:
A cathodically pretreated boron-doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry Linear calibration curves (r = 0 999) were obtained from 1 9 x 10(-5) to 2 I x 10(-4) mol L(-1) for AA and from 9 7 x 10(-6) to 1 1 x 10-4 mol L(-1) for CAF. with detection limits of 19 wool L(-1) and 7 0 mu nol L(-1). respectively This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations. with results equal to those obtained using a HPLC reference method
Resumo:
A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)(2) plus Mg(NO3)(2) as chemical modifier,to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0-50 mug l(-1) Ph in 0.2% v/v HNO3) were spiked with 25 mug l(-1) Bi. For a 20 mul aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rose wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91-104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 mug l(-1) Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.
Resumo:
Este artigo apresenta uma aplicação do método para determinação espectrofotométrica simultânea dos íons divalentes de cobre, manganês e zinco à análise de medicamento polivitamínico/polimineral. O método usa 4-(2-piridilazo) resorcinol (PAR), calibração multivariada e técnicas de seleção de variáveis e foi otimizado o empregando-se o algoritmo das projeções sucessivas (APS) e o algoritmo genético (AG), para escolha dos comprimentos de onda mais informativos para a análise. Com essas técnicas, foi possível construir modelos de calibração por regressão linear múltipla (RLM-APS e RLM-AG). Os resultados obtidos foram comparados com modelos de regressão em componentes principais (PCR) e nos mínimos quadrados parciais (PLS). Demonstra-se a partir do erro médio quadrático de previsão (RMSEP) que os modelos apresentam desempenhos semelhantes ao prever as concentrações dos três analitos no medicamento. Todavia os modelos RLM são mais simples pois requerem um número muito menor de comprimentos de onda e são mais fáceis de interpretar que os baseados em variáveis latentes.