984 resultados para reliability engineering
Resumo:
For a two layered long wave propagation, linearized governing equations, which were derived earlier from the Euler equations of mass and momentum assuming negligible friction and interfacial mixing are solved analytically using Fourier transform. For the solution, variations of upper layer water level is assumed to be sinosoidal having known amplitude and variations of interface level is solved. As the governing equations are too complex to solve it analytically, density of upper layer fluid is assumed as very close to the density of lower layer fluid to simplify the lower layer equation. A numerical model is developed using the staggered leap-forg scheme for computation of water level and discharge in one dimensional propagation having known amplitude for the variations of upper layer water level and interface level to be solved. For the numerical model, water levels (upper layer and interface) at both the boundaries are assumed to be known from analytical solution. Results of numerical model are verified by comparing with the analytical solutions for different time period. Good agreements between analytical solution and numerical model are found for the stated boundary condition. The reliability of the developed numerical model is discussed, using it for different a (ratio of density of fluid in the upper layer to that in the lower layer) and p (ratio of water depth in the lower layer to that in the upper layer) values. It is found that as ‘CX’ increases amplification of interface also increases for same upper layer amplitude. Again for a constant lower layer depth, as ‘p’ increases amplification of interface. also increases for same upper layer amplitude.
Resumo:
Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.
Resumo:
Despite the increasing utilization of all-ceramic crown systems, their mechanical performance relative to that of metal ceramic restorations (MCR) has yet to be determined. This investigation tested the hypothesis that MCR present higher reliability over two Y-TZP all-ceramic crown systems under mouth-motion fatigue conditions. A CAD-based tooth preparation with the average dimensions of a mandibular first molar was used as a master die to fabricate all restorations. One 0.5-mm Pd-Ag and two Y-TZP system cores were veneered with 1.5 mm porcelain. Crowns were cemented onto aged (60 days in water) composite (Z100, 3M/ESPE) reproductions of the die. Mouth-motion fatigue was performed, and use level probability Weibull curves were determined. Failure modes of all systems included chipping or fracture of the porcelain veneer initiating at the indentation site. Fatigue was an acceleration factor for all-ceramic systems, but not for the MCR system. The latter presented significantly higher reliability under mouth-motion cyclic mechanical testing.
Resumo:
Documentation of burn sequelae can be a difficult and time-consuming task. To date a reliable and systematic format for recording postburn trauma is lacking. The purpose of this research was two-fold: first, to develop a Modified Inventory of Potential Reconstructive Needs from the original Inventory of Potential Reconstructive Needs to allow methodical documentation of functional and cosmetic burn sequelae in all body surface areas of children with burns and, second, to establish interrater reliability and concurrent validity of the instrument, thus allowing its clinical application. Two raters scored the Modified Inventory of Potential Reconstructive Needs on 41 children with a range of burns types and severity. Excellent interrater reliability was demonstrated for both total (intraclass correlation coefficient = 0.996) and subsection inventory scores. Concurrent validity was also established with total scores showing strong positive correlations (0.73-0.76) with three indicators of burn severity. These findings provide initial support for the tool's clinical applicability, particularly in relation to rehabilitative planning and documentation.
Resumo:
In this paper, we look at three models (mixture, competing risk and multiplicative) involving two inverse Weibull distributions. We study the shapes of the density and failure-rate functions and discuss graphical methods to determine if a given data set can be modelled by one of these models. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
The purpose of this experiment was to assess the test-retest reliability of input-output parameters of the cortico-spinal pathway derived from transcranial magnetic (TMS) and electrical (TES) stimulation at rest and during muscle contraction. Motor evoked potentials (MEPs) were recorded from the first dorsal interosseous muscle of eight individuals on three separate days. The intensity of TMS at rest was varied from 5% below threshold to the maximal output of the stimulator. During trials in which the muscle was active, TMS and TES intensities were selected that elicited MEPs of between 150 and 300 X at rest. MEPs were evoked while the participants exerted torques up to 50% of their maximum capacity. The relationship between MEP size and stimulus intensity at rest was sigmoidal (R-2 = 0.97). Intra-class correlation coefficients (ICC) ranged between 0.47 and 0.81 for the parameters of the sigmoid function. For the active trials, the slope and intercept of regression equations of MEP size on level of background contraction were obtained more reliably for TES (ICC = 0.63 and 0.78, respectively) than for TMS (ICC = 0.50 and 0.53, respectively), These results suggest that input-output parameters of the cortico-spinal pathway may be reliably obtained via transcranial stimulation during longitudinal investigations of cortico-spinal plasticity. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Petrov-Galerkin methods are known to be versatile techniques for the solution of a wide variety of convection-dispersion transport problems, including those involving steep gradients. but have hitherto received little attention by chemical engineers. We illustrate the technique by means of the well-known problem of simultaneous diffusion and adsorption in a spherical sorbent pellet comprised of spherical, non-overlapping microparticles of uniform size and investigate the uptake dynamics. Solutions to adsorption problems exhibit steep gradients when macropore diffusion controls or micropore diffusion controls, and the application of classical numerical methods to such problems can present difficulties. In this paper, a semi-discrete Petrov-Galerkin finite element method for numerically solving adsorption problems with steep gradients in bidisperse solids is presented. The numerical solution was found to match the analytical solution when the adsorption isotherm is linear and the diffusivities are constant. Computed results for the Langmuir isotherm and non-constant diffusivity in microparticle are numerically evaluated for comparison with results of a fitted-mesh collocation method, which was proposed by Liu and Bhatia (Comput. Chem. Engng. 23 (1999) 933-943). The new method is simple, highly efficient, and well-suited to a variety of adsorption and desorption problems involving steep gradients. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Hereditary nonpolyposis colorectal cancer syndrome (HNPCC) is an autosomal dominant condition accounting for 2–5% of all colorectal carcinomas as well as a small subset of endometrial, upper urinary tract and other gastrointestinal cancers. An assay to detect the underlying defect in HNPCC, inactivation of a DNA mismatch repair enzyme, would be useful in identifying HNPCC probands. Monoclonal antibodies against hMLH1 and hMSH2, two DNA mismatch repair proteins which account for most HNPCC cancers, are commercially available. This study sought to investigate the potential utility of these antibodies in determining the expression status of these proteins in paraffin-embedded formalin-fixed tissue and to identify key technical protocol components associated with successful staining. A set of 20 colorectal carcinoma cases of known hMLH1 and hMSH2 mutation and expression status underwent immunoperoxidase staining at multiple institutions, each of which used their own technical protocol. Staining for hMSH2 was successful in most laboratories while staining for hMLH1 proved problematic in multiple labs. However, a significant minority of laboratories demonstrated excellent results including high discriminatory power with both monoclonal antibodies. These laboratories appropriately identified hMLH1 or hMSH2 inactivation with high sensitivity and specificity. The key protocol point associated with successful staining was an antigen retrieval step involving heat treatment and either EDTA or citrate buffer. This study demonstrates the potential utility of immunohistochemistry in detecting HNPCC probands and identifies key technical components for successful staining.
Resumo:
Composite clay nanostructures (CCNs) were observed in intercalating Laponite clay with alumina in the presence of alkyl polyether surfactants which contain hydrophobic alkyl chains and ether groups. Such nanostructured clays are highly porous solids consisting of randomly orientated clay platelets intercalated with alumina nanoparticles. The pores in the product solids are larger than the dimension of the surfactant molecules, ranging from 2 to 10 nm. This suggests that the micelles of the surfactant molecules, rather than the molecules, act as templates in the synthesis. Interestingly, it is found that the size of the framework pores was directly proportional to the amount of the surfactants in terms of moles, but shows no evident dependence on the size of the surfactant molecules. Broad pore size distributions were observed for the product CCNs. This study demonstrates that introducing surfactants in the pillaring process of clays is a powerful strategy for tailoring the pore structures of nanoporous clays. With this new technique, it is possible to design and engineer such composite clay nanostructures with desired pore and surface properties by the proper choice of surfactant amounts and preparation conditions.
Resumo:
This paper examines the psychometric quality of the Early/Late Preferences Scale (PS) relative to that of the Composite Morningness Scale (CS). Questionnaires were completed by 670 undergraduate students aged 16-37 years (mean 22.5), of whom 64% were female. Both scales displayed satisfactory inter-item correlations and similar total mean scores to those reported previously, although the CS had higher variability. Principal axis factor analysis produced single-factor solutions for both scales, although loadings for Items 7 and 9 on the PS were low. Internal consistencies for both scales were good (PS=0.86, CS=0.90) with only a small improvement achieved by deleting Items 7 and 9 from the PS. Test-retest reliability over 11 weeks was good for both scales (PS=0.92, CS=0.89). Differences between morning, evening and intermediate groups in self-rated alertness at different times of day, and significant correlations with other indices of morning-evening orientation, provided evidence of validity for both scales. These results indicate that PS is psychometrically comparable with CS. In view of its simpler format and lower cultural specificity, PS may be considered a preferable measure for most applications.