938 resultados para real-time measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The robotics community is concerned with the ability to infer and compare the results from researchers in areas such as vision perception and multi-robot cooperative behavior. To accomplish that task, this paper proposes a real-time indoor visual ground truth system capable of providing accuracy with at least more magnitude than the precision of the algorithm to be evaluated. A multi-camera architecture is proposed under the ROS (Robot Operating System) framework to estimate the 3D position of objects and the implementation and results were contextualized to the Robocup Middle Size League scenario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presented at SEMINAR "ACTION TEMPS RÉEL:INFRASTRUCTURES ET SERVICES SYSTÉMES". 10, Apr, 2015. Brussels, Belgium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presented at IEEE 21st International Conference on Embedded and Real-Time Computing Systems and Applications (RTCSA 2015). 19 to 21, Aug, 2015.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presented at 23rd International Conference on Real-Time Networks and Systems (RTNS 2015). 4 to 6, Nov, 2015, Main Track. Lille, France.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent embedded processor architectures containing multiple heterogeneous cores and non-coherent caches renewed attention to the use of Software Transactional Memory (STM) as a building block for developing parallel applications. STM promises to ease concurrent and parallel software development, but relies on the possibility of abort conflicting transactions to maintain data consistency, which in turns affects the execution time of tasks carrying transactions. Because of this fact the timing behaviour of the task set may not be predictable, thus it is crucial to limit the execution time overheads resulting from aborts. In this paper we formalise a FIFO-based algorithm to order the sequence of commits of concurrent transactions. Then, we propose and evaluate two non-preemptive and one SRP-based fully-preemptive scheduling strategies, in order to avoid transaction starvation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presented at Work in Progress Session, IEEE Real-Time Systems Symposium (RTSS 2015). 1 to 3, Dec, 2015. San Antonio, U.S.A..

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presented at Work in Progress Session, IEEE Real-Time Systems Symposium (RTSS 2015). 1 to 3, Dec, 2015. San Antonio, U.S.A..

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presented at INForum - Simpósio de Informática (INFORUM 2015). 7 to 8, Sep, 2015. Portugal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

EMC2 finds solutions for dynamic adaptability in open systems. It provides handling of mixed criticality multicore applications in r eal-time conditions, withscalability and utmost flexibility, full-scale deployment and management of integrated tool chains, through the entire lifecycle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

HHV-6 is the etiological agent of Exanthem subitum which is considered the sixth most frequent disease in infancy. In immuno-compromised hosts, reactivation of latent HHV-6 infection may cause severe acute disease. We developed a Sybr Green Real Time PCR for HHV-6 and compared the results with nested conventional PCR. A 214 pb PCR derived fragment was cloned using pGEM-T easy from Promega system. Subsequently, serial dilutions were made in a pool of negative leucocytes from 10-6 ng/µL (equivalent to 2465.8 molecules/µL) to 10-9 (equivalent to 2.46 molecules/µL). Dilutions of the plasmid were amplified by Sybr Green Real Time PCR, using primers HHV3 (5' TTG TGC GGG TCC GTT CCC ATC ATA 3)'and HHV4 (5' TCG GGA TAG AAA AAC CTA ATC CCT 3') and by conventional nested PCR using primers HHV1 (outer): 5'CAA TGC TTT TCT AGC CGC CTC TTC 3'; HHV2 (outer): 5' ACA TCT ATA ATT TTA GAC GAT CCC 3'; HHV3 (inner) and HHV4 (inner) 3'. The detection threshold was determined by plasmid serial dilutions. Threshold for Sybr Green real time PCR was 24.6 molecules/µL and for the nested PCR was 2.46 molecules/µL. We chose the Real Time PCR for diagnosing and quantifying HHV-6 DNA from samples using the new Sybr Green chemistry due to its sensitivity and lower risk of contamination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Real-time monitoring applications may be used in a wireless sensor network (WSN) and may generate packet flows with strict quality of service requirements in terms of delay, jitter, or packet loss. When strict delays are imposed from source to destination, the packets must be delivered at the destination within an end-to-end delay (EED) hard limit in order to be considered useful. Since the WSN nodes are scarce both in processing and energy resources, it is desirable that they only transport useful data, as this contributes to enhance the overall network performance and to improve energy efficiency. In this paper, we propose a novel cross-layer admission control (CLAC) mechanism to enhance the network performance and increase energy efficiency of a WSN, by avoiding the transmission of potentially useless packets. The CLAC mechanism uses an estimation technique to preview packets EED, and decides to forward a packet only if it is expected to meet the EED deadline defined by the application, dropping it otherwise. The results obtained show that CLAC enhances the network performance by increasing the useful packet delivery ratio in high network loads and improves the energy efficiency in every network load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hepatitis B virus (HBV) is a major cause of chronic liver disease worldwide. Besides genotype, quantitative analysis of HBV infection is extensively used for monitoring disease progression and treatment. Affordable viral load monitoring is desirable in resource-limited settings and it has been already shown to be useful in developing countries for other viruses such as Hepatitis C virus (HCV) and HIV. In this paper, we describe the validation of a real-time PCR assay for HBV DNA quantification with TaqMan chemistry and MGB probes. Primers and probes were designed using an alignment of sequences from all HBV genotypes in order to equally amplify all of them. The assay is internally controlled and was standardized with an international HBV panel. Its efficacy was evaluated comparing the results with two other methods: Versant HBV DNA Assay 3.0 (bDNA, Siemens, NY, USA) and another real-time PCR from a reference laboratory. Intra-assay and inter-assay reproducibilities were determined and the mean of CV values obtained were 0.12 and 0.09, respectively. The assay was validated with a broad dynamic range and is efficient for amplifying all HBV genotypes, providing a good option to quantify HBV DNA as a routine procedure, with a cheap and reliable protocol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel SYBR® green-real time polymerase chain reaction (qPCR) was developed to detect two Bartonellaspecies, B. henselae and B. clarridgeiae, directly from blood samples. The test was used in blood samples obtained from cats living in animal shelters in Southern Brazil. Results were compared with those obtained by conventional PCR targeting Bartonella spp. Among the 47 samples analyzed, eight were positive using the conventional PCR and 12 were positive using qPCR. Importantly, the new qPCR detected the presence of both B. henselae and B. clarridgeiae in two samples. The results show that the qPCR described here may be a reliable tool for the screening and differentiation of two important Bartonella species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess quantitative real-time polymerase chain reaction (q-PCR) for the sputum smear diagnosis of pulmonary tuberculosis (PTB) in patients living with HIV/AIDS with a clinical suspicion of PTB.Method: This is a prospective study to assess the accuracy of a diagnostic test, conducted on 140 sputum specimens from 140 patients living with HIV/AIDS with a clinical suspicion of PTB, attended at two referral hospitals for people living with HIV/AIDS in the city of Recife, Pernambuco, Brazil. A Löwenstein-Jensen medium culture and 7H9 broth were used as gold standard.Results: Of the 140 sputum samples, 47 (33.6%) were positive with the gold standard. q-PCR was positive in 42 (30%) of the 140 patients. Only one (0.71%) did not correspond to the culture. The sensitivity, specificity and accuracy of the q-PCR were 87.2%, 98.9% and 95% respectively. In 39 (93%) of the 42 q-PCR positive cases, the CT (threshold cycle) was equal to or less than 37.Conclusion: q-PCR performed on sputum smears from patients living with HIV/AIDS demonstrated satisfactory sensitivity, specificity and accuracy, and may therefore be recommended as a method for diagnosing PTB.