930 resultados para range of motion (ROM)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The proprioceptive neuromuscular facilitation technique (PNF) has been proven to be efficient, since it was found higher gain of joint range-of-motion compared to the classic stretching. This study aimed to perform a comparison between the muscular stretching techniques and the PNF hold-relax on the internal and external sagittal/diagonal plane.Method: Randomly divided in 3 groups by a drawing, 30 healthy male individuals have undergone the test. In group I the hold-relax technique was utilized on the sagittal plane, grupo II receveid hold-relax on the internal and external diagonals, and group III, on which an evaluation was performed, worked as control. All the groups went through tests on the first, fifth and fifteenth day after the application of the different approaches. In this evaluation it was used a Flexis (R) Fleximeter.Result: Group II (diagonal) obtained statistically significant gain of 13.99% in the immediate post-test and post test later obtained a loss of 4.81%, group I (sagittal) showed no statistical difference as the group III (control).Conclusion: We conclude that the technique of PNF in the diagonal plane is effective in the flexibility of the hamstring muscles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We derive the torsion constraints and show the consistency of equations of motion of four-dimensional Type II supergravity in superspace. with Type II sigma model. This is achieved by coupling the four-dimensional compactified Type II Berkovits' superstring to an N = 2 curved background and requiring that the sigma-model has superconformal invariance at tree-level. We compute this in a manifestly 4D N = 2 supersymmetric way. The constraints break the target conformal and SU(2) invariances and the dilaton will be a conformal, SU(2) x U(1) compensator. For Type II superstring in four dimensions, worldsheet supersymmetry requires two different compensators. One type is described by chiral and anti-chiral superfields. This compensator can be identified with a vector multiplet. The other Type II compensator is described by twist-chiral and twist-anti-chiral superfields and can be identified with a tensor hypermultiplet. Also, the superconformal invariance at tree-level selects a particular gauge, where the matter is fixed, but not the compensators. After imposing the reality conditions, we show that the Type II sigma model at tree-level is consistent with the equations of motion for Type II supergravity in the string gauge. (C) 2003 Elsevier B.V All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O estudo do raio de ação das abelhas na coleta de néctar e pólen é de extrema importância para se saber até que distância a polinização por este inseto é promovida com eficiência. Para tanto, cinco colônias de abelhas africanizadas marcadas com 32P foram levadas a um pomar de maçã, sendo agrupadas no centro de uma área de 0,8 ha, a partir do qual foram colocadas estacas a cada 10m, formando quatro alas correspondentes às direções Norte, Sul, Leste e Oeste. As abelhas foram capturadas duas vezes por dia e por dez dias consecutivos, quando visitavam as flores das macieiras, até 50m do centro. Verificou-se que o número de abelhas marcadas coletadas, diminuiu linearmente à medida em que as mesmas se afastavam das colméias. Não houve interferência das orientações geográficas no comportamento de vôo das abelhas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a technique for extending the force range of thin conductive polymer force sensors used for measuring contact force. These sensors are conventionally used for measuring force by changing electrical resistance when they are compressed. The new method involves measuring change in electrical resistance when the flexible sensor, which is sensitive to both compression and bending, is sandwiched between two layers of spring steel, and the structure is supported on a thin metal ring. When external force is applied, the stiffened sensor inside the spring steel is deformed within the annular center of the ring, causing the sensor to bend in proportion to the applied force. This method effectively increases the usable force range, while adding little in the way of thickness and weight. Average error for loads between 10 N and 100 N was 2.2 N (SD = 1.7) for a conventional conductive polymer sensor, and 0.9 N (SD = 0.4) using the new approach. Although this method permits measurement of greater loads with an error less than 1 N, it is limited since the modified sensor is insensitive to loads less than 5 N. These modified sensors are nevertheless useful for directly measuring normal force applied against handles and tools and other situations involving forceful manual work activities, such as grasp, push, pull, or press that could not otherwise be measured in actual work situations.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pereira, GR, Leporace, G, Chagas, DV, Furtado, LFL, Praxedes, J, and Batista, LA. Influence of hip external rotation on hip adductor and rectus femoris myoelectric activity during a dynamic parallel squat. J Strength Cond Res 24(10): 27492754, 2010-This study sought to compare the myoelectric activity of the hip adductors (HAs) and rectus femoris (RF) when the hip was in a neutral position or externally rotated by 30 degrees or 50 degrees (H0, H30, and H50, respectively) during a parallel squat. Ten healthy subjects performed 10 repetitions of squats in each of the 3 hip positions and the myoelectric activities of the HAs and RF were recorded. The signal was then divided into categories representing concentric (C) and eccentric (E) contractions in the following ranges of motion: 0-30 degrees (C1 and E1), 30-60 degrees (C2 and E2), and 60-90 degrees (C3 and E3) of knee flexion. From those signals, an root mean square (RMS) value for each range of motion in each hip position was obtained. All values were normalized to those obtained during maximum voluntary isometric contraction. We found that HAs showed a significant increase in myoelectric activity during C3 and E3 in the H30 and H50 positions, as compared with H0. Meanwhile, RF activity did not significantly differ between hip positions. Both muscles showed higher activation during 60-90 degrees (C3 and E3) of knee flexion, as compared with 0-30 degrees (C1 and E1) and 30-60 degrees (C2 and E2). The results suggest that if the aim is to increase HA activity despite the low percentage of muscle activation, squats should be performed with 30 degrees of external rotation and at least 90 degrees of knee flexion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It was evaluated movements of lower limb in the double pulley system equipment on ten male volunteers during contraction of gastrocnemius (caput laterale ) and gluteus maximus muscles in the following movements: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. Myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. We observed weak gastrocnemius muscle activity for all movements studied. In the case of gluteus maximus, the most important potentials were observed for movement 2, while for the remaining movements the actions were of reasonable intensity. Compared to gluteus, gastrocnemius was less required for all movements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study quantified by, electrovibratography, the amount of mandible protrusion required to decrease significantly temporomandibular joint (TMJ) vibratory energy as an aid in the diagnosis of the recapture of anteriorly displaced disk. Eighteen patients diagnosed as having anterior disk displacement with reduction and TMJ clicking were submitted to electrovibratographic examination at the first appointment and treated with a stabilizing appliance and anterior positioning appliance with 1 to 5 mm protrusion. Vibratory energy was checked in each of these positions. Baseline data were used as control. At the first appointment, the patients had vibrations with more elevated intensities at the middle and late phases of the mouth opening cycle. At only one clinical step, mandible protrusion was obtained with the anterior repositioning appliance, ranging from 1 to 5 mm protusion. At each new position, a new electrovibratographic exam was made. After the 5-mm mandibular projection, only 2 patients presented vibration, with means between 0.6 and 2.8 Hz. Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). The outcomes of this study indicate that 3 mm is the minimum amount of mandible protrusion to significantly decrease the TMJ vibratory energy and to recapture the displaced articular disk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Occlusion is a predisposing factor for Temporomandibular Dysfunctions (TMD) of the joint, whose first sign and/or symptom is usually joint sound. To verify the effect of occlusion on joint sounds, temporomandibular joints (TMJ) were analyzed in 78 asymptomatic individuals with various dental conditions. Electrosonography was used to determine the intensity of the vibration in the temporomandibular joint (TMJ) on opening and closing the mouth. Transducers (piezoelectric accelerometer) were placed on the right and left joints. Results were tabled and analyzed using the Kruskal-Wallis test (a=0.05). It was concluded that TMJ vibration in partly edentulous individuals from Kennedy classes I, II and III is statistically higher than in dentate and fully edentulous subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this report, we present a case of myositis ossificans traumatica (MOT) of the medial pterygoid muscle that had developed after mandibular block anesthesia administered for endodontic treatment of the lower right second molar, demonstrating typical features of this condition. MOT should be considered as a differential diagnosis when there is severe limitation of jaw opening and an associated trauma. Panoramic radiographs and axial and coronal computed tomography (CT) scans can effectively delineate the calcified mass. Other imaging studies that may be helpful include magnetic resonance imaging (MRI), bone scans, and ultrasound. As shown in our case, calcified masses were found in the right mandibular angle, which severely limited jaw opening. Some earlier reported cases of MOT were treated by extraoral surgical approaches with complete removal of the evolving muscle. The aim of this case report is to present only the diagnostic imaging aspects of myositis ossificans traumatica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Temporomandibular disorders is a collective term used to describe a number of related disorders involving the temporomandibular joints, masticatory muscles and occlusion with common symptoms such as pain, restricted movement, muscle tenderness and intermittent joint sounds. The multifactorial TMD etiology is related to emotional tension, occlusal interferences, tooth loss, postural deviation, masticatory muscular dysfunction, internal and external changes in TMJ structure and the various associations of these factors. The aim of this study was to evaluate the prevalence of the relationship between signs of psychological distress and temporomandibular disorder in university students. A total 150 volunteers participated in this study. They attended different courses in the field of human science at one public university and four private universities. TMD was assessed by the Research Diagnostic Criteria (RDC) questionnaire. Anxiety was measured by means of a self-evaluative questionnaire, Spielberger's Trait-State anxiety inventory, to evaluate students'state and trait anxiety. The results of the two questionnaires were compared to determine the relationship between anxiety levels and severity degrees of chronic TMD pain by means of the chi-square test. The significance level was set at 5%. The statistical analysis showed that the TMD degree has a positive association with state-anxiety (p = 0.008; p < 0.05) and negative with trait-anxiety (p = 0.619; p < 0.05). Moreover a high TMD rate was observed among the students (40%). This study concluded that there is a positive association between TMD and anxiety.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Data describing the relationships between postural alignment and stance stability are scarce and controversial. Objective: The aim of this study was to evaluate the effects of sensory disturbances on knee alignment in upright stance and the effects of knee hyperextension on stance stability. Method: Kinetic and kinematic data of 23 healthy adult women were collected while quietly standing in four sensory conditions. Kinematic data: knee angle (dependent variables) variations were analyzed across sensory conditions. Kinetic data: as subjects with hyperextended knees showed a clear tendency to flex their knees as balance challenge increased, center of pressure (COP) parameters (dependent variables) were analyzed in each sensory condition among trial sub-groups: Aligned-Trials (knee angle < 180°), Hyperextended-Trials (>180°) and Adjusted-Trials (>180° initially, turned <180° under challenging conditions). Results: Differences were found in mean velocity of COP in two conditions showing that knee alignment can affect stance stability. Conclusion: Knee hyperextension is a transient condition changing under postural challenges. Knee hyperextension affected postural control as mean velocity was the highest in the hyperextended group in natural standing sensory condition and lowest with sensory disturbance. © 2009 Elsevier Ltd.