975 resultados para pulse-width modulator
Resumo:
The equivalent annulus width concept is used to characterize a small commercial thermogravitational hermal diffusion column and its validity checked experimentally by separating batchwise in the column mixtures of n-heptanebenzene with different initial concentrations. The equation of Ruppell and Coull was used to analyse the data in the short separation times range and determine the equivalent annulus width. Good agreement was obtained between the experimental and predicted time-separation curves when using the equivalent annulus width value and on averaged value of the thermal diffusion constant. A new method is presented for the simultaneous determination of the equivalent annulus width and the thermal diffusion constant of a binary mixture from a single set of experimental data.
Resumo:
This work describes a test tool that allows to make performance tests of different end-to-end available bandwidth estimation algorithms along with their different implementations. The goal of such tests is to find the best-performing algorithm and its implementation and use it in congestion control mechanism for high-performance reliable transport protocols. The main idea of this paper is to describe the options which provide available bandwidth estimation mechanism for highspeed data transport protocols and to develop basic functionality of such test tool with which it will be possible to manage entities of test application on all involved testing hosts, aided by some middleware.
Resumo:
The present contribution aims at evaluating the carapace width vs. humid weight relationship and the condition factor of Ucides cordatus (Linnaeus, 1763), in the mangrove forests of the Ariquindá and Mamucabas rivers, state of Pernambuco, Brazil. These two close areas present similar characteristics of vegetation and substrate, but exhibit different degrees of environmental conservation: the Ariquindá River is the preserved area, considered one of the last non-polluted of Pernambuco, while the Mamucabas River suffers impacts from damming, deforestation and deposition of waste. A total of 1,298 individuals of U. cordatus were collected. Males were larger and heavier than females, what is commonly observed in Brachyura. Ucides cordatus showed allometric negative growth (p < 0.05), which is probably related to the dilatation that this species develops in the lateral of the carapace, which stores six pairs of gills. The values of b were within the limit established for aquatic organisms. Despite of the condition factor being considered an important feature to confirm the reproductive period, since it varies with cyclic activities, in the present study it was not correlated to the abundance of ovigerous females. However, it was considered a good parameter to evaluate environmental impacts, being significantly lower at the impacted area.
Resumo:
Auditory spatial functions, including the ability to discriminate between the positions of nearby sound sources, are subserved by a large temporo-parieto-frontal network. With the aim of determining whether and when the parietal contribution is critical for auditory spatial discrimination, we applied single pulse transcranial magnetic stimulation on the right parietal cortex 20, 80, 90 and 150 ms post-stimulus onset while participants completed a two-alternative forced choice auditory spatial discrimination task in the left or right hemispace. Our results reveal that transient TMS disruption of right parietal activity impairs spatial discrimination when applied at 20 ms post-stimulus onset for sounds presented in the left (controlateral) hemispace and at 80 ms for sounds presented in the right hemispace. We interpret our finding in terms of a critical role for controlateral temporo-parietal cortices over initial stages of the building-up of auditory spatial representation and for a right hemispheric specialization in integrating the whole auditory space over subsequent, higher-order processing stages.
Resumo:
OBJECTIVE: To test the accuracy of a new pulse oximeter sensor based on transmittance and reflectance. This sensor makes transillumination of tissue unnecessary and allows measurements on the hand, forearm, foot, and lower limb. DESIGN: Prospective, open, nonrandomized criterion standard study. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 54 critically ill neonates (gestational age 27 to 42 wks; postnatal age 1 to 28 days) with arterial catheters in place. MEASUREMENTS AND MAIN RESULTS: A total of 99 comparisons between pulse oximetry and arterial saturation were obtained. Comparison of femoral or umbilical arterial blood with transcutaneous measurements on the lower limb (n = 66) demonstrated an excellent correlation (r2 = .96). The mean difference was +1.44% +/- 3.51 (SD) % (range -11% to +8%). Comparison of the transcutaneous values with the radial artery saturation from the corresponding upper limb (n = 33) revealed a correlation coefficient of 0.94 with a mean error of +0.66% +/- 3.34% (range -6% to +7%). The mean difference between noninvasive and invasive measurements was least with the test sensor on the hand, intermediate on the calf and arm, and greatest on the foot. The mean error and its standard deviation were slightly larger for arterial saturation values < 90% than for values > or = 90%. CONCLUSION: Accurate pulse oximetry saturation can be acquired from the hand, forearm, foot, and calf of critically ill newborns using this new sensor.
Resumo:
BACKGROUND: Reconstruction of the central aortic pressure wave from the noninvasive recording of the radial pulse with applanation tonometry has become a standard tool in the field of hypertension. It is not presently known whether recording the radial pulse on the dominant or the nondominant side has any effect on such reconstruction. METHOD: We carried out radial applanation tonometry on both forearms in young, healthy, male volunteers, who were either sedentary (n = 11) or high-level tennis players (n = 10). The purpose of including tennis players was to investigate individuals with extreme asymmetry between the dominant and nondominant upper limb. RESULTS: In the sedentary individuals, forearm circumference and handgrip strength were slightly larger on the dominant (mean +/- SD respectively 27.9 +/- 1.5 cm and 53.8 +/- 10 kg) than on nondominant side (27.3 +/- 1.6 cm, P < 0.001 vs. dominant, and 52.1 +/- 11 kg, P = NS). In the tennis players, differences between sides were more conspicuous (forearm circumference: dominant 28.0 +/- 1.7 cm nondominant 26.4 +/- 1.5 cm, P < 0.001; handgrip strength 61.4 +/- 10.8 vs. 53.4 +/- 9.7 kg, P < 0.001). We found that in both sedentary individuals and tennis players, the radial pulse had identical shape on both sides and, consequently, the reconstructed central aortic pressure waveforms, as well as derived indices of central pulsatility, were not dependent on the side where applanation tonometry was carried out. CONCLUSION: Evidence from individuals with maximal asymmetry of dominant vs. nondominant upper limb indicates that laterality of measurement is not a methodological issue for central pulse wave analysis carried out with radial applanation tonometry.
Resumo:
We evaluated a new pulse oximeter designed to monitor beat-to-beat arterial oxygen saturation (SaO2) and compared the monitored SaO2 with arterial samples measured by co-oximetry. In 40 critically ill children (112 data sets) with a mean age of 3.9 years (range 1 day to 19 years), SaO2 ranged from 57% to 100%, and PaO2 from 27 to 128 mm Hg, heart rates from 85 to 210 beats per minute, hematocrit from 20% to 67%, and fetal hemoglobin levels from 1.3% to 60%; peripheral temperatures varied between 26.5 degrees and 36.5 degrees C. Linear correlation analysis revealed a good agreement between simultaneous pulse oximeter values and both directly measured SaO2 (r = 0.95) and that calculated from measured arterial PaO2 (r = 0.95). The device detected several otherwise unrecognized drops in SaO2 but failed to function in four patients with poor peripheral perfusion secondary to low cardiac output. Simultaneous measurements with a tcPO2 electrode showed a similarly good correlation with PaO22 (r = 0.91), but the differences between the two measurements were much wider (mean 7.1 +/- 10.3 mm Hg, range -14 to +49 mm Hg) than the differences between pulse oximeter SaO2 and measured SaO2 (1.5% +/- 3.5%, range -7.5% to -9%) and were not predictable. We conclude that pulse oximetry is a reliable and accurate noninvasive device for measuring saturation, which because of its rapid response time may be an important advance in monitoring changes in oxygenation and guiding oxygen therapy.
Resumo:
Inflammation is intimately linked with naturally occurring remodeling events in the endometrium. Lipoxins comprise a group of short-lived, nonclassic eicosanoids possessing potent anti-inflammatory and proresolution properties. In the present study, we investigated the role of lipoxin A(4) (LXA(4)) in the endometrium and demonstrated that 15-LOX-2, an enzyme necessary for LX biosynthesis, is expressed in this tissue. Our results establish that LXA(4) possesses robust estrogenic activity through its capacity to alter ERE transcriptional activity, as well as expression of estrogen-regulated genes, alkaline phosphatase activity, and proliferation in human endometrial epithelial cells. Interestingly, LXA(4) also demonstrated antiestrogenic potential, significantly attenuating E2-induced activity. This estrogenic activity was directly mediated through estrogen receptors (ERs). Subsequent investigations determined that the actions of LXA(4) are exclusively mediated through ERα and closely mimic those of the potent estrogen 17β-estradiol (E2). In binding assays, LXA(4) competed with E2 for ER binding, with an IC(50) of 46 nM. Furthermore, LXA(4) exhibited estrogenic activity in vivo, increasing uterine wet weight and modulating E2-regulated gene expression. These findings reveal a previously unappreciated facet of LXA(4) bioactions, implicating this lipid mediator in novel immunoendocrine crosstalk mechanisms.
Resumo:
Hypergraph width measures are a class of hypergraph invariants important in studying the complexity of constraint satisfaction problems (CSPs). We present a general exact exponential algorithm for a large variety of these measures. A connection between these and tree decompositions is established. This enables us to almost seamlessly adapt the combinatorial and algorithmic results known for tree decompositions of graphs to the case of hypergraphs and obtain fast exact algorithms. As a consequence, we provide algorithms which, given a hypergraph H on n vertices and m hyperedges, compute the generalized hypertree-width of H in time O*(2n) and compute the fractional hypertree-width of H in time O(1.734601n.m).1
Resumo:
Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.
Resumo:
BackgroundMutations in TNFRSF13B, the gene encoding transmembrane activator and calcium modulator cyclophilin ligand interactor (TACI), are found in 10% of patients with common variable immunodeficiency. However, the most commonly detected mutation is the heterozygous change C104R, which is also found in 0.5% to 1% of healthy subjects. The contribution of the C104R mutation to the B-cell defects observed in patients with common variable immunodeficiency therefore remains unclear.ObjectiveWe sought to define the functional consequences of the C104R mutation on B-cell function.MethodsWe performed in vitro studies of TACI C104R expression and signaling. A knock-in mouse with the equivalent mutation murine TACI (mTACI) C76R was generated as a physiologically relevant model of human disease. We examined homozygous and heterozygous C76R mutant mice alongside wild-type littermates and studied specific B-cell lineages and antibody responses to T cell-independent and T cell-dependent challenge.ResultsC104R expression and ligand binding are significantly diminished when the mutant protein is expressed in 293T cells or in patients' cell lines. This leads to defective nuclear factor κB activation, which is proportionally restored by reintroduction of wild-type TACI. Mice heterozygous and homozygous for mTACI C76R exhibit significant B-cell dysfunction with splenomegaly, marginal zone B-cell expansion, diminished immunoglobulin production and serological responses to T cell-independent antigen, and abnormal immunoglobulin synthesis.ConclusionsThese data show that the C104R mutation and its murine equivalent, C76R, can significantly disrupt TACI function, probably through haploinsufficiency. Furthermore, the heterozygous C76R mutation alone is sufficient to disturb B-cell function with lymphoproliferation and immunoglobulin production defects.
Resumo:
Introduction: The Fragile X - associated Tremor Ataxia Syndrome (FXTAS) is a recently described, and under-diagnosed, late onset (≈ 60y) neurodegenerative disorder affecting male carriers of a premutation in the Fragile X Mental Retardation 1 (FMR1) gene. The premutation is an CGG (Cytosine-Guanine-Guanine) expansion (55 to 200 CGG repeats) in the proximal region of the FMR1 gene. Patients with FXTAS primarily present with cerebellar ataxia and intention tremor. Neuroradiological features of FXTAS include prominent white matter disease in the periventricular, subcortical, middle cerebellar peduncles and deep white matter of the cerebellum on T2-weighted or FLAIR MR imaging (Jacquemmont 2007, Loesch 2007, Brunberg 2002, Cohen 2006). We hypothesize that a significant white matter alteration is present in younger individuals many years prior to clinical symptoms and/or the presence of visible lesions on conventional MR sequences and might be detectable by magnetization transfer (MT) imaging. Methods: Eleven asymptomatic premutation carriers (mean age = 55 years) and seven intra-familial controls participated to the study. A standardized neurological examination was performed on all participants and a neuropsychological evaluation was carried out before MR scanning performed on a 3T Siemens Trio. The protocol included a sagittal T1-weighted 3D gradient-echo sequence (MPRAGE, 160 slices, 1 mm^3 isotropic voxels) and a gradient-echo MTI (FA 30, TE 15, matrix size 256*256, pixel size 1*1 mm, 36 slices (thickness 2mm), MT pulse duration 7.68 ms, FA 500, frequency offset 1.5 kHz). MTI was performed by acquiring consecutively two set of images; first with and then without the MT saturation pulse. MT images were coregistered to the T1 acquisition. The MTR for every intracranial voxel was calculated as follows: MTR = (M0 - MS)/M0*100%, creating a MTR map for each subject. As first analysis, the whole white matter (WM) was used to mask the MTR image in order to create an histogram of the MTR distribution in the whole tissue class over the two groups examined. Then, for each subject, we performed a segmentation and parcellation of the brain by means of Freesurfer software, starting from the high resolution T1-weighted anatomical acquisition. Cortical parcellations was used to assign a label to the underlying white matter by the construction of a Voronoi diagram in the WM voxels of the MR volume based on distance to the nearest cortical parcellation label. This procedure allowed us to subdivide the cerebral WM in 78 ROIs according to the cortical parcellation (see example in Fig 1). The cerebellum, by the same procedure, was subdivided in 5 ROIs (2 per each hemisphere and one corresponding to the brainstem). For each subject, we calculated the mean value of MTR within each ROI and averaged over controls and patients. Significant differences between the two groups were tested using a two sample T-test (p<0.01). Results: Neurological examination showed that no patient met the clinical criteria of Fragile X Tremor and Ataxia Syndrome yet. Nonetheless, premutation carriers showed some subtle neurological signs of the disorder. In fact, premutation carriers showed a significant increase of tremor (CRST, T-test p=0.007) and increase of ataxia (ICARS, p=0.004) when compared to controls. The neuropsychological evaluation was normal in both groups. To obtain general characterizations of myelination for each subject and premutation carriers, we first computed the distribution of MTR values across the total white matter volume and averaged for each group. We tested the equality of the two distributions with the non parametric Kolmogorov-Smirnov test and we rejected the null-hypothesis at a p=0.03 (fig. 2). As expected, when comparing the asymptomatic permutation carriers with control subjects, the peak value and peak position of the MTR values within the whole WM were decreased and the width of the distribution curve was increased (p<0.01). These three changes point to an alteration of the global myelin status of the premutation carriers. Subsequently, to analyze the regional myelination and white matter integrity of the same group, we performed a ROI analysis of MTR data. The ROI-based analysis showed a decrease of mean MTR value in premutation carriers compared to controls in bilateral orbito-frontal and inferior frontal WM, entorhinal and cingulum regions and cerebellum (Fig 3). The detection of these differences in these regions failed with other conventional MR techniques. Conclusions: These preliminary data confirm that in premutation carriers, there are indeed alterations in "normal appearing white matter" (NAWM) and these alterations are visible with the MT technique. These results indicate that MT imaging may be a relevant approach to detect both global and local alterations within NAWM in "asymptomatic" carriers of premutations in the Fragile X Mental Retardation 1 (FMR1) gene. The sensitivity of MT in the detection of these alterations might point towards a specific physiopathological mechanism linked to an underlying myelin disorder. ROI-based analyses show that the frontal, parahippocampal and cerebellar regions are already significantly affected before the onset of symptoms. A larger sample will allow us to determine the minimum CGG expansion and age associated with these subclinical white matter alterations.