998 resultados para pulmonary valve stenosis
Resumo:
In this study, we show the use of three-dimensional printing models for preoperative planning of transcatheter valve replacement in a patient with an extreme porcelain aorta. A 70-year-old man with severe aortic stenosis and a porcelain aorta was referred to our center for transcatheter aortic valve replacement. Unfortunately, the patient died after the procedure because of a potential ischemic event. Therefore, we decided to fabricate three-dimensional models to evaluate the potential effects of these constructs for previous surgical planning and simulation of the transcatheter valve replacement.
Resumo:
Renovascular hypertension is due to reduced renal parenchymal perfusion. The correct diagnosis can be difficult. It is important to note that the demonstration of renal artery stenosis in a patient with hypertension does not necessarily constitute renovascular hypertension. Often, clinically nonsignificant and asymptomatic renal artery stenosis are found in patients with essential hypertension, or renal failure of other origin. Renovascular disease is a complex disorder with various clinical presentations. In patients with significant renovascular hypertension plasma renin is increased. For this reason the therapy aims to block the renin-angiotensin-aldosterone system. Bilateral renal artery stenosis causes renal sodium retention. In this situation a diuretic drug has to be added to the therapy. Endovascular or surgical therapy has to be considered in patients with flash pulmonary edema or fibromuscular dysplasia. The control of cardiovascular risk factors is important.
Resumo:
Percutaneous valve replacement for severe aortic stenosis has shown to be an alternative treatment option for non-surgical candidates. We report on the first successful valve in valve procedure in an 80-year-old patient with a severe regurgitation of a degenerated aortic bioprosthesis using the Corevalve Revalving system.
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.
Resumo:
In the present report the prevalence, severity, and risk factors of tricuspid valve regurgitation (TR) in 251 heart transplant recipients have been analyzed retrospectively. Tricuspid valve function was studied by color-flow Doppler echocardiogram and annual heart catheterization. The presence or severity of TR was graded on a scale from 0 (no TR) to 4 (severe). Additional postoperative data included rate of rejection, number of endomyocardial biopsies, incidence of transplant vasculopathy, and preoperative and postoperative hemodynamics. The incidence of grade 3 TR increases from 5% at 1 year to 50% at 4 years after transplantation. Multivariate analysis showed rate of rejection and donor heart weight to be significant risk factors. The ischemic intervals as well as the preoperative and postoperative pulmonary hemodynamics did not affect the severity or prevalence of TR. These results indicate that various factors appear to have an impact on the development of TR and that the prevalence might be lowered by a reduction of the number of biopsies performed and when possible, oversizing of donor hearts.
Resumo:
Flash pulmonary edema (FPE) is a general clinical term used to describe a particularly dramatic form of acute decompensated heart failure. Well-established risk factors for heart failure such as hypertension, coronary ischemia, valvular heart disease, and diastolic dysfunction are associated with acute decompensated heart failure as well as with FPE. However, endothelial dysfunction possibly secondary to an excessive activity of renin-angiotensin-aldosterone system, impaired nitric oxide synthesis, increased endothelin levels, and/or excessive circulating catecholamines may cause excessive pulmonary capillary permeability and facilitate FPE formation. Renal artery stenosis particularly when bilateral has been identified has a common cause of FPE. Lack of diurnal variation in blood pressure and a widened pulse pressure have been identified as risk factors for FPE. This review is an attempt to delineate clinical and pathophysiological mechanisms responsible for FPE and to distinguish pathophysiologic, clinical, and therapeutic aspects of FPE from those of acute decompensated heart failure.
Resumo:
BACKGROUND: Regression of left ventricular (LV) hypertrophy with normalization of diastolic function has been reported in patients with aortic stenosis late after aortic valve replacement (AVR). The purpose of the present study was to evaluate the effect of AVR on LV function and structure in chronic aortic regurgitation early and late after AVR. METHODS AND RESULTS: Twenty-six patients were included in the present analysis. Eleven patients with severe aortic regurgitation were studied before, early (21 months) and late (89 months) after AVR through the use of LV biplane angiograms, high-fidelity pressure measurements, and LV endomyocardial biopsies. Fifteen healthy subjects were used as controls. LV systolic function was determined from biplane ejection fraction and midwall fractional shortening. LV diastolic function was calculated from the time constant of LV relaxation, peak filling rates, and myocardial stiffness constant. LV structure was assessed from muscle fiber diameter, interstitial fibrosis, and fibrous content. LV muscle mass decreased significantly by 38% early and 55% late after surgery. Ejection fraction was significantly reduced preoperatively and did not change after AVR (P=NS). LV relaxation was significantly prolonged before surgery (89+/-28 ms) but was normalized late after AVR (42+/-14 ms). Early and late peak filling rates were increased preoperatively but normalized postoperatively. Diastolic stiffness constant was increased before surgery (22+/-6 versus 9+/-3 in control subjects; P=0.0003) and remained elevated early and late after AVR (23+/-4; P=0.002). Muscle fiber diameter decreased significantly after AVR but remained increased at late follow-up. Interstitial fibrosis was increased preoperatively and increased even further early but decreased late after AVR. Fibrosis was positively linearly correlated to myocardial stiffness and inversely correlated to LV ejection fraction. CONCLUSIONS: Patients with aortic regurgitation show normalization of macroscopic LV hypertrophy late after AVR, although fiber hypertrophy persists. These changes in LV myocardial structure late after AVR are accompanied by a change in passive elastic properties with persistent diastolic dysfunction.
Resumo:
Aims: We aimed to assess the impact of B-type natriuretic peptide (BNP) on short-term outcomes in patients undergoing transcatheter aortic valve implantation (TAVI). Methods and results: Of 500 consecutive patients with severe aortic stenosis undergoing TAVI at our institution, we studied 340 patients who had a BNP assessment prior to TAVI. Patients were divided into tertiles - low: BNP ≤201 pg/mL (n=114), mid: BNP 202-595 pg/mL (n=113) and high: BNP ≥596 pg/mL (n=113). The primary endpoint was all-cause mortality, cardiac death and major adverse cardiac and cerebrovascular events (MACCE; death, major stroke and myocardial infarction) at 30 days. Compared with low tertile, high tertile patients were at higher baseline surgical risk (STS score 5.5±3.0 vs. 7.4±4.1, p=0.002). On echocardiography, high tertile patients had smaller valve areas (0.74±0.21 vs. 0.66±0.23 cm2, p=0.008), higher left ventricular (LV) mass indices (123.40±33.66 vs. 168.22±47.96 g/m2, p<0.001) and lower LV ejection fractions (61.59±7.18 vs. 42.65±15.41%, p<0.001) as compared with low tertile patients. At 30 days, a significantly higher incidence of death (hazard ratio [HR] 7.41, p=0.001) cardiac death (HR 5.82, p=0.006) and MACCE (HR 9.04, p<0.001) was observed among high as compared to low tertile patients. Conclusions: In TAVI patients, higher BNP values at baseline are associated with an increased risk for an adverse event periprocedurally and after 30 days, respectively.
Resumo:
OBJECTIVES The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy. BACKGROUND Since its commercialization in 2007, the number of TAVR procedures has grown exponentially. METHODS The adoption of TAVR was investigated in 11 European countries: Germany, France, Italy, United Kingdom, Spain, the Netherlands, Switzerland, Belgium, Portugal, Denmark, and Ireland. Data were collected from 2 sources: 1) lead physicians submitted nation-specific registry data; and 2) an implantation-based TAVR market tracker. Economic indexes such as healthcare expenditure per capita, sources of healthcare funding, and reimbursement strategies were correlated to TAVR use. Furthermore, we assessed the extent to which TAVR has penetrated its potential patient population. RESULTS Between 2007 and 2011, 34,317 patients underwent TAVR. Considerable variation in TAVR use existed across nations. In 2011, the number of TAVR implants per million individuals ranged from 6.1 in Portugal to 88.7 in Germany (33 ± 25). The annual number of TAVR implants performed per center across nations also varied widely (range 10 to 89). The weighted average TAVR penetration rate was low: 17.9%. Significant correlation was found between TAVR use and healthcare spending per capita (r = 0.80; p = 0.005). TAVR-specific reimbursement systems were associated with higher TAVR use than restricted systems (698 ± 232 vs. 213 ± 112 implants/million individuals ≥ 75 years; p = 0.002). CONCLUSIONS The authors' findings indicate that TAVR is underutilized in high and prohibitive surgical risk patients with severe aortic stenosis. National economic indexes and reimbursement strategies are closely linked with TAVR use and help explain the inequitable adoption of this therapy.
Resumo:
Transcatheter aortic valve replacement (TAVR) constitutes a relatively new treatment option for the patients with severe symptomatic aortic stenosis. Evidence from registries and randomized control trials has underscored the value of this treatment in inoperable and high risk populations, while new developments in valve technology and TAVR enabling devices have reduced the risk of complications, simplified the procedure, and broadened the applications of this therapy. The initial promising clinical results and the potential of an effective less invasive treatment of aortic stenosis has not only created high expectations but also the need to address the pitfalls of TAVR technology. The evolving knowledge concerning the groups of patients who would benefit from this treatment, the limited long term follow-up data, the concerns about devices' long term durability, and the severity of complications remain important caveats which restrict the widespread clinical adoption of TAVR. The aim of this review article is to present the recent advances, highlight the limitations of TAVR technology, and discuss the future perspectives in this rapidly evolving field.
Resumo:
OBJECTIVES The aim of the current Valve Academic Research Consortium (VARC)-2 initiative was to revisit the selection and definitions of transcatheter aortic valve implantation (TAVI) clinical endpoints to make them more suitable to the present and future needs of clinical trials. In addition, this document is intended to expand the understanding of patient risk stratification and case selection. BACKGROUND A recent study confirmed that VARC definitions have already been incorporated into clinical and research practice and represent a new standard for consistency in reporting clinical outcomes of patients with symptomatic severe aortic stenosis (AS) undergoing TAVI. However, as the clinical experience with this technology has matured and expanded, certain definitions have become unsuitable or ambiguous. METHODS AND RESULTS Two in-person meetings (held in September 2011 in Washington, DC, and in February 2012 in Rotterdam, The Netherlands) involving VARC study group members, independent experts (including surgeons, interventional and noninterventional cardiologists, imaging specialists, neurologists, geriatric specialists, and clinical trialists), the US Food and Drug Administration (FDA), and industry representatives, provided much of the substantive discussion from which this VARC-2 consensus manuscript was derived. This document provides an overview of risk assessment and patient stratification that need to be considered for accurate patient inclusion in studies. Working groups were assigned to define the following clinical endpoints: mortality, stroke, myocardial infarction, bleeding complications, acute kidney injury, vascular complications, conduction disturbances and arrhythmias, and a miscellaneous category including relevant complications not previously categorized. Furthermore, comprehensive echocardiographic recommendations are provided for the evaluation of prosthetic valve (dys)function. Definitions for the quality of life assessments are also reported. These endpoints formed the basis for several recommended composite endpoints. CONCLUSIONS This VARC-2 document has provided further standardization of endpoint definitions for studies evaluating the use of TAVI, which will lead to improved comparability and interpretability of the study results, supplying an increasingly growing body of evidence with respect to TAVI and/or surgical aortic valve replacement. This initiative and document can furthermore be used as a model during current endeavors of applying definitions to other transcatheter valve therapies (for example, mitral valve repair).
Resumo:
Transcatheter aortic valve implantation (TAVI) is a disruptive technology as it satisfies a previously unmet need which is associated with a profound therapeutic benefit. In randomized clinical trials, TAVI has been shown to improve survival compared with medical treatment among patients considered not suitable candidates for surgical aortic valve replacement (SAVR), and to provide similar outcomes as SAVR in selected high-risk patients. Currently, TAVI is limited to selected elderly patients with symptomatic severe aortic stenosis. As this patient population frequently suffers from comorbid conditions, which may influence outcomes, the selection of patients to undergo TAVI underlies a complex decision process. Several clinical risk score algorithms are routinely used, although they fall short to fully appreciate the true risk among patients currently referred for TAVI. Beyond traditional risk scores, the clinical assessment by an interdisciplinary Heart Team as well as detailed imaging of the aortic valve, aortic root, descending and abdominal aorta as well as peripheral vasculature are important prerequisites to plan a successful procedure. This review will familiarize the reader with the concepts of the interdisciplinary Heart team, risk scores as well as the most important imaging algorithms suited to select appropriate TAVI patients.
Resumo:
Coronary artery disease (CAD) and aortic stenosis (AS) share pathophysiological mechanisms and risk factors. Moreover, the prevalence of CAD increases among elderly patients with severe AS since disease progression is strongly associated with age for both CAD and AS. These factors contribute to the frequent coexistence of CAD and AS. Patients with concomitant AS and CAD are characterised by higher baseline risk profiles with a larger number of comorbidities as compared to patients with isolated AS. Therefore, adequate therapeutic strategies are crucial for the treatment of these patients. The number of patients undergoing concomitant coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) doubled during the last decade. Moreover, the development and rapid integration of transcatheter aortic valve implantation (TAVI) into clinical practice in western European countries has further extended invasive treatment of AS to elderly high-risk patients not considered suitable candidates for SAVR, frequently presenting with CAD. The aim of this review article is to provide an overview on CAD prevalence, impact on clinical outcomes, and treatment strategies in patients with severe AS requiring SAVR or TAVI.
Resumo:
Transcatheter aortic valve implantation (TAVI) is a widely accepted alternative to surgical aortic valve replacement (SAVR) among non-operable patients or selected high-risk patients with degenerative, severe aortic stenosis. TAVI is considered less invasive when compared with SAVR; however, there remain significant differences between different TAVI access routes. The transfemoral approach is considered the least invasive access route, and can be performed as a fully percutaneous procedure in a spontaneously breathing patient under local anaesthesia and mild sedation only. Moreover, transfemoral TAVI patients are typically transferred to coronary care rather than to an intensive care unit after the procedure, and benefit from early ambulation and a reduction in overall length of hospital stay. Considering these patient-specific and health-economic advantages, several TAVI centres follow the least invasive strategy for their patients and have implemented the transfemoral access route as the default access in their institutions. This article provides an overview on the prerequisites for a successful transfemoral TAVI procedure, describes the procedural advantages compared to alternative access routes, and highlights differences in clinical outcomes.
Resumo:
Background Atrioventricular (AV) conduction disturbances requiring permanent pacemaker (PPM) implantation may complicate transcatheter aortic valve replacement (TAVR). Available evidence on predictors of PPM is sparse and derived from small studies. Objectives The objective of this study was to provide summary effect estimates for clinically useful predictors of PPM implantation after TAVR. Methods We performed a systematic search for studies that reported the incidence of PPM implantation after TAVR and that provided raw data for the predictors of interest. Data on study, patient, and procedural characteristics were abstracted. Crude risk ratios (RRs) and 95% confidence intervals for each predictor were calculated by use of random effects models. Stratified analyses by type of implanted valve were performed. Results We obtained data from 41 studies that included 11,210 TAVR patients, of whom 17% required PPM implantation after intervention. The rate of PPM ranged from 2% to 51% in individual studies (with a median of 28% for the Medtronic CoreValve Revalving System [MCRS] and 6% for the Edwards SAPIEN valve [ESV]). The summary estimates indicated increased risk of PPM after TAVR for men (RR: 1.23; p < 0.01); for patients with first-degree AV block (RR: 1.52; p < 0.01), left anterior hemiblock (RR: 1.62; p < 0.01), or right bundle branch block (RR: 2.89; p < 0.01) at baseline; and for patients with intraprocedural AV block (RR: 3.49; p < 0.01). These variables remained significant predictors when only patients treated with the MCRS bioprosthesis were considered. The data for ESV were limited. Unadjusted estimates indicated a 2.5-fold higher risk for PPM implantation for patients who received the MCRS than for those who received the ESV. Conclusions Male sex, baseline conduction disturbances, and intraprocedural AV block emerged as predictors of PPM implantation after TAVR. This study provides useful tools to identify high-risk patients and to guide clinical decision making before and after intervention.