988 resultados para panoramic radiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An X-ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two-dimensional (2-D) packed bed. A medical diagnostic X-ray unit has been used to image the local holdups in a 2-D cold model having a random packing of expanded polystyrene beads. An aqueous barium chloride solution was used as a fluid to achieve good contrast on X-ray images. To quantify the local liquid holdup, a simple calibration technique has been developed that can be used for most of the radiological methods such as gamma ray and neutron radiography. The global value of total liquid holdup, obtained by X-ray method, has been compared with two conventional methods: drainage and tracer response. The X-ray technique, after validation, has been used to visualize and quantify, the liquid hysteresis phenomena in a packed bed. The liquid flows in preferred paths or channels that carry droplets/rivulets of increasing size and number as the liquid flow rate is increased. When the flow is reduced, these paths are retained and the higher liquid holdup that persists in these regions leads to the holdup hysteresis effect. Holdup in some regions of the packed bed may be an order of magnitude higher than average at a particular flow rate. (c) 2005 American Institute of Chemical Engineers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis reports on the development of a technique to evaluate hydraulic conductivities in a soil (Snowcal) subject to freezing conditions. The technique draws on three distinctly different disciplines, Nuclear Physics, Soil Physics and Remote Sensing to provide a non-destructive and reliable evaluation of hydraulic conductivity throughout a freezing test. Thermal neutron radiography is used to provide information on local water/ice contents at anytime throughout the test. The experimental test rig is designed so that the soil matrix can be radiated by a neutron beam, from a nuclear reactor, to obtain radiographs. The radiographs can then be interpreted, following a process of remote sensing image enhancement, to yield information on relative water/ice contents. Interpretation of the radiographs is accommodated using image analysis equipment capable of distinguishing between 256 shades of grey. Remote sensing image enhancing techniques are then employed to develop false colour images which show the movement of water and development of ice lenses in the soil. Instrumentation is incorporated in the soil in the form of psychrometer/thermocouples, to record water potential, electrical resistance probes to enable ice and water to be differentiated on the radiographs and thermocouples to record the temperature gradient. Water content determinations are made from the enhanced images and plotted against potential measurements to provide the moisture characteristic for the soil. With relevant mathematical theory pore water distributions are obtained and combined with water content data to give hydraulic conductivities. The values for hydraulic conductivity in the saturated soil and at the frozen fringe are compared with established values for silts and silty-sands. The values are in general agreement and, with refinement, this non-destructive technique could afford useful information on a whole range of soils. The technique is of value over other methods because ice lenses are actually seen forming in the soil, supporting the accepted theories of frost action. There are economic and experimental restraints to the work which are associated with the use of a nuclear facility, however, the technique is versatile and has been applied to the study of moisture transfer in porous building materials and could be further developed into other research areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the predictive merits of selected cognitive and noncognitive variables on the national Registry exam pass rate using 2008 graduates (n = 175) from community college radiography programs in Florida. The independent variables included two GPAs, final grades in five radiography courses, self-efficacy, and social support. The dependent variable was the first-attempt results on the national Registry exam. The design was a retrospective predictive study that relied on academic data collected from participants using the self-report method and on perceptions of students' success on the national Registry exam collected through a questionnaire developed and piloted in the study. All independent variables except self-efficacy and social support correlated with success on the national Registry exam ( p < .01) using the Pearson Product-Moment Correlation analysis. The strongest predictor of the national Registry exam success was the end-of-program GPA, r = .550, p < .001. The GPAs and scores for self-efficacy and social support were entered into a logistic regression analysis to produce a prediction model. The end-of-program GPA (p = .015) emerged as a significant variable. This model predicted 44% of the students who failed the national Registry exam and 97.3% of those who passed, explaining 45.8% of the variance. A second model included the final grades for the radiography courses, self efficacy, and social support. Three courses significantly predicted national Registry exam success; Radiographic Exposures, p < .001; Radiologic Physics, p = .014; and Radiation Safety & Protection, p = .044, explaining 56.8% of the variance. This model predicted 64% of the students who failed the national Registry exam and 96% of those who passed. The findings support the use of in-program data as accurate predictors of success on the national Registry exam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FAPESP:95/02610

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Panoramic Sea Happening (After Kantor) is a 7 minute durational film that reimagines part of Tadeusz Kantor's original sea happenings from 1967 in a landscape in which the sea has retreated. The conductor of Kantor’s original performance is replaced with a sound object cast adrift on a beach in Dungeness (UK). The object plays back the sound of the sea into the landscape, which was performed live and then filmed from three distinct angles. The first angle mimics the position of the conductor in Kantor’s original happening, facing outwards into the horizon of the beach and recalls the image in Kantor’s work of a human figure undertaking the absurd task of orchestrating the sound of a gigantic expanse of water. The second angle exposes the machine itself and the large cone that amplifies the sound, reinforcing the isolation of the object. The third angle reveals a decommissioned nuclear power station and sound objects used as a warning system for the power plant. Dungeness is a location where the sea has been retreating from the land, leaving traces of human activity through the disused boat winches, abandoned cabins and the decommissioned nuclear buildings. It is a place in which the footprint of the anthropocene is keenly felt. The sound object is intended to act as an anthropomorphic figure, ghosting the original conductor and offering the sound of the sea back into the landscape through a wide mouthpiece, echoing Kantor’s own load hailer in the original sequence of sea happenings. It speculates on Kantor's theory of the bio-object, which proposed a symbiotic relationship between the human and the nonhuman object in performance, as a possible instrument to access a form of geologic imagination. In this configuration, the human itself is absent, but is evoked through the objects left behind. The sound object, helpless in a red dingy, might be thought of as a co-conspirator with the viewer, enabling a looking back to the past in a landscape of an inevitable future. The work was originally commissioned by the University of Kent in collaboration with the Polish Cultural Institute for the Symposium Kantorbury Kantorbury in Canterbury (UK) to mark the 100 years since Tadeusz Kantor’s birth (15 - 19 September 2015). It should be projected and requires stereo speakers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

2016 is the outbreak year of the virtual reality industry. In the field of virtual reality, 3D surveying plays an important role. Nowadays, 3D surveying technology has received increasing attention. This project aims to establish and optimize a WebGL three-dimensional broadcast platform combined with streaming media technology. It takes streaming media server and panoramic video broadcast in browser as the application background. Simultaneously, it discusses about the architecture from streaming media server to panoramic media player and analyzing relevant theory problem. This paper focuses on the debugging of streaming media platform, the structure of WebGL player environment, different types of ball model analysis, and the 3D mapping technology. The main work contains the following points: Initially, relay on Easy Darwin open source streaming media server, built a streaming service platform. It can realize the transmission from RTSP stream to streaming media server, and forwards HLS slice video to clients; Then, wrote a WebGL panoramic video player based on Three.js lib with JQuery browser playback controls. Set up a HTML5 panoramic video player; Next, analyzed the latitude and longitude sphere model which from Three.js library according to WebGL rendering method. Pointed out the drawbacks of this model and the breakthrough point of improvement; After that, on the basis of Schneider transform principle, established the Schneider sphere projection model, and converted the output OBJ file to JS file for media player reading. Finally implemented real time panoramic video high precision playing without plugin; At last, I summarized the whole project. Put forward the direction of future optimization and extensible market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical mapping of voltage signals has revolutionised the field and study of cardiac electrophysiology by providing the means to visualise changes in electrical activity at a high temporal and spatial resolution from the cellular to the whole heart level under both normal and disease conditions. The aim of this thesis was to develop a novel method of panoramic optical mapping using a single camera and to study myocardial electrophysiology in isolated Langendorff-perfused rabbit hearts. First, proper procedures for selection, filtering and analysis of the optical data recorded from the panoramic optical mapping system were established. This work was followed by extensive characterisation of the electrical activity across the epicardial surface of the preparation investigating time and heart dependent effects. In an initial study, features of epicardial electrophysiology were examined as the temperature of the heart was reduced below physiological values. This manoeuvre was chosen to mimic the temperatures experienced during various levels of hypothermia in vivo, a condition known to promote arrhythmias. The facility for panoramic optical mapping allowed the extent of changes in conduction timing and pattern of ventricular activation and repolarisation to be assessed. In the main experimental section, changes in epicardial electrical activity were assessed under various pacing conditions in both normal hearts and in a rabbit model of chronic MI. In these experiments, there was significant changes in the pattern of electrical activation corresponding with the changes in pacing regime. These experiments demonstrated a negative correlation between activation time and APD, which was not maintained during ventricular pacing. This suggests that activation pattern is not the sole determinant of action potential duration in intact hearts. Lastly, a realistic 3D computational model of the rabbit left ventricle was developed to simulate the passive and active mechanical properties of the heart. The aim of this model was to infer further information from the experimental optical mapping studies. In future, it would be feasible to gain insight into the electrical and mechanical performance of the heart by simulating experimental pacing conditions in the model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to correlate the pre-operative imaging, vascularity of the proximal pole, and histology of the proximal pole bone of established scaphoid fracture non-union. This was a prospective non-controlled experimental study. Patients were evaluated pre-operatively for necrosis of the proximal scaphoid fragment by radiography, computed tomography (CT) and magnetic resonance imaging (MRI). Vascular status of the proximal scaphoid was determined intra-operatively, demonstrating the presence or absence of puncate bone bleeding. Samples were harvested from the proximal scaphoid fragment and sent for pathological examination. We determined the association between the imaging and intra-operative examination and histological findings. We evaluated 19 male patients diagnosed with scaphoid nonunion. CT evaluation showed no correlation to scaphoid proximal fragment necrosis. MRI showed marked low signal intensity on T1-weighted images that confirmed the histological diagnosis of necrosis in the proximal scaphoid fragment in all patients. Intra-operative assessment showed that 90% of bones had absence of intra-operative puncate bone bleeding, which was confirmed necrosis by microscopic examination. In scaphoid nonunion MRI images with marked low signal intensity on T1-weighted images and the absence of intra-operative puncate bone bleeding are strong indicatives of osteonecrosis of the proximal fragment.