958 resultados para pH-sensistivity


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ja fa varies decades que els conservadors-restauradors de paper van comenc;ar a tenir en compteel pH de les obres que tractaven, ja que es va veure que I'acidesa incidia molt directament en comde rapid I'objecte es debilitava mecimicament. De fet, trobem tant aviat com el 1936, una patenten registrada per OJ. Schierholtz per desacidificar el paper d'empaperar parets (Porck, 1996).La tela d'un quadre, essent un teixit fet a base de fibres vegetals compastes majoritariament perceHulosa, com les fibres del paper, és lógicament també facilment degradable si I'ambient ñes acid(te un baix pH).Sorprenentment, pero, I'acidesa de la tela deis quadres, tot i que en ocasions puntuals ha estatanalitzada (Bajocchi, 2009; Young, 1999), encara no és un parametre que es miri de forma rutinariai per tant, fins recentment, no se sabia quins eren els valors de pH més típics que pot tenir unquadre.Aquest estudi és una primera recopilació sistematica d'aquest t ipus d' in formació per a partir d'aquícrear un banc de dades que vagi recollint aquest t ipus d'informació sobre el majar nombre possiblede quadres.Si I'acidesa present en la tela ens indica com de rapid es degradara aquesta en el futur, la mesura delgrau de polimerització de la tela (DP), ens indica si la tela té una al ta o baixa resistencia mecanica enel moment actual. Així doncs, aquests dos parametres ens aporten informació molt úti l sobre I'estatde conserva ció del suportoAquesta recerca pretén respondre a les preguntes de quins són els valors de pH i DP que típicamentpodem trabar en la tela deis quadres, així com analitzar la relació entre aquests dos parametres i també la relació entre la data de producció deis quadres i els valors de pH i DP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ja fa varies decades que els conservadors-restauradors de paper van comenc;ar a tenir en compteel pH de les obres que tractaven, ja que es va veure que I'acidesa incidia molt directament en comde rapid I'objecte es debilitava mecimicament. De fet, trobem tant aviat com el 1936, una patenten registrada per OJ. Schierholtz per desacidificar el paper d'empaperar parets (Porck, 1996).La tela d'un quadre, essent un teixit fet a base de fibres vegetals compastes majoritariament perceHulosa, com les fibres del paper, és lógicament també facilment degradable si I'ambient ñes acid(te un baix pH).Sorprenentment, pero, I'acidesa de la tela deis quadres, tot i que en ocasions puntuals ha estatanalitzada (Bajocchi, 2009; Young, 1999), encara no és un parametre que es miri de forma rutinariai per tant, fins recentment, no se sabia quins eren els valors de pH més típics que pot tenir unquadre.Aquest estudi és una primera recopilació sistematica d'aquest t ipus d' in formació per a partir d'aquícrear un banc de dades que vagi recollint aquest t ipus d'informació sobre el majar nombre possiblede quadres.Si I'acidesa present en la tela ens indica com de rapid es degradara aquesta en el futur, la mesura delgrau de polimerització de la tela (DP), ens indica si la tela té una al ta o baixa resistencia mecanica enel moment actual. Així doncs, aquests dos parametres ens aporten informació molt úti l sobre I'estatde conserva ció del suportoAquesta recerca pretén respondre a les preguntes de quins són els valors de pH i DP que típicamentpodem trabar en la tela deis quadres, així com analitzar la relació entre aquests dos parametres i també la relació entre la data de producció deis quadres i els valors de pH i DP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of casein concentration, Ca2+ concentration, temperature and pH on the amount and size of protein aggregates (fines) in the whey produced by enzimic coagulation of nonfat milk was studied in laboratory conditions. Casein concentrations about 0.3 g/L showed a minimal amount of caseins in the whey, with presence of small aggregates of casein micellles. Ca2+ concentrations higher than 5 mM were neccesary to reduce the whey protein to a minimum constituted by protein particles smaller than casein micelles. The coagulation temperature, in the 35 - 45oC range, produced almost no variations in the whey proteins. The obtention of a minimum amount of whey proteins was possible only in a narrow pH range around 6.4. These results pointed to casein concentration and pH as important variables to be controlled in connection with the process yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unexpected low yield in the Appel's synthesis of PPh2Si(CH3)3 can be attributed to the presence of phenyllithium and its interfering reactions. The method was carried out with hydrolysis of the products formed by the reaction of PPh3 with metallic lithium, phenyllithium and lithiumdiphenylphosphide. PPh2Si(CH3)3 was obtained by subsequent reaction of the resulting diphenylphosphin with elemental lithium and ClSi(CH3)3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the fruit extracts of Morus nigra - mulberry, Syzygium cuminii - jambolão, Vitis vinifera ¾ grape, Myrciaria cauliflora - jabuticaba are suggested as pH indicators in the form of either solutions or paper. The pH indicator solutions were prepared by soaking the fruits or their peels in ethanol 1:3 (m/V) for 24 h, followed by simple filtration. The pH indicator papers were prepared by imersion of the qualitative filter paper strips in the pH indicator solutions. The different pH leads to color changes in the indicator solutions or papers and it can be used for teaching elementary chemistry concepts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acidic hydrolysis of samples is frequent in urinary 2,5-hexanodione determination. This hydrolysis should be performed under proper conditions, in order to avoid interference, such as the presence of 2,5-dimethylfurane and 2-acetylfurane. The results of the present work, as well as data from the literature, show that the use of non-polar or slightly polar chromatographic columns of 30 m length is an essential condition for 2,5-HD determination in an acid hydrolysed urine sample. In the same way the pH should be kept between 0.3 and 0.5. The mean concentrations of 2,5-HD in samples submitted to hydrolysis (0.50 ± 0.28 mg/g of creatinine) was about 3 times higher than those found in the samples without acid hydrolysis (0.19 ± 0.3 mg/g of creatinine).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some commercial samples of vermicompost from bovine manure (humus) were characterized by thermogravimetry with respect to humidity, organic matter and ash contents, the percentages of which range from 6.55 to 5.35%, 53.01 to 69.96% and 46.44 to 66,14%, respectively. The capacity of adsorption of Cu2+, Zn2+ and Co2+ ions by these samples has been evaluated as a function of pH and time. The contents of several metal ions in the original vermicompost samples have been determined by flame atomic absorption spectrometry after digestion in a microwave oven. The high nitrogen content suggests that the earthworms used in the maturation procedure lead to an efficient degradation of organic matter. The metal retention was affected by both pH and adsorption time. The results also show that adsorption follows the order Cu2+ > Zn2+ > Co2+.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of biomolecules to catalyze chemical reactions is due chiefly to their sensitivity to variations of the pH in the surrounding environment. The reason for this is that they are made up of chemical groups whose ionization states are modulated by pH changes that are of the order of 0.4 units. The determination of the protonation states of such chemical groups as a function of conformation of the biomolecule and the pH of the environment can be useful in the elucidation of important biological processes from enzymatic catalysis to protein folding and molecular recognition. In the past 15 years, the theory of Poisson-Boltzmann has been successfully used to estimate the pKa of ionizable sites in proteins yielding results, which may differ by 0.1 unit from the experimental values. In this study, we review the theory of Poisson-Boltzmann under the perspective of its application to the calculation of pKa in proteins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cation exchange capabilities of a Brazilian natural zeolite, identified as scolecite, were evaluated for application in wastewater control. We investigated the process of sorption of chromium(III), nickel(II), cadmium(II) and manganese(II) in synthetic aqueous effluents, including adsorption isotherms of single-metal solutions. The natural zeolite showed the ability to take up the tested heavy metals in the order Cr(III) > Cd(II) > Ni(II) > Mn(II), and this could be related to the valence and the hydration radius of the metal cations. The influence of temperature (25, 40 and 60 ºC) and initial pH value (from 4 to 6) was also evaluated. It was found that the adsorption increased substantially when the temperature was raised to 60 ºC and that maximum adsorption capacity was observed at pH 6. These results demonstrate that scolecite can be used for removal of heavy metals from aqueous effluents, under optimized conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour of Nafion® polymeric membranes containing acid-base dyes, bromothymol blue (BB) and methyl violet (MV), were studied aiming at constructing an optical sensor for pH measurement. BB revealed to be inadequate for developing sensing phases due to the electrostatic repulsion between negative groups of their molecules and the negative charge of the sulfonate group of the Nafion®, which causes leaching of the dye from the membrane. On the other hand, MV showed to be suitable due to the presence of positive groups in its structure. The membrane prepared from a methanolic solution whose Nafion®/dye molar ratio was 20 presented the best analytical properties, changing its color from green to violet in the pH range from 0.6 to 3.0. The membrane can be prepared with good reproducibility, presenting durability of ca. 6 months and response time of 22 s, making possible its use for pH determination in flow analysis systems.