938 resultados para neutron emission width
Resumo:
We reanalyze the decay mode of Lambda hypernuclei induced by two nucleons modifying previous numerical results and the interpretation of the process. The repercussions of this channel in the ratio of neutron to proton induced Lambda decay is studied in detail in connection with the present experimental data. This leads to ratios that are in greater contradiction with usual one pion exchange models than those deduced before.
Resumo:
This clinical study was based on experimental results obtained in nude mice grafted with human colon carcinoma, showing that injected 131I-labeled F(ab')2 and Fab fragments from high affinity anti-carcinoembryonic antigen (CEA) monoclonal antibodies (MAb) gave markedly higher ratios of tumor to normal tissue localization than intact MAb. 31 patients with known colorectal carcinoma, including 10 primary tumors, 13 local tumor recurrences, and 21 metastatic involvements, were injected with 123I-labeled F(ab')2 (n = 14) or Fab (n = 17) fragments from MAb anti-CEA. The patients were examined by emission-computerized tomography (ECT) at 6, 24, and sometimes 48 h after injection using a rotating dual head scintillation camera. All 23 primary tumors and local recurrences except one were clearly visualized on at least two sections of different tomographic planes. Interestingly, nine of these patients had almost normal circulating CEA levels, and three of the visualized tumors weighed only 3-5 g. Among 19 known metastatic tumor involvements, 14 were correctly localized by ECT. Two additional liver and several bone metastases were discovered by immunoscintigraphy. Altogether, 86% of the tumor sites were detected, 82% with F(ab')2 and 89% with Fab fragments. The contrast of the tumor images obtained with Fab fragments suggests that this improved method of immunoscintigraphy has the potential to detect early tumor recurrences and thus to increase the survival of patients. The results of this retrospective study, however, should be confirmed in a prospective study before this method can be recommended for the routine diagnosis of cancer.
Resumo:
A Comment on the Letter by Mark Mineev-Weinstein, Phys. Rev. Lett. 80, 2113 (1998). The authors of the Letter offer a Reply.
Resumo:
Acoustic emission avalanche distributions are studied in different alloy systems that exhibit a phase transition from a bcc to a close-packed structure. After a small number of thermal cycles through the transition, the distributions become critically stable (exhibit power-law behavior) and can be characterized by an exponent alpha. The values of alpha can be classified into universality classes, which depend exclusively on the symmetry of the resulting close-packed structure.
Resumo:
OBJECTIVE: To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the assessment of pleural abnormalities in cancer patients. METHODS: A comprehensive literature search of studies published through June 2013 regarding the role of (18)F-FDG-PET and PET/CT in evaluating pleural abnormalities in cancer patients was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG-PET or PET/CT on a per patient-based analysis were calculated. The area under the summary ROC curve (AUC) was calculated to measure the accuracy of these methods in the assessment of pleural abnormalities. Sub-analyses considering (18)F-FDG-PET/CT and patients with lung cancer only were carried out. RESULTS: Eight studies comprising 360 cancer patients (323 with lung cancer) were included. The meta-analysis of these selected studies provided the following results: sensitivity 86% [95% confidence interval (95%CI): 80-91%], specificity 80% [95%CI: 73-85%], LR+ 3.7 [95%CI: 2.8-4.9], LR- 0.18 [95%CI: 0.09-0.34], DOR 27 [95%CI: 13-56]. The AUC was 0.907. No significant improvement considering PET/CT studies only and patients with lung cancer was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of pleural abnormalities in cancer patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. The literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited and prospective studies are needed.
Resumo:
We study the (K-, p) reaction on nuclei with a 1 GeV/c momentum kaon beam, paying special attention to the region of emitted protons having kinetic energy above 600 MeV, which was used to claim a deeply attractive kaon nucleus optical potential. Our model describes the nuclear reaction in the framework of a local density approach and the calculations are performed following two different procedures: one is based on a many-body method using the Lindhard function and the other is based on a Monte Carlo simulation. The simulation method offers flexibility to account for processes other than kaon quasielastic scattering, such as K- absorption by one and two nucleons, producing hyperons, and allows consideration of final-state interactions of the K-, the p, and all other primary and secondary particles on their way out of the nucleus, as well as the weak decay of the produced hyperons into pi N. We find a limited sensitivity of the cross section to the strength of the kaon optical potential. We also show a serious drawback in the experimental setup-the requirement for having, together with the energetic proton, at least one charged particle detected in the decay counter surrounding the target-as we find that the shape of the original cross section is appreciably distorted, to the point of invalidating the claims made in the experimental paper on the strength of the kaon nucleus optical.
Resumo:
Neutron diffraction has been used to study in situ the nanocrystallization process of Fe73.5Cu1Nb3Si22.5-xBx (x = 5, 9, and 12) amorphous alloys. Nanocrystallization results in a decrease of both the silicon content and the grain size of the Fe(Si) phase with increasing value of x. By comparing the radial distribution function peak areas with those predicted for ideal bcc and DO3 structure, it can be concluded that the ordering in DO3 Fe(Si) crystals increases with the silicon content.
Resumo:
Measurements and simulations were performed to assess workers' exposure to solvent vapors and aerosols during the waterproofing of a tiled surface. This investigation followed two recent incidents in the same company where workers experienced acute respiratory illness after spraying a stain-repellent resin containing fluorinated polymers on stone-tiled walls and floors. Because the waterproofing activity had been done for years at the tile company without encountering any exposure problems prior to these cases, it was strongly suspected that the incidents were linked to a recent change in the composition of the coating mixture. Experimental measurements and simulations indicated that the emission rate of particles smaller than 10 microm may be estimated at 0.66 mg/sec (SD 0.10) for the old resin and at 0.37 mg/sec (SD 0.04) for the new one. The measurement of the solvent emission rate from surfaces coated with the two resins indicated that shortly after spraying, the emission was in the range of 18 to 20 mg/sec x m2 and was similar for both products. Solvent and overspray emission rates were introduced in a two-zone compartment model. The results obtained in the near-field indicate significant exposure to overspray mist (7 and 34 mg/m3 for new resin) and solvent vapors (80 to 350 ppm for the new resin). It was also shown that the introduction of the new resin tended to significantly decrease the levels of solvents and particulates in the workers' breathing zone. These results strongly suggest that cases of acute respiratory illness are related to the specific toxicity of the fluorinated polymer itself. The fact that the same polymer is used in various commercial products raises concern regarding other possible occupational and domestic exposures.
Resumo:
The photoproduction of η′η′-mesons off different nuclei has been measured with the CBELSA/TAPS detector system for incident photon energies between 15002200 MeV. The transparency ratio has been deduced and compared to theoretical calculations describing the propagation of η′η′-mesons in nuclei. The comparison indicates a width of the η′η′-meson of the order of Γ=1525 MeVΓ=1525 MeV at ρ=ρ0ρ=ρ0 for an average momentum pη′=1050 MeV/cpη′=1050 MeV/c, at which the η′η′-meson is produced in the nuclear rest frame. The inelastic η′Nη′N cross section is estimated to be 310 mb. Parameterizing the photoproduction cross section of η′η′-mesons by σ(A)=σ0Aασ(A)=σ0Aα, a value of α=0.84±0.03α=0.84±0.03 has been deduced.
Resumo:
We study whether the neutron skin thickness Δrnp of 208Pb originates from the bulk or from the surface of the nucleon density distributions, according to the mean-field models of nuclear structure, and find that it depends on the stiffness of the nuclear symmetry energy. The bulk contribution to Δrnp arises from an extended sharp radius of neutrons, whereas the surface contribution arises from different widths of the neutron and proton surfaces. Nuclear models where the symmetry energy is stiff, as typical of relativistic models, predict a bulk contribution in Δrnp of 208Pb about twice as large as the surface contribution. In contrast, models with a soft symmetry energy like common nonrelativistic models predict that Δrnp of 208Pb is divided similarly into bulk and surface parts. Indeed, if the symmetry energy is supersoft, the surface contribution becomes dominant. We note that the linear correlation of Δrnp of 208Pb with the density derivative of the nuclear symmetry energy arises from the bulk part of Δrnp. We also note that most models predict a mixed-type (between halo and skin) neutron distribution for 208Pb. Although the halo-type limit is actually found in the models with a supersoft symmetry energy, the skin-type limit is not supported by any mean-field model. Finally, we compute parity-violating electron scattering in the conditions of the 208Pb parity radius experiment (PREX) and obtain a pocket formula for the parity-violating asymmetry in terms of the parameters that characterize the shape of the 208Pb nucleon densities.
Resumo:
Selostus: Maan märkyyden vaikutus ilman koostumukseen ja dityppioksidiemissioon hiuemaassa
Resumo:
A Comment on the Letter by Ubaldo Bafile, et al., Phys. Rev. Lett. 86, 1019 (2001). The authors of the Letter offer a Reply.