793 resultados para needle
Resumo:
In many plant species, leaf morphology varies with altitude, an effect that has been attributed to temperature. It remains uncertain whether such a trend applies equally to juvenile and mature trees across altitudinal gradients in semi-arid mountain regions. We examined altitude-related differences in a variety of needle characteristics of juvenile (2-m tall) and mature (5-m tall) alpine spruce (Picea crassifolia Kom.) trees growing at altitudes between 2501 and 3450 m in the Qilian Mountains of northwest China. We found that stable carbon isotope composition (delta C-13), area- and mass-based leaf nitrogen concentration (N-a, N-m), number of stomata per gram of nitrogen (St/N), number of stomata per unit leaf mass (St/LM), projected leaf area per 100 needles (LA) and leaf mass per unit area (LMA) varied nonlinearly with altitude for both juvenile and mature trees, with a relationship reversal point at about 3 100 m. Stomatal density (SD) of juvenile trees remained unchanged with altitude, whereas SD and stomatal number per unit length (SNL) of mature spruce initially increased with altitude, but subsequently decreased. Although several measured indices were generally found to be higher in mature trees than in juvenile trees, N-m, leaf carbon concentration (C.), leaf water concentration. (LWC), St/N, LA and St/LM showed inconsistent differences between trees of different ages along the altitudinal gradient. In both juvenile and mature trees, VC correlated significantly with LMA, N-m, N-a, SNL, St/LM and St/N. Stomatal density, LWC and LA were only significantly correlated with delta C-13 in mature trees. These findings suggest that there are distinct ecophysiological differences between the needles of juvenile and mature trees that determine their response to changes in altitude in semi-arid mountainous regions. Variations in the fitness of forests of different ages may have important implications for modeling forest responses to changes in environmental conditions, such as predicted future temperature increases in high attitude areas associated with climate change.
Resumo:
The largest mass extinction in the Phanerozoic happened at the end of the Permian. The microbialites formed in the extreme environments after the mass extinction has become a hotspot for geologists and paleontologists throughout the world. The dendroid microbialites that were described for the first time in 1999 from the Permian-Triassic boundary section at Laolongdong, Chongqing, have been studied by many geologists from China and overseas. Two important viewpoints about their origin have been proposed. Some researchers believed that they resemble Quaternary travertine shrubs in form, and may belong to microbialites. Some other researchers proposed that the dendroid structure is composed of clots formed by coccoidal cynaobacteria, and is microbialite. Our detailed survey on the section reveals that: (1) there is an interval of speckled “microbialite” in the section, and it underlies the dendroid “microbialite”, (2) the dendroid “microbialite” does not always have dendroid appearance; they are dendroid only in very local places; they are not dendroid in most places; for this reason, they are not comparable to recent tufa; (3) the volume of the dendroid structure greatly increases toward the top of the dendroid microbialite interval: accounting to 70% of the whole rock in the top part. This distribution pattern implies that the formation of this structure may be related to downward migration of the diagenetic fluid. Examination of thin sections reveals that the dendroid structure or point-like structure in the “microbialite” look as lighter areas in the thin sections and are composed of large blocky clear calcites containing scattered yellow dirty small calcite rhombi and irregular “points” of relict lime mudstone or wackestone or packstone. Their formation is by any one of the following two processes: (1) dissolution → filling of large blocky calcite; (2) dolomitization → dedolomitization → dissolution by meteoric fresh water → filling by large blocky calcites. It has been found that there are at least two sea-level falls during the P-T transition. As the sea level fall, the carbonate deposits came into supratidal environment, and suffered dolomitization caused by evaporative fluid or mixing water of sea water and meteoric water. Since the fluid migrated downward from the top of the deposits and in random pathway, the dolomitization formed dendroid or speckled dolomitic areas. As the deposits came into subaerial environments, the meteoric fresh water migrated along the dendroid or speckled dolomitic area with higher porosity, and dissolution happened, which caused the rock became spongy or alveolate. In later time, after the strata came into phreatic zone, large clear blocky calcites grew in and filled the pores in the spongy areas. The dendroid and speckled structure were formed in this way, rather than composed of clots formed by coccoid cyanobecteria. The microbial fossils in Laolongdong section include two types. The first is the tube-like cyanobecteria in middle Bed 3, which are generally less than 1 mm in length, taper toward one end, and are internally filled by microspars. They are straight or sinuous, with micritic wall 0.005~0.01 mm thick. Since this kind of microbial fossils are abundant in middle Bed 3, this rock belongs to microbialite. The second type occurs in Bed 5 and lower and middle Bed 6. They are irregular globular in shape, generally 0.2 ~ 0.5 mm in size, with several outward progresses, and internally filled by one layer of needle-like calcite cements on the wall and the large blocky calcite in the inner space. According to their shape and preservation way, it is inferred that this kind of fossils were formed from some kind of bacterial colony. The bacterial colony may be cuticle in composition, since it has some hardness as it is indicated by its resistance to deposit loading. These organisms discomposed during diagenetic time, and formed good porosity. In later diagenetic time, these pores were firstly cemented by needle-like calcites and later filled by large blocky calcites. So, the bacterial colony promoted the formation of dendroid and speckled structures. However, they did not always form such structures. On the other hand, even though no bacterial colony or other microbes or any kind of fossils were present, dendroid or speckled structures can form. Bed 4 of Laolongdong section contains abundant gastropods but no microbial fossils, and is not microbialite, even though it is speckled. The top of Bed 6 is dendroid, but contain no microbial fossils, and is not micrbialite.
Resumo:
Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária
Resumo:
This thesis work covered the fabrication and characterisation of impedance sensors for biological applications aiming in particular to the cytotoxicity monitoring of cultured cells exposed to different kind of chemical compounds and drugs and to the identification of different types of biological tissue (fat, muscles, nerves) using a sensor fabricated on the tip of a commercially available needle during peripheral nerve block procedures. Gold impedance electrodes have been successfully fabricated for impedance measurement on cells cultured on the electrode surface which was modified with the fabrication of gold nanopillars. These nanostructures have a height of 60nm or 100nm and they have highly ordered layout as they are fabricated through the e-beam technique. The fabrication of the threedimensional structures on the interdigitated electrodes was supposed to improve the sensitivity of the ECIS (electric cell-substrate impedance sensing) measurement while monitoring the cytotoxicity effects of two different drugs (Antrodia Camphorata extract and Nicotine) on three different cell lines (HeLa, A549 and BALBc 3T3) cultured on the impedance devices and change the morphology of the cells growing on the nanostructured electrodes. The fabrication of the nanostructures was achieved combining techniques like UV lithography, metal lift-off, evaporation and e-beam lithography techniques. The electrodes were packaged using a pressure sensitive, medical grade adhesive double-sided tape. The electrodes were then characterised with the aid of AFM and SEM imaging which confirmed the success of the fabrication processes showing the nanopillars fabricated with the right layout and dimensions figures. The introduction of nanopillars on the impedance electrodes, however, did not improve much the sensitivity of the assay with the exception of tests carried out with Nicotine. HeLa and A549 cells appeared to grow in a different way on the two surfaces, while no differences where noticed on the BALBc 3T3 cells. Impedance measurements obtained with the dead cells on the negative control electrodes or the test electrodes with the drugs can be compared to those done on the electrodes containing just media in the tested volume (as no cells are attached and cover the electrode surface). The impedance figures recorded using these electrodes were between 1.5kΩ and 2.5 kΩ, while the figures recorded on confluent cell layers range between 4kΩ and 5.5kΩ with peaks of almost 7 kΩ if there was more than one layer of cells growing on each other. There was then a very clear separation between the values of living cell compared to the dead ones which was almost 2.5 - 3kΩ. In this way it was very easy to determine whether the drugs affected the cells normal life cycle on not. However, little or no differences were noticed in the impedance analysis carried out on the two different kinds of electrodes using cultured cells. An increase of sensitivity was noticed only in a couple of experiments carried out on A549 cells growing on the nanostructured electrodes and exposed to different concentration of a solution containing Nicotine. More experiments to achieve a higher number of statistical evidences will be needed to prove these findings with an absolute confidence. The smart needle project aimed to reduce the limitations of the Electrical Nerve Stimulation (ENS) and the Ultra Sound Guided peripheral nerve block techniques giving the clinicians an additional tool for performing correctly the peripheral nerve block. Bioimpedance, as measured at the needle tip, provides additional information on needle tip location, thereby facilitating detection of intraneural needle placement. Using the needle as a precision instrument and guidance tool may provide additional information as to needle tip location and enhance safety in regional anaesthesia. In the time analysis, with the frequency fixed at 10kHz and the samples kept at 12°C, the approximate range for muscle bioimpedance was 203 – 616 Ω, the approximate bioimpedance range for fat was 5.02 - 17.8 kΩ and the approximate range for connective tissue was 790 Ω – 1.55 kΩ. While when the samples were heated at 37°C and measured again at 10kHz, the approximate bioimpedance range for muscle was 100-175Ω. The approximate bioimpedance range of fat was 627 Ω - 3.2 kΩ and the range for connective tissue was 221-540Ω. In the experiments done on the fresh slaughtered lamb carcass, replicating a scenario close to the real application, the impedance values recorded for fat were around 17 kΩ, for muscle and lean tissue around 1.3 kΩ while the nervous structures had an impedance value of 2.9 kΩ. With the data collected during this research, it was possible to conclude that measurements of bioimpedance at the needle tip location can give valuable information to the clinicians performing a peripheral nerve block procedure as the separation (in terms of impedance figures) was very marked between the different type of tissues. It is then feasible to use an impedance electrode fabricated on the needle tip to differentiate several tissues from the nerve tissue. Currently, several different methods are being studied to fabricate an impedance electrode on the surface of a commercially available needle used for the peripheral nerve block procedure.
Resumo:
Gemstone Team No More Needles
Resumo:
OBJECTIVES: To compare the predictive performance and potential clinical usefulness of risk calculators of the European Randomized Study of Screening for Prostate Cancer (ERSPC RC) with and without information on prostate volume. METHODS: We studied 6 cohorts (5 European and 1 US) with a total of 15,300 men, all biopsied and with pre-biopsy TRUS measurements of prostate volume. Volume was categorized into 3 categories (25, 40, and 60 cc), to reflect use of digital rectal examination (DRE) for volume assessment. Risks of prostate cancer were calculated according to a ERSPC DRE-based RC (including PSA, DRE, prior biopsy, and prostate volume) and a PSA + DRE model (including PSA, DRE, and prior biopsy). Missing data on prostate volume were completed by single imputation. Risk predictions were evaluated with respect to calibration (graphically), discrimination (AUC curve), and clinical usefulness (net benefit, graphically assessed in decision curves). RESULTS: The AUCs of the ERSPC DRE-based RC ranged from 0.61 to 0.77 and were substantially larger than the AUCs of a model based on only PSA + DRE (ranging from 0.56 to 0.72) in each of the 6 cohorts. The ERSPC DRE-based RC provided net benefit over performing a prostate biopsy on the basis of PSA and DRE outcome in five of the six cohorts. CONCLUSIONS: Identifying men at increased risk for having a biopsy detectable prostate cancer should consider multiple factors, including an estimate of prostate volume.
Resumo:
Commercially available implantable needle-type glucose sensors for diabetes management are robust analytically but can be unreliable clinically primarily due to tissue-sensor interactions. Here, we present the physical, drug release and bioactivity characterization of tubular, porous dexamethasone (Dex)-releasing polyurethane coatings designed to attenuate local inflammation at the tissue-sensor interface. Porous polyurethane coatings were produced by the salt-leaching/gas-foaming method. Scanning electron microscopy and micro-computed tomography (micro-CT) showed controlled porosity and coating thickness. In vitro drug release from coatings monitored over 2 weeks presented an initial fast release followed by a slower release. Total release from coatings was highly dependent on initial drug loading amount. Functional in vitro testing of glucose sensors deployed with porous coatings against glucose standards demonstrated that highly porous coatings minimally affected signal strength and response rate. Bioactivity of the released drug was determined by monitoring Dex-mediated, dose-dependent apoptosis of human peripheral blood derived monocytes in culture. Acute animal studies were used to determine the appropriate Dex payload for the implanted porous coatings. Pilot short-term animal studies showed that Dex released from porous coatings implanted in rat subcutis attenuated the initial inflammatory response to sensor implantation. These results suggest that deploying sensors with the porous, Dex-releasing coatings is a promising strategy to improve glucose sensor performance.
Resumo:
Trauma care in the general population has largely become protocol-driven, with an emphasis on fast and efficient treatment, good team communication at all levels of care including prehospital care, initial resuscitation, intensive care, and rehabilitation. Most available literature on trauma care has focused on adults, allowing the potential to apply concepts from adult care to pediatric care. But there remain issues that will always be specific to pediatric patients that may not translate from adults. Several new devices such as intraosseous (IO) needle systems and techniques such as ultrasonography to cannulate central and peripheral veins have become available for integration into our pre-existing trauma care system for children. This review will focus specifically on the latest techniques and evidence available for establishing intravenous access, rational approaches to fluid resuscitation, and blood product transfusion in the pediatric trauma patient.
Resumo:
© 2014 Acta Materialia Inc.Commercially available implantable needle-type glucose sensors for diabetes management are robust analytically but can be unreliable clinically primarily due to tissue-sensor interactions. Here, we present the physical, drug release and bioactivity characterization of tubular, porous dexamethasone (Dex)-releasing polyurethane coatings designed to attenuate local inflammation at the tissue-sensor interface. Porous polyurethane coatings were produced by the salt-leaching/gas-foaming method. Scanning electron microscopy and micro-computed tomography (micro-CT) showed controlled porosity and coating thickness. In vitro drug release from coatings monitored over 2 weeks presented an initial fast release followed by a slower release. Total release from coatings was highly dependent on initial drug loading amount. Functional in vitro testing of glucose sensors deployed with porous coatings against glucose standards demonstrated that highly porous coatings minimally affected signal strength and response rate. Bioactivity of the released drug was determined by monitoring Dex-mediated, dose-dependent apoptosis of human peripheral blood derived monocytes in culture. Acute animal studies were used to determine the appropriate Dex payload for the implanted porous coatings. Pilot short-term animal studies showed that Dex released from porous coatings implanted in rat subcutis attenuated the initial inflammatory response to sensor implantation. These results suggest that deploying sensors with the porous, Dex-releasing coatings is a promising strategy to improve glucose sensor performance.
Resumo:
BACKGROUND: Male fertility potential cannot be measured by conventional parameters for assisted reproduction by intracytoplasmic sperm injection. This study determines the relationship between testicular and ejaculated sperm mitochondrial (mt) DNA deletions, nuclear (n) DNA fragmentation and fertilisation and pregnancy rates in ICSI. METHODS: Ejaculated sperm were obtained from 77 men and testicular sperm from 28 men with obstructive azoospermia undergoing ICSI. Testicular sperm were retrieved using a Trucut needle. MtDNA analysed using a long polymerase chain reaction. The alkaline Comet assay determined nDNA fragmentation. RESULTS: Of subjects who achieved a pregnancy (50%) using testicular sperm, only 26% had partners�??�?�¢?? sperm with wild type (WT) mtDNA. Of pregnant subjects (38%) using ejaculated sperm, only 8% had partner sperm with WT mtDNA.. In each, the successful group had less mtDNA deletions and less nDNA fragmentation. There were inverse relationships between pregnancy and mtDNA deletion numbers, size and nDNA fragmentation for both testicular and ejaculated sperm. No relationships were observed with fertilisation rates. An algorithm for the prediction of pregnancy is presented based on the quality of sperm nDNA and mtDNA. CONCLUSION: In both testicular and ejaculated sperm, mtDNA deletions and nDNA fragmentation are closely associated with pregnancy in ICSI.
Resumo:
This paper is novel andreports on the in vitro establishment of 3-D cultures of human osteoblasts. These were evaluated for protein markers of bone cells. Sequentially alkaline phosphatase, calcium incorporation for matrix mineralisation and then finally osteocalcin expression were detected in cultures. The extracellular matrix was composed of type 1 collagen and as it mineralised, needle shaped crystals were often associated with matrix vesicles initiating mineralisation. In vivo implantation in nude mice showed progression of mineralisation from the inner region outward with peripheral cells in a non-mineralised matrix. Host vessels invaded the implanted cell area. The research has relevance to musculoskeletal tissue engineering.
Resumo:
Abstract BACKGROUND: Each year 40,000 men have a vasectomy in the UK whilst another 2400 request a reversal to begin a second family. Sperm can now be obtained by testicular biopsy and subsequently used in assisted conception with intracytoplasmic sperm injection (ICSI). The study aims were to compare sperm yields of men post-vasectomy or with obstructive azoospermia (OA) of unknown aetiology with fertile men and to assess any alteration in the clinical pregnancy rates after ICSI. METHODS: Testicular tissue was obtained by Trucut needle from men who had undergone a vasectomy >5yrs previously, had OA from other causes and from fertile men during vasectomy. Seminiferous tubules were milked to measure sperm yields. Numbers of Sertoli cells, spermatids and thickness of the seminiferous tubule walls were assessed using quantitative computerized analysis. RESULTS and CONCLUSIONS: Sperm yields/g testis were significantly decreased in men post-vasectomy and in men with OA, relative to fertile men. Significant reductions were also observed in early (40%) and mature (29%) spermatid numbers and an increase of 31% was seen in the seminiferous tubule wall (basal membrane and collagen thickness) of vasectomised men compared to fertile men. Clinical pregnancy rates in couples who had had a vasectomy were also significantly reduced.
Resumo:
OBJECTIVE: To determine whether improvement in quality of semen over 4 consecutive days of electroejaculation in men with chronic spinal cord injury (SCI) was consistent with epididymal necrospermia. DESIGN: Prospective study of a random sample of men with SCI. SETTING: A southeastern Australian SCI management center in collaboration with the specialist andrology service of a university-based department of obstetrics and gynecology in a tertiary referral hospital. PATIENT(S): Nine men with chronic spinal cord injury. INTERVENTION(S): Semen samples were obtained by using electroejaculation, and testicular biopsy samples were obtained by using fine-needle tissue aspiration. MAIN OUTCOME MEASURE(S): Semen analysis was performed according to World Health Organization criteria. Testicular biopsy and electron microscopy were done by using standard techniques. RESULT(S): During up to 4 days of consecutive-day electroejaculation, sperm motility and viability in semen obtained from men with chronic SCI increased by an average of 23% on days 2 and 3. The severity of the degenerative changes and the numbers of spermatozoa affected on day 1 became less marked by day 4. The changes were not present in late spermatids obtained from testicular biopsies. CONCLUSION(S): The asthenospermia of chronic SCI is similar to epididymal necrospermia and can be improved by consecutive-day electroejaculation.
Resumo:
Liquid droplets suspended by the tip of a thin wire, a glass capillary, or a needle form high-Q optical resonators, thanks to surface tension. Under gravity equilibrium conditions, the maximum drop diameter is approximately 1.5 mm for paraffin oil (volume ∼ 0.5 μL) using, for instance, a silica fiber with 250 μm thickness. Whispering gallery modes are excited by a free-space near-infrared laser that is frequency locked to the cavity resonance. The droplet cavity serves as a miniature laboratory for sensing of chemical species and particles.
Resumo:
We describe a malignant lymphoma of the parotid gland arising in a patient with Sjögren's syndrome. Diagnosis was established on needle biopsy which showed a mixed population of lymphoid cells. Immunohistochemistry revealed B-lymphoid cells, T-lymphoid cells and histiocytes. Clonal immunoglobulin heavy chain gene rearrangement was demonstrated using the polymerase chain reaction. Within the confines of the small biopsy, the lesion qualifies for the designation T-cell-rich histiocyte-rich B-cell lymphoma. The value of molecular techniques in the diagnosis of malignant lymphoma on limited tissue samples is highlighted by this case.