991 resultados para mixture performance
Resumo:
The purpose of this study was to develop and validate analytical methods for determination of amlodipine besylate in tablets. Simple, accurate and precise liquid chromatographic and spectrophotometric methods are proposed. For the chromatographic method, the conditions were: a LiChrospher (R) 100 RP-18 Merck (R) (125 mm x 4.6 mm, 5 mu m) column; methanol/water containing 1 % of trietylamine adjusted to pH 5.0 with phosphoric acid (35:65) as mobile phase; a flow rate of 1.0 mL/min and UV detector at 238 nm. Linearity was in the range of 50.0 - 350.0 mu g/mL with a correlation coefficient (r) = 0.9999. For the spectrophotometric method, the first dilutions of samples were performed in methanol and the consecutives in ultrapure water. The quantitation was made at 364.4 nm. Linearity was determined within the range of 41.0 - 61.0 mu g/mL with a correlation coefficient (r) = 0.9996. Our results demonstrate that both methods can be used in routine analysis for quality control of tablets containing amlodipine besylate.
Resumo:
A simple and rapid method, which involves liquid-phase microextraction (LPME) followed by HPLC analysis using Chiralpak AD column and UV detection, was developed for the enantioselective determination of mefloquine in plasma samples. Several factors that influence the efficiency of three-phase LPME were investigated and optimized. Under the optimal extraction conditions, the mean recoveries were 33.2 and 35.0% for (-)-(SR-)-mefloquine and (+)-(RS)-mefloquine, respectively. The method was linear over 50-1500 ng/ml range. Within-day and between-day assay precision and accuracy were below 15% for both enantiomers at concentrations of 150, 600 and 1200 ng/ml. Furthermore, no racemization or degradation were seen with the method described. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The flavone C-glucoside, vicenin-2, in semi-purified extracts of the leaves of Lychnophora ericoides was quantified in rat plasma samples using a method based on reversed-phase high performance liquid chromatography coupled to tandem mass spectrometry. Vicenin-2 was analyzed on a LiChrospher (R) RP18 column using an isocratic mobile phase consisting of a mixture of methanol: water (30:70, v/v) plus 2.0% glacial acetic acid at a flow rate of 0.8 mL min(-1). Genistein was used as internal standard. The mass spectrometer was operated in positive ionization mode and analytes were quantified by multiple reaction monitoring at m/z 595 > 457 for vicenin-2 and m/z 271 > 153 for internal standard. Prior to the analysis, each rat plasma sample was acidified with 200 mu L of 50 mmol L(-1) acetic acid solution and extracted by solid-phase extraction using a C18 cartridge. The absolute recoveries were reproducible and the coefficients of variation values were lower than 5.2%. The method was linear over the 12.5 - 1500 ng mL(-1) concentration range and the quantification limit was 12.5 ng mL(-1). Within-day and between-day assay precision and accuracy were studied at three concentration levels (40, 400 and 800 ng mL(-1)) and were lower than 15%. The developed and validated method seems to be suitable for analysis of vicenin-2 in plasma samples obtained from rats that receive a single i.p. dose of 200 mg kg(-1) vicenin-2 extract.
Resumo:
A simple enantioselective method for the determination of praziquantel (PZQ) and trans-4-hydroxypraziquantel (4-OHPZQ) in human plasma was developed and validated by high-performance liquid chromatography/mass spectrometry. The plasma samples were prepared by liquid-liquid extraction using a mixture of methyl-tert-butylether/dichloromethane (2:1, v/v) as extraction solvent. The direct resolution of PZQ and 4-OHPZQ enantiomers was performed on a Chiralpak AD column using hexane-isopropanol (75:25, v/v) as the mobile phase. Diazepam was used as internal standard. The method described here is simple and reproducible. The quantitation limit of 1.25 ng/ml for each PZQ enantiomer and of 12.5 ng/ml for each 4-OHPZQ enantiomer permits the use of the method in studies investigating the kinetic disposition of a single dose of 1.5g racemic PZQ. Enantioselectivity in the kinetic disposition of PZQ and 4-OHPZQ was observed in the clinical study. with the demonstration of a higher proportion of the (+)-(S)-PZQ and (-)-(R)-4-OHPZQ enantiomers in plasma. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A method for the simultaneous analysis of the enantiomers of mefloquine (MQ) and its main metabolite carboxymefloquine (CMQ) in plasma is described for the first time. The assay involves two-step liquid-phase micro-extraction (LPME) and enantioselective high-performance liquid chromatography. In the first LPME step, the enantiomers of MQ were extracted from an alkalinized sample through a thin layer of di-n-hexyl ether immobilized in the pores of the hollow fiber and into 0.01 M perchloric acid as acceptor solution. In the second LPME step, the same sample was acidified to enable the extraction of CMQ using the same organic solvent and 0.05 M sodium hydroxide as acceptor phase. The analytes were resolved on a Chirobiotic T column in the polar-organic mode of elution and detected at 285 nm. The recovery rates from 1 mL of plasma were in the range 35-38%. The method presented limits of quantification of 50 ng/mL for all analytes and was linear up to 1,500 and 3,000 ng/mL for the enantiomers of MQ and CMQ, respectively. The plasmatic concentrations of (+)-(RS)-MQ were higher than those of (-)-(SR)-MQ after oral administration of the racemic drug to rats.
Resumo:
Recently, some research groups have been developing studies aiming to apply spouted beds of inert particles for production of dried herbal extracts. However, mainly due to their complex composition, several problems arise during the spouted bed drying of herbal extracts such as bed instability, product accumulation, particle agglomeration, and bed collapse. The addition of drying carriers, like colloidal silicon dioxide, to the extractive solution can minimize these unwanted effects. The aim of this work was to study the influence of the addition of colloidal silicon dioxide on enhancement of the performance of the drying of hydroalcoholic extract of Bauhinia forficata Link on a spouted bed of inert particles. The physical properties of the herbal extract and of its mixture with colloidal silicon dioxide at several concentrations (20% to 80% related to solids content) were quantified by determination of the surface tension, rheological properties, density, pH, and contact angles with the inert surfaces. Drying performance was evaluated through determination of the elutriation ratio, product recovery ratio, and product accumulation. The product was characterized through determination of the thermal degradation of bioactive compounds and product moisture content. The results indicated that the rheological properties of the extracts and their preparations, the contact angle with inert material, and the work of adhesion play important roles in the spouted bed drying of herbal extracts. Higher concentration of the drying carrier significantly improved the spouted bed drying performance.
Resumo:
(+/-)-Licarin A (1), a neolignan obtained by the oxidative coupling reaction of isoeugenol, had in this study its enantiomers resolved. A novel, quick and efficient enantiomeric resolution of 1 was directly performed by chiral high-performance liquid chromatography (HPLC-PDA) protocol (CHIRALPACK (R) AD column; 9:1 (v/v) n-hexane:2-propanol; 1.0 mL/min). This method provided a chromatogram profile with a well-resolved peak separation. After isolation of each enantiomer with ee >99.9%, they were analysed in a polarimeter. Compound 2, which showed a retention time (t(r)) of 12.13 min, was the (+)-enantiomer and compound 3 (t(r) =18.90 min) was the (-)-enantiomer. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A simple method for mercury speciation in hair samples with a fast sample preparation procedure using high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry is proposed. Prior to analysis, 50 mg of hair samples were accurately weighed into 15 mL conical tubes. Then, an extractant solution containing mercaptoethanol, L-cysteine and HCl was added to the samples following sonication for 10 min. Quantitative mercury extraction was achieved with the proposed procedure. Separation of inorganic mercury (Ino-Hg), methylmercury (Met-Hg) and ethylmercury (Et-Hg) was accomplished in less than 8 min on a C18 reverse phase column with a mobile phase containing 0.05% v/v mercaptoethanol, 0.4% m/v L-cysteine, 0.06 mol L(-1) ammonium acetate and 5% v/v methanol. The method detection limits were found to be 15 ng g(-1), 10 ng g(-1) and 38 ng g(-1), for inorganic mercury, methylmercury and ethylmercury, respectively. Sample throughput is 4 samples h(-1) (duplicate). A considerable improvement in the time of analysis was achieved when compared to other published methods. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Finally, the proposed method was successfully applied to the speciation of mercury in hair samples collected from fish-eating communities of the Brazilian Amazon.
Resumo:
Evaluation of students undertaking fieldwork education placements is a critical process in the health professions. As training programs and practice evolve, systems for assessing students need to be reviewed and updated constantly. In 1995, staff of the occupational therapy training program at the University of Queensland, Australia decided to develop a new tool for assessing student fieldwork performance. Using an action research methodology, a team developed the Student Placement Evaluation Form, a flexible and comprehensive criterion-referenced evaluation tool. The present paper examines action research as an appropriate methodology for considering real-life organisational problems in a systematic and participatory manner. The action research cycles undertaken, including preliminary information gathering, tool development, trial stages and current use of the tool, are detailed in the report. Current and future development of the tool is also described.
Resumo:
Although IL-6 has been shown to predict onset of disability in older persons and both IL-6 and CRP are associated with motality risk, these markers of inflammation have only limited associations with physical performance, except for walking measures and grip strength at baseline, and do not predict change in performance 7 years later in a high-functioning subset of older adults.
Resumo:
While the physiological adaptations that occur following endurance training in previously sedentary and recreationally active individuals are relatively well understood, the adaptations to training in already highly trained endurance athletes remain unclear. While significant improvements in endurance performance and corresponding physiological markers are evident following submaximal endurance training in sedentary and recreationally active groups, an additional increase in submaximal training (i.e. volume) in highly trained individuals does not appear to further enhance either endurance performance or associated physiological variables [e.g. peak oxygen uptake (V-dot O2peak), oxidative enzyme activity]. It seems that, for athletes who are already trained, improvements in endurance performance can be achieved only through high-intensity interval training (HIT). The limited research which has examined changes in muscle enzyme activity in highly trained athletes, following HIT, has revealed no change in oxidative or glycolytic enzyme activity, despite significant improvements in endurance performance (p < 0.05). Instead, an increase in skeletal muscle buffering capacity may be one mechanism responsible for an improvement in endurance performance. Changes in plasma volume, stroke volume, as well as muscle cation pumps, myoglobin, capillary density and fibre type characteristics have yet to be investigated in response to HIT with the highly trained athlete. Information relating to HIT programme optimisation in endurance athletes is also very sparse. Preliminary work using the velocity at which V-dot O2max is achieved (Vmax) as the interval intensity, and fractions (50 to 75%) of the time to exhaustion at Vmax (Tmax) as the interval duration has been successful in eliciting improvements in performance in long-distance runners. However, Vmax and Tmax have not been used with cyclists. Instead, HIT programme optimisation research in cyclists has revealed that repeated supramaximal sprinting may be equally effective as more traditional HIT programmes for eliciting improvements in endurance performance. Further examination of the biochemical and physiological adaptations which accompany different HIT programmes, as well as investigation into the optimal HIT programme for eliciting performance enhancements in highly trained athletes is required.
Resumo:
The study of emotions in organizational settings has attained considerable prominence in recent years, but I critical issue remains unresolved. This is the relationship between emotion and performance. in this special issue, 5 articles address this topic from a variety of viewpoints. Two are theoretical essays that deal, respectively, with emotion and creativity and the relationships between individual and team performance. Three are empirical studies that canvass the emotion-performance nexus across levels of analysis: within person, between persons, and in groups. Between them, the 5 articles present a strong case for the nexus of emotions and performance, but, more important, they provide a platform for potentially fruitful future research in this burgeoning area.
Resumo:
This paper reports on a qualitative field study conducted in Australia which examined what is occurring in formal performance appraisal interviews in relation to their objectivity and resultant outcomes. Supervisors and subordinates who had recently been involved in performance appraisals were interviewed about their experiences of the process. Perceptions of the utility of, and satisfaction with the interview process were examined. Further, the effect of the relationship between the participants on objectivity was investigated. Results indicated that formal appraisal interviews were not perceived to be of great utility, and that the relationship of the participants influenced the interview.