OBJECTIVE The Short Communication presents a clinical case in which a novel procedure--the "Individualized Scanbody Technique" (IST)--was applied, starting with an intraoral digital impression and using CAD/CAM process for fabrication of ceramic reconstructions in bone level implants. MATERIAL AND METHODS A standardized scanbody was individually modified in accordance with the created emergence profile of the provisional implant-supported restoration. Due to the specific adaptation of the scanbody, the conditioned supra-implant soft tissue complex was stabilized for the intraoral optical scan process. Then, the implant platform position and the supra-implant mucosa outline were transferred into the three-dimensional data set with a digital impression system. Within the technical workflow, the ZrO2 -implant-abutment substructure could be designed virtually with predictable margins of the supra-implant mucosa. RESULTS After finalization of the 1-piece screw-retained full ceramic implant crown, the restoration demonstrated an appealing treatment outcome with harmonious soft tissue architecture. CONCLUSIONS The IST facilitates a simple and fast approach for a supra-implant mucosal outline transfer in the digital workflow. Moreover, the IST closes the interfaces in the full digital pathway.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND AND AIM So far there is little evidence from randomised clinical trials (RCT) or systematic reviews on the preferred or best number of implants to be used for the support of a fixed prosthesis in the edentulous maxilla or mandible, and no consensus has been reached. Therefore, we reviewed articles published in the past 30 years that reported on treatment outcomes for implant-supported fixed prostheses, including survival of implants and survival of prostheses after a minimum observation period of 1 year. MATERIAL AND METHODS MEDLINE and EMBASE were searched to identify eligible studies. Short and long-term clinical studies were included with prospective and retrospective study designs to see if relevant information could be obtained on the number of implants related to the prosthetic technique. Articles reporting on implant placement combined with advanced surgical techniques such as sinus floor elevation (SFE) or extensive grafting were excluded. Two reviewers extracted the data independently. RESULTS A primary search was broken down to 222 articles. Out of these, 29 studies comprising 26 datasets fulfilled the inclusion criteria. From all studies, the number of planned and placed implants was available. With two exceptions, no RCTs were found, and these two studies did not compare different numbers of implants per prosthesis. Eight studies were retrospective; all the others were prospective. Fourteen studies calculated cumulative survival rates for 5 and more years. From these data, the average survival rate was between 90% and 100%. The analysis of the selected articles revealed a clear tendency to plan 4 to 6 implants per prosthesis. For supporting a cross-arch fixed prosthesis in the maxilla, the variation is slightly greater. CONCLUSIONS In spite of a dispersion of results, similar outcomes are reported with regard to survival and number of implants per jaw. Since the 1990s, it was proven that there is no need to install as many implants as possible in the available jawbone. The overwhelming majority of articles dealing with standard surgical procedures to rehabilitate edentulous jaws uses 4 to 6 implants.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway. MATERIALS AND METHODS This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test. RESULTS All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001). CONCLUSION Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVES The aim of this prospective cohort trial was to perform a cost/time analysis for implant-supported single-unit reconstructions in the digital workflow compared to the conventional pathway. MATERIALS AND METHODS A total of 20 patients were included for rehabilitation with 2 × 20 implant crowns in a crossover study design and treated consecutively each with customized titanium abutments plus CAD/CAM-zirconia-suprastructures (test: digital) and with standardized titanium abutments plus PFM-crowns (control conventional). Starting with prosthetic treatment, analysis was estimated for clinical and laboratory work steps including measure of costs in Swiss Francs (CHF), productivity rates and cost minimization for first-line therapy. Statistical calculations were performed with Wilcoxon signed-rank test. RESULTS Both protocols worked successfully for all test and control reconstructions. Direct treatment costs were significantly lower for the digital workflow 1815.35 CHF compared to the conventional pathway 2119.65 CHF [P = 0.0004]. For subprocess evaluation, total laboratory costs were calculated as 941.95 CHF for the test group and 1245.65 CHF for the control group, respectively [P = 0.003]. The clinical dental productivity rate amounted to 29.64 CHF/min (digital) and 24.37 CHF/min (conventional) [P = 0.002]. Overall, cost minimization analysis exhibited an 18% cost reduction within the digital process. CONCLUSION The digital workflow was more efficient than the established conventional pathway for implant-supported crowns in this investigation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Technical complications in implant prosthetic cases represent a major challenge in dentistry. This case report describes minimally invasive management to recover an implant with a fractured remnant of a zirconia abutment, including provisional rehabilitation during a sequential treatment protocol in the esthetic zone. A patient was treated with a screw-retained one-piece implant-supported reconstruction made of a customized zirconia abutment with direct ceramic veneering in the maxillary right central incisor position. During the prosthetic try-in, a fracture in the apical portion of the abutment was evident. The first rescue attempt led to fracture of the retrieval instrument. Immediately, an individualized wired construction was applied to bond the existing fractured reconstruction to the neighboring teeth to maintain the peri-implant mucosal architecture. Because the implant screw canal was blocked, a customized round bur had to be manufactured and was placed in the implant axis with a specific bracket tool from the service set to protect the interior implant threads. Then, the drills of the service set were guided by the newly created access to remove the fractured remnants. The implant screw was retapped and the area rinsed with chlorhexidine solution. All remnants were removed without the need for surgical intervention. Neither the implant connection nor the bone-to-implant interface was damaged. The stepwise treatment approach with the customized round bur combined with the system-specific drills of the service set saved the blocked implant so that the patient could be successfully rehabilitated with a new implant reconstruction.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE The aim of this cross-sectional study was to estimate bone loss of implants with platform-switching design and analyze possible risk indicators after 5 years of loading in a multi-centered private practice network. METHOD AND MATERIALS Peri-implant bone loss was measured radiographically as the distance from the implant shoulder to the mesial and distal alveolar crest, respectively. Risk factor analysis for marginal bone loss included type of implant prosthetic treatment concept and dental status of the opposite arch. RESULTS A total of 316 implants in 98 study patients after 5 years of loading were examined. The overall mean value for radiographic bone loss was 1.02 mm (SD ± 1.25 mm, 95% CI 0.90- 1.14). Correlation analyses indicated a strong association of peri-implant bone loss > 2 mm for removable implant-retained prostheses with an odds ratio of 53.8. CONCLUSION The 5-year-results of the study show clinically acceptable values of mean bone loss after 5 years of loading. Implant-supported removable prostheses seem to be a strong co-factor for extensive bone level changes compared to fixed reconstructions. However, these results have to be considered for evaluation of the included special cohort under private dental office conditions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND Little information is yet available on zirconia-based prostheses supported by implants. PURPOSE To evaluate technical problems and failures of implant-supported zirconia-based prostheses with exclusive screw-retention. MATERIAL AND METHODS Consecutive patients received screw-retained zirconia-based prostheses supported by implants and were followed over a time period of 5 years. The implant placement and prosthetic rehabilitation were performed in one clinical setting, and all patients participated in the maintenance program. The treatment comprised single crowns (SCs) and fixed dental prostheses (FDPs) of three to 12 units. Screw-retention of the CAD/CAM-fabricated SCs and FDPs was performed with direct connection at the implant level. The primary outcome was the complete failure of zirconia-based prostheses; outcome measures were fracture of the framework or extensive chipping resulting in the need for refabrication. A life table analysis was performed, the cumulative survival rate (CSR) calculated, and a Kaplan-Meier curve drawn. RESULTS Two hundred and ninety-four implants supported 156 zirconia-based prostheses in 95 patients (52 men, 43 women, average age 59.1 ± 11.7 years). Sixty-five SCs and 91 FDPs were identified, comprising a total of 441 units. Fractures of the zirconia framework and extensive chipping resulted in refabrication of nine prostheses. Nearly all the prostheses (94.2%) remained in situ during the observation period. The 5-year CSR was 90.5%, and 41 prostheses (14 SCs, 27 FDPs) comprising 113 units survived for an observation time of more than 5 years. Six SCs exhibited screw loosening, and polishing of minor chipping was required for five prostheses. CONCLUSIONS This study shows that zirconia-based implant-supported fixed prostheses exhibit satisfactory treatment outcomes and that screw-retention directly at the implant level is feasible.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The reconstruction of extended maxillary and mandibular defects with prefabricated free flaps is a two stage procedure, that allows immediate function with implant supported dentures. The appropriate delay between prefabrication and reconstruction depends on the interfacial strength of the bone–implant surface. The purpose of this animal study was to evaluate the removal torque of unloaded titanium implants in the fibula, the scapula and the iliac crest. Ninety implants with a sandblasted and acid-etched (SLA) surface were tested after healing periods of 3, 6, and 12 weeks, respectively. Removal torque values (RTV) were collected using a computerized counterclockwise torque driver. The bicortical anchored 8 mm implants in the fibula revealed values of 63.73 Ncm, 91.50 Ncm, and 101.83 Ncm at 3, 6, and 12 weeks, respectively. The monocortical anchorage in the iliac crest showed values of 71.40 Ncm, 63.14 Ncm, and 61.59 Ncm with 12 mm implants at the corresponding times. The monocortical anchorage in the scapula demonstrated mean RTV of 62.28 Ncm, 97.63 Ncm, and 99.7 Ncm with 12 mm implants at 3, 6, and 12 weeks, respectively. The study showed an increase of removal torque with increasing healing time. The interfacial strength for bicortical anchored 8 mm implants in the fibula was comparable to monocortical anchored 12 mm implants in the iliac crest and the scapula at the corresponding times. The resistance to shear seemed to be determined by the type of anchorage (monocortical vs. bicortical) and the length of the implant with greater amount of bone–implant interface.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Resection of musculoskeletal sarcoma can result in large bone defects where regeneration is needed in a quantity far beyond the normal potential of self-healing. In many cases, these defects exhibit a limited intrinsic regenerative potential due to an adjuvant therapeutic regimen, seroma, or infection. Therefore, reconstruction of these defects is still one of the most demanding procedures in orthopaedic surgery. The constraints of common treatment strategies have triggered a need for new therapeutic concepts to design and engineer unparalleled structural and functioning bone grafts. To satisfy the need for long-term repair and good clinical outcome, a paradigm shift is needed from methods to replace tissues with inert medical devices to more biological approaches that focus on the repair and reconstruction of tissue structure and function. It is within this context that the field of bone tissue engineering can offer solutions to be implemented into surgical therapy concepts after resection of bone and soft tissue sarcoma. In this paper we will discuss the implementation of tissue engineering concepts into the clinical field of orthopaedic oncology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work examined the suitability of the PAGAT gel dosimeter for use in dose distribution measurements around high-density implants. An assessment of the gels reactivity with various metals was performed and no corrosive effects were observed. An artefact reduction technique was also investigated in order to minimise scattering of the laser light in the optical CT scans. The potential for attenuation and backscatter measurements using this gel dosimeter were examined for a temporary tissue expander's internal magnetic port.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A substituição clínica de dentes naturais perdidos por implantes osteointegrados tem representado uma das primeiras opções terapêuticas para a reabilitação de pacientes total ou parcialmente edêntulos. Apesar dos excelentes índices de sucesso demonstrados pelas restaurações implanto-suportadas, alguns fatores permanecem não esclarecidos, principalmente no que diz respeito à remodelação óssea ao redor dos implantes osteointegrados. Desta forma, o objetivo deste estudo foi avaliar a relação do nível de instalação dos implantes dentários com os parâmetros clínicos, com a remodelação óssea peri-implantar e com a colonização bacteriana, em implantes de plataforma regular, submetidos à carga imediata. Implantes de plataforma regular foram instalados em dois diferentes níveis em relação à crista óssea ao nível ósseo e supra ósseo (1 mm). No total, trinta e cinco implantes em 9 pacientes (idade média de 62,4 11,2 anos) foram avaliados radiograficamente no momento da instalação dos implantes (T1) e 6 meses após (T2), momento no qual também foram feitas análises clínicas e coleta de amostras para o teste microbiológico. Nos exames radiográficos foram analisadas a perda óssea, a partir de mensurações lineares da distância entre um ponto fixo do componente protético e o ponto mais coronário do contato osso-implante, e a densidade óptica alveolar obtida a partir de regiões ósseas de interesse (ROIs). As análises clínicas consistiram na avaliação da profundidade de sondagem e na mensuração do volume do fluido gengival peri-implantar. O perfil bacteriano dos sítios avaliados foi caracterizado por meio do método de análise de checkerboard DNA-DNA hybridization. Os testes estatísticos realizados mostraram não haver relação entre o nível de instalação dos implantes em relação à crista óssea e a remodelação óssea alveolar, tanto com relação à perda óssea (p = 0,725), como com relação à densidade óptica alveolar (p = 0,975). Também não foi possível estabelecer uma correlação entre a remodelação óssea e parâmetros clínicos como profundidade de sondagem e volume do fluido gengival peri-implantar. Com relação ao perfil bacteriano, não foram encontradas diferenças estatisticamente significativas entre os grupos avaliados para nenhuma das 40 bactérias analisadas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectifs: Observer l’évolution de la stomatite prothétique dans le temps quant à la fréquence et la sévérité ainsi que son association avec de potentiels facteurs de risque au cours d’un suivi longitudinal de 2 ans. Matériels et méthodes : Cent trente-cinq patients âgés complètement édentés et en bonne santé ont été sélectionnés pour participer à cette étude et ont été divisés de façon randomisée en deux groupes. Ils ont tous reçu une prothèse dentaire amovible totale conventionnelle au maxillaire supérieur. La moitié d’entre eux a reçu une prothèse totale mandibulaire implanto-portée retenue par deux attachements boule et l’autre moitié une prothèse conventionnelle. Ils ont été suivis sur une période de deux ans. Les données sociodémographiques, d’habitudes de vie, d’hygiène et de satisfaction des prothèses ont été amassées à l’aide de questionnaires. Les patients ont aussi subi un examen oral complet lors duquel une évaluation de la stomatite prothétique, basée sur la classification de Newton, a été effectuée ainsi qu’un prélèvement de la plaque prothétique. Les analyses microbiologiques pertinentes afin de détecter la présence de Candida ont ensuite été effectuées. Des tests Chi-carré de Pearson et McNemar ont été utilisés pour analyser la fréquence de la stomatite, son association avec de possibles facteurs de risque ainsi que son évolution dans le temps. Des rapports de cotes (odds ratio) et leurs intervalles de confiance (95%) ont été effectués afin de déterminer la force d’association entre les facteurs de risque et la stomatite prothétique. Résultats : La prévalence de la stomatite a augmenté entre la première (63,6%) et la deuxième année de suivi (88,7%) avec une incidence de 78,8%. Les patients souffrant d’une stomatite de type 2 ou 3 et qui brossent leur palais ont environ 6 fois plus de chance de voir la sévérité de leur stomatite diminuer [p = 0,04 OR 5,88 CI (1,1-32,2)]. Il n’y a pas d’association statistiquement significative entre la fréquence de la stomatite et les facteurs de risque investigués. La prévalence de la candidose est demeurée stable dans le temps (45,8% et 49,2% à la première et deuxième année de suivi respectivement, p > 0,05). Il n’y a pas d’association entre la présence d’une candidose orale, la stomatite prothétique et les facteurs de risque étudiés. Conclusion : Les résultats de cette étude suggèrent que la stomatite prothétique progresse dans le temps indépendamment de la présence d’une candidose. Le brossage du palais pourrait être une approche simple à conseiller aux patients souffrant d’une stomatite prothétique de type 2 ou 3.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Problématique : Les connaissances théoriques et pratiques au sujet de la mise en charge immédiate d’implants non jumelés chez les édentés sont limitées. Objectifs : Cette étude avait pour but de : (1) déterminer le taux de survie implantaire de 2 implants non jumelés supportant une prothèse totale mandibulaire suite à une mise en charge immédiate, (2) évaluer les changements des niveaux osseux et de stabilité implantaire survenus sur ces 2 implants durant une période de 4 mois et les comparer à un implant témoin, et (3) décrire les complications cliniques associées à ce mode de mise en charge. Méthodologie : Chez 18 individus édentés (âge moyen de 62±7 ans), cette étude de phase I avec un design pré/post a évalué les résultats cliniques suivant la mise en charge immédiate (<48 heures) de 2 implants non jumelés par une prothèse totale mandibulaire. À l’aide de radiographies périapicales, de sondages osseux et d’analyses de la fréquence en résonnance, les niveaux osseux péri-implantaires (en mm) et les niveaux de stabilité implantairte (en ISQ) de ces 2 implants insérés dans la région parasymphysaire ont été évalués à la chirurgie (T0) et au suivi de 4 mois (T1). Un implant non submergé et sans mise en charge inséré dans la région de la symphyse mandibulaire a été utilisé comme témoin. Les données ont été analysées avec des modèles mixtes linéaires, la méthode de Tukey ajustée, l’analyse de variance de Friedman et des tests de rang signés de Wilcoxon. Résultats : De T0 à T1, 3 implants mis en charge immédiatement ont échoué chez 2 patients. Le taux de survie implantaire obtenu était donc de 91,7% (33/36) et, par patient, de 88,9% (16/18). Aucun implant témoin n’a échoué. Les changements osseux documentés radiologiquement et par sondage autour des implants mis en charge immédiatement étaient, respectivement, de -0,2 ± 0,3 mm et de -0,5 ± 0,6 mm. Les pertes d’os de support implantaire n’ont pas été démontrées statistiquement différentes entre les implants avec mise en charge immédiate et les témoins. Les niveaux moyens de stabilité implantaire ont augmenté de 5 ISQ indépendamment de la mise en charge. Les niveaux moyens d’ISQ n’ont pas été démontrés statistiquement différents entre les implants avec mise en charge immédiate et les témoins à T0 ou T1. Cinq des 18 patients n’ont expérimenté aucune complication clinique, alors que 9 en ont eu au moins deux. Hormis les échecs implantaires, aucune de ces complications n’a entraîné de changements au protocole. Conclusion : Les résultats à court terme suggèrent que : (1) le taux de survie implantaire suite au protocole immédiat est similaire à ceux rapportés lors d’un protocole de mise en charge conventionnel (2) les changements d’os de support implantaire et de stabilité ne sont pas différents comparativement à ceux d’un implant témoin, (3) un niveau élevé d’expérience clinique et chirurgicale est requis pour effectuer les procédures et pour gérer les complications associées. Ces résultats préliminaires devraient être confirmés dans une étude clinique de phase II.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The literature has shown a relation between periodontics and the removable partial denture (RPD), with progressive destruction observed in the support structures. The aim of this study was to clinically assess periodontal condition in users of removal partial denture (RPD), and compare right abutments teeth, indirect abutments and controls before installation and after 1 year, in addition to comparing tooth-supported and tooth mucosa-supported abutments. A total of 50 patients, 32 women and 18 men, mean age of 45 years, took part in the study. The patients were examined by a single examiner at prosthesis installation and after 3, 6, 9 and 12 months. The following were verified at each examination: Probe Depth (PD), Plaque Index (PI), Gingival Index (GI), the amount of Keratinized Mucosa (KM), Gingival Recession (GR) and Dental Mobility (DM); in addition patients received oral hygiene orientation, accompanied by prophylaxis, periodontal scaling and root planing (PSRP), when necessary. Analysis of Variance (ANOVA) with Tukey-Kramer post test was used to assess the dependent variables (PD, PI, KM, GR) of the three groups over time while Friedman s test was used for GI. To assess the outcomes of prosthesis type in the right abutment group, a confidence interval-based analysis was performed. The results showed that the control group was the least compromised in all the variables studied. With respect to development of the groups over time, it was verified that the measures for GR, PD, GI and KM increased from initial examination to 1 year of use in all the groups, but only PI showed a significant increase. There was a non-discriminatory low prevalence of dental mobility. The tooth mucosa-supported prosthesis had significantly higher values for GR, GI and PI and significantly lower ones for KM when compared to tooth-supported. Over time, both types of prostheses showed no significant differences from initial to final examination for the variables GR, PD, KM and GI, with PI significant only for tooth-supported. The results showed that the teeth most involved in RPD design had greater potential of periodontal damage, probably because of greater dental biofilm accumulation. Abutments elements adjacent to the free extremities had less favorable periodontal condition than those adjacent to interpolated spaces, but the use of RPD did not worsen the initial condition