933 resultados para immediate implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many models of immediate memory predict the presence or absence of various effects, but none have been tested to see whether they predict an appropriate distribution of effect sizes. The authors show that the feature model (J. S. Nairne, 1990) produces appropriate distributions of effect sizes for both the phonological confusion effect and the word-length effect. The model produces the appropriate number of reversals, when participants are more accurate with similar items or long items, and also correctly predicts that participants performing less well overall demonstrate smaller and less reliable phonological similarity and word-length effects and are more likely to show reversals. These patterns appear within the model without the need to assume a change in encoding or rehearsal strategy or the deployment of a different storage buffer. The implications of these results and the wider applicability of the distributionmodeling approach are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In immediate recall tasks, visual recency is substantially enhanced when output interference is low (Cowan, Saults, Elliott, & Moreno, 2002; Craik, 1969) whereas auditory recency remains high even under conditions of high output interference. Ibis auditory advantage has been interpreted in terms of auditory resistance to output interference (e.g., Neath & Surprenant, 2003). In this study the auditory-visual difference at low output interference re-emerged when ceiling effects were accounted for, but only with spoken output. With written responding the auditory advantage remained significantly larger with high than with low output interference. These new data suggest that both superior auditory encoding and modality-specific output interference contribute to the classic auditory-visual modality effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study examined people's interpretation of European Commission (EC) recommended verbal descriptors for risk of medicine side effects, and actions to take if they do occur. Members of the general public were presented with a fictitious (but realistic) scenario about suffering from a stiff neck, visiting the local pharmacy and purchasing an over the counter (OTC) medicine (Ibruprofen). The medicine came with an information leaflet which included information about the medicine's side effects, their risk of occurrence, and recommended actions to take if adverse effects are experienced. Probability of occurrence was presented numerically (6%) or verbally, using the recommended EC descriptor (common). Results showed that, in line with findings of our earlier work with prescribed medicines, participants significantly overestimated side effect risk. Furthermore, the differences in interpretation were reflected in their judgements of satisfaction, side effect severity, risk to health, and intention to take the medicine. Finally, we observed no significant difference between people's interpretation of the recommended action descriptors ('immediately' and 'as soon as possible'). (C) 2003 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Is the human body a suitable place for a microchip? Such discussion is no longer hypothetical - in fact in reality it has not been so for some years. Restorative devices such as pacemakers and cochlear implants have become well established, yet these sophisticated devices form notably intimate links between technology and the body. More recent developments in engineering technologies have meant that the integration of silicon with biology is now reaching new levels - with devices which interact directly with the brain. As medical technologies continue to advance, their potential benefits for human enhancement will become increasingly attractive, and so we need to seriously consider where this may take us. In this paper, an attempt is made to demonstrate that, in the medical context, the foundations of more advanced implantable enhancement technologies are already notably progressed, and that they are becoming more science fact than is widely considered. A number of wider moral, ethical and legal issues stem from enhancement applications and it is difficult to foresee the social consequences, the fundamental changes on our very conception of self and the impact on our identity of adoption long term. As a result, it is necessary to acknowledge the possibilities and is timely to have debate to address the wider implications these possibilities may bring.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is now possible to directly link the human nervous system to a computer and thence onto the Internet. From an electronic and mental viewpoint this means that the Internet becomes an extension of the human nervous system (and vice versa). Such a connection on a regular or mass basis will have far reaching effects for society. In this article the authors discuss their own practical implant self-experimentation, especially insofar as it relates to extending the human nervous system. Trials involving an intercontinental link up are described. As well as technical aspects of the work, social, moral and ethical issues, as perceived by the authors, are weighed against potential technical gains. The authors also look at technical limitations inherent in the co-evolution of Internet implanted individuals as well as the future distribution of intelligence between human and machine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Endothelin-1 stimulates Gq protein-coupled receptors to promote proliferation in dividing cells or hypertrophy in terminally differentiated cardiomyocytes. In cardiomyocytes, endothelin-1 rapidly (within minutes) stimulates protein kinase signaling, including extracellular-signal regulated kinases 1/2 (ERK1/2; though not ERK5), with phenotypic/physiological changes developing from approximately 12 h. Hypertrophy is associated with changes in mRNA/protein expression, presumably consequent to protein kinase signaling, but the connections between early, transient signaling events and developed hypertrophy are unknown. Results: Using microarrays, we defined the early transcriptional responses of neonatal rat cardiomyocytes to endothelin-1 over 4 h, differentiating between immediate early gene (IEG) and second phase RNAs with cycloheximide. IEGs exhibited differential temporal and transient regulation, with expression of second phase RNAs within 1 h. Of transcripts upregulated at 30 minutes encoding established proteins, 28 were inhibited >50% by U0126 (which inhibits ERK1/2/5 signaling), with 9 inhibited 25-50%. Expression of only four transcripts was not inhibited. At 1 h, most RNAs (approximately 67%) were equally changed in total and polysomal RNA with approximately 17% of transcripts increased to a greater extent in polysomes. Thus, changes in expression of most protein-coding RNAs should be reflected in protein synthesis. However, approximately 16% of transcripts were essentially excluded from the polysomes, including some protein-coding mRNAs, presumably inefficiently translated. Conclusion: The phasic, temporal regulation of early transcriptional responses induced by endothelin-1 in cardiomyocytes indicates that, even in terminally differentiated cells, signals are propagated beyond the primary signaling pathways through transcriptional networks leading to phenotypic changes (that is, hypertrophy). Furthermore, ERK1/2 signaling plays a major role in this response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores a novel tactile human-machine interface based on the controlled stimulation of mechanoreceptors by a subdermal magnetic implant manipulated through an external electromagnet. The selection of a suitable implant magnet and implant site is discussed and an external interface for manipulating the implant is described. The paper also reports on the basic properties of such an interface, including magnetic field strength sensitivity and frequency sensitivity obtained through experimentation on two participants. Finally, the paper presents two practical application scenarios for the interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In his forum paper, Prof. Kevin Warwick considers four different examples of how the use of implant technology is opening up the possibility of upgrading human abilities, particularly in terms of mental cognition. The main thrust is an overview of Prof. Warwick's own research, which led to him receiving a neural implant linking his nervous system bi-directionally with the internet. With this implant in place, neural signals were transmitted to various technological devices to directly control them, in some cases via the internet, and feedback to the brain was obtained from such stimuli as the fingertips of a robot hand, ultrasonic (extra-) sensory input and neural signals directly from another human's nervous system. A view is taken as to the prospects for the future, both in the short-term as a therapeutic device and in the long-term as a form of enhancement, including the realistic potential, in the near future, for thought communication – thereby opening up tremendous commercial potential. The therapy/enhancement dichotomy is considered here, as well as military and medical issues. Clearly though, an individual whose brain is part human/part machine can have abilities that far surpass those who remain with a human brain alone. Will such an individual exhibit different moral and ethical values to those of a human? If so, what effects might this have on society?