909 resultados para hemodynamic measurements
Resumo:
The toxicity of heavy metals in natural waters is strongly dependent on the local chemical environment. Assessing the bioavailability of radionuclides predicts the toxic effects to aquatic biota. The technique of diffusive gradients in thin films (DGT) is largely exploited for bioavailability measurements of trace metals in waters. However, it has not been applied for plutonium speciation measurements yet. This study investigates the use of DGT technique for plutonium bioavailability measurements in chemically different environments. We used a diffusion cell to determine the diffusion coefficients (D) of plutonium in polyacrylamide (PAM) gel and found D in the range of 2.06-2.29 × 10(-6) cm(2) s(-1). It ranged between 1.10 and 2.03 × 10(-6) cm(2) s(-1) in the presence of fulvic acid and in natural waters with low DOM. In the presence of 20 ppm of humic acid of an organic-rich soil, plutonium diffusion was hindered by a factor of 5, with a diffusion coefficient of 0.50 × 10(-6) cm(2) s(-1). We also tested commercially available DGT devices with Chelex resin for plutonium bioavailability measurements in laboratory conditions and the diffusion coefficients agreed with those from the diffusion cell experiments. These findings show that the DGT methodology can be used to investigate the bioaccumulation of the labile plutonium fraction in aquatic biota.
Resumo:
High-altitude pulmonary edema (HAPE) is a life-threatening condition occurring in predisposed subjects at altitudes above 2,500 m. It is not clear whether, in addition to hemodynamic factors and defective alveolar fluid clearance, inflammation plays a pathogenic role in HAPE. We therefore made serial measurements of exhaled pulmonary nitric oxide (NO), a marker of airway inflammation, in 28 HAPE-prone and 24 control subjects during high-altitude exposure (4,559 m). To examine the relationship between pulmonary NO synthesis and pulmonary vascular tone, we also measured systolic pulmonary artery pressure (Ppa). In the 13 subjects who developed HAPE, exhaled NO did not show any tendency to increase during the development of lung edema. Throughout the entire sojourn at high altitude, pulmonary exhaled NO was roughly 30% lower in HAPE-prone than in control subjects, and there existed an inverse relationship between Ppa and exhaled NO (r = -0.51, p < 0.001). These findings suggest that HAPE is not preceded by airway inflammation. Reduced exhaled NO may be related to altered pulmonary NO synthesis and/or transport and clearance, and the data in our study could be consistent with the novel concept that in HAPE-prone subjects, a defect in pulmonary epithelial NO synthesis may contribute to exaggerated hypoxic pulmonary vasoconstriction and in turn to pulmonary edema.
Resumo:
BACKGROUND AND PURPOSE: Carotid artery stenting (CAS) is associated with a higher risk of both hemodynamic depression and new ischemic brain lesions on diffusion-weighted imaging than carotid endarterectomy (CEA). We assessed whether the occurrence of hemodynamic depression is associated with these lesions in patients with symptomatic carotid stenosis treated by CAS or CEA in the randomized International Carotid Stenting Study (ICSS)-MRI substudy. METHODS: The number and total volume of new ischemic lesions on diffusion-weighted imaging 1 to 3 days after CAS or CEA was measured in the ICSS-MRI substudy. Hemodynamic depression was defined as periprocedural bradycardia, asystole, or hypotension requiring treatment. The number of new ischemic lesions was the primary outcome measure. We calculated risk ratios and 95% confidence intervals per treatment with Poisson regression comparing the number of lesions in patients with or without hemodynamic depression. RESULTS: A total of 229 patients were included (122 allocated CAS; 107 CEA). After CAS, patients with hemodynamic depression had a mean of 13 new diffusion-weighted imaging lesions, compared with a mean of 4 in those without hemodynamic depression (risk ratio, 3.36; 95% confidence interval, 1.73-6.50). The number of lesions after CEA was too small for reliable analysis. Lesion volumes did not differ between patients with or without hemodynamic depression. CONCLUSIONS: In patients treated by CAS, periprocedural hemodynamic depression is associated with an excess of new ischemic lesions on diffusion-weighted imaging. The findings support the hypothesis that hypoperfusion increases the susceptibility of the brain to embolism. CLINICAL TRIAL REGISTRATION URL: http://www.controlled-trials.com. Unique identifier: ISRCTN25337470.
Resumo:
Purine nucleotide pyrophosphotransferase was purified to apparent homogeneity from a culture filtrate of Streptomyces morookaensis. It is a monomeric protein with a molecular weight of 24 000-25 000, and its isoelectric point is 6.9. The enzyme synthesizes purine nucleoside 5'-phosphate (mono, di, or tri) 3'-diphosphates such as pppApp, ppApp, pApp, pppGpp, ppGpp and pppIpp by transferring a pyrophosphoryl group from the 5'-position of ATP, dATP and ppApp to the 3'-position of purine nucleotides. The purified enzyme catalysed the formation of 435 mumol of pppApp and 620 mumol of pppGpp from ATP and GTP per min mg protein under the standard conditions. The enzyme requires absolutely a divalent cation for activity, and optimum pH for the enzyme activity lay above 10 for Mg2+, for Co2+ and Zn2+ from 9 to 9.5, and for Fe2+ from 7.5 to 8. The following Michaelis constants were determined: AMP, 2.78 mM; ADP, 3.23 mM; GMP, 0.89 mM; GDP, 0.46 mM and GTP, 1.54 mM, in the case of ATP donor. The enzyme is inhibited by guanine, guanosine, dGDP, dGTP, N-bromosuccinimide, iodacetate, sodium borate and mercuric acetate.
Resumo:
BACKGROUND & AIMS: The study was designed to investigate and quantify nutritional support, and particularly enteral nutrition (EN), in critically ill patients with severe hemodynamic failure. METHODS: Prospective, descriptive study in a surgical intensive care unit (ICU) in a university teaching hospital: patients aged 67+/-13 yrs (mean+/-SD) admitted after cardiac surgery with extracorporeal circulation, staying 5 days in the ICU with acute cardiovascular failure. Severity of disease was assessed with SAPS II, and SOFA scores. Variables were energy delivery and balance, nutrition route, vasopressor doses, and infectious complications. Artificial feeding delivered according to ICU protocol. EN was considered from day 2-3. Energy target was set 25 kcal/kg/day to be reached stepwise over 5 days. RESULTS: Seventy out of 1114 consecutive patients were studied, aged 67+/-17 years, and staying 10+/-7 days in the ICU. Median SAPS II was 43. Nine patients died (13%). All patients had circulatory failure: 18 patients required intra-aortic balloon-pump support (IABP). Norepinephrine was required in 58 patients (83%). Forty patients required artificial nutrition. Energy delivery was very variable. There was no abdominal complication related to EN. As a mean, 1360+/-620 kcal/kg/day could be delivered enterally during the first 2 weeks, corresponding to 70+/-35% of energy target. Enteral nutrient delivery was negatively influenced by increasing dopamine and norepinephrine doses, but not by the use of IABP. CONCLUSION: EN is possible in the majority of patients with severe hemodynamic failure, but usually results in hypocaloric feeding. EN should be considered in patients with careful abdominal and energy monitoring.
Resumo:
To assess the role of vasopressin (AVP) in congestive heart failure (CHF), we investigated 10 patients with CHF refractory to conventional treatment, before and 60 minutes after intravenous administration of 5 micrograms/kg of d(CH2)5Tyr(Me)AVP, a specific antagonist of AVP at the vascular receptor level. Heart rate, systemic arterial pressure, pulmonary arterial pressure, pulmonary capillary wedge pressure, cardiac index by thermodilution, and cutaneous blood flow by laser-Doppler technique were measured. In 9 patients there was no significant hemodynamic and cutaneous blood flow response to the AVP antagonist. Plasma AVP was 2.3 +/- 0.8 pg/ml and plasma osmolality 284 +/- 14 mosm/kg H2O. The tenth patient had the most severe CHF. His plasma AVP was 55 pg/ml and plasma osmolality 290 mosm/kg. He responded to the AVP antagonist with a marked decrease in systemic arterial pressure from 115/61 to 79/41 mm Hg, in pulmonary arterial pressure from 58/31 to 33/13 mm Hg and in pulmonary capillary wedge pressure from 28 to 15 mm Hg. Simultaneously cardiac index increased from 1.1 to 2.21 X min-1 X m-2 and cutaneous blood flow rose 5-fold. Thus, most patients with CHF have only moderately elevated plasma AVP and its role in determining peripheral vascular resistance appears to be limited. AVP may become important in rare patients presenting with marked hemodynamic instability and very high plasma AVP.
Resumo:
Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.
Resumo:
OBJECTIVE: The purpose of this study was to compare the use of different variables to measure the clinical wear of two denture tooth materials in two analysis centers. METHODS: Twelve edentulous patients were provided with full dentures. Two different denture tooth materials (experimental material and control) were placed randomly in accordance with the split-mouth design. For wear measurements, impressions were made after an adjustment phase of 1-2 weeks and after 6, 12, 18, and 24 months. The occlusal wear of the posterior denture teeth of 11 subjects was assessed in two study centers by use of plaster replicas and 3D laser-scanning methods. In both centers sequential scans of the occlusal surfaces were digitized and superimposed. Wear was described by use of four different variables. Statistical analysis was performed after log-transformation of the wear data by use of the Pearson and Lin correlation and by use of a mixed linear model. RESULTS: Mean occlusal vertical wear of the denture teeth after 24 months was between 120μm and 212μm, depending on wear variable and material. For three of the four variables, wear of the experimental material was statistically significantly less than that of the control. Comparison of the two study centers, however, revealed correlation of the wear variables was only moderate whereas strong correlation was observed among the different wear variables evaluated by each center. SIGNIFICANCE: Moderate correlation was observed for clinical wear measurements by optical 3D laser scanning in two different study centers. For the two denture tooth materials, wear measurements limited to the attrition zones led to the same qualitative assessment.
Resumo:
In extreme situations, such as hyperacute rejection of heart transplant or major heart trauma, heart preservation may not be possible. Our experimental team works on a project of peripheral extracorporeal membrane oxygenation (ECMO) support in acardia as a bridge to heart transplantation or artificial heart implantation. An ECMO support was established in five calves (58.6 ± 6.9 kg) by the transjugular insertion to the caval axis of a self-expanded cannula, with carotid artery return. After baseline measurements, ventricular fibrillation was induced, great arteries were clamped, heart was excised, and right and left atria remnants, containing pulmonary veins, were sutured together leaving an atrial septal defect over the caval axis cannula. Measurements of pump flow and arterial pressure were taken with the pulmonary artery clamped and anastomosed with the caval axis for a total of 6 hours. Pulmonary artery anastomosis to the caval axis provided an acceptable 6 hour hemodynamic stability, permitting a peripheral access ECMO support in extreme scenarios indicating a heart explantation.
Resumo:
The study of wave propagation at sonic frequency in soil leads to elasticity parameter determination. These parameters are compatible to those measured simultaneously by static loading. The acquisition of in situ elasticity parameter combined with laboratory description of the elastoplastic behaviour can lead to in situ elastoplastic curves. - L'étude de la propagation des ondes acoustiques permet la détermination des paramètres d'élasticité dans les sols. Ces paramètres sont cohérents avec des mesures statiques simultanées. L'acquisition des paramètres d'élasticité in situ associée à une description du comportement élasto-plastique mesuré en laboratoire permet d'obtenir des courbes d'élastoplasticité in situ.
Resumo:
OBJECTIVE: Prospective studies have shown that quantitative ultrasound (QUS) techniques predict the risk of fracture of the proximal femur with similar standardised risk ratios to dual-energy x-ray absorptiometry (DXA). Few studies have investigated these devices for the prediction of vertebral fractures. The Basel Osteoporosis Study (BOS) is a population-based prospective study to assess the performance of QUS devices and DXA in predicting incident vertebral fractures. METHODS: 432 women aged 60-80 years were followed-up for 3 years. Incident vertebral fractures were assessed radiologically. Bone measurements using DXA (spine and hip) and QUS measurements (calcaneus and proximal phalanges) were performed. Measurements were assessed for their value in predicting incident vertebral fractures using logistic regression. RESULTS: QUS measurements at the calcaneus and DXA measurements discriminated between women with and without incident vertebral fracture, (20% height reduction). The relative risks (RRs) for vertebral fracture, adjusted for age, were 2.3 for the Stiffness Index (SI) and 2.8 for the Quantitative Ultrasound Index (QUI) at the calcaneus and 2.0 for bone mineral density at the lumbar spine. The predictive value (AUC (95% CI)) of QUS measurements at the calcaneus remained highly significant (0.70 for SI, 0.72 for the QUI, and 0.67 for DXA at the lumbar spine) even after adjustment for other confounding variables. CONCLUSIONS: QUS of the calcaneus and bone mineral density measurements were shown to be significant predictors of incident vertebral fracture. The RRs for QUS measurements at the calcaneus are of similar magnitude as for DXA measurements.