939 resultados para goldfish, colour-blind, motion detection, trainingsexperiments, random dot pattern


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this paper is to introduce a fourth-order cost function of the displaced frame difference (DFD) capable of estimatingmotion even for small regions or blocks. Using higher than second-orderstatistics is appropriate in case the image sequence is severely corruptedby additive Gaussian noise. Some results are presented and compared to those obtained from the mean kurtosis and the mean square error of the DFD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molecular docking softwares are one of the important tools of modern drug development pipelines. The promising achievements of the last 10 years emphasize the need for further improvement, as reflected by several recent publications (Leach et al., J Med Chem 2006, 49, 5851; Warren et al., J Med Chem 2006, 49, 5912). Our initial approach, EADock, showed a good performance in reproducing the experimental binding modes for a set of 37 different ligand-protein complexes (Grosdidier et al., Proteins 2007, 67, 1010). This article presents recent improvements regarding the scoring and sampling aspects over the initial implementation, as well as a new seeding procedure based on the detection of cavities, opening the door to blind docking with EADock. These enhancements were validated on 260 complexes taken from the high quality Ligand Protein Database [LPDB, (Roche et al., J Med Chem 2001, 44, 3592)]. Two issues were identified: first, the quality of the initial structures cannot be assumed and a manual inspection and/or a search in the literature are likely to be required to achieve the best performance. Second the description of interactions involving metal ions still has to be improved. Nonetheless, a remarkable success rate of 65% was achieved for a large scale blind docking assay, when considering only the top ranked binding mode and a success threshold of 2 A RMSD to the crystal structure. When looking at the five-top ranked binding modes, the success rate increases up to 76%. In a standard local docking assay, success rates of 75 and 83% were obtained, considering only the top ranked binding mode, or the five top binding modes, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: The current standard for diagnosing prostate cancer in men at risk relies on a transrectal ultrasound-guided biopsy test that is blind to the location of the cancer. To increase the accuracy of this diagnostic pathway, a software-based magnetic resonance imaging-ultrasound (MRI-US) fusion targeted biopsy approach has been proposed. OBJECTIVE: Our main objective was to compare the detection rate of clinically significant prostate cancer with software-based MRI-US fusion targeted biopsy against standard biopsy. The two strategies were also compared in terms of detection of all cancers, sampling utility and efficiency, and rate of serious adverse events. The outcomes of different targeted approaches were also compared. EVIDENCE ACQUISITION: We performed a systematic review of PubMed/Medline, Embase (via Ovid), and Cochrane Review databases in December 2013 following the Preferred Reported Items for Systematic reviews and Meta-analysis statement. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. EVIDENCE SYNTHESIS: Fourteen papers reporting the outcomes of 15 studies (n=2293; range: 13-582) were included. We found that MRI-US fusion targeted biopsies detect more clinically significant cancers (median: 33.3% vs 23.6%; range: 13.2-50% vs 4.8-52%) using fewer cores (median: 9.2 vs 37.1) compared with standard biopsy techniques, respectively. Some studies showed a lower detection rate of all cancer (median: 50.5% vs 43.4%; range: 23.7-82.1% vs 14.3-59%). MRI-US fusion targeted biopsy was able to detect some clinically significant cancers that would have been missed by using only standard biopsy (median: 9.1%; range: 5-16.2%). It was not possible to determine which of the two biopsy approaches led most to serious adverse events because standard and targeted biopsies were performed in the same session. Software-based MRI-US fusion targeted biopsy detected more clinically significant disease than visual targeted biopsy in the only study reporting on this outcome (20.3% vs 15.1%). CONCLUSIONS: Software-based MRI-US fusion targeted biopsy seems to detect more clinically significant cancers deploying fewer cores than standard biopsy. Because there was significant study heterogeneity in patient inclusion, definition of significant cancer, and the protocol used to conduct the standard biopsy, these findings need to be confirmed by further large multicentre validating studies. PATIENT SUMMARY: We compared the ability of standard biopsy to diagnose prostate cancer against a novel approach using software to overlay the images from magnetic resonance imaging and ultrasound to guide biopsies towards the suspicious areas of the prostate. We found consistent findings showing the superiority of this novel targeted approach, although further high-quality evidence is needed to change current practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L'imagerie par résonance magnétique (IRM) peut fournir aux cardiologues des informations diagnostiques importantes sur l'état de la maladie de l'artère coronarienne dans les patients. Le défi majeur pour l'IRM cardiaque est de gérer toutes les sources de mouvement qui peuvent affecter la qualité des images en réduisant l'information diagnostique. Cette thèse a donc comme but de développer des nouvelles techniques d'acquisitions des images IRM, en changeant les techniques de compensation du mouvement, pour en augmenter l'efficacité, la flexibilité, la robustesse et pour obtenir plus d'information sur le tissu et plus d'information temporelle. Les techniques proposées favorisent donc l'avancement de l'imagerie des coronaires dans une direction plus maniable et multi-usage qui peut facilement être transférée dans l'environnement clinique. La première partie de la thèse s'est concentrée sur l'étude du mouvement des artères coronariennes sur des patients en utilisant la techniques d'imagerie standard (rayons x), pour mesurer la précision avec laquelle les artères coronariennes retournent dans la même position battement après battement (repositionnement des coronaires). Nous avons découvert qu'il y a des intervalles dans le cycle cardiaque, tôt dans la systole et à moitié de la diastole, où le repositionnement des coronaires est au minimum. En réponse nous avons développé une nouvelle séquence d'acquisition (T2-post) capable d'acquérir les données aussi tôt dans la systole. Cette séquence a été testée sur des volontaires sains et on a pu constater que la qualité de visualisation des artère coronariennes est égale à celle obtenue avec les techniques standard. De plus, le rapport signal sur bruit fourni par la séquence d'acquisition proposée est supérieur à celui obtenu avec les techniques d'imagerie standard. La deuxième partie de la thèse a exploré un paradigme d'acquisition des images cardiaques complètement nouveau pour l'imagerie du coeur entier. La technique proposée dans ce travail acquiert les données sans arrêt (free-running) au lieu d'être synchronisée avec le mouvement cardiaque. De cette façon, l'efficacité de la séquence d'acquisition est augmentée de manière significative et les images produites représentent le coeur entier dans toutes les phases cardiaques (quatre dimensions, 4D). Par ailleurs, l'auto-navigation de la respiration permet d'effectuer cette acquisition en respiration libre. Cette technologie rend possible de visualiser et évaluer l'anatomie du coeur et de ses vaisseaux ainsi que la fonction cardiaque en quatre dimensions et avec une très haute résolution spatiale et temporelle, sans la nécessité d'injecter un moyen de contraste. Le pas essentiel qui a permis le développement de cette technique est l'utilisation d'une trajectoire d'acquisition radiale 3D basée sur l'angle d'or. Avec cette trajectoire, il est possible d'acquérir continûment les données d'espace k, puis de réordonner les données et choisir les paramètres temporel des images 4D a posteriori. L'acquisition 4D a été aussi couplée avec un algorithme de reconstructions itératif (compressed sensing) qui permet d'augmenter la résolution temporelle tout en augmentant la qualité des images. Grâce aux images 4D, il est possible maintenant de visualiser les artères coronariennes entières dans chaque phase du cycle cardiaque et, avec les mêmes données, de visualiser et mesurer la fonction cardiaque. La qualité des artères coronariennes dans les images 4D est la même que dans les images obtenues avec une acquisition 3D standard, acquise en diastole Par ailleurs, les valeurs de fonction cardiaque mesurées au moyen des images 4D concorde avec les valeurs obtenues avec les images 2D standard. Finalement, dans la dernière partie de la thèse une technique d'acquisition a temps d'écho ultra-court (UTE) a été développée pour la visualisation in vivo des calcifications des artères coronariennes. Des études récentes ont démontré que les acquisitions UTE permettent de visualiser les calcifications dans des plaques athérosclérotiques ex vivo. Cepandent le mouvement du coeur a entravé jusqu'à maintenant l'utilisation des techniques UTE in vivo. Pour résoudre ce problème nous avons développé une séquence d'acquisition UTE avec trajectoire radiale 3D et l'avons testée sur des volontaires. La technique proposée utilise une auto-navigation 3D pour corriger le mouvement respiratoire et est synchronisée avec l'ECG. Trois échos sont acquis pour extraire le signal de la calcification avec des composants au T2 très court tout en permettant de séparer le signal de la graisse depuis le signal de l'eau. Les résultats sont encore préliminaires mais on peut affirmer que la technique développé peut potentiellement montrer les calcifications des artères coronariennes in vivo. En conclusion, ce travail de thèse présente trois nouvelles techniques pour l'IRM du coeur entier capables d'améliorer la visualisation et la caractérisation de la maladie athérosclérotique des coronaires. Ces techniques fournissent des informations anatomiques et fonctionnelles en quatre dimensions et des informations sur la composition du tissu auparavant indisponibles. CORONARY artery magnetic resonance imaging (MRI) has the potential to provide the cardiologist with relevant diagnostic information relative to coronary artery disease of patients. The major challenge of cardiac MRI, though, is dealing with all sources of motions that can corrupt the images affecting the diagnostic information provided. The current thesis, thus, focused on the development of new MRI techniques that change the standard approach to cardiac motion compensation in order to increase the efficiency of cardioavscular MRI, to provide more flexibility and robustness, new temporal information and new tissue information. The proposed approaches help in advancing coronary magnetic resonance angiography (MRA) in the direction of an easy-to-use and multipurpose tool that can be translated to the clinical environment. The first part of the thesis focused on the study of coronary artery motion through gold standard imaging techniques (x-ray angiography) in patients, in order to measure the precision with which the coronary arteries assume the same position beat after beat (coronary artery repositioning). We learned that intervals with minimal coronary artery repositioning occur in peak systole and in mid diastole and we responded with a new pulse sequence (T2~post) that is able to provide peak-systolic imaging. Such a sequence was tested in healthy volunteers and, from the image quality comparison, we learned that the proposed approach provides coronary artery visualization and contrast-to-noise ratio (CNR) comparable with the standard acquisition approach, but with increased signal-to-noise ratio (SNR). The second part of the thesis explored a completely new paradigm for whole- heart cardiovascular MRI. The proposed techniques acquires the data continuously (free-running), instead of being triggered, thus increasing the efficiency of the acquisition and providing four dimensional images of the whole heart, while respiratory self navigation allows for the scan to be performed in free breathing. This enabling technology allows for anatomical and functional evaluation in four dimensions, with high spatial and temporal resolution and without the need for contrast agent injection. The enabling step is the use of a golden-angle based 3D radial trajectory, which allows for a continuous sampling of the k-space and a retrospective selection of the timing parameters of the reconstructed dataset. The free-running 4D acquisition was then combined with a compressed sensing reconstruction algorithm that further increases the temporal resolution of the 4D dataset, while at the same time increasing the overall image quality by removing undersampling artifacts. The obtained 4D images provide visualization of the whole coronary artery tree in each phases of the cardiac cycle and, at the same time, allow for the assessment of the cardiac function with a single free- breathing scan. The quality of the coronary arteries provided by the frames of the free-running 4D acquisition is in line with the one obtained with the standard ECG-triggered one, and the cardiac function evaluation matched the one measured with gold-standard stack of 2D cine approaches. Finally, the last part of the thesis focused on the development of ultrashort echo time (UTE) acquisition scheme for in vivo detection of calcification in the coronary arteries. Recent studies showed that UTE imaging allows for the coronary artery plaque calcification ex vivo, since it is able to detect the short T2 components of the calcification. The heart motion, though, prevented this technique from being applied in vivo. An ECG-triggered self-navigated 3D radial triple- echo UTE acquisition has then been developed and tested in healthy volunteers. The proposed sequence combines a 3D self-navigation approach with a 3D radial UTE acquisition enabling data collection during free breathing. Three echoes are simultaneously acquired to extract the short T2 components of the calcification while a water and fat separation technique allows for proper visualization of the coronary arteries. Even though the results are still preliminary, the proposed sequence showed great potential for the in vivo visualization of coronary artery calcification. In conclusion, the thesis presents three novel MRI approaches aimed at improved characterization and assessment of atherosclerotic coronary artery disease. These approaches provide new anatomical and functional information in four dimensions, and support tissue characterization for coronary artery plaques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we propose a method for prospective motion correction in MRI using a novel image navigator module, which is triggered by a free induction decay (FID) navigator. Only when motion occurs, the image navigator is run and new positional information is obtained through image registration. The image navigator was specifically designed to match the impact on the magnetization and the acoustic noise of the host sequence. This detection-correction scheme was implemented for an MP-RAGE sequence and 5 healthy volunteers were scanned at 3T while performing various head movements. The correction performance was demonstrated through automated brain segmentation and an image quality index whose results are sensitive to motion artifacts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Clinical trials suggest that intracoronary delivery of autologous bone marrow-derived cells (BMCs) 1-7 days post-acute myocardial infarction (AMI) may improve left ventricular (LV) function. Earlier time points have not been evaluated. We sought to determine the effect of intracoronary autologous BMC on LV function when delivered within 24 h of successful reperfusion therapy. METHODS AND RESULTS: A multi-centre phase II randomized, double-blind, and placebo-controlled trial. One hundred patients with anterior AMI and significant regional wall motion abnormality were randomized to receive either intracoronary infusion of BMC or placebo (1:1) within 24 h of successful primary percutaneous intervention (PPCI). The primary endpoint was the change in left ventricular ejection fraction (LVEF) between baseline and 1 year as determined by advanced cardiac imaging. At 1 year, although LVEF increased compared with baseline in both groups, the between-group difference favouring BMC was small (2.2%; 95% confidence interval, CI: -0.5 to 5.0; P = 0.10). However, there was a significantly greater myocardial salvage index in the BMC-treated group compared with placebo (0.1%; 95% CI: 0.0-0.20; P = 0.048). Major adverse events were rare in both treatment groups. CONCLUSION: The early infusion of intracoronary BMC following PPCI for patients with AMI and regional wall motion abnormality leads to a small non-significant improvement in LVEF when compared with placebo; however, it may play an important role in infarct remodelling and myocardial salvage. CLINICAL TRIAL REGISTRATION: Clinicaltrials.gov NCT00765453 and EudraCT 2007-002144-16.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper a colour texture segmentation method, which unifies region and boundary information, is proposed. The algorithm uses a coarse detection of the perceptual (colour and texture) edges of the image to adequately place and initialise a set of active regions. Colour texture of regions is modelled by the conjunction of non-parametric techniques of kernel density estimation (which allow to estimate the colour behaviour) and classical co-occurrence matrix based texture features. Therefore, region information is defined and accurate boundary information can be extracted to guide the segmentation process. Regions concurrently compete for the image pixels in order to segment the whole image taking both information sources into account. Furthermore, experimental results are shown which prove the performance of the proposed method

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Garlic viruses often occur in complex infections in nature. In this study, a garlic virus complex, collected in fields in Brazil, was purified. RT-PCR was performed using specific primers designed from the consensus regions of the coat protein genes of Onion yellow dwarf virus, a garlic strain (OYDV-G) and Leek yellow stripe virus (LYSV). cDNA of Garlic common latent virus (GCLV) was synthesized using oligo-dT and random primers. By these procedures individual garlic virus genomes were isolated and sequenced. The nucleotide sequence analysis associated with serological data reveals the presence of two Potyvirus OYDV-G and LYSV, and GCLV, a Carlavirus, simultaneously infecting garlic plants. Deduced amino acid sequences of the Brazilian isolates were compared with related viruses reported in different geographical regions of the world. The analysis showed closed relations considering the Brazilian isolates of OYDV-G and GCLV, and large divergence considering LYSV isolate. The detection of these virus species was confirmed by specific reactions observed when coat protein genes of the Brazilian isolates were used as probes in dot-blot and Southern blot hybridization assays. In field natural viral re-infection of virus-free garlic was evaluated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work was aimed at evaluating the possibility of using bromophenol blue as an indicator for detecting the presence of Sclerotinia sclerotiorum in the seeds of dry-beans (Phaseolus vulgaris) and soybean (Glycine max), through incubation of the seeds on an agar medium and "blotter" substrates. The seeds were artificially inoculated with four S. sclerotiorum isolates, plated on the agar medium, named Neon, and on modified Neon agar media all incubated at 14 and 20 ºC for seven days in the dark. Half of the seeds inoculated were surface desinfested prior to plating on the medium. The seeds showing change of colour in the medium, from blue to light yellow, as well as formation of typical mycelium and sclerotia in some cases, were considered to be infected or contaminated by S. sclerotiorum. The two incubation temperatures compared did not show significant (P<0.05) differences in detection level for most of the isolates tested on the different media. According to results obtained in this study, the Neon agar medium with incubation at 14 or 20 ºC has proved to be a reliable and quick method for the detection of S. sclerotiorum mycelium in naturally infected seeds of bean and soybean.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cytomegalovirus (CMV) is the single most important infectious agent affecting recipients of organ transplants. To evaluate the incidence and the clinical importance of CMV infection in renal transplants in Brazil, 37 patients submitted to renal allograft transplants were tested periodically for the presence of cytomegalovirus DNA in urine using the polymerase chain reaction (PCR), and for the presence of IgM and IgG antibodies against CMV by enzyme-linked immunosorbent assay (ELISA) and indirect immunofluorescence (IIF). The PCR-amplified products were detected by gel electrophoresis and confirmed by dot-blot hybridization with oligonucleotide probes. Thirty-two of the 37 patients (86.4%) were positive by at least one of the three methods. In six patients, PCR was the only test which detected the probable CMV infection. Ten patients had a positive result by PCR before transplantation. In general, the diagnosis was achieved earlier by PCR than by serologic tests. Active infection occurred more frequently during the first four months after transplantation. Sixteen of the 32 patients (50%) with active CMV infection presented clinical symptoms consistent with CMV infection. Five patients without evidence of active CMV infection by the three tests had only minor clinical manifestations during follow-up. Our results indicate that PCR is a highly sensitive procedure for the early detection of CMV infection and that CMV infection in renal transplant patients is a frequent problem in Brazil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a fast (less than 3 h) and cost-effective melting temperature assay method for the detection of single-nucleotide polymorphisms in the MBL2 gene. The protocol, which is based on the Corbett Rotor Gene real time PCR platform and SYBR Green I chemistry, yielded, in the cohorts studied, sensitive (100%) and specific (100%) PCR amplification without the use of costly fluorophore-labeled probes or post-PCR manipulation. At the end of the PCR, the dissociation protocol included a slow heating from 60º to 95ºC in 0.2ºC steps, with an 8-s interval between steps. Melting curve profiles were obtained using the dissociation software of the Rotor Gene-3000 apparatus. Samples were analyzed in duplicate and in different PCR runs to test the reproducibility of this technique. No supplementary data handling is required to determine the MBL2 genotype. MBL2 genotyping performed on a cohort of 164 HIV-1-positive Brazilian children and 150 healthy controls, matched for age and sex and ethnic origin, yielded reproducible results confirmed by direct sequencing of the amplicon performed in blind. The three MBL2 variants (Arg52Cys, Gly54Asp, Gly57Glu) were grouped together and called allele 0, while the combination of three wild-type alleles was called allele A. The frequency of the A/A homozygotes was significantly higher among healthy controls (0.68) than in HIV-infected children (0.55; P = 0.0234) and the frequency of MBL2 0/0 homozygotes was higher among HIV-1-infected children than healthy controls (P = 0.0296). The 0 allele was significantly more frequent among the 164 HIV-1-infected children (0.29) than among the 150 healthy controls (0.18; P = 0.0032). Our data confirm the association between the presence of the mutated MBL2 allele (allele 0) and HIV-1 infection in perinatally exposed children. Our results are in agreement with the literature data which indicate that the presence of the allele 0 confers a relative risk of 1.37 for HIV-1 infection through vertical transmission.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although it is widely assumed that temperature affects pollutant toxicity, few studies have actually investigated this relationship. Moreover, such research as has been done has involved constant temperatures; circumstances which are rarely, if ever, actually experienced by north temperate, littoral zone cyprinid species. To investigate the effects of temperature regime on nickel toxicity in goldfish (Carassius auratus L.), 96- and 240-h LCSO values for the heavy metal pollutant, nickel (NiCI2.6H20), were initially determined at 2DoC (22.8 mg/L and 14.7 mg/L in artificially softened water). Constant temperature bioassays at 10°C, 20°C and 30°C were conducted at each of 0, 240-h and 96-h LCSO nickel concentrations for 240 hours. In order to determine the effects of temperature variation during nickel exposure it was imperative that the effects of a single temperature change be investigated before addressing more complex regimes. Single temperature changes of + 10°C or -10°C were imposed at rates of 2°C/h following exposures of between 24 hand 216 h. The effects of a single temperature change on mortality, and duration of toxicant exposure at high and low temperatures were evaluated. The effects of fluctuating temperatures during exposure were investigated through two regimes. The first set of bioassays imposed a sinewave diurnal cycle temperature (20.±.1DOC) throughout the 10 day exposure to 240-h LeSO Ni. The second set of investigations approximated cyprinid movement through the littoral zone by imposing directionally random temperature changes (±2°C at 2-h intervals), between extremes of 10° and 30°C, at 240-h LC50 Ni. Body size (i.e., total length, fork length, and weight) and exposure time were recorded for all fish mortalities. Cumulative mortality curves under constant temperature regimes indicated significantly higher mortality as temperature and nickel concentration were increased. At 1DOC no significant differences in mortality curves were evident in relation to low and high nickel test concentrations (Le., 16 mg/L and 20 mg/L). However at 20°C and 30°C significantly higher mortality was experienced in animals exposed to 20 mg/L Ni. Mortality at constant 10°C was significantly lower than at 30°C with 16 mg/L and was significantly loWer than each of 2DoC and 39°C tanks at 20 mg/L Ni exposure. A single temperature shift from 20°C to 1DoC resulted in a significant decrease in mortality rate and conversely, a single temperature shift from 20°C to 30°C resulted in a significant increase in mortality rate. Rates of mortality recorded during these single temperature shift assays were significantly different from mortality rates obtained under constant temperature assay conditions. Increased Ni exposure duration at higher temperatures resulted in highest mortality. Diurnally cycling temperature bioassays produced cumulative mortality curves approximating constant 20°C curves, with increased mortality evident after peaks in the temperature cycle. Randomly fluctuating temperature regime mortality curves also resembled constant 20°C tanks with mortalities after high temperature exposures (25°C - 30°C). Some test animals survived in all assays with the exception of the 30°C assays, with highest survival associated with low temperature and low Ni concentration. Post-exposure mortality occurred most frequently in individuals which had experienced high Ni concentrations and high temperatures during assays. Additional temperature stress imposed 2 - 12 weeks post exposure resulted in a single death out of 116 individuals suggesting that survivors are capable of surviving subsequent temperature stresses. These investigations suggest that temperature significantly and markedly affects acute nickel toxicity under both constant and fluctuating temperature regimes and plays a role in post exposure mortality and subsequent stress response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to determine which augmented sensory modality would best develop subjective error-detection capabilities of learners performing a spatial-temporal task when using a touch screen monitor. Participants were required to learn a 5-digit key-pressing task in a goal time of 2550 ms over 100 acquisition trials on a touch screen. Participants were randomized into 1 of 4 groups: 1) visual-feedback (colour change of button when selected), 2) auditory-feedback (click sound when button was selected), 3) visual-auditory feedback (both colour change and click sound when button was selected), and 4) no-feedback (no colour change or click sound when button was selected). Following each trial, participants were required to provide a subjective estimate regarding their performance time in relation to the actual time it took for them complete the 5-digit sequence. A no-KR retention test was conducted approximately 24-hours after the last completed acquisition trial. Results showed that practicing a timing task on a touch screen augmented with both visual and auditory information may have differentially impacted motor skill acquisition such that removal of one or both sources of augmented feedback did not result in a severe detriment to timing performance or error detection capabilities of the learner. The present study reflects the importance of multimodal augmented feedback conditions to maximize cognitive abilities for developing a stronger motor memory for subjective error-detection and correction capabilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ce mémoire de maîtrise présente une nouvelle approche non supervisée pour détecter et segmenter les régions urbaines dans les images hyperspectrales. La méthode proposée n ́ecessite trois étapes. Tout d’abord, afin de réduire le coût calculatoire de notre algorithme, une image couleur du contenu spectral est estimée. A cette fin, une étape de réduction de dimensionalité non-linéaire, basée sur deux critères complémentaires mais contradictoires de bonne visualisation; à savoir la précision et le contraste, est réalisée pour l’affichage couleur de chaque image hyperspectrale. Ensuite, pour discriminer les régions urbaines des régions non urbaines, la seconde étape consiste à extraire quelques caractéristiques discriminantes (et complémentaires) sur cette image hyperspectrale couleur. A cette fin, nous avons extrait une série de paramètres discriminants pour décrire les caractéristiques d’une zone urbaine, principalement composée d’objets manufacturés de formes simples g ́eométriques et régulières. Nous avons utilisé des caractéristiques texturales basées sur les niveaux de gris, la magnitude du gradient ou des paramètres issus de la matrice de co-occurrence combinés avec des caractéristiques structurelles basées sur l’orientation locale du gradient de l’image et la détection locale de segments de droites. Afin de réduire encore la complexité de calcul de notre approche et éviter le problème de la ”malédiction de la dimensionnalité” quand on décide de regrouper des données de dimensions élevées, nous avons décidé de classifier individuellement, dans la dernière étape, chaque caractéristique texturale ou structurelle avec une simple procédure de K-moyennes et ensuite de combiner ces segmentations grossières, obtenues à faible coût, avec un modèle efficace de fusion de cartes de segmentations. Les expérimentations données dans ce rapport montrent que cette stratégie est efficace visuellement et se compare favorablement aux autres méthodes de détection et segmentation de zones urbaines à partir d’images hyperspectrales.