988 resultados para gap bilinear diffie hellman problem
Resumo:
Apresentação realizada no 9th European Sociological Association Conference, em Lisboa em 2009
Resumo:
From 1950 to 1990 a total of 45,862 strains (31,517 isolates from human sources, and 14,345 of non-human origin) were identified at Instituto Adolfo Lutz. No prevalence of any serovars was seen during the period 1950-66 among human sources isolates. Important changing pattern was seen in 1968, when S. Typhimurim surprisingly increased becoming the prevalent serovar in the following decades. During the period of 1970-76, S. Typhimurium represented 77.7% of all serovars of human origin. Significant rise in S. Agona isolation as well as in the number of different serovars among human sources strains were seen in the late 70' and the 80's. More than one hundred different serovars were identified among non-human origin strains. Among serovars isolated from human sources, 74.9%, 15.5%, and 3.7% were recovered from stool, blood, and cerebrospinal fluid cultures, respectively. The outbreak of meningitis by S. Grumpensis in the 60's, emphasizes the concept that any Salmonella serovars can be a cause of epidemics, mainly of the nosocomial origin. This evaluation covering a long period shows the important role of the Public Health Laboratory in the surveillance of salmonellosis, one of the most frequent zoonosis in the world.
Resumo:
The minimum interval graph completion problem consists of, given a graph G = ( V, E ), finding a supergraph H = ( V, E ∪ F ) that is an interval graph, while adding the least number of edges |F| . We present an integer programming formulation for solving the minimum interval graph completion problem recurring to a characteri- zation of interval graphs that produces a linear ordering of the maximal cliques of the solution graph.
Resumo:
In this paper we address an order processing optimization problem known as minimization of open stacks (MOSP). We present an integer pro gramming model, based on the existence of a perfect elimination scheme in interval graphs, which finds an optimal sequence for the costumers orders.
Resumo:
Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial Para obtenção do grau de Mestre em Engenharia Informática
Resumo:
A monitorização da qualidade da energia eléctrica tem revelado importância crescente na gestão e caracterização da rede eléctrica. Estudos revelam que os custos directos relacionados com perda de qualidade da energia eléctrica podem representar cerca de 1,5 % do PIB nacional. Para além destes, tem-se adicionalmente os custos indirectos o que se traduz num problema que necessita de minimização. No contexto da minimização dos danos causados pela degradação de energia, são utilizados equipamentos com capacidade de caracterizar a energia eléctrica através da sua monitorização. A utilização destes equipamentos têm subjacente normas de qualidade de energia, que impõem requisitos mínimos de modo a enquadrar e classificar eventos ocorridos na rede eléctrica. Deste modo obtêm-se dados coerentes provenientes de diferentes equipamentos. A monitorização dos parâmetros associados à energia eléctrica é frequentemente realizada através da instalação temporária dos esquipamentos na rede eléctrica, o que resulta numa observação de distúrbios a posteriori da sua ocasião. Esta metodologia não permite detectar o evento eléctrico original mas, quando muito, outros que se espera que sejam semelhantes ao ocorrido. Repare-se, no entanto, que existe um conjunto alargado de eventos que não são repetitivos, constituindo assim uma limitação aquela metodologia. Este trabalho descreve uma alternativa à metodologia de utilização tradicional dos equipamentos. A solução consiste em realizar um analisador de energia que faça parte integrante da instalação e permita a monitorização contínua da rede eléctrica. Este equipamento deve ter um custo suficientemente baixo para que seja justificável nesta utilização alternativa. O analisador de qualidade de energia a desenvolver tem por base o circuito integrado ADE7880, que permite obter um conjunto de parâmetros da qualidade de energia eléctrica de acordo com as normas de energia IEC 61000-4-30 e IEC 61000-4-7. Este analisador permite a recolha contínua de dados específicos da rede eléctrica, e que posteriormente serão armazenados e colocados à disposição do utilizador. Deste modo os dados recolhidos serão apresentados ao utilizador para consulta, de maneira a verificar, de modo continuo a eventual ocorrência das anomalias na rede. Os valores adquiridos podem ainda ser reutilizados vantajosamente para muitas outras finalidades tais como efectuar estudos sobre a optimização energética. O trabalho presentemente desenvolvido decorre de uma utilização alternativa do dispositivo WeSense Energy1 desenvolvido pela equipa da Evoleo Technologies. A presente vertente permite obter parâmetros determinados pelo ADE7880 tais como por exemplo harmónicos, eventos transitórios de tensão e corrente e o desfasamento entre fases, realizando assim uma nova versão do dispositivo, o WeSense Energy2. Adicionalmente este trabalho inclui a visualização remota dos através de uma página web.
Resumo:
The Container Loading Problem (CLP) literature has traditionally evaluated the dynamic stability of cargo by applying two metrics to box arrangements: the mean number of boxes supporting the items excluding those placed directly on the floor (M1) and the percentage of boxes with insufficient lateral support (M2). However, these metrics, that aim to be proxies for cargo stability during transportation, fail to translate real-world cargo conditions of dynamic stability. In this paper two new performance indicators are proposed to evaluate the dynamic stability of cargo arrangements: the number of fallen boxes (NFB) and the number of boxes within the Damage Boundary Curve fragility test (NB_DBC). Using 1500 solutions for well-known problem instances found in the literature, these new performance indicators are evaluated using a physics simulation tool (StableCargo), replacing the real-world transportation by a truck with a simulation of the dynamic behaviour of container loading arrangements. Two new dynamic stability metrics that can be integrated within any container loading algorithm are also proposed. The metrics are analytical models of the proposed stability performance indicators, computed by multiple linear regression. Pearson’s r correlation coefficient was used as an evaluation parameter for the performance of the models. The extensive computational results show that the proposed metrics are better proxies for dynamic stability in the CLP than the previous widely used metrics.
Resumo:
The Rural Postman Problem (RPP) is a particular Arc Routing Problem (ARP) which consists of determining a minimum cost circuit on a graph so that a given subset of required edges is traversed. The RPP is an NP-hard problem with significant real-life applications. This paper introduces an original approach based on Memetic Algorithms - the MARP algorithm - to solve the RPP and, also deals with an interesting Industrial Application, which focuses on the path optimization for component cutting operations. Memetic Algorithms are a class of Metaheuristics which may be seen as a population strategy that involves cooperation and competition processes between population elements and integrates “social knowledge”, using a local search procedure. The MARP algorithm is tested with different groups of instances and the results are compared with those gathered from other publications. MARP is also used in the context of various real-life applications.
Resumo:
1.Pre-assessment data of the patient A 2-year-old boy, weighing 15 kg was admitted with a history of limited mouth opening(inter-incisor distance of 6 mm), hypoplastic and retrognathic mandible (bird face deformity) and facial asymmetry from left temporomandibular joint ankylosis (TMJA). He was born at term, after an uneventful pregnancy, and there was no report of trauma during caesarean section. No other possible aetiologies were identified. He was scheduled for mandibular osteotomy. Preoperative ENT examination revealed adenotonsillar hypertrophy. 2. Anaesthetic Plan A fiberoptic nasal intubation was performed under deep inhalation anaesthesia with sevoflurane, with the patient breathing spontaneously. Midazolam (0.05 mg.kg-1) and alfentanil (0.03 mg.kg-1) were given and anaesthesia was maintained with O2/air and sevoflurane. No neuromuscular blocking agent was administered since the surgical team needed facial nerve monitoring. 3. Description of incident During surgery an accidental extubation occurred and an attempt was made to reintubate the trachea by direct laryngoscopy. Although the osteotomy was nearly completed, the vocal cords could not be visualized (Cormack-Lehane grade IV laryngoscopic view). 4. Solving the problem Re-intubation was finally accomplished with the flexible fiberscope and the procedure was concluded without any more incidents. Extubation was performed 24 hours postoperatively with the patient fully awake. After surgery mouth opening improved to inter-incisor gap of 15 mm. 5. Lessons learned and take home message Two airways issues present in this case can lead to difficultventilation and intubation: TMJA and adenotonsillar hypertrophy. These difficulties were anticipated and managed accordingly. The accidental extubation brought to our attention the fact that, even after surgical correction, this airway remains challenging. Even with intensive jaw stretchingexercises there is a high incidence of re-ankylosis, especially in younger patients. One should bear that in mind when anaesthetizing patients with TMJA.
Resumo:
Leptospira spp. are delicate bacteria that cannot be studied by usual microbiological methods. They cause leptospirosis, a zoonotic disease transmitted to humans through infected urine of wild or domestic animals. We studied the incidence of this disease in the Uruguayan population, its epidemiologic and clinical features, and compared diagnostic techniques. After examining 6,778 suspect cases, we estimated that about 15 infections/100,000 inhabitants occurred yearly, affecting mainly young male rural workers. Awareness about leptospirosis has grown among health professionals, and its lethality has consequently decreased. Bovine infections were probably the principal source of human disease. Rainfall volumes and floods were major factors of varying incidence. Most patients had fever, asthenia, myalgias or cephalalgia, with at least one additional abnormal clinical feature. 30-40% of confirmed cases presented abdominal signs and symptoms, conjunctival suffusion and altered renal or urinary function. Jaundice was more frequent in patients aged > 40 years. Clinical infections followed an acute pattern and their usual outcome was complete recovery. Laboratory diagnosis was based on indirect micro-agglutination standard technique (MAT). Second serum samples were difficult to obtain, often impairing completion of diagnosis. Immunofluorescence was useful as a screening test and for early detection of probable infections.
Resumo:
Dissertação para obtenção do Grau de Mestre em Lógica Computacional
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia e Gestão Industrial