993 resultados para gadolinium
Resumo:
PURPOSE: To determine the feasibility of using a high resolution isotropic three-dimensional (3D) fast T1 mapping sequence for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) to assess osteoarthritis in the hip. MATERIALS AND METHODS: T1 maps of the hip were acquired using both low and high resolution techniques following the administration of 0.2 mmol/kg Gd-DTPA(2-) in 35 patients. Both T1 maps were generated from two separate spoiled GRE images. The high resolution T1 map was reconstructed in the anatomically equivalent plane as the low resolution map. T1 values from the equivalent anatomic regions containing femoral and acetabular cartilages were measured on the low and high resolution maps and compared using regression analysis. RESULTS: In vivo T1 measurements showed a statistically significant correlation between the low and high resolution acquisitions at 1.5 Tesla (R(2) = 0.958, P < 0.001). These results demonstrate the feasibility of using a fast two-angle T1 mapping (F2T1) sequence with isotropic spatial resolution (0.8 x 0.8 x 0.8 mm) for quantitative assessment of biochemical status in articular cartilage of the hip. CONCLUSION: The high resolution 3D F2T1 sequence provides accurate T1 measurements in femoral and acetabular cartilages of the hip, which enables the biochemical assessment of articular cartilage in any plane through the joint. It is a powerful tool for researchers and clinicians to acquire high resolution data in a reasonable scan time (< 30 min).
Resumo:
OBJECTIVES: To evaluate the relationship between T1 after intravenous contrast administration (T1Gd) and Delta relaxation rate (DeltaR1) = (1/T1(Gd) - 1/T1o) in the delayed Gadolinium-Enhanced MRI of cartilage (dGEMRIC) evaluation of cartilage repair tissue. MATERIALS AND METHODS: Thirty single MR examinations from 30 patients after matrix-associated autologous chondrocyte transplantations of the knee joint with different postoperative intervals were examined using an 8-channel knee-coil at 3T. T1 mapping using a 3D GRE sequence with a 35/10 degrees flip angle excitation pulse combination was performed before and after contrast administration (dGEMRIC technique). T1 postcontrast (T1(Gd)) and the DeltaR1 (relative index of pre- and postcontrast R1 value) were calculated for repair tissue and the weight-bearing normal appearing control cartilage. For evaluation of the different postoperative intervals, MR exams were subdivided into 3 groups (up to 12 months, 12-24 months, more than 24 months). For statistical analysis Spearman correlation coefficients were calculated. RESULTS: The mean value for T1 postcontrast was 427 +/- 159 ms, for DeltaR1 1.85 +/- 1.0; in reference cartilage 636 +/- 181 ms for T1 postcontrast and 0.83 +/- 0.5 for DeltaR1.The correlation coefficients were highly significant between T1 (Gd) and DeltaR1 for repair tissue (0.969) as well as normal reference cartilage (0.928) in total, and for the reparative cartilage in the early, middle postoperative, and late postoperative interval after surgery (R values: -0.986, -0.970, and -0.978, respectively). Using either T1(Gd) or DeltaR1, the 2 metrics resulted in similar conclusions regarding the time course of change of repair tissue and control tissue, namely that highly significant (P > 0.01) differences between cartilage repair tissue and reference cartilage were found for all follow-up groups. Additionally, for both metrics highly significant differences (P < 0.01) between early follow up and the 2 later postoperative groups for cartilage repair tissue were found. No statistical differences were found between the 2 later follow-up groups of reparative cartilage either for T1 (Gd) or DeltaR1. CONCLUSION: The high correlation between T1 (Gd) and DeltaR1 and the comparable conclusions reached utilizing metric implies that T1 mapping before intravenous administration of MR contrast agent is not necessary for the evaluation of repair tissue. This will help to reduce costs, inconvenience for the patients, simplifies the examination procedure, and makes dGEMRIC more attractive for follow-up of patients after cartilage repair surgeries.
Resumo:
OBJECTIVE: The purpose of this study was to delineate the anatomy of the precentral cerebellar vein, superior vermian vein, and internal occipital vein using reconstructions of computed tomographic and magnetic resonance imaging scans with navigation software. These data were compared with previous anatomic and angiographic findings to show the resolution and accuracy of the system. METHODS: We retrospectively reviewed 100 patients with intracranial pathologies (50 computed tomographic scans with contrast and 50 magnetic resonance imaging scans with gadolinium) using a neuronavigation workstation for 3-dimensional reconstruction. Particular attention was paid to depiction of the precentral cerebellar vein, superior vermian vein, and internal occipital vein. The data were reviewed and analyzed. RESULTS: The precentral cerebellar vein, superior vermian vein, and its tributary, the supraculminate vein, were depicted in 52 (52%) patients. The internal occipital vein was delineated on 99 (49.5%) sides and joined the basal vein and vein of Galen in 39 (39.4%) and 60 (60.6%) hemispheres, respectively. Comparing these results with previous angiographic studies, the ability of the neuronavigation system for depicting these vessels is similar to that of digital subtraction angiography. CONCLUSION: This study illustrates the possibility of depicting the small vessels draining into the pineal region venous complex using 3-dimensional neuronavigation with an accuracy comparable to that of digital subtraction angiography. This tool provides important information for both surgical planning and intraoperative orientation.
Resumo:
BACKGROUND: A precise, non-invasive, non-toxic, repeatable, convenient and inexpensive follow-up of renal transplants, especially following biopsies, is in the interest of nephrologists. Formerly, the rate of biopsies leading to AV fistulas had been underestimated. Imaging procedures suited to a detailed judgement of these vascular malformations are to be assessed. METHODS: Three-dimensional (3D) reconstruction techniques of ultrasound flow-directed and non-flow-directed energy mode pictures were compared with a standard procedure, gadolinium-enhanced nuclear magnetic resonance imaging angiography (MRA) using the phase contrast technique. RESULTS: Using B-mode and conventional duplex information, AV fistulas were localized in the upper pole of the kidney transplant of the index patient. The 3D reconstruction provided information about the exact localization and orientation of the fistula in relation to other vascular structures, and the flow along the fistula. The MRA provided localization and orientation information, but less functional information. Flow-directed and non-flow-directed energy mode pictures could be reconstructed to provide 3D information about vascular malformations in transplanted kidneys. CONCLUSION: In transplanted kidneys, 3D-ultrasound angiography may be equally as effective as MRA in localizing and identifying AV malformations. Advantages of the ultrasound method are that it is cheaper, non-toxic, non-invasive, more widely availability and that it even provides more functional information. Future prospective studies will be necessary to evaluate the two techniques further.
Resumo:
Future clinical trials investigating the natural history and treatment of femoroacetabular impingement (FAI) will require multimodal staging systems for hip osteoarthritis because the optimal system will differ based on the size of the study population, the specific objective in question, and the time frame in which the investigator expects to see the specified end point. Plain radiographs are readily available, low in cost, and of unquestioned validity, but they are relatively insensitive to early joint damage. MRI allows assessment of both bony and soft-tissue pathology within the joint, and it is much more sensitive for early joint damage because cartilage is visualized directly. Biochemical imaging techniques such as delayed gadolinium-enhanced MRI of cartilage, T2 mapping, and T1rho offer the potential to identify biochemical damage to cartilage before the onset of irreversible tissue loss. In the future, biomarkers may allow earlier detection of osteoarthritis before the development of radiographic evidence of disease.
Resumo:
We report the detailed documented case of a 57-year-old homosexual HIV-positive man with bilateral cochleovestibular deficits as a first symptom of syphilis infection in early stage II disease. As a morphological substrate, a strong enhancement of both inner ears and vestibulocochlear nerves were found on gadolinium-enhanced MR scans. The serological tests identified an active infection with Treponema pallidum. After a high-dose treatment with penicillin G and prednisolone, the auditory and vestibular functions and the MR morphology of the vestibulocochlear nerves and inner ears on both sides returned to normal.
Resumo:
High resolution, vascular magnetic resonance imaging of the spine region in small animals poses several challenges. The small anatomical features, extravascular diffusion, and the low signal-to-noise ratio limit the use of conventional contrast agents. We hypothesize that a long circulating, intravascular liposomal-encapsulated MR contrast agent (liposomal-Gd) would facilitate visualization of small anatomical features of the perispinal vasculature not visible with conventional contrast agent (Gd-DTPA).
Resumo:
BACKGROUND AND PURPOSE: High-resolution, vascular MR imaging of the spine region in small animals poses several challenges. The small anatomic features, extravascular diffusion, and low signal-to-noise ratio limit the use of conventional contrast agents. We hypothesize that a long-circulating, intravascular liposomal-encapsulated MR contrast agent (liposomal-Gd) would facilitate visualization of small anatomic features of the perispinal vasculature not visible with conventional contrast agent (gadolinium-diethylene-triaminepentaacetic acid [Gd-DTPA]). METHODS: In this study, high-resolution MR angiography of the spine region was performed in a rat model using a liposomal-Gd, which is known to remain within the blood pool for an extended period. The imaging characteristics of this agent were compared with those of a conventional contrast agent, Gd-DTPA. RESULTS: The liposomal-Gd enabled acquisition of high quality angiograms with high signal-to-noise ratio. Several important vascular features, such as radicular arteries, posterior spinal vein, and epidural venous plexus were visualized in the angiograms obtained with the liposomal agent. The MR angiograms obtained with conventional Gd-DTPA did not demonstrate these vessels clearly because of marked extravascular soft-tissue enhancement that obscured the vasculature. CONCLUSIONS: This study demonstrates the potential benefit of long-circulating liposomal-Gd as a MR contrast agent for high-resolution vascular imaging applications.
Resumo:
OBJECTIVES This study aimed to demonstrate that the presence of late gadolinium enhancement (LGE) is a predictor of death and other adverse events in patients with suspected cardiac sarcoidosis. BACKGROUND Cardiac sarcoidosis is the most important cause of patient mortality in systemic sarcoidosis, yielding a 5-year mortality rate between 25% and 66% despite immunosuppressive treatment. Other groups have shown that LGE may hold promise in predicting future adverse events in this patient group. METHODS We included 155 consecutive patients with systemic sarcoidosis who underwent cardiac magnetic resonance (CMR) for workup of suspected cardiac sarcoid involvement. The median follow-up time was 2.6 years. Primary endpoints were death, aborted sudden cardiac death, and appropriate implantable cardioverter-defibrillator (ICD) discharge. Secondary endpoints were ventricular tachycardia (VT) and nonsustained VT. RESULTS LGE was present in 39 patients (25.5%). The presence of LGE yields a Cox hazard ratio (HR) of 31.6 for death, aborted sudden cardiac death, or appropriate ICD discharge, and of 33.9 for any event. This is superior to functional or clinical parameters such as left ventricular (LV) ejection fraction (EF), LV end-diastolic volume, or presentation as heart failure, yielding HRs between 0.99 (per % increase LVEF) and 1.004 (presentation as heart failure), and between 0.94 and 1.2 for potentially lethal or other adverse events, respectively. Except for 1 patient dying from pulmonary infection, no patient without LGE died or experienced any event during follow-up, even if the LV was enlarged and the LVEF severely impaired. CONCLUSIONS Among our population of sarcoid patients with nonspecific symptoms, the presence of myocardial scar indicated by LGE was the best independent predictor of potentially lethal events, as well as other adverse events, yielding a Cox HR of 31.6 and of 33.9, respectively. These data support the necessity for future large, longitudinal follow-up studies to definitely establish LGE as an independent predictor of cardiac death in sarcoidosis, as well as to evaluate the incremental prognostic value of additional parameters.
Resumo:
Over the last two decades, imaging of the aorta has undergone a clinically relevant change. As part of the change non-invasive imaging techniques have replaced invasive intra-arterial digital subtraction angiography as the former imaging gold standard for aortic diseases. Computed tomography (CT) and magnetic resonance imaging (MRI) constitute the backbone of pre- and postoperative aortic imaging because they allow for imaging of the entire aorta and its branches. The first part of this review article describes the imaging principles of CT and MRI with regard to aortic disease, shows how both technologies can be applied in every day clinical practice, offering exciting perspectives. Recent CT scanner generations deliver excellent image quality with a high spatial and temporal resolution. Technical developments have resulted in CT scan performed within a few seconds for the entire aorta. Therefore, CT angiography (CTA) is the imaging technology of choice for evaluating acute aortic syndromes, for diagnosis of most aortic pathologies, preoperative planning and postoperative follow-up after endovascular aortic repair. However, radiation dose and the risk of contrast induced nephropathy are major downsides of CTA. Optimisation of scan protocols and contrast media administration can help to reduce the required radiation dose and contrast media. MR angiography (MRA) is an excellent alternative to CTA for both diagnosis of aortic pathologies and postoperative follow-up. The lack of radiation is particularly beneficial for younger patients. A potential side effect of gadolinium contrast agents is nephrogenic systemic fibrosis (NSF). In patients with high risk of NSF unenhanced MRA can be performed with both ECG- and breath-gating techniques. Additionally, MRI provides the possibility to visualise and measure both dynamic and flow information.
Resumo:
OBJECTIVES Susceptibility-weighted imaging (SWI) enables visualization of thrombotic material in acute ischemic stroke. We aimed to validate the accuracy of thrombus depiction on SWI compared to time-of-flight MRA (TOF-MRA), first-pass gadolinium-enhanced MRA (GE-MRA) and digital subtraction angiography (DSA). Furthermore, we analysed the impact of thrombus length on reperfusion success with endovascular therapy. METHODS Consecutive patients with acute ischemic stroke due to middle cerebral artery (MCA) occlusions undergoing endovascular recanalization were screened. Only patients with a pretreatment SWI were included. Thrombus visibility and location on SWI were compared to those on TOF-MRA, GE-MRA and DSA. The association between thrombus length on SWI and reperfusion success was studied. RESULTS Eighty-four of the 88 patients included (95.5 %) showed an MCA thrombus on SWI. Strong correlations between thrombus location on SWI and that on TOF-MRA (Pearson's correlation coefficient 0.918, P < 0.001), GE-MRA (0.887, P < 0.001) and DSA (0.841, P < 0.001) were observed. Successful reperfusion was not significantly related to thrombus length on SWI (P = 0.153; binary logistic regression). CONCLUSIONS In MCA occlusion thrombus location as seen on SWI correlates well with angiographic findings. In contrast to intravenous thrombolysis, thrombus length appears to have no impact on reperfusion success of endovascular therapy. KEY POINTS • SWI helps in assessing location and length of thrombi in the MCA • SWI, MRA and DSA are equivalent in detecting the MCA occlusion site • SWI is superior in identifying the distal end of the thrombus • Stent retrievers should be deployed over the distal thrombus end • Thrombus length did not affect success of endovascular reperfusion guided by SWI.
Resumo:
BACKGROUND The pathogenesis of full-thickness tears of the rotator cuff remains unclear. Apart from age and trauma, distinct scapular morphologies have been found to be associated with rotator cuff disease. The purpose of the present study was to evaluate whether a score formed using these established risk factors was able to predict the presence of a rotator cuff tear reliably. METHODS We retrospectively assessed a consecutive series of patients with a minimal age of 40 years old, who had true antero-posterior (AP) radiographs of their shoulders, as well as a magnetic resonance (MR) gadolinium-arthrography, between January and December 2011. In all of these patients, the critical shoulder angle (CSA) was determined, and MR images were assessed for the presence of rotator cuff tears. Additionally, the patients' charts were reviewed to obtain details of symptom onset. Based on these factors, the so-called rotator cuff tear (RCT) score was calculated. RESULTS Patients with full-thickness RCTs were significantly older and had significantly larger CSAs than patients with intact rotator cuffs. Multiple logistic regression, using trauma, age and CSA as independent variables, revealed areas under the curve (AUCs) for trauma of 0.55, for age of 0.65 and for CSA of 0.86. The combination of all three factors was the most powerful predictor, with an AUC of 0.92. CONCLUSION Age, trauma and the CSA can accurately predict the presence of a posterosuperior RCT. LEVEL OF EVIDENCE Level IV. Case series with no comparison groups.
Resumo:
BACKGROUND AND PURPOSE The prevalence and clinical importance of primarily fragmented thrombi in patients with acute ischemic stroke remains elusive. Whole-brain SWI was used to detect multiple thrombus fragments, and their clinical significance was analyzed. MATERIALS AND METHODS Pretreatment SWI was analyzed for the presence of a single intracranial thrombus or multiple intracranial thrombi. Associations with baseline clinical characteristics, complications, and clinical outcome were studied. RESULTS Single intracranial thrombi were detected in 300 (92.6%), and multiple thrombi, in 24 of 324 patients (7.4%). In 23 patients with multiple thrombi, all thrombus fragments were located in the vascular territory distal to the primary occluding thrombus; in 1 patient, thrombi were found both in the anterior and posterior circulation. Only a minority of thrombus fragments were detected on TOF-MRA, first-pass gadolinium-enhanced MRA, or DSA. Patients with multiple intracranial thrombi presented with more severe symptoms (median NIHSS scores, 15 versus 11; P = .014) and larger ischemic areas (median DWI ASPECTS, 5 versus 7; P = .006); good collaterals, rated on DSA, were fewer than those in patients with a single thrombus (21.1% versus 44.2%, P = .051). The presence of multiple thrombi was a predictor of unfavorable outcome at 3 months (P = .040; OR, 0.251; 95% CI, 0.067-0.939). CONCLUSIONS Patients with multiple intracranial thrombus fragments constitute a small subgroup of patients with stroke with a worse outcome than patients with single thrombi.
Resumo:
We report on the developments of a neutron tomography setup at the instrument for prompt gamma-ray activation analysis (PGAA) at the Maier-Leibnitz Zentrum(MLZ). The recent developments are driven by the idea of combining the spatial information obtained with neutron tomography with the elemental information determined with PGAA, i.e. to further combine both techniques to an investigative technique called prompt gamma activation imaging (PGAI).At the PGAA instrument, a cold neutron flux of up to 6 x 1010 cm-2 s-1 (thermal equivalent) is available in the focus of an elliptically tapered neutron guide. In the reported experiments, the divergence of the neutron beam was investigated, the resolution of the installed detector system tested, and a proof-of-principle tomography experiment performed. In our study a formerly used camera box was upgraded with a better camera and an optical resolution of 8 line pairs/mm was achieved. The divergence of the neutron beam was measured by a systematic scan along the beam axis. Based on the acquired data, a neutron imaging setup with a L/D ratio of 200 was installed. The resolution of the setup was testedin combination with a gadolinium test target and different scintillator screens. The test target was irradiated at two positions to determine the maximum resolution and the resolution at the actual sample position. The performance of the installed tomography setup was demonstrated bya tomography experiment of an electric amplifier tube.
Resumo:
INTRODUCTION Left ventricular thrombus (LVT) formation may worsen the post-infarct outcome as a result of thromboembolic events. It also complicates the use of modern antiplatelet regimens, which are not compatible with long-term oral anticoagulation. The knowledge of the incidence of LVT may therefore be of importance to guide antiplatelet and antithrombotic therapy after acute myocardial infarction (AMI). METHODS In 177 patients with large, mainly anterior AMI, standard cardiac magnetic resonance imaging (CMR) including cine and late gadolinium enhancement (LGE) imaging was performed shortly after AMI as per protocol. CMR images were analysed at an independent core laboratory blinded to the clinical data. Transthoracic echocardiography (TTE) was not mandatory for the trial, but was performed in 64% of the cases following standard of care. In a logistic model, 3 out of 61 parameters were used in a multivariable model to predict LVT. RESULTS LVT was detected by use of CMR in 6.2% (95% confidence interval [CI] 3.1%-10.8%). LGE sequences were best to detect LVT, which may be missed in cine sequences. We identified body mass index (odds ratio 1.18; p = 0.01), baseline platelet count (odds ratio 1.01, p = 0.01) and infarct size as assessed by use of CMR (odds ratio 1.03, p = 0.02) as best predictors for LVT. The agreement between TTE and CMR for the detection of LVT is substantial (kappa = 0.70). DISCUSSION In the current analysis, the incidence of LVT shortly after AMI is relatively low, even in a patient population at high risk. An optimal modality for LVT detection is LGE-CMR but TTE has an acceptable accuracy when LGE-CMR is not available.