930 resultados para extraction methods
Resumo:
The European “Community Bureau of Reference” (BCR) sequential extraction procedure, diffusive gradient in thin-films technique (DGT), and physiologically based extraction test were applied to assess metal bioavailability in sediments of Lake Taihu (n = 13). Findings from the three methods showed that Cd was a significant problem in the western lake whereas Cu, Zn, and Ni pollution was most severe in the northern lake. Results from the sequential extraction revealed that more than 50 % of the Cu and Zn were highly mobile and defined within the extractable fraction (AS1 + FM2 + OS3) in the majority of the sediments, in contrast extractable fractions of Ni and Cd were lower than 50 % in most of the sampling sites. Average Cu, Zn, Ni, and Cd bioaccessibilities were <50 % in the gastric phase. Zn and Cd bioaccessibility in the intestinal phase was ∼50 % lower than the gastric phase while bioaccessibilities of Cu and Ni were 47–57 % greater than the gastric phase. Linear regression analysis between DGT and BCR measurements indicated that the extractable fractions (AS1 + FM2 + OS3) in the reducing environment were the main source of DGT uptake, suggesting that DGT is a good in situ evaluation tool for metal bioavailability in sediments.
Resumo:
Desulfurization is one of the most important processes in the refining industry. Due to a growing concern about the risks to human health and environment, associated with the emissions of sulfur compounds, legislation has become more stringent, requiring a drastic reduction in the sulfur content of fuel to levels close to zero (< 10 ppm S). However, conventional desulfurization processes are inefficient and have high operating costs. This scenario stimulates the improvement of existing processes and the development of new and more efficient technologies. Aiming at overcoming these shortcomings, this work investigates an alternative desulfurization process using ionic liquids for the removal of mercaptans from "jet fuel" streams. The screening and selection of the most suitable ionic liquid were performed based on experimental and COSMO-RS predicted liquid-liquid equilibrium data. A model feed of 1-hexanethiol and n-dodecane was selected to represent a jet-fuel stream. High selectivities were determined, as a result of the low mutual solubility between the ionic liquid and the hydrocarbon matrix, proving the potential use of the ionic liquid, which prevents the loss of fuel for the solvent. The distribution ratios of mercaptans towards the ionic liquids were not as favorable, making the traditional liquid-liquid extraction processes not suitable for the removal of aliphatic S-compounds due to the high volume of extractant required. This work explores alternative methods and proposes the use of ionic liquids in a separation process assisted by membranes. In the process proposed the ionic liquid is used as extracting solvent of the sulfur species, in a hollow fiber membrane contactor, without co-extracting the other jet-fuel compound. In a second contactor, the ionic liquid is regenerated applying a sweep gas stripping, which allows for its reuse in a closed loop between the two membrane contactors. This integrated extraction/regeneration process of desulfurization produced a jet-fuel model with sulfur content lower than 2 ppm of S, as envisaged by legislation for the use of ultra-low sulfur jet-fuel. This result confirms the high potential for development of ultra-deep desulfurization application.
Resumo:
The main objective of the present work is the study of a profitable process not only in the extraction and selective separation of lycopene and β-carotene, two compounds present in tomato, but also in its potential application to food industry wastes. This is one of the industries that produce larger amounts of wastes, which are rich in high value biomolecules with great economic interest. However, the conventional methods used to extract this kind of compounds are expensive which limits their application at large scale. Lycopene and βcarotene are carotenoids with high commercial value, known for their antioxidant activity and benefits to human health. Their biggest source is tomato, one of the world’s most consumed fruits, reason for which large quantities of waste is produced. This work focuses on the study of diverse solvents with a high potential to extract carotenoids from tomato, as well as the search for more environmentally benign solvents than those currently used to extract lycopene and β-carotene from biomass. Additionally, special attention was paid to the creation of a continuous process that would allow the fractionation of the compounds for further purification. Thus, the present work started with the extraction of both carotenoids using a wide range of solvents, namely, organic solvents, conventional salts, ionic liquids, polymers and surfactants. In this stage, each solvent was evaluated in what regards their capacity of extraction as well as their penetration ability in biomass. The results collected showed that an adequate selection of the solvents may lead to the complete extraction of both carotenoids in one single step, particularly acetone and tetrahydrofuran were the most effective ones. However, the general low penetration capacity of salts, ionic liquids, polymers and surfactants makes these solvents ineffective in the solid-liquid extraction process. As the organic solvents showed the highest capacity to extract lycopene and βcarotene, in particular tetrahydrofuran and acetone, the latter solvent used in the development process of fractionation, using to this by strategic use of solvents. This step was only successfully developed through the manipulation of the solubility of each compound in ethanol and n-hexane. The results confirmed the possibility of fractionating the target compounds using the correct addition order of the solvents. Approximately, 39 % of the β-carotene was dissolved in ethanol and about 64 % of lycopene was dissolved in n-hexane, thus indicating their separation for two different solvents which shows the selective character of the developed process without any prior stage optimization. This study revealed that the use of organic solvents leads to selective extraction of lycopene and β-carotene, allowing diminishing the numerous stages involved in conventional methods. At the end, it was possible to idealize a sustainable and of high industrial relevance integrated process, nevertheless existing the need for additional optimization studies in the future.
Resumo:
Tese de doutoramento, Informática (Engenharia Informática), Universidade de Lisboa, Faculdade de Ciências, 2014
Resumo:
Tese de doutoramento, Medicina Dentária (Periodontologia), Universidade de Lisboa, Faculdade de Medicina Dentária, 2016
Resumo:
GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.
Resumo:
As an introduction to a series of articles focused on the exploration of particular tools and/or methods to bring together digital technology and historical research, the aim of this paper is mainly to highlight and discuss in what measure those methodological approaches can contribute to improve analytical and interpretative capabilities available to historians. In a moment when the digital world present us with an ever-increasing variety of tools to perform extraction, analysis and visualization of large amounts of text, we thought it would be relevant to bring the digital closer to the vast historical academic community. More than repeating an idea of digital revolution introduced in the historical research, something recurring in the literature since the 1980s, the aim was to show the validity and usefulness of using digital tools and methods, as another set of highly relevant tools that the historians should consider. For this several case studies were used, combining the exploration of specific themes of historical knowledge and the development or discussion of digital methodologies, in order to highlight some changes and challenges that, in our opinion, are already affecting the historians' work, such as a greater focus given to interdisciplinarity and collaborative work, and a need for the form of communication of historical knowledge to become more interactive.
Resumo:
Captan and folpet are fungicides largely used in agriculture. They have similar chemical structures, except that folpet has an aromatic ring unlike captan. Their half-lives in blood are very short, given that they are readily broken down to tetrahydrophthalimide (THPI) and phthalimide (PI), respectively. Few authors measured these biomarkers in plasma or urine, and analysis was conducted either by gas chromatography coupled to mass spectrometry or liquid chromatography with UV detection. The objective of this study was thus to develop simple, sensitive and specific liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) methods to quantify both THPI and PI in human plasma and urine. Briefly, deuterated THPI was added as an internal standard and purification was performed by solid-phase extraction followed by LC/APCI-MS/MS analysis in negative ion mode for both compounds. Validation of the methods was conducted using spiked blank plasma and urine samples at concentrations ranging from 1 to 250 μg/L and 1 to 50 μg/L, respectively, along with samples of volunteers and workers exposed to captan or folpet. The methods showed a good linearity (R (2) > 0.99), recovery (on average 90% for THPI and 75% for PI), intra- and inter-day precision (RSD, <15%) and accuracy (<20%), and stability. The limit of detection was 0.58 μg/L in urine and 1.47 μg/L in plasma for THPI and 1.14 and 2.17 μg/L, respectively, for PI. The described methods proved to be accurate and suitable to determine the toxicokinetics of both metabolites in human plasma and urine.
Resumo:
In forensic investigation of firearm-related cases, determination of the residual amount of volatile compounds remaining inside a cartridge could be useful in estimating the time since its discharge. Published approaches are based on following the decrease of selected target compounds as a function of time by using solid phase micro-extraction (SPME). Naphthalene, as well as an unidentified decomposition product of nitrocellulose (referred to as "TEA2"), are usually employed for this purpose. However, reliability can be brought into question given their high volatility and the low reproducibility of their extracted quantities. In order to identify alternatives and therefore develop improved dating methods, an extensive study on the composition and variability of volatile residues in nine different types of cartridges was carried out. Analysis was performed using headspace sorptive extraction (HSSE), which is a more exhaustive technique compared to SPME. 166 compounds were identified (several of which for the first time), and it was observed that the final compositional characteristics of each residue were strongly dependent on its source. Variability of single identified compounds within and between different types of cartridge, as well as their evolution over time, was also studied. Many explosion products containing up to 4 aromatic rings were found to be globally present in high proportions amongst residues. 27 of them (excluding naphthalene) also presented detectable decreases during the first 24 h. Therefore, they could be used as complementary target analytes in future dating methods.
Resumo:
Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.
Resumo:
Second-rank tensor interactions, such as quadrupolar interactions between the spin- 1 deuterium nuclei and the electric field gradients created by chemical bonds, are affected by rapid random molecular motions that modulate the orientation of the molecule with respect to the external magnetic field. In biological and model membrane systems, where a distribution of dynamically averaged anisotropies (quadrupolar splittings, chemical shift anisotropies, etc.) is present and where, in addition, various parts of the sample may undergo a partial magnetic alignment, the numerical analysis of the resulting Nuclear Magnetic Resonance (NMR) spectra is a mathematically ill-posed problem. However, numerical methods (de-Pakeing, Tikhonov regularization) exist that allow for a simultaneous determination of both the anisotropy and orientational distributions. An additional complication arises when relaxation is taken into account. This work presents a method of obtaining the orientation dependence of the relaxation rates that can be used for the analysis of the molecular motions on a broad range of time scales. An arbitrary set of exponential decay rates is described by a three-term truncated Legendre polynomial expansion in the orientation dependence, as appropriate for a second-rank tensor interaction, and a linear approximation to the individual decay rates is made. Thus a severe numerical instability caused by the presence of noise in the experimental data is avoided. At the same time, enough flexibility in the inversion algorithm is retained to achieve a meaningful mapping from raw experimental data to a set of intermediate, model-free
Resumo:
Cette recherche porte sur la lexicologie, la lexicographie et l’enseignement/apprentissage du lexique. Elle s’inscrit dans le cadre du projet Modélisation ontologique des savoirs lexicographiques en vue de leur application en linguistique appliquée, surnommé Lexitation, qui est, à notre connaissance, la première tentative d’extraction des savoirs lexicographiques — i.e. connaissances déclaratives et procédurales utilisées par des lexicographes — utilisant une méthode expérimentale. Le projet repose sur le constat que les savoirs lexicographiques ont un rôle crucial à jouer en lexicologie, mais aussi en enseignement/apprentissage du lexique. Dans ce mémoire, nous décrirons les méthodes et les résultats de nos premières expérimentations, effectuées à l’aide du Think Aloud Protocol (Ericsson et Simon, 1993). Nous expliquerons l’organisation générale des expérimentations et comment les savoirs lexicographiques extraits sont modélisés pour former une ontologie. Finalement, nous discuterons des applications possibles de nos travaux en enseignement du lexique, plus particulièrement pour la formation des maîtres.
Resumo:
La documentation des programmes aide les développeurs à mieux comprendre le code source pendant les tâches de maintenance. Toutefois, la documentation n’est pas toujours disponible ou elle peut être de mauvaise qualité. Le recours à la redocumentation s’avère ainsi nécessaire. Dans ce contexte, nous proposons de faire la redocumentation en générant des commentaires par application de techniques de résumé par extraction. Pour mener à bien cette tâche, nous avons commencé par faire une étude empirique pour étudier les aspects quantitatifs et qualitatifs des commentaires. En particulier, nous nous sommes intéressés à l’étude de la distribution des commentaires par rapport aux différents types d’instructions et à la fréquence de documentation de chaque type. Aussi, nous avons proposé une taxonomie de commentaires pour classer les commentaires selon leur contenu et leur qualité. Suite aux résultats de l’étude empirique, nous avons décidé de résumer les classes Java par extraction des commentaires des méthodes/constructeurs. Nous avons défini plusieurs heuristiques pour déterminer les commentaires les plus pertinents à l’extraction. Ensuite, nous avons appliqué ces heuristiques sur les classes Java de trois projets pour en générer les résumés. Enfin, nous avons comparé les résumés produits (les commentaires produits) à des résumés références (les commentaires originaux) en utilisant la métrique ROUGE.
Resumo:
La phosphorylation des protéines constitue l’une des plus importantes modifications post-traductionnelles (PTMs) et intervient dans de multiples processus physiologiques tels, la croissance, la différenciation cellulaire, l’apoptose, etc. En dépit de son importance, l’analyse des phosphoprotéines demeure une tâche difficile en raison de leur nature dynamique (car la phosphorylation des protéines est un processus réversible) et de leur faible abondance relative. En effet, la détermination des sites de phosphorylation est souvent difficile car les phosphopeptides sont souvent difficiles à détecter par des méthodes d’analyse chromatographique classique et par spectrométrie de masse (MS). De récentes études ont démontré que les nombreuses méthodes d’enrichissement de phosphopeptides existantes ne sont pas complètes, et que le nombre total de phosphopeptides détectés ne chevauchent pas complètement ces méthodes. C’est pour cela qu’il existe une nécessité de combler les lacunes des méthodes d’enrichissement existantes afin d’avoir des analyses phosphoprotéomiques plus complètes. Dans cette étude, nous avons utilisé les liquides ioniques (LI), plus particulièrement les sels d’imidazolium, comme une technique d’enrichissement alternative, dans le but de favoriser une extraction sélective de phosphopeptides présents en solution. Les sels d’imidazolium ont donc été utilisés en raison de leurs propriétés physico-chimiques "facilement" ajustables selon la nature des substituants sur le noyau imidazolium et la nature de l’anion. Les sels de monoimidazolium et de bis-imidazolium possédant respectivement des chaînes linéaires à 4, 12 et 16 atomes de carbone et ayant différents anions ont été synthétisés et utilisés pour effectuer des extractions liquide-liquide et solide-liquide des phosphopeptides en solution. Dans un premier temps, des extractions liquide-liquide ont été réalisées en utilisant un liquide ionique (LI) ayant une chaine linéaire de 4 atomes de carbone. Ces extractions réalisées avec le bis(trifluoromethanesulfonyl) amide de 3-butyl-1-methylimidazolium (BMIM-NTf2) et l’hexafluorophosphate de 3-butyl-1-methylimidazolium (BMIM-PF6) n’ont pas montré une extraction notable du PPS comparativement au PN. Dans un deuxième temps, des extractions solide-liquide ont été réalisées en fonctionnalisant des particules solides avec des sels d’imidazolium possédant des chaines linéaires de 12 ou 16 atomes de carbone. Ces extractions ont été faites en utilisant un phosphopentapeptide Ac-Ile-pTyr-Gly-Glu-Phe-NH2 (PPS) en présence de 2 analogues acides non-phosphorylés. Il a été démontré que les sels d’imidazolium à chaine C12 étaient meilleurs pour extraire le PPS que les deux autres peptides PN (Ac-Ile-Tyr-Gly-Glu-Phe-NH2) et PE (Ac-Glu-Tyr-Gly-Glu-Phe-NH2) L’électrophorèse capillaire (CE) et la chromatographie liquide à haute performance couplée à la spectrométrie de masse (LC-MS) ont été utilisées pour quantifier le mélange des trois peptides avant et après extraction ; dans le but de mesurer la sélectivité et l’efficacité d’extraction de ces peptides par rapport à la composition chimique du liquide ionique utilisé.
Resumo:
Solid phase extraction (SPE) is a powerful technique for preconcentration/removal or separation of trace and ultra trace amounts of toxic and nutrient elements. SPE effectively simplifies the labour intensive sample preparation, increase its reliability and eliminate the clean up step by using more selective extraction procedures. The synthesis of sorbents with a simplified procedure and diminution of the risks of errors shows the interest in the areas of environmental monitoring, geochemical exploration, food, agricultural, pharmaceutical, biochemical industry and high purity metal designing, etc. There is no universal SPE method because the sample pretreatment depends strongly on the analytical demand. But there is always an increasing demand for more sensitive, selective, rapid and reliable analytical procedures. Among the various materials, chelate modified naphthalene, activated carbon and chelate functionalized highly cross linked polymers are most important. In the biological and environmental field, large numbers of samples are to be analysed within a short span of time. Hence, online flow injection methods are preferred as they allow extraction, separation, identification and quantification of many numbers of analytes. The flow injection online preconcentration flame AAS procedure developed allows the determination of as low as 0.1 µg/l of nickel in soil and cobalt in human hair samples. The developed procedure is precise and rapid and allows the analysis of 30 samples per hour with a loading time of 60 s. The online FI manifold used in the present study permits high sampling, loading rates and thus resulting in higher preconcentration/enrichment factors of -725 and 600 for cobalt and nickel respectively with a 1 min preconcentration time compared to conventional FAAS signal. These enrichment factors are far superior to hitherto developed on line preconcentration procedures for inorganics. The instrumentation adopted in the present study allows much simpler equipment and low maintenance costs compared to costlier ICP-AES or ICP-MS instruments.