764 resultados para external validity
Resumo:
In 2015 the UN Secretary-General established an External Independent Review to review how the United Nations has responded to allegations of child sexual exploitation and child sexual abuse, and to make recommendations concerning how the United Nations should respond to allegations in the future. This submission to the Review Panel draws on literature regarding children's rights, the nature of child sexual abuse, international instruments and policy, the nature of institutional child sexual abuse, and the CAR case itself. It makes recommendations for reform of UN protocols and procedures to better prevent child sexual abuse, and to improve responses to future occurrences.
Resumo:
Background: Autogenous vein grafting is widely used in regular bypassing procedures. Due to its mismatch with the host artery in both mechanical property and geometry, the graft often over expands under high arterial blood pressure and forms a step-depth where eddy flow develops, thus causing restenosis, fibrous graft wall, etc. External stents, such as sheaths being used to cuff the graft, have been introduced to eliminate these mismatches and increase the patency. Although histological and immunochemical studies have shown some positive effects of the external stent, the mechanical mismatch under the protection of an external stent remains poorly analyzed. Methods: In this study, the jugular veins taken from hypercholesterolemic rabbits were transplanted into the carotid arteries, and non-woven polyglycolic acid (PGA) fabric was used to fabricate the external stents to study the effect of the biodegradable external stent. Eight weeks after the operation, the grafts were harvested to perform mechanical tests and histological examinations. An arc tangent function was suggested to describe the relationship between pressure and cross-sectional area to analyse the compliance of the graft. Results: The results from the mechanical tests indicated that grafts either with or without external stents displayed large compliance in the low-pressure range and were almost inextensible in the high-pressure range. This was very different from the behavior of the arteries or veins in vivo. The data from histological tests showed that, with external stents, collagen fibers were more compact, whilst those in the graft without protection were looser and thicker. No elastic fiber was found in either kind of grafts. Furthermore, grafts without protection were over-expanded which resulted in much bigger cross-sectional areas. Conclusion: The PGA external extent contributes little to the reduction of the mechanical mismatch between the graft and its host artery while remodeling develops. For the geometric mismatch, it reduces the cross-section area, therefore matching with the host artery much better. Although there are some positive effects, conclusively the PGA is not an ideal material for external stent.
Resumo:
Using the dimensional reduction regularization scheme, we show that radiative corrections to the anomaly of the axial current, which is coupled to the gauge field, are absent in a supersymmetric U(1) gauge model for both 't Hooft-Veltman and Bardeen prescriptions for γ5. We also discuss the results with reference to conventional dimensional regularization. This result has significant implications with respect to the renormalizability of supersymmetric models.
Resumo:
Modern drug discovery gives rise to a great number of potential new therapeutic agents, but in some cases the efficient treatment of patient may not be achieved because the delivery of active compounds to the target site is insufficient. Thus, drug delivery is one of the major challenges in current pharmaceutical research. Numerous nanoparticle-based drug carriers, e.g. liposomes, have been developed for enhanced drug delivery and targeting. Drug targeting may enhance the efficiency of the treatment and, importantly, reduce unwanted side effects by decreasing drug distribution to non-target tissues. Liposomes are biocompatible lipid-based carriers that have been studied for drug delivery during the last 40 years. They can be functionalized with targeting ligands and sensing materials for triggered activation. In this study, various external signal-assisted liposomal delivery systems were developed. Signals can be used to modulate drug permeation or release from the liposome formulation, and they provide accurate control of time, place and rate of activation. The study involved three types of signals that were used to trigger drug permeation and release: electricity, heat and light. Electrical stimulus was utilized to enhance the permeation of liposomal DNA across the skin. Liposome/DNA complex-mediated transfections were performed in tight rat epidermal cell model. Various transfection media and current intensities were tested, and transfection efficiency was evaluated non-invasively by monitoring the concentration of secreted reporter protein in cell culture medium. Liposome/DNA complexes produced gene expression, but electrical stimulus did not enhance the transfection efficiency significantly. Heat-sensitive liposomal drug delivery system was developed by coating liposomes with biodegradable and thermosensitive poly(N-(2-hydroxypropyl) methacrylamide-mono/dilactate polymer. Temperature-triggered liposome aggregation and contents release from liposomes were evaluated. The cloud point temperature (CP) of the polymer was set to 42 °C. Polymer-coated liposome aggregation and contents release were observed above CP of the polymer, while non-coated liposomes remained intact. Polymer precipitates above its CP and interacts with liposomal bilayers. It is likely that this induces permeabilization of the liposomal membrane and contents release. Light-sensitivity was introduced to liposomes by incorporation of small (< 5 nm) gold nanoparticles. Hydrophobic and hydrophilic gold nanoparticles were embedded in thermosensitive liposomes, and contents release was investigated upon UV light exposure. UV light-induced lipid phase transitions were examined with small angle X-ray scattering, and light-triggered contents release was shown also in human retinal pigment epithelial cell line. Gold nanoparticles absorb light energy and transfer it into heat, which induces phase transitions in liposomes and triggers the contents release. In conclusion, external signal-activated liposomes offer an advanced platform for numerous applications in drug delivery, particularly in the localized drug delivery. Drug release may be localized to the target site with triggering stimulus that results in better therapeutic response and less adverse effects. Triggering signal and mechanism of activation can be selected according to a specific application.
Resumo:
The system equations of a collisionless, unmagnetized plasma, contained in a box where a high frequency (HF) electric field is incident, are solved in the electrostatic approximation. The surface modes of the plasma in the semi-infinite and box geometry are investigated. In thi high frequency limit, the mode frequencies are not significantly changed by the HF field but their group velocities can be quite different. Two long wavelength low frequency modes, which are not excited in the absence of HF field, are found. These modes are true surface modes (decaying on one wavelength from the surface) unlike the only low frequency ion acoustic mode in the zero field case. In the short wavelength limit the low frequency mode occurs at omega i/ square root 2, omega i being the ion plasma frequency, as a result similar to the case of no HF field.
Resumo:
The paper presents a method for the evaluation of external stability of reinforced soil walls subjected to earthquakes in the framework of the pseudo-dynamic method. The seismic reliability of the wall is evaluated by considering the different possible failure modes such as sliding along the base, overturning about the toe point of the wall, bearing capacity and the eccentricity of the resultant force. The analysis is performed considering properties of the reinforced backfill, foundation soil below the base of the wall, length of the geosynthetic reinforcement and characteristics of earthquake ground motions such as shear wave and primary wave velocity as random variables. The optimum length of reinforcement needed to maintain stability against four modes of failure by targeting various component reliability indices is obtained. Differences between pseudo-static and pseudo-dynamic methods are clearly highlighted in the paper. A complete analysis of pseudo-static and pseudo-dynamic methodologies shows that the pseudodynamic method results in realistic design values for the length of geosynthetic reinforcement under earthquake conditions.
Resumo:
This article considers the merits of alternative policy approaches to management of companies in insolvency administration, in particular from an identity economics theoretical perspective. The use of this perspective provides a novel assessment of the policy alternatives for insolvency administration, which can be characterized as either following the more flexible United States Chapter 11-style debtor-in-possession arrangement, or relying on the appointment of an external administrator or trustee to manage the insolvent company who automatically displaces incumbent management. This analysis indicates that stigma and reputational damage from automatic removal of managers in voluntary administration leaders to "identity loss" and that an insider alternative to the current external administration approach could be a beneficial policy change.
Resumo:
In this chapter, we look at the step beyond reporting, to the external audit or assurance function. The role of any audit engagement is to provide a professional opinion on a set of financial or non-financial assertions reported by an organization's management, based on an agreed evaluative framework. Any such opinion is not a guarantee that the underlying report is free from fraud or misstatement. Where an audit opinion on financial statements is incorrect, this is referred to as an audit failure. Specifically, the textbook definition of audit failure has two components: that the financial statements contain a serious error and that the auditor has failed to detect the error due to the auditor's failure during the audit process.
Resumo:
The system equations of a collisionless, unmagnetized plasma, contained in a box where a high frequency (h.f.1 electric field is incident, are solved in the electrostatic approximation. The surface modes of the plasma in the semi-infinite and box geometry are investigated. In the high frequency limit, the mode frequencies are not significantly changed by the h.f. field but their group velocities can be quite different. Two long wavelength low frequency modes, which are not excited in the absence of h.f. field, are found. These modes are true surface modes (decaying on one wavelength from the surface) unlike the only low frequency ion acoustic mode in the zero field case. In the short wavelength limit the low frequency mode occurs at &/2, oi being the ion plasma frequency, a result similar to the case of no h.f. field.
Resumo:
Crystal structures of six isopropylidene nucleoside derivatives are described. The results show that, under external cyclic constraints, the ribose assumes a variety of unusual conformations. In those compounds which possess a base-to-sugar cyclization through the C(4′) atom, the furanose pucker is predominantly C(4′)-endo, O(4′)-exo. The possible relevance of the sulphur geometry in two of the compounds to certain structural aspects of the action of the enzyme thymidylate synthetase is also pointed out.
Resumo:
Large numbers of Sagmariasus verreauxi are trapped and hand collected in Australia, but discarded due to size and quota restrictions, and under the unevaluated assumption of few impacts. To test the validity of enforced discarding, trapped and hand-collected S. verreauxi (49-143. mm carapace length - CL) were examined for external damage, placed into cages, transferred to aquaria and monitored (with controls) over three months. Haemolymph was non-repetitively sampled immediately and at one, three, and seven days to quantify stress. Most trapped (64%) and hand-collected (79%) specimens were undersized (<104. mm CL), with the latter method yielding broader ranges of sizes and moult stages. Within-trap Octopus tetricus predation caused the only mortalities (3.3%). Hand collection resulted in much greater antennae and pereopod loss than trapping (53 vs. 4%) but, compared to controls, both methods evoked benign physiological responses that resolved within a week. While most wounded S. verreauxi regenerated all or some missing appendages post-moult, their mean CLs were less than those from intact conspecifics. Simple strategies, including larger mesh sizes, and/or installing modifications to reduce bycatch in traps, careful hand collection, and appropriate release techniques might minimise impacts (including predation) to unwanted S. verreauxi, and help to control stock exploitation. © 2012 Elsevier B.V.
Resumo:
The breakdown of the usual method of Fourier transforms in the problem of an external line crack in a thin infinite elastic plate is discovered and the correct solution of this problem is derived using the concept of a generalised Fourier transform of a type discussed first by Golecki [1] in connection with Flamant's problem.
Resumo:
BACKGROUND Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP. OBJECTIVE The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP. METHODS Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials. RESULTS All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials. LIMITATIONS This PA protocol consisted of controlled activity trials. CONCLUSIONS Accelerometers provide valid and reliable measures of PA intensity among youth with CP.
Resumo:
Aim This study evaluated the validity of the OMNI Walk/Run Rating of Perceived Exertion (OMNI-RPE) scores with heart rate and oxygen consumption (VO2) for children and adolescents with cerebral palsy (CP). Method Children and adolescents with CP, aged 6 to 18 years and Gross Motor Function Classification System (GMFCS) levels I to III completed a physical activity protocol with seven trials ranging in intensity from sedentary to moderate-to-vigorous. VO2 and heart rate were recorded during the physical activity trials using a portable indirect calorimeter and heart rate monitor. Participants reported OMNI-RPE scores for each trial. Concurrent validity was assessed by calculating the average within-subject correlation between OMNI-RPE ratings and the two physiological indices. Results For the correlational analyses, 48 participants (22 males, 26 females; age 12y 6mo, SD 3y 4mo) had valid bivariate data for VO2 and OMNI-RPE, while 40 participants (21 males, 19 females; age 12y 5mo, SD 2y 9mo) had valid bivariate data for heart rate and OMNI-RPE. VO2 (r=0.80; 95% CI 0.66–0.88) and heart rate (r=0.83; 95% CI 0.70–0.91) were moderately to highly correlated to OMNI-RPE scores. No difference was found for the correlation of physiological data and OMNI-RPE scores across the three GMFCS levels. The OMNI-RPE scores increased significantly in a dose-response manner (F6,258=116.1, p<0.001) as exercise intensity increased from sedentary to moderate-to-vigorous. Interpretation OMNI-RPE is a clinically feasible option to monitor exercise intensity in ambulatory children and adolescents with CP.
Resumo:
BACKGROUND Sedentary behavior is continuing to emerge as an important target for health promotion. The purpose of this study was to determine the validity of a self-report use of time recall tool, the Multimedia Activity Recall for Children and Adults (MARCA) in estimating time spent sitting/lying, compared with a device-based measure. METHODS Fifty-eight participants (48% female, [mean±standard deviation] 28±7.4 years of age, 23.9±3.05 kg/m2) wore an activPAL device for 24-h and the following day completed the MARCA. Pearson correlation coefficients (r) were used to analyse convergent validity of the adult MARCA compared with activPAL estimates of total sitting/lying time. Agreement was examined using Bland-Altman plots. RESULTS According to activPAL estimates, participants spent 10.4 hr/day [standard deviation (SD)=2.06] sitting or lying down while awake. The correlation between MARCA and activPAL estimates of total sit/lie time was r=0.77 (95% confidence interval = 0.64-0.86; p<0.001). Bland-Altman analyses revealed a mean bias of +0.59 hr/day with moderately wide limits of agreement (-2.35 hours to +3.53 hr/day). CONCLUSIONS This study found a moderate to strong agreement between the adult MARCA and the activPAL, suggesting that the MARCA is an appropriate tool for the measurement of time spent sitting or lying down in an adult population.