896 resultados para external cooling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to determine physiological stress markers, neutrophil:lymphocyte ratio (N/L) and corticoid concentrations, in gestating sows under different cooling systems. A sprinkling cooling system (SS) and a system based on fan-assisted evaporative cellulose pad (PS) were used. SS showed higher N/L ratio (1.095) than PS (0.850). Corticoid concentrations showed high variability. Corticosteroids are more efficient short-term stress indicators while N/L ratio is a good medium and long-term stress indicator. According to N/L ratio, gestating sows under PS benefit from a higher level of welfare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied sidebranching induced by fluctuations in dendritic growth. The amplitude of sidebranching induced by internal (equilibrium) concentration fluctuations in the case of solidification with solutal diffusion is computed. This amplitude turns out to be significantly smaller than values reported in previous experiments. The effects of other possible sources of fluctuations (of an external origin) are examined by introducing nonconserved noise in a phase-field model. This reproduces the characteristics of sidebranching found in experiments. Results also show that sidebranching induced by external noise is qualitatively similar to that of internal noise, and it is only distinguished by its amplitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the aim of understanding the mechanisms that control the metamorphic transition from the CH4- to the H2O-(CO2)-dominated fluid zone in the Helvetic domain of the Central Alps of Switzerland, fluid inclusions in quartz, illite ``crystallinity'' index, vitrinite reflectance, and the stable isotope compositions of vein and whole rock minerals and fluids trapped in quartz were investigated along four cross-sections. Increasing temperature during prograde metamorphism led to the formation of dry gas by hydrocarbon cracking in the CH4-zone. Fluid immiscibility in the H2O-CH4-(CO2)-NaCl system resulted in cogenetic, CH4- and H2O-dominated fluid inclusions. In the CH4-zone, fluids were trapped at temperatures <= 270 +/- 5 degrees C. The end of the CH4-zone is markedby a sudden increase of CO2 content in the gas phase of fluid inclusions. At temperatures > 270 +/- 5 degrees C, in the H2O-zone, the total amount of volatiles within the fluid decreased below 1 mol% with no immiscibility. This resulted m total homogenization temperatures of H2O-(CO2-CH4)-NaCl inclusions below 180 degrees C. Hydrogen isotope compositions of methane in fluid inclusion have delta D values of less than -100 parts per thousand in the CH4-zone, typical for an origin through cracking of higher hydrocarbons, but where the methane has not equilibrated with the pore water. delta D values of fluid inclusion water are around -40 parts per thousand., in isotopic equilibrium with phyllosilicates of the whole rocks. Within the CH4 to H2O(CO2) transition zone, delta D(H2O) values in fluid inclusions decrease to -130 parts per thousand interpreted to reflect the contribution of deuterium depleted water from methane oxidation. In the H2O-zone, delta D(H2O) values increase again towards an average of -30 parts per thousand which is again consistent with isotopic equilibrium with host-rock phyllosilicates. delta C-13 values of methane in fluid inclusions from the CH4-zone are around -27 parts per thousand in isotopic equilibrium with calcite in veins and whole rocks. The delta C-13(CH4) values decrease to less than -35 parts per thousand at the transition to the H2O-zone and are no longer in equilibrium with the carbonates in the whole rocks. delta C-13 values of CO, are variable but too low to be in equilibrium with the wall rock fluids, compatible with a contribution of CO2 from closed system oxidation of methane. Differences in isotopic composition between host-rock and Alpine fissure carbonate are generally small, suggesting that the amount of CO2 produced by oxidation of methane was small compared to the C-budget in the rocks and local pore fluids were buffered by the wall rocks during precipitation of calcite within the fissures. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the most comprehensive comparison to date of the predictive benefit of genetics in addition to currently used clinical variables, using genotype data for 33 single-nucleotide polymorphisms (SNPs) in 1,547 Caucasian men from the placebo arm of the REduction by DUtasteride of prostate Cancer Events (REDUCE®) trial. Moreover, we conducted a detailed comparison of three techniques for incorporating genetics into clinical risk prediction. The first method was a standard logistic regression model, which included separate terms for the clinical covariates and for each of the genetic markers. This approach ignores a substantial amount of external information concerning effect sizes for these Genome Wide Association Study (GWAS)-replicated SNPs. The second and third methods investigated two possible approaches to incorporating meta-analysed external SNP effect estimates - one via a weighted PCa 'risk' score based solely on the meta analysis estimates, and the other incorporating both the current and prior data via informative priors in a Bayesian logistic regression model. All methods demonstrated a slight improvement in predictive performance upon incorporation of genetics. The two methods that incorporated external information showed the greatest receiver-operating-characteristic AUCs increase from 0.61 to 0.64. The value of our methods comparison is likely to lie in observations of performance similarities, rather than difference, between three approaches of very different resource requirements. The two methods that included external information performed best, but only marginally despite substantial differences in complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most organisms use circadian oscillators to coordinate physiological and developmental processes such as growth with predictable daily environmental changes like sunrise and sunset. The importance of such coordination is highlighted by studies showing that circadian dysfunction causes reduced fitness in bacteria and plants, as well as sleep and psychological disorders in humans. Plant cell growth requires energy and water-factors that oscillate owing to diurnal environmental changes. Indeed, two important factors controlling stem growth are the internal circadian oscillator and external light levels. However, most circadian studies have been performed in constant conditions, precluding mechanistic study of interactions between the clock and diurnal variation in the environment. Studies of stem elongation in diurnal conditions have revealed complex growth patterns, but no mechanism has been described. Here we show that the growth phase of Arabidopsis seedlings in diurnal light conditions is shifted 8-12 h relative to plants in continuous light, and we describe a mechanism underlying this environmental response. We find that the clock regulates transcript levels of two basic helix-loop-helix genes, phytochrome-interacting factor 4 (PIF4) and PIF5, whereas light regulates their protein abundance. These genes function as positive growth regulators; the coincidence of high transcript levels (by the clock) and protein accumulation (in the dark) allows them to promote plant growth at the end of the night. Thus, these two genes integrate clock and light signalling, and their coordinated regulation explains the observed diurnal growth rhythms. This interaction may serve as a paradigm for understanding how endogenous and environmental signals cooperate to control other processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peer-reviewed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rotational speed of high-speed electric machines is over 15 000 rpm. These machines are compact in size when compared to the power rate. As a consequence, the heat fluxes are at a high level and the adequacy of cooling becomes an important design criterion. In the high-speed machines, the air gap between the stator and rotor is a narrow flow channel. The cooling air is produced with a fan and the flow is then directed to the air gap. The flow in the gap does not provide sufficient cooling for the stator end windings, and therefore additional cooling is required. This study investigates the heat transfer and flow fields around the coil end windings when cooling jets are used. As a result, an innovative and new assembly is introduced for the cooling jets, with the benefits of a reduced amount of hot spots, a lower pressure drop, and hence a lower power need for the cooling fan. The gained information can also be applied to improve the cooling of electric machines through geometry modifications. The objective of the research is to determine the locations of the hot spots and to find out induced pressure losses with different jet alternatives. Several possibilities to arrange the extra cooling are considered. In the suggested approach cooling is provided by using a row of air jets. The air jets have three main tasks: to cool the coils effectively by direct impingement jets, to increase and cool down the flow that enters the coil end space through the air gap, and to ensure the correct distribution of the flow by forming an air curtain with additional jets. One important aim of this study is the arrangement of cooling jets in such manner that hot spots can be avoided to wide extent. This enables higher power density in high-speed motors. This cooling system can also be applied to the ordinary electric machines when efficient cooling is needed. The numerical calculations have been performed using a commercial Computational Fluid Dynamics software. Two geometries have been generated: cylindrical for the studied machine and Cartesian for the experimental model. The main parameters include the positions, arrangements and number of jets, the jet diameters, and the jet velocities. The investigated cases have been tested with two widely used turbulence models and using a computational grid of over 500 000 cells. The experimental tests have been made by using a simplified model for the end winding space with cooling jets. In the experiments, an emphasis has been given to flow visualisation. The computational analysis shows good agreement with the experimental results. Modelling of the cooling jet arrangement enables also a better understanding of the complex system of heat transfer at end winding space.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Existing VADs are single-ventricle pumps needing anticoagulation. We developed a bi ventricular external assist device that reproduces the physiological heart muscle movement completely avoiding anticoagulants. Methods: The device has a carbon fibre skeleton fitting a 30-40 kg patient's heart, to which a Nitinol based artificial muscle is connected. The artificial muscle wraps both ventricles. The strength of the Nitinol fibres is amplified by a pivot articulation in contact with the ventricle wall. The fibres are electrically driven and a dedicated control unit has been developed. We assessed hemodynamic performances of this device using a previously described dedicated bench test. Volume ejected and pressure gradient has been measured with afterload ranging from 25 to 50mmHg. Results: With anafterload of 50mmHg the system has an ejection fraction (EF) of 10% on the right side and 8% on the left side. The system is able to generate a systolic ejection of 5,5 ml on the right side and 4,4 ml on the left side. With anafterload of 25mmHg the results are reduced of about 20%. The activation frequency is 80/minute resulting in a total volume displacement of 440 ml/minute on the right side and 352 ml/minute on the left side. Conclusions: The artificial muscle follows Starling's law as the ejected volume increases when afterload increases. These preliminary studies confirmed the possibility of improving the EF of a failing heart using artificial muscle for external cardiac compression. This device could be helpful in weaning CPB and/or for short-term cardio-circulatory support in paediatric population with cardiac failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The saphenous vein is the conduit of choice in bypass graft procedures. Haemodynamic factors play a major role in the development of intimal hyperplasia (IH), and subsequent bypass failure. To evaluate the potential protective effect of external reinforcement on such a failure, we developed an ex vivo model for the perfusion of segments of human saphenous veins under arterial shear stress. In veins submitted to pulsatile high pressure (mean pressure at 100 mmHg) for 3 or 7 days, the use of an external macroporous polyester mesh 1) prevented the dilatation of the vessel, 2) decreased the development of IH, 3) reduced the apoptosis of smooth muscle cells, and the subsequent fibrosis of the media layer, 4) prevented the remodelling of extracellular matrix through the up-regulation of matrix metalloproteinases (MMP-2, MMP-9) and plasminogen activator type I. The data show that, in an experimental ex vivo setting, an external scaffold decreases IH and maintains the integrity of veins exposed to arterial pressure, via increase in shear stress and decrease wall tension, that likely contribute to trigger selective molecular and cellular changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A case of sustained combustion of a human body that occurred in 2006 in Geneva, Switzerland, is presented. The body of a man was discovered at home and found to have been almost completely incinerated between the knees and the mid-chest, with less damage to the head, arms, lower legs and feet. His dog was also found dead just behind the house door. The external source of ignition was most likely a cigarette or a cigar. The chair in which the man had been sitting was largely consumed while other objects in the room exhibited only a brown oily or greasy coating and were virtually undamaged. Toxicological analyses carried out on the blood from the lower legs showed low levels of desalkylflurazepam. Alcohol concentration was 1.10 per thousand, carboxyhaemoglobin levels were 12% and cyanide concentration was 0.05 mg/L. Toxicological analyses carried out on the dog's blood showed carboxyhaemoglobin levels at 65%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: A study was made to determine the temperature increment at the dental root surface following Er,Cr:YSGG laser irradiation of the root canal. Design. Human canines and incisors previously instrumented to K file number ISO 30 were used. Irradiation was carried out with glass fiber endodontic tips measuring 200 μm in diameter and especially designed for insertion in the root canal. The teeth were irradiated at 1 and 2 W for 30 seconds, without water spraying or air, and applying a continuous circular movement (approximately 2 mm/sec.) in the apico-coronal direction. Results: At the 1 W power setting, the mean temperature increment was 3.84ºC versus 5.01ºC at 2 W. In all cases the difference in mean value obtained after irradiation versus the mean baseline temperature proved statistically significant (p< 0.05). Conclusions: Application of the Er,Cr:YSGG laser gives rise to a statistically significant temperature increment at the external root surface, though this increment is probably clinically irrelevant, since it would appear to damage the tissues (periodontal ligament and alveolar bone) in proximity to the treated tooth

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The ASTRAL score was recently introduced as a prognostic tool for acute ischemic stroke. It predicts 3-month outcome reliably in both the derivation and the validation European cohorts. We aimed to validate the ASTRAL score in a Chinese stroke population and moreover to explore its prognostic value to predict 12-month outcome. METHODS: We applied the ASTRAL score to acute ischemic stroke patients admitted to 132 study sites of the China National Stroke Registry. Unfavorable outcome was assessed as a modified Rankin Scale score >2 at 3 and 12 months. Areas under the curve were calculated to quantify the prognostic value. Calibration was assessed by comparing predicted and observed probability of unfavorable outcome using Pearson correlation coefficient. RESULTS: Among 3755 patients, 1473 (39.7%) had 3-month unfavorable outcome. Areas under the curve for 3 and 12 months were 0.82 and 0.81, respectively. There was high correlation between observed and expected probability of unfavorable 3- and 12-month outcome (Pearson correlation coefficient: 0.964 and 0.963, respectively). CONCLUSIONS: ASTRAL score is a reliable tool to predict unfavorable outcome at 3 and 12 months after acute ischemic stroke in the Chinese population. It is a useful tool that can be readily applied in clinical practice to risk-stratify acute stroke patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Therapeutic hypothermia following hypoxic ischaemic encephalopathy in term infants was introduced into Switzerland in 2005. Initial documentation of perinatal and resuscitation details was poor and neuromonitoring insufficient. In 2011, a National Asphyxia and Cooling Register was introduced. AIMS: To compare management of cooled infants before and after introduction of the register concerning documentation, neuromonitoring, cooling methods and evaluation of temperature variability between cooling methods. STUDY DESIGN: Data of cooled infants before the register was in place (first time period: 2005-2010) and afterwards (second time period: 2011-2012) was collected with a case report form. RESULTS: 150 infants were cooled during the first time period and 97 during the second time period. Most infants were cooled passively or passively with gel packs during both time periods (82% in 2005-2010 vs 70% in 2011-2012), however more infants were cooled actively during the second time period (18% versus 30%). Overall there was a significant reduction in temperature variability (p < 0.001) comparing the two time periods. A significantly higher proportion of temperature measurements within target temperature range (72% versus 77%, p < 0.001), fewer temperature measurements above (24% versus 7%, p < 0.001) and more temperatures below target range (4% versus 16%, p < 0.001) were recorded during the second time period. Neuromonitoring improved after introduction of the cooling register. CONCLUSION: Management of infants with HIE improved since introducing the register. Temperature variability was reduced, more temperature measurements in the target range and fewer temperature measurements above target range were observed. Neuromonitoring has improved, however imaging should be performed more often.