993 resultados para electrochemical corrosion


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Parameters extracted from the wire beam electrode (WBE) galvanic current maps have been used in conjunction with electrochemical noise patterns to directly quantify the degree of localised corrosion inhibition provided by inhibitors and to understand the mechanism of localised corrosion inhibition. The behaviour of two traditional localised corrosion inhibitors has been assessed by their effects on the maximum anodic current density (imax), total anodic current density (itot), the number of anodic sites (Na) and the localised corrosion intensity index (LCII). Typical experiments are presented to illustrate the application of these parameters in providing useful information on the efficiency and mechanism of localised corrosion inhibition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on the corrosion of Mg alloy AZ31 in simulated body fluid (SBF) using static immersion tests and electrochemical impedance spectroscopy. A preliminary study on the effect of flowing SBF on the corrosion behaviour of AZ31 has also been carried out. Low toxicity ionic liquids (ILs) trimethyl(butyl)phosphonium diphenyl phosphate P1444DPP and trihexyl(tetradecyl)-phosphonium bis-2,4,4trimethylpentyl-phosphinate [P66614][ i(C8) 2PO2] have been used to provide corrosion protection for AZ31 in SBF. Time dependent immersion tests indicate that under static conditions, AZ31 suffers severe localised corrosion in SBF, with pits developing predominantly beside the Al-Mn intermetallic phase in the α matrix. At longer immersion times, the corrosion product eventually precipitates and covers the entire specimen surface. When exposed to SBF under flowing conditions with a shear stress of 0·88 Pa, more uniform corrosion was observed. The optical profilometry results and electrochemical impedance spectroscopy analysis suggest that both P
1444DPP and [P66614][i(C8)2PO2] pretreatments can increase the corrosion resistance of AZ31 in SBF, in particular by decreasing the number of deeper pits found on the alloy surface. Cytotoxic test shows that the presence of the ILs P
1444DPP and [P66614][i(C8)2PO2] in cell culture media slightly inhibits the growth of human coronary artery endothelial cells in comparison with the good cell viability around the treated specimen. A pretreatment with IL is used in order to improve the corrosion resistance of this alloy in SBF. © 2012 Institute of Materials, Minerals and Mining.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The microstructures, mechanical properties, corrosion behaviour and biocompatibility of the Mg-Zr-Ca alloys have been investigated for potential use in orthopaedic applications. The microstructures of the alloys were examined using X-ray diffraction analysis, optical microscopy and scanning electron microscopy. The mechanical properties of Mg-Zr-Ca alloys were determined from compressive tests. The corrosion behaviour has been investigated using an immersion test and electrochemical measurement. The biocompatibility was evaluated by cell growth factor using osteoblast-like SaOS2 cell. The experimental results indicate that the hot-rolled Mg-Zr-Ca alloys exhibit much finer microstructures than the as-cast Mg-Zr-Ca alloys which show coarse microstructures. The compressive strength of the hot-rolled alloys is much higher than that of the as-cast alloys and the human bone, which would offer appropriate mechanical properties for orthopaedic applications. The corrosion resistance of the alloys can be enhanced significantly by hot-rolling process. Hot-rolled Mg-0.5Zr-1Ca alloy (wt %) exhibits the lowest corrosion rate among all alloys studied in this paper. The hot-rolled Mg-0.5Zr-1Ca and Mg-1Zr-1Ca alloys exhibit better biocompatibility than other studied alloys and possess advanced mechanical properties, corrosion resistance and biocompatibility, suggesting that they have a great potential to be good candidates for orthopaedic applications. © 2012 Springer Science+Business Media New York.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AA5083 aluminium alloy has been shown to be partially passivated by a 2-step anodic pre-treatment in Trihexyl(tetradecyl)phosphonium bis(trifluoromethylsulfonyl)amide ([P6,6,6,14][NTf2]) ionic liquid. Surface characterisation revealed that an electrochemical etching process had occurred, comparable to acid etching of aluminium. Scanning electron microscopy/energy dispersive x-ray spectroscopy results have established that magnesium dealloyed from the Mg2Si intermetallic particles and metal fluorides were deposited onto the remaining Mg2Si sites, which subsequently led to decreased anodic corrosion kinetics (to one third of the control) as well as an increase in the corrosion and pitting potentials. This unique electrochemical etching process offers a simple and quick method to improve the corrosion resistance of an aluminium alloy as it leads to a more uniform surface, in terms of defect size and distribution, compared to conventional acid etching. This process has the potential to be used as a pre-treatment to inhibit corrosion of AA5083 alloy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the introduction of inhibitors to the oil and gas industry in the 1940’s, corrosion inhibition has played a key role in carbon dioxide (CO2) corrosion control. Major inhibitor discoveries occurred from the late 1940's to the late 1960's, followed by the refinement of formulations and the development of improved application methods. Over the past two to three decades, although some new derivatives of existing inhibitors such as amide, amine and imidazoline have been reported, there have been few if any discoveries of new CO2 corrosion inhibitors. In recent years, the development of environmentally friendly inhibitors and the inhibition of localised corrosion have become driving forces behind new advances in corrosion inhibitor technology. Recently a rare earth metal organic compound, lanthanum 4-hydroxy cinnamate has been found to be an efficient corrosion inhibitor for mild steel in CO2 containing aqueous media. A resorcinarene acid has been found to provide effective localised corrosion inhibition by promoting a random distribution of insignificant anodic currents. The advent of advanced scanning probe techniques and an electrochemical integrated multi-electrode array have facilitated the discovery of corrosion inhibitors. This paper provides a brief overview of recent progress in this field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, the use of magnesium alloys as metallic implant materials for biodegradable coronary artery stents has been steadily growing in interest. However, AZ31 magnesium alloys present poor corrosion resistance in the body environment. This work reports on the use of a treatment with low-toxicity IL Trimethyl (butyl) phosphonium diphenyl phosphate P1444DPP, which provides corrosion protection for magnesium alloy AZ31 in simulated body fluid (SBF). Before IL treatment, surface was cleaned by HNO3 and H3PO4 acid pickling solution. The effect of ionic liquid treatment on the corrosion performance of magnesium alloys AZ31in simulated body fluid has been investigated by electrochemical tests and the observation of surface morphology. The results show that this IL treatment succeeded in increasing the corrosion resistance of AZ31 when exposed to SBF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The idea of bioabsorbable/biocorrodible stents has gained increasing attention in the last decade. Permanent coronary stents, traditionally made from 316L grade stainless steel, are routinely used for the treatment of blocked arteries. However, these stents can cause complications such as restenosis, thrombosis and the need for the patient to undergo prolonged antiplatelet therapy. Biodegradable metal stents provide an opportunity for the stent to remain in place for a period to ensure restoration of function and then degrade through a carefully controlled bio-corrosion process. Among the number of potentially suitable materials, Magnesium alloys have shown great promise as a stent material due to their non-toxicity [1] and the corrosion rates attainable in biological environments. However, a carefully controlled corrosion process is essential in order to avoid hyper hydrogen generation and the fatal consequences that follow. In addition uniform corrosion is a basic requirement to maintain the mechanical integrity and load bearing characteristics. Work being undertaken in our laboratories focuses on controlling the corrosion behaviour of magnesium in a simulated biological environment in the presence of protein. In the investigation reported here the Mg alloy has been examined using Scanning Electrochemical Microscope (SECM) to visualize the corrosion process and identify the corrosion pattern. Complementary bulk electrochemical techniques (EIS and potentiodynamic polarization) have been used to acquire kinetic and mechanistic information. Early results obtained by SECM have revealed the tendency towards pitting corrosion in the early stages which subsequently develops in to filiform corrosion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The corrosion behaviour of nanocrystalline and microcrystalline Fe20Cr alloys, prepared by high energy ball milling followed by compaction and sintering, was studied in 0.05M H2SO4 and 0.05M H2SO4 + 0.5M NaCl by potentiodynamic polarization. The nanocrystalline alloy exhibited improved passivating ability and pitting resistance as described by passivation potential, critical current density, passive current density and breakdown potential. XPS and SIMS analysis revealed greater Cr content in the passive film formed on the nanocrystalline form of the alloy. The enhanced passivating ability of the nanocrystalline alloy was attributed to the formation of the passive film with higher Cr content.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditional researches on metal corrosion under salt solutions deposit conditions are usually carried out by visual, electron microscopic observations and simple electrochemical measurement via a traditional one-piece electrode. These techniques have difficulties in measuring localized corrosion that frequently occur in inhomogeneous media. This paper reports the results from the experiments using specially shaped coupons and a relatively new method of measuring heterogeneous electrochemical processes, namely, the wire beam electrode(WBE). Preliminary results from copper and aluminum corrosion in highly concentrated sodium chloride solutions with and without solid deposits show that the method is useful in simulating and studying corrosion especially localized corrosion in pipelines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a brief review of major techniques applied in carbon dioxide corrosion testing and monitoring. The focus is on the advantages and disadvantages of variously designed testing apparatus and monitoring devices for localized corrosion detection and assessment. Critical factors affecting the reliability and accuracy of major corrosion testing techniques are briefly discussed. It is concluded that major reasons that lead to reporting of inaccurate corrosion rates and patterns include: (i) limitations in conventional electrochemical and nonelectrochemical methods for localized corrosion measurements, and difficulties in data interpretation; (ii) challenges in simulating localized corrosion mechanisms and their changes with the extension of corrosion testing. Underdeposit corrosion testing is presented as a case to illustrate challenges in simulating localized corrosion processes and mechanisms. Experiment data have been presented to show potential difficulties of the artificial pit electrode method in evaluating underdeposit corrosion and its inhibitors. The wire beam electrode method has been used to study underdeposit corrosion with and without inhibitor present. Several interesting corrosion mechanisms have been revealed at different stages of underdeposit corrosion processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The corrosion of steel grinding balls is a major recurrent cost for mill operators concerned with the production gold. Subsequently, the use of corrosion inhibitors in production fluids, which is typically at pH >9, is an attractive and economical option. This study reports on the corrosion wear of steel grinding balls under alkaline/oxygen conditions and in presence of cyanide. A fundamental study on the influence of several inorganic-based inhibitors (i.e., nitrite, chromate, silicate, hexametaphosphate) on the corrosion rate of carbon steel was undertaken. Subsequently, the corrosion performances of various inhibitors were evaluated in stirred vessels. Corrosion rates were determined via mass loss and electrochemical methods (i.e., linear polarisation, Tafel). It was observed that inhibitors based upon chromate provide superior protection under the conditions investigated in this study. In lime treated, high chloride waters, chromate gave over 80% protection at levels of 10 100 ppm with no evidence of pitting.