938 resultados para electro-olfactogram


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, an Atomic Force Microscopy (AFM) roughness analysis was performed on non-commercial Nitinol alloys with Electropolished (EP) and Magneto-Electropolished (MEP) surface treatments and commercially available stents by measuring Root-Mean-Square (RMS) , Average Roughness (Ra), and Surface Area (SA) values at various dimensional areas on the alloy surfaces, ranging from (800 x 800 nm) to (115 x 115µm), and (800 x 800 nm) to (40 x 40 µm) on the commercial stents. Results showed that NiTi-Ta 10 wt% with an EP surface treatment yielded the highest overall roughness, while the NiTi-Cu 10 wt% alloy had the lowest roughness when analyzed over (115 x 115 µm). Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) analysis revealed unique surface morphologies for surface treated alloys, as well as an aggregation of ternary elements Cr and Cu at grain boundaries in MEP and EP surface treated alloys, and non-surface treated alloys. Such surface micro-patterning on ternary Nitinol alloys could increase cellular adhesion and accelerate surface endothelialization of endovascular stents, thus reducing the likelihood of in-stent restenosis and provide insight into hemodynamic flow regimes and the corrosion behavior of an implantable device influenced from such surface micro-patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microstructure manipulation is a fundamental process to the study of biology and medicine, as well as to advance micro- and nano-system applications. Manipulation of microstructures has been achieved through various microgripper devices developed recently, which lead to advances in micromachine assembly, and single cell manipulation, among others. Only two kinds of integrated feedback have been demonstrated so far, force sensing and optical binary feedback. As a result, the physical, mechanical, optical, and chemical information about the microstructure under study must be extracted from macroscopic instrumentation, such as confocal fluorescence microscopy and Raman spectroscopy. In this research work, novel Micro-Opto-Electro-Mechanical-System (MOEMS) microgrippers are presented. These devices utilize flexible optical waveguides as gripping arms, which provide the physical means for grasping a microobject, while simultaneously enabling light to be delivered and collected. This unique capability allows extensive optical characterization of the structure being held such as transmission, reflection, or fluorescence. The microgrippers require external actuation which was accomplished by two methods: initially with a micrometer screw, and later with a piezoelectric actuator. Thanks to a novel actuation mechanism, the “fishbone”, the gripping facets remain parallel within 1 degree. The design, simulation, fabrication, and characterization are systematically presented. The devices mechanical operation was verified by means of 3D finite element analysis simulations. Also, the optical performance and losses were simulated by the 3D-to-2D effective index (finite difference time domain FDTD) method as well as 3D Beam Propagation Method (3D-BPM). The microgrippers were designed to manipulate structures from submicron dimensions up to approximately 100 µm. The devices were implemented in SU-8 due to its suitable optical and mechanical properties. This work demonstrates two practical applications: the manipulation of single SKOV-3 human ovarian carcinoma cells, and the detection and identification of microparts tagged with a fluorescent “barcode” implemented with quantum dots. The novel devices presented open up new possibilities in the field of micromanipulation at the microscale, scalable to the nano-domain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct alcohol fuel cells (DAFCs) mostly use low molecular weight alcohols such as methanol and ethanol as fuels. However, short-chain alcohol molecules have a relative high membrane crossover rate in DAFCs and a low energy density. Long chain alcohols such as butanol have a higher energy density, as well as a lower membrane crossover rate compared to methanol and ethanol. Although a significant number of studies have been dedicated to low molecular weight alcohols in DAFCs, very few studies are available for longer chain alcohols such as butanol. A significant development in the production of biobutanol and its proposed application as an alternative fuel to gasoline in the past decade makes butanol an interesting candidate fuel for fuel cells. Different butanol isomers were compared in this study on various Pt and PtSn bimetallic catalysts for their electro-oxidation activities in acidic media. Clear distinctive behaviors were observed for each of the different butanol isomers using cyclic voltammetry (CV), indicating a difference in activity and the mechanism of oxidation. The voltammograms of both n-butanol and iso-butanol showed similar characteristic features, indicating a similar reaction mechanism, whereas 2-butanol showed completely different features; for example, it did not show any indication of poisoning. Ter-butanol was found to be inactive for oxidation on Pt. In situ FTIR and CV analysis showed that OHads was essential for the oxidation of primary butanol isomers which only forms at high potentials on Pt. In order to enhance the water oxidation and produce OHads at lower potentials, Pt was modified by the oxophilic metal Sn and the bimetallic PtSn was studied for the oxidation of butanol isomers. A significant enhancement in the oxidation of the 1° butanol isomers was observed on addition of Sn to the Pt, resulting in an oxidation peak at a potential ∼520 mV lower than that found on pure Pt. The higher activity of PtSn was attributed to the bifunctional mechanism on PtSn catalyst. The positive influence of Sn was also confirmed in the PtSn nanoparticle catalyst prepared by the modification of commercial Pt/C nanoparticle and a higher activity was observed for PtSn (3:1) composition. The temperature-dependent data showed that the activation energy for butanol oxidation reaction over PtSn/C is lower than that over Pt/C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improvements to the current state of the art in microfabricated cantilevers are investigated in order to realize enhanced functionality and increased versatility for use in ultrafast electrophoretic molecular sorting and delivery. Design rationale and fabrication process flow are described for six types of electro-thermal microcantilevers. Devices have been tailored for the process of separating mixtures of heterogeneous molecules into discrete detectable bands based on electrophoretic mobility, and delivering them to a conductive substrate using electric fields. Four device types include integrated heating elements capable of warming samples to catalyze reactions or cleaning the device for reuse. Similar devices have been shown to be capable of targeting temperatures between ambient conditions and the melting point of silicon, to within 0.1˚C precision or better. All microcantilevers types are equipped with a highly doped conductive silicon tip capable of interacting with a conductive substrate to deliver molecules under the presence of an electric field. Devices are equipped with additional electrodes to aid in sorting molecules on the surface of the probe end. Two designs contain two legs and one additional sorting electrode while four designs contain three legs and have two sorting electrodes. Devices having two sorting electrodes are designed to be capable of sorting three or more molecular species, a distinctive advancement in the state of the art. A detailed process flow of the fabrication process for all six electro-thermal cantilever designs are explained in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oceans environmental monitoring and seafloor exploitation need in situ sensors and optical devices (cameras, lights) in various locations and on various carriers in order to initiate and to calibrate environmental models or to operate underwater industrial process supervision. For more than 10 years Ifremer deploys in situ monitoring systems for various seawater parameters and in situ observation systems based on lights and HD Cameras. To be economically operational, these systems must be equipped with a biofouling protection dedicated to the sensors and optical devices used in situ. Indeed, biofouling, in less than 15 days [1] will modify the transducing interfaces of the sensors and causes unacceptable bias on the measurements provided by the in situ monitoring system. In the same way biofouling will decrease the optical properties of windows and thus altering the lighting and the quality fot he images recorded by the camera.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generalidades anatómicas del musculo cardíaco -- Miocardio ventricular -- Génesis de la actividad -- eléctrica del corazón -- Señal eléctrica del corazón -- Representación vectorial -- El electrocardiograma --Intervalos y segmentos del electrocardiograma --Formas estándares de medición en el electrocardiograma -- Derivaciones bipolares -- Derivaciones monopolares --Posicionamiento adecuado de los electrodos-- Etapa de amplificación, filtrado y adaptación --Circuito de adecuación de la señal – Microcomputadora --Touchscreen display -- Shiel SD -- RTC (Real Time Clock) -- Thermal printer arduino -- Análisis de redes e interpretación del circuito de prueba -- Descripción, condiciones y resultados de la experimentación -- Desarrollo del dispositivo -- Interfaz de usuario -- Sistema de digitalización -- Sistema de Almacenamiento

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to simulate and optically characterize the piezoelectric performance of complementary metal oxide semiconductor (CMOS) compatible microcantilevers based on aluminium nitride (AlN) and manufactured at room temperature. This study should facilitate the integration of piezoelectric micro-electro-mechanical systems (MEMS) such as microcantilevers, in CMOS technology. Besides compatibility with standard integrated circuit manufacturing procedures, low temperature processing also translates into higher throughput and, as a consequence, lower manufacturing costs. Thus, the use of the piezoelectric properties of AlN manufactured by reactive sputtering at room temperature is an important step towards the integration of this type of devices within future CMOS technology standards. To assess the reliability of our fabrication process, we have manufactured arrays of free-standing microcantilever beams of variable dimension and studied their piezoelectric performance. The characterization of the first out-of-plane modes of AlN-actuated piezoelectric microcantilevers has been carried out using two optical techniques: laser Doppler vibrometry (LDV) and white light interferometry (WLI). In order to actuate the cantilevers, a periodic chirp signal in certain frequency ranges was applied between the device electrodes. The nature of the different vibration modes detected has been studied and compared with that obtained by a finite element model based simulation (COMSOL Multiphysics), showing flexural as well as torsional modes. The correspondence between theoretical and experimental data is reasonably good, probing the viability of this high throughput and CMOS compatible fabrication process. To complete the study, X-ray diffraction as well as d33 piezoelectric coefficient measurements were also carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo del presente estudio fue analizar los cambios en el rendimiento en función de dos métodos de entrenamiento, el desarrollado mediante electro-estimulación muscular integral (EMI) frente a otro en el que se utilizaron bandas elásticas y que denominamos entrenamiento funcional con elásticos (EFE). La muestra estuvo compuesta por un grupo de diez (N=10) personas físicamente activas (23,04 ± 2,5 años). Se utilizó un diseño cuasi-experimental con medidas pre-post. Y fueron analizados los resultados de las pruebas: salto vertical con ayuda de brazos; y velocidad de desplazamiento en una carrera de ida y vuelta de 12 metros de distancia (6+6). Se realizó un análisis descriptivo de casos y medias. Y dado el tamaño de la muestra se calculó el tamaño del efecto, el cual fue bajo o moderado (d<0,5). Por último se compararon las diferencias de las medias de los grupos mediante la U de Mann Whitney, y las diferencias de las medias en función del tiempo (pre-post) mediante Friedman; en ambos casos los resultados no fueron significativos (p<0,5). En cuanto a los valores descriptivos del pre-post en ambos grupos: el grupo que entrenó con bandas elásticas obtuvo mejores resultados en ambas pruebas que el grupo que entrenó con EMI. En conclusión, el entrenamiento con bandas elásticas, a pesar de no ser significativo, parece mostrarse más efectivo que el entrenamiento con electro-estimulación muscular integral. Si bien, dadas las limitaciones del estudio estos datos hay que tomarlos con la pertinente cautela.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the development of the Sample Fetch Rover (SFR), studied for Mars Sample Return (MSR), an international campaign carried out in cooperation between the National Aeronautics and Space Administration (NASA) and the European Space Agency (ESA). The focus of this document is the design of the electro-mechanical systems of the rover. After placing this work into the general context of robotic planetary exploration and summarising the state of the art for what concerns Mars rovers, the architecture of the Mars Sample Return Campaign is presented. A complete overview of the current SFR architecture is provided, touching upon all the main subsystems of the spacecraft. For each area, it is discussed what are the design drivers, the chosen solutions and whether they use heritage technology (in particular from the ExoMars Rover) or new developments. This research focuses on two topics of particular interest, due to their relevance for the mission and the novelty of their design: locomotion and sample acquisition, which are discussed in depth. The early SFR locomotion concepts are summarised, covering the initial trade-offs and discarded designs for higher traverse performance. Once a consolidated architecture was reached, the locomotion subsystem was developed further, defining the details of the suspension, actuators, deployment mechanisms and wheels. This technology is presented here in detail, including some key analysis and test results that support the design and demonstrate how it responds to the mission requirements. Another major electro-mechanical system developed as part of this work is the one dedicated to sample tube acquisition. The concept of operations of this machinery was defined to be robust against the unknown conditions that characterise the mission. The design process led to a highly automated robotic system which is described here in its main components: vision system, robotic arm and tube storage.