342 resultados para edentulous
Resumo:
The aim of this study was to relate the clinical case of a patient with oral lichen planus (OLP) and a history of epidermoid carcinoma associated with metallic restorations. The etiology of OLP is a mucocutaneous disease, which is poorly understood. Studies point to the potential of malignant transformation of OLP and its association with metallic restorations. The metallic restorations were replaced by crowns with a ceramic covering associated and osseointegrated implants in the edentulous areas. About 1 year later, it was observed a bilateral regression of the tongue lesions. The replacement of metallic restorations can contribute to improvement of OLP.
Resumo:
The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.
Resumo:
Purpose: Trying to provide more anatomical data to the oral and maxillofacial surgeons regarding to orthognathic surgery, specifically about sagittal split osteotomy, the authors accomplished an anatomical study in dry human jaws, measuring the thickness in four previously established points of the body and mandibular ramus, at the usual spots used for the internal fixation by screws. Material and Methods: The authors also use the data collected to evaluate if there are significant differences between the group I (human dry mandibles with teeth) and group II (edentulous human dry mandibles). Results: For the group I the authors found the following results: x1 = 14,48, x2 = 14,94, x3=12,82 and x4 = 9,41, being the x2 the thickest point, and the least thick the x4. However in the group II, the found medium values were: x1 = 13,38, x2 = 13,08, x3 = 11,63 and x4 = 12,18, being the thickest point in that group the x1 and the least thick x3. The coefficient of simple correlation between the variables (group I and II) revealed a value of 0,6194, being this difference no significant at the meaning level of 95%.
Resumo:
Periodontitis is a chronic inflammatory disease that results in the destruction of teeth and their supporting tissues with subsequent tooth loss. The replacement of missing teeth for implant-supported restorations has proven to be a highly predictable treatment method with good long-term prognosis. However, some consequences of tooth loss prevents dental implant placement in an ideal position, where regenerative procedures are necessary for this type of rehabilitation. Less invasive procedures such as conventional prosthesis emerge as a therapeutic option in cases where there is enough bone structure for implants and patient´s non-acceptance for invasive procedures. Thus, this paper aims to present the resolution of rehabilitation through a noninvasive and multidisciplinary treatment. One female patient referred to the clinic presented maladaptive bilateral mandibular fixed prostheses, endodontic lesions, gingival recession, and root sensitivity. For proper resolution of this case, an association among osseointegrated implants, fixed partial prosthesis, tooth extraction, and aesthetic periodontal procedures with the use of subepithelial connective tissue graft was proposed. After two years, the patient shows excellent aesthetics and chewing. Within the limits of this scenario, this paper discusses the various factors that may affect the choice of a particular treatment modality for the rehabilitation of edentulous single spaces.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aim: The aim of this report is to describe a quick and simple method of positioning retention magnets when deformed patients are rehabilitated with an oculopalpebral prostheses attached to a maxillary denture/obturator. Background: In patients with deformities requiring complex rehabilitations, the use of magnets is the most efficient means of providing combined prostheses with retention quality and stability. Usually prostheses with magnets are in sections and have a magnet in each section. When the sections are put together properly, the magnets are attracted to each other and retain the sections. Report: An edentulous patient presented for a post-surgical evaluation of a maxillofacial prosthesis used to repair a partial maxillectomy and left orbital exoneration which removed all adjacent tissues leaving an open communication between the oral, nasal, and orbital cavities. The proposed treatment plan included construction of a maxillary complete denture with a palatal obturator and a mandibular complete denture. Magnets were used to attach the oculopalpebral prosthesis to the maxillary denture/obturator. Summary: Use of retention magnets simplify the clinical and laboratorial phase, retains the denture, and makes it stable and comfortable for the patient. This treatment is one successful approach to the restoration of oral function and increases the patient’s quality of life.
Resumo:
A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported.
Resumo:
Short implants are increasingly used, but there is doubt about their performance being similar to that of regular implants. The aim of this study was to compare the mechanical stability of short implants vs. regular implants placed in the edentulous posterior mandible. Twenty-three patients received a total of 48 short implants (5 × 5.5 mm and 5 × 7 mm) and 42 regular implants (4 × 10 mm and 4 × 11.5 mm) in the posterior mandible. Patients who received short implants had <10 mm of bone height measured from the bone crest to the outer wall of the mandibular canal. Resonance frequency analysis (RFA) was performed at time intervals T0 (immediately after implant placement), T1 (after 15 days), T2 (after 30 days), T3 (after 60 days), and T4 (after 90 days). The survival rate after 90 days was 87.5% for the short implants and 100% for regular implants (P < 0.05). There was no significant difference between the implants in time intervals T1, T2, T3, and T4. In T0, the RFA values of 5 × 5.5 implants were higher than values of 5 × 7 and 4 × 11.5 implants (P < 0.05). A total of six short implants that were placed in four patients were lost (three of 5 × 5.5 mm and three of 5 × 7 mm). Three lost implants started with high ISQ values, which progressively decreased. The other three lost implants started with a slightly lower ISQ value, which rose and then began to fall. Survival rate of short implants after 90 days was lower than that of regular implants. However, short implants may be considered a reasonable alternative for rehabilitation of severely resorbed mandibles with reduced height, to avoid performing bone reconstruction before implant placement. Patients need to be aware of the reduced survival rate compared with regular implants before implant placement to avoid disappointments.
Resumo:
The purpose of this review is to estimate the prevalence of peri-implantitis, as well as to determine possible risk factors associated with its development in patients treated with oral implants. Although implant therapy has been identified as a successful and predictable treatment for partially and fully edentulous patients, complications and failures can occur. Peri-implantitis is considered a biologic complication that results in bone loss around implants and may lead to implant treatment failure. A great variation has been observed in the literature regarding the prevalence of peri-implantitis according to the diagnostic criteria used to define peri-implantitis. The prevalence ranges from 4.7 to 43% at implant level, and from 8.9 to > 56% at patient level. Many risk factors that may lead to the establishment and progression of peri-implantitis have been suggested. There is strong evidence that presence and history of periodontitis are potential risk factors for peri-implantitis. Cigarette smoking has not yet been conclusively established as a risk factor for peri-implantitis, although extra care should be taken with dental implant in smokers. Other risk factors, such as diabetes, genetic traits, implant surface roughness and presence of keratinized mucosa still require further investigation. Peri-implantitis is not an uncommon complication following implant therapy. A higher prevalence of peri-implantitis has been identified for patients with presence or history of periodontal disease and for smokers. Until now, a true risk factor for peri-implantitis has not been established. Supportive maintenance program is essential for the long-term success of treatments with oral implants. The knowledge of the real impact of peri-implantitis on the outcome of treatments with oral implants as well as the identification of risk factors associated to this inflammatory condition are essential for the development of supportive maintenance programs and the establishment of prevention protocols.
Resumo:
The aim of this study was to evaluate the survival of single dental implants subjected to immediate function. Twelve patients with edentulous areas in the posterior mandible were included in the study. All received at least one regular platform dental implant (3.75mm×11mm or 3.75mm×13mm). Clinical and radiographic parameters were evaluated. The survival rate after 12 months was 83.3%. The implants showed no clinical mobility, had implant stability quotient values (ISQ; Osstell) around 70, bone loss of up to 2mm, and a probing depth of ≤3mm. Although the posterior mandible is an area in which the immediate loading of dental implants should be performed with caution, this treatment presented a good success rate in the present study sample.