623 resultados para diagnosing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The diagnosis of leprosy continues to be based on clinical symptoms and early diagnosis and treatment are critical to preventing disability and transmission. Sensitive and specific laboratory tests are not available for diagnosing leprosy. Despite the limited applicability of anti-phenolic glycolipid-I (PGL-I) serology for diagnosis, it has been suggested as an additional tool to classify leprosy patients (LPs) for treatment purposes. Two formats of rapid tests to detect anti-PGL-I antibodies [ML immunochromatography assay (ICA) and ML Flow] were compared in different groups, multibacillary patients, paucibacillary patients, household contacts and healthy controls in Brazil and Nepal. High ML Flow intra-test concordance was observed and low to moderate agreement between the results of ML ICA and ML Flow tests on the serum of LPs was observed. LPs were "seroclassified" according to the results of these tests and the seroclassification was compared to other currently used classification systems: the World Health Organization operational classification, the bacilloscopic index and the Ridley-Jopling classification. When analysing the usefulness of these tests in the operational classification of PB and MB leprosy for treatment and follow-up purposes, the ML Flow test was the best point-of-care test for subjects in Nepal and despite the need for sample dilution, the ML ICA test yielded better performance among Brazilian subjects. Our results identified possible ways to improve the performance of both tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A cohort of 123 adult contacts was followed for 18‐24 months (86 completed the follow-up) to compare conversion and reversion rates based on two serial measures of QuantiFERON (QFT) and tuberculin skin test (TST) (PPD from TUBERSOL, Aventis Pasteur, Canada) for diagnosing latent tuberculosis (TB) in household contacts of TB patients using conventional (C) and borderline zone (BZ) definitions. Questionnaires were used to obtain information regarding TB exposure, TB risk factors and socio-demographic data. QFT (IU/mL) conversion was defined as <0.35 to ≥0.35 (C) or <0.35 to >0.70 (BZ) and reversion was defined as ≥0.35 to <0.35 (C) or ≥0.35 to <0.20 (BZ); TST (mm) conversion was defined as <5 to ≥5 (C) or <5 to >10 (BZ) and reversion was defined as ≥5 to <5 (C). The QFT conversion and reversion rates were 10.5% and 7% with C and 8.1% and 4.7% with the BZ definitions, respectively. The TST rates were higher compared with QFT, especially with the C definitions (conversion 23.3%, reversion 9.3%). The QFT conversion and reversion rates were higher for TST ≥5; for TST, both rates were lower for QFT <0.35. No risk factors were associated with the probability of converting or reverting. The inconsistency and apparent randomness of serial testing is confusing and adds to the limitations of these tests and definitions to follow-up close TB contacts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Histology is the gold standard for diagnosing acute rejection and hepatitis C recurrence after liver transplantation. However, differential diagnosis between the two can be difficult. We evaluated the role of C4d staining and quantification of hepatitis C virus (HCV) RNA levels in liver tissue. This was a retrospective study of 98 liver biopsy samples divided into four groups by histological diagnosis: acute rejection in patients undergoing liver transplant for hepatitis C (RejHCV+), HCV recurrence in patients undergoing liver transplant for hepatitis C (HCVTx+), acute rejection in patients undergoing liver transplant for reasons other than hepatitis C and chronic hepatitis C not transplanted (HCVTx-). All samples were submitted for immunohistochemical staining for C4d and HCV RNA quantification. Immunoexpression of C4d was observed in the portal vessels and was highest in the HCVTx- group. There was no difference in C4d expression between the RejHCV+ and HCVTx+ groups. However, tissue HCV RNA levels were higher in the HCVTx+ group samples than in the RejHCV+ group samples. Additionally, there was a significant correlation between tissue and serum levels of HCV RNA. The quantification of HCV RNA in liver tissue might prove to be an efficient diagnostic test for the recurrence of HCV infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Early studies in patients with systemic lupus erythematosus (SLE) reported increased incidence of tuberculosis. The tuberculin skin test (TST) is the technique of choice to detect latent tuberculosis infection (LTBI) but has several limitations. OBJECTIVES We compared TST and the newer T.SPOT.TB test to diagnose LTBI in SLE patients. METHODS In this observational cohort study conducted between August 2009 and February 2012, we recruited 92 patients from those attending the SLE clinic of our university hospital. Data recorded were epidemiological and sociodemographic characteristics. Laboratory analyses included TST and T.SPOT.TB tests. RESULTS Of the patients studied, 92% were women with an average age of 42.7 years. Overall, the degree of correlation between the two tests was low (Kappa index = 0.324) but was better in patients not receiving corticosteroids (CTC)/immunosuppressive (IS) therapy (Kappa = 0.436) and in those receiving hydroxychloroquine (Kappa = 0.473). While TST results were adversely affected by those receiving CTC and/or IS drugs (P = 0.021), the T.SPOT.TB results were not. CONCLUSION Although the TST test remains a useful tool for diagnosing LTBI in SLE patients, the T.SPOT.TB test is perhaps better employed when the patient is receiving CTC and/or IS drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: We investigated the incidence and distribution of post-mortem gas detected with multidetector computed tomography (MDCT) to identify factors that could distinguish artifactual gas from cardiac air embolism. MATERIAL AND METHODS: MDCT data of 119 cadavers were retrospectively examined. Gas was semiquantitatively assessed in selected blood vessels, organs, and body spaces (82 total sites). RESULTS: Seventy-four of the 119 cadavers displayed gas (62.2%; CI 95% 52.8-70.9), and 56 (75.7%) displayed gas in the heart. Most gas was detected in the hepatic parenchyma (40%), right heart (38% ventricle, 35% atrium), inferior vena cava (30% infrarenally, 26% suprarenally), hepatic veins (26% left, 29% middle, 22% right), and portal spaces (29%). Male cadavers displayed gas more frequently than female cadavers. Gas was detected 5-84 hours after death; therefore, the post-mortem interval could not reliably predict gas distribution (rho = 0.719, p < 0.0001). We found that a large amount of putrefaction-generated gas in the right heart was associated with aggregated gas bubbles in the hepatic parenchyma (sensitivity = 100%, specificity = 89.7%). In contrast, gas in the left heart (sensitivity = 41.7%, specificity = 100%) or in periumbilical subcutaneous tissues (sensitivity = 50%, specificity = 96.3%) could not predict gas due to putrefaction. CONCLUSION: This study is the first to show that the appearance of post-mortem gas follows a specific distribution pattern. An association between intracardiac gas and hepatic parenchymal gas could distinguish between post-mortem-generated gas and vital air embolism. We propose that this finding provides a key for diagnosing death due to cardiac air embolism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: An accurate, noninvasive technique for the diagnosis of coronary disease would be an important advance. We investigated the accuracy of coronary magnetic resonance angiography among patients with suspected coronary disease in a prospective, multicenter study. METHODS: Coronary magnetic resonance angiography was performed during free breathing in 109 patients before elective x-ray coronary angiography, and the results of the two diagnostic procedures were compared. RESULTS: A total of 636 of 759 proximal and middle segments of coronary arteries (84 percent) were interpretable on magnetic resonance angiography. In these segments, 78 (83 percent) of 94 clinically significant lesions (those with a > or = 50 percent reduction in diameter on x-ray angiography) were also detected by magnetic resonance angiography. Overall, coronary magnetic resonance angiography had an accuracy of 72 percent (95 percent confidence interval, 63 to 81 percent) in diagnosing coronary artery disease. The sensitivity, specificity, and accuracy for patients with disease of the left main coronary artery or three-vessel disease were 100 percent (95 percent confidence interval, 97 to 100 percent), 85 percent (95 percent confidence interval, 78 to 92 percent), and 87 percent (95 percent confidence interval, 81 to 93 percent), respectively. The negative predictive values for any coronary artery disease and for left main artery or three-vessel disease were 81 percent (95 percent confidence interval, 73 to 89 percent) and 100 percent (95 percent confidence interval, 97 to 100 percent), respectively. CONCLUSIONS: Among patients referred for their first x-ray coronary angiogram, three-dimensional coronary magnetic resonance angiography allows for the accurate detection of coronary artery disease of the proximal and middle segments. This noninvasive approach reliably identifies (or rules out) left main coronary artery or three-vessel disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The design of control, estimation or diagnosis algorithms most often assumes that all available process variables represent the system state at the same instant of time. However, this is never true in current network systems, because of the unknown deterministic or stochastic transmission delays introduced by the communication network. During the diagnosing stage, this will often generate false alarms. Under nominal operation, the different transmission delays associated with the variables that appear in the computation form produce discrepancies of the residuals from zero. A technique aiming at the minimisation of the resulting false alarms rate, that is based on the explicit modelling of communication delays and on their best-case estimation is proposed

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Skin patch test is the gold standard method in diagnosing contact allergy. Although used for more than 100 years, the patch test procedure is performed with variability around the world. A number of factors can influence the test results, namely the quality of reagents used, the timing of the application, the patch test series (allergens/haptens) that have been used for testing, the appropriate interpretation of the skin reactions or the evaluation of the patient's benefit. METHODS We performed an Internet -based survey with 38 questions covering the educational background of respondents, patch test methods and interpretation. The questionnaire was distributed among all representatives of national member societies of the World Allergy Organization (WAO), and the WAO Junior Members Group. RESULTS One hundred sixty-nine completed surveys were received from 47 countries. The majority of participants had more than 5 years of clinical practice (61 %) and routinely carried out patch tests (70 %). Both allergists and dermatologists were responsible for carrying out the patch tests. We could observe the use of many different guidelines regardless the geographical distribution. The use of home-made preparations was indicated by 47 % of participants and 73 % of the respondents performed 2 or 3 readings. Most of the responders indicated having patients with adverse reactions, including erythroderma (12 %); however, only 30 % of members completed a consent form before conducting the patch test. DISCUSSION The heterogeneity of patch test practices may be influenced by the level of awareness of clinical guidelines, different training backgrounds, accessibility to various types of devices, the patch test series (allergens/haptens) used for testing, type of clinical practice (public or private practice, clinical or research-based institution), infrastructure availability, financial/commercial implications and regulations among others. CONCLUSION There is a lack of a worldwide homogeneity of patch test procedures, and this raises concerns about the need for standardization and harmonization of this important diagnostic procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: BRAF is mutated in 50-60% of melanomas, but BRAF mutation in sarcomas has not been systematically evaluated. Some melanomas are spindled and may show no immunohistochemical evidence of melanocytic differentiation. Similarly, many sarcomas are undifferentiated, i.e. undifferentiated pleomorphic sarcomas (UPS). Diagnosing melanoma versus sarcoma in an undifferentiated spindle cell malignancy can be challenging. Our aim was to evaluate the prevalence of BRAF mutation in sarcomas and the use of BRAF mutational status in the diagnosis of spindle cell malignancies. METHODS AND RESULTS: BRAF mutational analysis was performed on tissue from 104 patients: 90 with sarcoma only (50 UPS) and 14 with sarcoma and melanoma (seven UPS). In the sarcoma-only group, BRAF mutation was absent. In the sarcoma-melanoma group, three sarcomas showed BRAF mutation; all were UPS, occurred after the melanomas and did not stain for melanocytic markers. One melanoma-sarcoma pair showed identical BRAF V600E mutations. CONCLUSIONS: The presence of BRAF mutation in these tumours raises the possibility that poorly differentiated spindle cell malignancies with BRAF mutation may represent melanomas, and BRAF mutational analysis should be considered in a patient with a spindle cell malignancy and a history of melanoma, as a positive result may indicate de-differentiated melanoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to assess the diagnostic potential of urinary metanephrines and 3-methoxytyramine compared to urinary catecholamine determination in diagnosing antemortem cold exposure and fatal hypothermia. 83 cases of fatal hypothermia and 144 control cases were included in this study. Catecholamines (adrenaline, noradrenaline and dopamine), metanephrines (metanephrine, normetanephrine) and 3-methoxytyramine were measured in urine collected during autopsy. All tested analytes were significantly higher in hypothermia cases compared to control subjects and displayed a generally satisfying discriminative value, thus indicating urinary catecholamines and their metabolites as reliable markers of cold-related stress and hypothermia related-deaths. Metanephrine and adrenaline had the best discriminative value between hypothermia and control cases compared to other tested analytes, though with different sensitivity and specificity. These can therefore be considered the most suitable markers of cold-related stress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: The aim of this article is to review the forensic literature covering the postmortem investigations that are associated with alcoholic ketoacidosis fatalities and report the results of our own analyses. METHODS: Eight cases of suspected alcoholic ketoacidosis that had undergone medico-legal investigations in our facility from 2011 to 2013 were retrospectively selected. A series of laboratory parameters were measured in whole femoral blood, postmortem serum from femoral blood, urine and vitreous humor in order to obtain a more general overview on the biochemical and metabolic changes that occur during alcoholic ketoacidosis. Most of the tested parameters were chosen among those that had been described in clinical and forensic literature associated with alcoholic ketoacidosis and its complications. RESULTS: Ketone bodies and carbohydrate-deficient transferrin levels were increased in all cases. Biochemical markers of generalized inflammation, volume depletion and undernourishment showed higher levels. Adaptive endocrine reactions involving insulin, glucagon, cortisol and triiodothyronine were also observed. CONCLUSIONS: Metabolic and biochemical disturbances characterizing alcoholic ketoacidosis can be reliably identified in the postmortem setting. The correlation of medical history, autopsy findings and biochemical results proves therefore decisive in identifying pre-existing disorders, excluding alternative causes of death and diagnosing alcoholic ketoacidosis as the cause of death.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Because ambulatory blood pressure monitoring (ABPM) is not available everywhere, the objective of the study was to determine whether nurse-measured blood pressure could be an acceptable substitute to ABPM. METHODS: We analyzed the data of 2385 consecutive patients referred to our hypertension clinic for the performance of ABPM. Before ambulatory monitoring was performed, a nurse-measured BP was obtained three times using a Y-tube connecting the sphygmomanometer and the recorder. We compared the mean value of the three nurse-measured blood pressures with that of the 12h daytime ambulatory monitoring, considered as the reference. RESULTS: The difference between the nurse-measured and the ambulatory blood pressure was small but statistically significant, indicating that nurse-measured blood pressure tends to overestimate both diastolic and systolic blood pressure. The difference between the nurse blood pressure and ABPM was greater among treated hypertensive patients than untreated patients. To diagnose hypertension, defined as a blood pressure of over 140/90mmHg by ABPM, the positive predictive value of the nurse blood pressure was 0.81 and the negative predictive value 0.63. However, these predictive values could be improved with less stringent cut-off values of blood pressure. Thus, for a diastolic blood pressure above 100mmHg, the positive predictive value of nurse blood pressure was 0.55 and the negative predictive value 0.91. These figures were relatively similar for previously treated and untreated patients. CONCLUSION: Nurse blood pressure is less accurate than ABPM in diagnosing hypertension, defined as a blood pressure of over 140/90mmHg. It could, however, be an acceptable substitute, especially to exclude people who do not need to be treated, in situations where lower resources require a less rigorous definition of hypertension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Adrenal insufficiency is a rare and potentially lethal disease if untreated. Several clinical signs and biological markers are associated with glucocorticoid failure but the importance of these factors for diagnosing adrenal insufficiency is not known. In this study, we aimed to assess the prevalence of and the factors associated with adrenal insufficiency among patients admitted to an acute internal medicine ward. METHODS: Retrospective, case-control study including all patients with high-dose (250 μg) ACTH-stimulation tests for suspected adrenal insufficiency performed between 2008 and 2010 in an acute internal medicine ward (n = 281). Cortisol values <550 nmol/l upon ACTH-stimulation test were considered diagnostic for adrenal insufficiency. Area under the ROC curve (AROC), sensitivity, specificity, negative and positive predictive values for adrenal insufficiency were assessed for thirteen symptoms, signs and biological variables. RESULTS: 32 patients (11.4%) presented adrenal insufficiency; the others served as controls. Among all clinical and biological parameters studied, history of glucocorticoid withdrawal was the only independent factor significantly associated with patients with adrenal insufficiency (Odds Ratio: 6.71, 95% CI: 3.08 -14.62). Using a logistic regression, a model with four significant and independent variable was obtained, regrouping history of glucocorticoid withdrawal (OR 7.38, 95% CI [3.18 ; 17.11], p-value <0.001), nausea (OR 3.37, 95% CI [1.03 ; 11.00], p-value 0.044), eosinophilia (OR 17.6, 95% CI [1.02; 302.3], p-value 0.048) and hyperkalemia (OR 2.41, 95% CI [0.87; 6.69], p-value 0.092). The AROC (95% CI) was 0.75 (0.70; 0.80) for this model, with 6.3 (0.8 - 20.8) for sensitivity and 99.2 (97.1 - 99.9) for specificity. CONCLUSIONS: 11.4% of patients with suspected adrenal insufficient admitted to acute medical ward actually do present with adrenal insufficiency, defined by an abnormal response to high-dose (250 μg) ACTH-stimulation test. A history of glucocorticoid withdrawal was the strongest factor predicting the potential adrenal failure. The combination of a history of glucocorticoid withdrawal, nausea, eosinophilia and hyperkaliemia might be of interest to suspect adrenal insufficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Teoria dos Constrangimentos (TOC) ou das Restrições tem-se mostrado uma valiosa ferramenta de gestão, auxiliando na identificação dos constrangimentos que limitem a capacidade das empresas na prossecução da sua meta. Assim, para as restrições não físicas, a TOC desenvolveu o Processo de Raciocínio que é composto por ferramentas de análise lógica que dão subsídios para o diagnóstico de problemas bem como a formulação de soluções e planos de acção para implementá-las. Neste contexto, este trabalho se propõe a determinar a adequação do Processo de Raciocínio da Teoria dos Constrangimentos numa Instituição de Ensino Superior (IES) como forma de diagnosticar os problemas e propor soluções capazes de permitir a empresa uma melhoria contínua do seu desempenho. Serão avaliadas as ferramentas que compõem o Processo de Raciocínio, que são: Árvore de Realidade Actual, Diagrama de Dispersão de nuvens, Árvore de Realidade Futura, Árvore de Pré-Requisitos e Árvore de Transição. O trabalho inicia-se com uma pesquisa bibliográfica seguida de uma pesquisa de campo e finalizando com uma aplicação do PR numa IES localizada na ilha de São Vicente. A colecta de informações para a análise processou-se mediante a aplicação de um questionário fechado aos discentes e funcionários, questionário aberto aos docentes e entrevista estruturada aos dirigentes, elaborados em coerência com os objectivos que este estudo pretende atingir. Os resultados da aplicação do método aqui apresentado permitiram chegar as conclusões apontadas no capítulo final deste trabalho The Theory of Constraints (TOC) or Restriction Theory has proved to be a valuable management tool, assisting in the identification of constraints that restrict the ability of companies in the pursuit of its goals. Therefore, for the nonphysical constraints, TOC developed the Thinking Process (TP) that consists of logical analysis tools that provide a basis for diagnosing problems and formulating solutions and action plans to implement them. This study aims, thus, to determine the suitability of the use of the Thinking Process of the Theory of Constraints in a Higher Education Institution (HEI) as a way to diagnose problems and propose solutions that enable the firm to continually improve their performance. We will evaluate the tools that make up the TP, which are: Current Reality Tree, Evaporating Cloud Diagram, Future Reality Tree, Prerequisites Tree and Transition Tree. The work starts with a literature review, followed by a field search, and finishes with an application of the reasoning process in a higher education institution, located in São Vicente. The collection of the data for the analysis was processed through the application of a closed questionnaire to students and staff, opened questionnaire to teachers and interviews to management, drafted in line with the objectives that this study aims to reach. The results of the application of the method presented here, allowed us to reach the conclusions drawn in the final chapter of this work.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hepatitis E virus (HEV) is an RNA virus transmitted via the fecal-oral route or through uncooked animal meat products. Of the 4 known genotypes, genotype 3 is responsible for autochthonous infections in industrialized countries, with a seroprevalence in Switzerland estimated as high as 22%. The majority of infections is asymptomatic but a minority of patients, notably men over 50 or with underlying liver disease, can present with severe acute hepatitis. Chronic hepatitis E with HEV of genotype 3 has been observed in immunosuppressed patients, mostly transplant recipients. Serology is not sufficiently sensitive, especially in immunosuppressed patients, making PCR identification the preferred test for diagnosing active infection. Ribavirin or interferon-alpha can be used to treat chronic hepatitis E if reduction of immunosuppressive treatment does not result in viral elimination.