844 resultados para curriculum-based measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents measurements from the ATLAS experiment of the forward-backward asymmetry in the reaction pp→Z/γ∗→l+l−, with l being electrons or muons, and the extraction of the effective weak mixing angle. The results are based on the full set of data collected in 2011 in pp collisions at the LHC at s√ = 7 TeV, corresponding to an integrated luminosity of 4.8 fb−1. The measured asymmetry values are found to be in agreement with the corresponding Standard Model predictions. The combination of the muon and electron channels yields a value of the effective weak mixing angle of 0.2308±0.0005(stat.)±0.0006(syst.)±0.0009(PDF), where the first uncertainty corresponds to data statistics, the second to systematic effects and the third to knowledge of the parton density functions. This result agrees with the current world average from the Particle Data Group fit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Letter reports a measurement of the exclusive γγ→ℓ+ℓ−(ℓ=e,μ) cross-section in proton--proton collisions at a centre-of-mass energy of 7 TeV by the ATLAS experiment at the LHC, based on an integrated luminosity of 4.6 fb−1. For the electron or muon pairs satisfying exclusive selection criteria, a fit to the dilepton acoplanarity distribution is used to extract the fiducial cross-sections. The cross-section in the electron channel is determined to be σexcl.γγ→e+e−=0.428±0.035(stat.)±0.018(syst.) pb for a phase-space region with invariant mass of the electron pairs greater than 24 GeV, in which both electrons have transverse momentum pT>12 GeV and pseudorapidity |η|<2.4. For muon pairs with invariant mass greater than 20 GeV, muon transverse momentum pT>10 GeV and pseudorapidity |η|<2.4, the cross-section is determined to be σexcl.γγ→μ+μ−=0.628±0.032(stat.)±0.021(syst.) pb. When proton absorptive effects due to the finite size of the proton are taken into account in the theory calculation, the measured cross-sections are found to be consistent with the theory prediction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A measurement of the Higgs boson mass is presented based on the combined data samples of the ATLAS and CMS experiments at the CERN LHC in the H→γγ and H→ZZ→4ℓ decay channels. The results are obtained from a simultaneous fit to the reconstructed invariant mass peaks in the two channels and for the two experiments. The measured masses from the individual channels and the two experiments are found to be consistent among themselves. The combined measured mass of the Higgs boson is mH=125.09±0.21(stat.)±0.11(syst.) GeV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A measurement of the top--antitop (tt¯) charge asymmetry is presented using data corresponding to an integrated luminosity of 4.6 fb−1 of LHC pp collisions at a centre-of-mass energy of 7 TeV collected by the ATLAS detector. Events with two charged leptons, at least two jets and large missing transverse momentum are selected. Two observables are studied: AℓℓC based on the identified charged leptons, and Att¯C, based on the reconstructed tt¯ final state. The asymmetries are measured to be AℓℓC=0.024±0.015 (stat.)±0.009 (syst.), Att¯C=0.021±0.025 (stat.)±0.017 (syst.). The measured values are in agreement with the Standard Model predictions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A measurement of W boson production in lead-lead collisions at sNN−−−√=2.76 TeV is presented. It is based on the analysis of data collected with the ATLAS detector at the LHC in 2011 corresponding to an integrated luminosity of 0.14 nb−1 and 0.15 nb−1 in the muon and electron decay channels, respectively. The differential production cross-sections and lepton charge asymmetry are each measured as a function of the average number of participating nucleons ⟨Npart⟩ and absolute pseudorapidity of the charged lepton. The results are compared to predictions based on next-to-leading-order QCD calculations. These measurements are, in principle, sensitive to possible nuclear modifications to the parton distribution functions and also provide information on scaling of W boson production in multi-nucleon systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The tt¯ production cross-section dependence on jet multiplicity and jet transverse momentum is reported for proton--proton collisions at a centre-of-mass energy of 7 TeV in the single-lepton channel. The data were collected with the ATLAS detector at the CERN Large Hadron Collider and comprise the full 2011 data sample corresponding to an integrated luminosity of 4.6 fb−1. Differential cross-sections are presented as a function of the jet multiplicity for up to eight jets using jet transverse momentum thresholds of 25, 40, 60, and 80 GeV, and as a function of jet transverse momentum up to the fifth jet. The results are shown after background subtraction and corrections for all detector effects, within a kinematic range closely matched to the experimental acceptance. Several QCD-based Monte Carlo models are compared with the results. Sensitivity to the parton shower modelling is found at the higher jet multiplicities, at high transverse momentum of the leading jet and in the transverse momentum spectrum of the fifth leading jet. The MC@NLO+HERWIG MC is found to predict too few events at higher jet multiplicities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Double-differential three-jet production cross-sections are measured in proton--proton collisions at a centre-of-mass energy of s√=7TeV using the ATLAS detector at the Large Hadron Collider. The measurements are presented as a function of the three-jet mass (mjjj), in bins of the sum of the absolute rapidity separations between the three leading jets (|Y∗|). Invariant masses extending up to 5 TeV are reached for 8<|Y∗|<10. These measurements use a sample of data recorded using the ATLAS detector in 2011, which corresponds to an integrated luminosity of 4.51fb−1. Jets are identified using the anti-kt algorithm with two different jet radius parameters, R=0.4 and R=0.6. The dominant uncertainty in these measurements comes from the jet energy scale. Next-to-leading-order QCD calculations corrected to account for non-perturbative effects are compared to the measurements. Good agreement is found between the data and the theoretical predictions based on most of the available sets of parton distribution functions, over the full kinematic range, covering almost seven orders of magnitude in the measured cross-section values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several suction–water-content (s-w) calibrations for the filter paper method (FPM) used for soil-suction measurement have been published. Most of the calibrations involve a bilinear function (i.e., two different equations) with an inflection point occurring at 60 kPa

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ternary aluminium oxynitride (AlNxOy) system offers the possibility to obtain a wide range of properties by tailoring the ratio between pure Al, AlNx and AlOy and therefore opening a significant number of possible applications. In this work the thermal behaviour of AlNxOy thin films was analysed by modulated infrared radiometry (MIRR), taking as reference the binary AlOy and AlNx systems. MIRR is a non-contact and non-destructive thermal wave measurement technique based on the excitation, propagation and detection of temperature oscillations of very small amplitudes. The intended change of the partial pressure of the reactive gas (N2 and/or O2) influenced the target condition and hence the deposition characteristics which, altogether, affected the composition and microstructure of the films. Based on the MIRR measurements and their qualitative and quantitative interpretation, some correlations between the thermal transport properties of the films and their chemical/physical properties have been found. Furthermore, the potential of such technique applied in this oxynitride system, which present a wide range of different physical responses, is also discussed. The experimental results obtained are consistent with those reported in previous works and show a high potential to fulfil the demands needed for the possible applications of the systems studied. They are clearly indicative of an adequate thermal response if this particular thin film system is aimed to be applied in small sensor devices or in electrodes for biosignal acquisition, such as those for electroencephalography or electromyography as it is the case of the main research area that is being developed in the group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research studies the phenomenon of national and corporate culture. National culture is the culture the members of a country share and corporate culture is a subculture which members of an organisation share (Schein, 1992). The objective of this research is to reveal if the employees within equivalent Irish and American companies share the same corporate and national culture and to ascertain if, within each company, there is a link between national culture and corporate culture. The object of this study is achieved by replicating research which was conducted by Shing (1997) in Taiwan. Hypotheses and analytical tools developed by Shing are employed in the current study to allow comparison of results between Shing’s study and the current study. The methodology used, called for the measurement and comparison of national and corporate culture in two equivalent companies within the same industry. The two companies involved in this study are both located in Ireland and are of American and Irish origin. A sample of three hundred was selected and the response rate was 54%. The findings from this research are: (1) The two companies involved had different corporate cultures, (2) They had the same national culture, (3) There was no link between national culture and corporate culture within either company, (4) The findings were not similar to those of Shing (1997). The implication of these findings is that national and corporate culture are separate phenomena therefore corporate culture is not a response to national culture. The results of this research are not reflected in the finding’s of Shing (1997), therefore they are context specific. The core recommendation for management is that, corporate culture should take account of national culture. This is because although employees recognise the espoused values of corporate culture (Schein, 1992), they are at the same time influenced by a much stronger force, their national culture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Synchronization of data coming from different sources is of high importance in biomechanics to ensure reliable analyses. This synchronization can either be performed through hardware to obtain perfect matching of data, or post-processed digitally. Hardware synchronization can be achieved using trigger cables connecting different devices in many situations; however, this is often impractical, and sometimes impossible in outdoors situations. The aim of this paper is to describe a wireless system for outdoor use, allowing synchronization of different types of - potentially embedded and moving - devices. In this system, each synchronization device is composed of: (i) a GPS receiver (used as time reference), (ii) a radio transmitter, and (iii) a microcontroller. These components are used to provide synchronized trigger signals at the desired frequency to the measurement device connected. The synchronization devices communicate wirelessly, are very lightweight, battery-operated and thus very easy to set up. They are adaptable to every measurement device equipped with either trigger input or recording channel. The accuracy of the system was validated using an oscilloscope. The mean synchronization error was found to be 0.39 μs and pulses are generated with an accuracy of <2 μs. The system provides synchronization accuracy about two orders of magnitude better than commonly used post-processing methods, and does not suffer from any drift in trigger generation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a new method, based on inertial sensors, to automatically measure at high frequency the durations of the main phases of ski jumping (i.e. take-off release, take-off, and early flight). The kinematics of the ski jumping movement were recorded by four inertial sensors, attached to the thigh and shank of junior athletes, for 40 jumps performed during indoor conditions and 36 jumps in field conditions. An algorithm was designed to detect temporal events from the recorded signals and to estimate the duration of each phase. These durations were evaluated against a reference camera-based motion capture system and by trainers conducting video observations. The precision for the take-off release and take-off durations (indoor < 39 ms, outdoor = 27 ms) can be considered technically valid for performance assessment. The errors for early flight duration (indoor = 22 ms, outdoor = 119 ms) were comparable to the trainers' variability and should be interpreted with caution. No significant changes in the error were noted between indoor and outdoor conditions, and individual jumping technique did not influence the error of take-off release and take-off. Therefore, the proposed system can provide valuable information for performance evaluation of ski jumpers during training sessions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: While Switzerland invests a lot of money in its healthcare system, little is known about the quality of care delivered. The objective of this study was to assess the quality of care provided to patients with diabetes in the Canton of Vaud, Switzerland. METHODS: Cross-sectional study of 406 non-institutionalized adults with type 1 or 2 diabetes. Patients' characteristics, diabetes and process of care indicators were collected using a self-administered questionnaire. Process indicators (past 12 months) included HbA1C check among HbA1C-aware patients, eye assessment by ophtalmologist, microalbuminuria check, feet examination, lipid test, blood pressure and weight measurement, influenza immunization, physical activity recommendations, and dietary recommendations. Item-by-item (each process of care indicator: percentage of patients having received it), composite (mean percentage of recommended care: sum of received processes of care / sum of possible recommended care), and all-or-none (percentage of patients receiving all specified recommended care) measures were computed. RESULTS: Mean age was 64.4 years; 59% were men. Type 1 and type 2 diabetes were reported by 18.2% and 68.5% of patients, respectively, but diabetes type remained undetermined for almost 20% of patients. Patients were treated with oral anti-diabetic drugs (50%), insulin (23%) or both (27%). Of 219 HbA1C-aware patients, 98% reported ≥ one HbA1C check during the last year. Also, ≥94% reported ≥ one blood pressure measurement, ≥ one weight measurement or lipid test, and 68%, 64% and 56% had feet examination, microalbuminuria check and eye assessment, respectively. Influenza immunization was reported by 62% of the patients.The percentage of patients receiving all processes of care ranged between 14.2%-16.9%, and 46.6%-50.7%, when considering ten and four indicators, respectively. Ambulatory care utilization showed little use of multidisciplinary care, and low levels of participation in diabetes-education classes. CONCLUSIONS: While routine processes-of-care were performed annually in most patients, diabetes-specific risk screenings, influenza immunization, physical activity and dietary recommendations were less often reported; this was also the case for multidisciplinary care and participation in education classes. There is room for diabetes care improvement in Switzerland. These results should help define priorities and further develop country-specific chronic disease management initiatives for diabetes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Adolescent Drug Abuse Diagnosis (ADAD) and Health of Nation Outcome Scales for Children and Adolescents (HoNOSCA) are both measures of outcome for adolescent mental health services. AIMS: To compare the ADAD with HoNOSCA; to examine their clinical usefulness. METHODS: Comparison of the ADAD and HoNOSCA outcome measures of 20 adolescents attending a psychiatric day care unit. RESULTS: ADAD change was positively correlated with HoNOSCA change. HoNOSCA assesses the clinic's day-care programme more positively than the ADAD. The ADAD detects a group for which the mean score remains unchanged whereas HoNOSCA does not. CONCLUSIONS: A good convergent validity emerges between the two assessment tools. The ADAD allows an evidence-based assessment and generally enables a better subject discrimination than HoNOSCA. HoNOSCA gives a less refined evaluation but is more economic in time and possibly more sensitive to change. Both assessment tools give useful information and enabled the Day-care Unit for Adolescents to rethink the process of care and of outcome, which benefited both the institution and the patients.