896 resultados para contrast medium


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A perennial problem in recombinant protein expression is low yield of the product of interest. A strategy which has been shown to increase the production of baculovirus-expressed proteins is to utilise fed-batch cultures. One disadvantage of this approach is the time-consuming task of optimising the feeding strategy. Previously, a statistical optimisation routine was applied to develop a feeding strategy that increased the yield of beta-Galactosidase (beta-Gal) by 2.4-fold (Biotechnol. Bioeng, 59 (1998) 178). This involves the single addition of nutrient concentrates (amino acids, lipids. glucose and yeastolate ultrafiltrate) into Sf9 cell cultures grown in SF900II medium. In this study, it is demonstrated that this optimised fed-batch strategy developed for a high-yielding intracellular product beta-Gal could be applied successfully to a relatively low-yielding glycosylated and secreted product such as the dengue virus glycoprotein NS1. Optimised batch infections yielded 4 mug/ml of NS1 at a peak cell density of 4.2 x 10(6) cells/ml. In contrast. optimised fed-batch infections exhibited a 3-fold improvement in yield, with 12 mug ml of NS1 produced at a peak cell density of 11.3 x 10(6) cells/ml. No further improvements in yield were recorded when the feed volumes were doubled and the peak cell density was increased to 23 x 10(6) cells/ml, unless the cultures were stimulated by the addition of 4 mug/ml of 20-Hydroxyecdysone (an insect moulting hormone). In this case, the NS1 yield was increased to 20 mug/ml. which was nearly 5-fold higher than optimised batch cultures. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loss of magnetic medium solids from dense medium circuits is a substantial contributor to operating cost. Much of this loss is by way of wet drum magnetic separator effluent. A model of the separator would be useful for process design, optimisation and control. A review of the literature established that although various rules of thumb exist, largely based on empirical or anecdotal evidence, there is no model of magnetics recovery in a wet drum magnetic separator which includes as inputs all significant machine and operating variables. A series of trials, in both factorial experiments and in single variable experiments, was therefore carried out using a purpose built rig which featured a small industrial scale (700 mm lip length, 900 mm diameter) wet drum magnetic separator. A substantial data set of 191 trials was generated in the work. The results of the factorial experiments were used to identify the variables having a significant effect on magnetics recovery. Observations carried out as an adjunct to this work, as well as magnetic theory, suggests that the capture of magnetic particles in the wet drum magnetic separator is by a flocculation process. Such a process should be defined by a flocculation rate and a flocculation time; the latter being defined by the volumetric flowrate and the volume within the separation zone. A model based on this concept and containing adjustable parameters was developed. This model was then fitted to a randomly chosen 80% of the data, and validated by application to the remaining 20%. The model is shown to provide a satisfactory fit to the data over three orders of magnitude of magnetics loss. (C) 2003 Elsevier Science BY. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Telemedicine promises to revolutionize medical care delivery in rural and remote areas. The ability to accurately evaluate physical impairment via the Internet is important to the possible future provision of Internet-based physiotherapy. This study evaluated the reliability and validity of assessing knee range of motion via the Internet. Two therapists evaluated knee angle on a single subject via two methods of assessment: the Internet and the traditional method (face-to-face). Nine random positions of the knee were chosen with the principal examiner performing 20 face-to-face and two sets of 20 Internet measures in each position (n=540). The secondary therapist performed Internet assessments only. The Internet connection was established at a readily available speed of 17 kbit/s. The Internet-based goniometer was found to be a valid tool for measuring both knee flexion and extension angles. It was shown to possess both high intra and inter-rater reliability. Difference average plots of the scores verified the consistency of measurement between both modes of assessment. The successful evaluation of the physical outcome measure of knee range of motion via the Internet assists the further development of Internet-based physiotherapy applications. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfite dehydrogenase (SDH) from Starkeya novella, a sulfite-oxidizing molybdenum-containing enzyme, has a novel tightly bound αβ-heterodimeric structure in which the Mo cofactor and the c-type heme are located on different subunits. Flash photolysis studies of intramolecular electron transfer (IET) in SDH show that the process is first-order, independent of solution viscosity, and not inhibited by sulfate, which strongly indicates that IET in SDH proceeds directly through the protein medium and does not involve substantial movement of the two subunits relative to each other. The IET results for SDH contrast with those for chicken and human sulfite oxidase (SO) in which the molybdenum domain is linked to a b-type heme domain through a flexible loop, and IET shows a remarkable dependence on sulfate concentration and viscosity that has been ascribed to interdomain docking. The results for SDH provide additional support for the interdomain docking hypothesis in animal SO and clearly demonstrate that dependence of IET on viscosity and sulfate is not an inherent property of all sulfite-oxidizing molybdenum enzymes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nodal shoot cultures of 'Clone 003', a selected Australian papaya cultivar, were cultured on modified De Fossard medium supplemented with chemicals that either promote ethylene evolution or inhibit action while in culture. Nodal shoot cultures grown in the presence of 1-aminocyclopropane carboxylic acid (ACC, 1.0 mM) resulted in a significant reduction in percent fresh and dry weights, shoot length, leaf area, petiole length and chlorophyll content, but leaf development was significantly increased. In contrast, nodal cultures grown in the presence of silver thiosulphate (STS, 0.5 mM) significantly produced the highest percentage of fresh and dry weights, shoot length, leaf production, leaf area expansion, petiole length and leaf chlorophyll content. Nodal cultures and rooted whole plantlets placed in medium-sized (125 mL) culture vessels had significantly better growth than those cultures placed in small (70 mL) or in large (250 mL) vessels. Cultures grown in medium-sized vessels had higher fresh and dry weights, longer shoots, more leaves and larger leaf area than those cultures placed in smaller or larger vessels. Similarly, values for said growth parameters and for chlorophyll content of the nodal and rooted whole plantlets were higher when they were incubated under high light intensity of 120 mumol m(-2)s(-1) at a prevailing temperature of either 20+/-1 C or 25+/-1 C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to characterize how Portuguese Small and Medium Enterprises (SMEs) view the Occupational Health and Safety Management Systems (OHSMSs) certification process, after receiving the Quality Management System (QMS) certification. References were based on the ISO 9001 standard for a QMS and OHSAS 18001 for OHSMS. The method used to evaluate the implemented systems, was by form of questionnaire. Those questioned had to have a certified quality management system, an implemented OHSMS and be a SME. The questionnaire was sent to 300 SMEs; 46 responses were received and validated. Of them, only 12 SMEs had the OHSMS certificate according to OHSAS 18001. Within those 12 companies that participated: 7 SMEs are from the industrial sector; 3 belong to the electricity/telecommunications sector and 2 SMEs are from the trade/services activity sector. The size of the sample was small, but corresponds to Portuguese reality. Moreover, 34 SMEs did not have the OHSMS certificate. The questionnaire requested the main reasons for SMEs to opt for non-certification and it was related with high costs, while the main reasons to certificate were, among others, needed to eliminate or minimize risks to workers. The main benefits that Portuguese SMEs have gained from the referred certifications have been, improved working conditions, ensuring compliance with legislation and better internal communication about risks and hazards. Also presented are the main difficulties in achieving an OHSMS certification including high certification costs, difficulties motivating personnel, difficulties in changing the company’s culture and increased bureaucracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to characterize the situation of Portuguese Small and Medium Enterprises (SMEs) concerning the certification of their Quality Management Systems (QMS), Environmental Management Systems (EMS) and Occupational Health and Safety Management Systems (OHSMS), in their individually form, to identify benefits, drawbacks and difficulties associated with the certification process and to characterize the level of integration that has been achieved. This research was based on a survey carried out by the research team; it was administered to 46 Portuguese SMEs. Our sample comprised 20 firms (43%) from the Trade/Services activity sector, 17 (37%) from the Industrial sector, 5 (11%) from the Electricity/Telecommunications sector and 4 (9%) from the Construction area. All SMEs surveyed were certified according to the ISO 9001 (100%), a quarter of firms were certified according to the ISO 14001 (26.1%) and a few certified by OHSAS 18001 (15.2%). We undertook a multivariate cluster analysis, which enabled grouping variables into homogeneous groups or one or more common characteristics of the SMEs participating in the study. Results show that the main benefits that Portuguese SMEs have gained from the referred certifications have been, among others, an improvement of both their internal organization and external image. We also present the main difficulties in achieving certification. Overall, 7 of the Portuguese SMEs examined indicated that the main benefits of the IMS implementation management included costs reduction, increased employee training and easier compliance of legislation. The respective drawbacks and difficulties are also presented. Finally, we presented the main integrated items in the certified Portuguese SMEs we examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O trabalho descrito no presente documento reporta a preparação de derivados tetrapirrólicos iodados de tipo porfirina tornando-os potenciais veículos a meio de contraste iodado, usado em radiodiagnóstico. Com os resultados deste trabalho irá ser realizado um pedido de patente das moléculas e portanto, o acesso a este trabalho será restrito nos termos do Código da Propriedade Industrial, aprovado pelo Decreto de Lei nº 36/2003 de 5 de Março. Na primeira fase do trabalho, foi sintetizado o derivado porfirínico simétrico, meso-substituído, contendo um total de 8 iodos. Este foi preparado por condensação do pirrol e do aldeído iodado em meio ácido e na presença de nitrobenzeno. Foram ainda preparados as respetivas metaloporfirinas contendo os iões metálicos de manganês e gadolínio. Posteriormente foi avaliada a capacidade destes derivados atenuarem o feixe de raio-X, através da mediação das Unidades de Hounsfield, após serem adquiridas imagens por Tomografia Computorizada. Na segunda fase do trabalho procedeu-se ao estudo da influência destes compostos na diferenciação celular, usando como modelo as células de pré-adipócitos 3T3-L1. Foi avaliada a diferenciação celular, através da quantificação de lípidos das células maduras, marcados com Red Oil O, por espectrofotometria de Visível 3 e 10 dias após a administração dos derivados em estudo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solubility of ethene in water and in the fermentation medium of Xanthobacter Py(2) was determined with a Ben-Naim-Baer type apparatus. The solubility measurements were carried out in the temperature range of (293.15 to 323.15) K and at atmospheric pressure with a precision of about +/- 0.3 %. The Ostwald coefficients, the mole fractions of the dissolved ethene, at the gas partial pressure of 101.325 kPa, and the Henry coefficients, at the water vapor pressure, were calculated using accurate thermodynamic relations. A comparison between the solubility of ethene in water and in the cultivation medium has shown that this gas is about 2.4 % more soluble in pure water. On the other hand, from the solubility temperature dependence, the Gibbs energy, enthalpy, and entropy changes for the process of transferring the solute from the gaseous phase to the liquid solutions were also determined. Moreover, the perturbed-chain statistical associating fluid theory equation of state (PC-SAFT EOS) model was used for the prediction of the solubility of ethene in water. New parameters, k(ij), are proposed for this system, and it was found that using a ky temperature-dependent PC-SAFT EOS describes more accurately the behavior solubilities of ethene in water at 101.325 kPa, improving the deviations to 1 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the electricity market liberalization, distribution and retail companies are looking for better market strategies based on adequate information upon the consumption patterns of its electricity customers. In this environment all consumers are free to choose their electricity supplier. A fair insight on the customer´s behaviour will permit the definition of specific contract aspects based on the different consumption patterns. In this paper Data Mining (DM) techniques are applied to electricity consumption data from a utility client’s database. To form the different customer´s classes, and find a set of representative consumption patterns, we have used the Two-Step algorithm which is a hierarchical clustering algorithm. Each consumer class will be represented by its load profile resulting from the clustering operation. Next, to characterize each consumer class a classification model will be constructed with the C5.0 classification algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we study the optimal natural gas commitment for a known demand scenario. This study implies the best location of GSUs to supply all demands and the optimal allocation from sources to gas loads, through an appropriate transportation mode, in order to minimize total system costs. Our emphasis is on the formulation and use of a suitable optimization model, reflecting real-world operations and the constraints of natural gas systems. The mathematical model is based on a Lagrangean heuristic, using the Lagrangean relaxation, an efficient approach to solve the problem. Computational results are presented for Iberian and American natural gas systems, geographically organized in 65 and 88 load nodes, respectively. The location model results, supported by the computational application GasView, show the optimal location and allocation solution, system total costs and suggest a suitable gas transportation mode, presented in both numerical and graphic supports.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

World Congress of Malacology, Ponta Delgada, July 22-28, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.