894 resultados para computer-aided detection
Resumo:
Smart Grids (SGs) have emerged as the new paradigm for power system operation and management, being designed to include large amounts of distributed energy resources. This new paradigm requires new Energy Resource Management (ERM) methodologies considering different operation strategies and the existence of new management players such as several types of aggregators. This paper proposes a methodology to facilitate the coalition between distributed generation units originating Virtual Power Players (VPP) considering a game theory approach. The proposed approach consists in the analysis of the classifications that were attributed by each VPP to the distributed generation units, as well as in the analysis of the previous established contracts by each player. The proposed classification model is based in fourteen parameters including technical, economical and behavioural ones. Depending of the VPP strategies, size and goals, each parameter has different importance. VPP can also manage other type of energy resources, like storage units, electric vehicles, demand response programs or even parts of the MV and LV distribution network. A case study with twelve VPPs with different characteristics and one hundred and fifty real distributed generation units is included in the paper.
Resumo:
BACKGROUND: Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. METHOD: The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. RESULTS: The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.
Resumo:
Manipulator systems are rather complex and highly nonlinear which makes difficult their analysis and control. Classic system theory is veil known, however it is inadequate in the presence of strong nonlinear dynamics. Nonlinear controllers produce good results [1] and work has been done e. g. relating the manipulator nonlinear dynamics with frequency response [2–5]. Nevertheless, given the complexity of the problem, systematic methods which permit to draw conclusions about stability, imperfect modelling effects, compensation requirements, etc. are still lacking. In section 2 we start by analysing the variation of the poles and zeros of the descriptive transfer functions of a robot manipulator in order to motivate the development of more robust (and computationally efficient) control algorithms. Based on this analysis a new multirate controller which is an improvement of the well known “computed torque controller” [6] is announced in section 3. Some research in this area was done by Neuman [7,8] showing tbat better robustness is possible if the basic controller structure is modified. The present study stems from those ideas, and attempts to give a systematic treatment, which results in easy to use standard engineering tools. Finally, in section 4 conclusions are presented.
Resumo:
O desenvolvimento da tecnologia informática e de melhor hardware, proporcionou ao mercado de aplicações informáticas, um grande crescimento nas últimas décadas. Paralelamente, o aprofundamento e investigação das disciplinas de engenharia industrial, de novas filosofias e tipologias de produção, proporcionam ao mercado de sistemas de informação, uma panóplia de soluções abrangentes a todos os sectores e departamentos das organizações. Apesar da grande oferta, nem sempre existe viabilidade financeira das organizações para adquirirem e/ ou implementarem uma solução eficaz que responda às suas necessidades específicas. A presente dissertação, incide na melhoria do sistema de orçamentação do produto numa indústria de produtos únicos, através de uma plataforma de informação que permita reduzir o tempo de elaboração, melhorando a estimação do tempo de produção. As exigências do mercado em causa, influenciadas pela concorrência de países com mão-de-obra mais barata, prazos de resposta a orçamentos muito curtos e pequenas margens de negociação e lucro, implicam a necessidade de que sejam minimizadas ao máximo as atividades sem valor acrescentado, como o caso da orçamentação. Foi elaborada uma análise à empresa, ao produto - cablagem, às operações e seus recursos em estudo de caso. Após o levantamento das operações de produção executadas na empresa, reuniram-se os tempos referentes aos tempos de elaboração de cada operação, tendo sido estes utilizados para melhorar a estimativa do tempo de produção. A plataforma de informação foi desenvolvida seguindo o processo produtivo de cablagens, princípios de orçamentação e algumas funcionalidades referentes a ferramentas de apoio à produção, tais como, Product Data Management, Computer Aided Design, Bill-of-Material e Visual Aid’s. Estruturada consoante as necessidades da empresa e respeitando a vasta gama de Matérias- Primas intervenientes na produção, a ferramenta desenvolvida proporcionou a redução do tempo de orçamentação e melhoria na estimativa dos tempos de produção. Esta ferramenta é no entanto transversal e com pequenas alterações, poderá ser implementada em qualquer outra indústria de produtos únicos.
Resumo:
This present study aimed to investigate the fatigue life of unused (new) endodontic instruments made of NiTi with control memory by Coltene™ and subjected to the multi curvature of a mandibular first molar root canal. Additionally, the instrument‟s structural behaviour was analysed through non-linear finite element analysis (FEA). The fatigue life of twelve Hyflex™ CM files was assessed while were forced to adopt a stance with multiple radius of curvature, similar to the ones usually found in a mandibular first molar root canal; nine of them were subjected to Pecking motion, a relative movement of axial type. To achieve this, it was designed an experimental setup with the aim of timing the instruments until fracture while worked inside a stainless steel mandibular first molar model with relative axial motion to simulate the pecking motion. Additionally, the model‟s root canal multi-curvature was confirmed by radiography. The non-linear finite element analysis was conducted using the computer aided design software package SolidWorks™ Simulation, in order to define the imposed displacement required by the FEA, it was necessary to model an endodontic instrument with simplified geometry using SolidWorks™ and subsequently analyse the geometry of the root canal CAD model. The experimental results shown that the instruments subjected to pecking motion displayed higher fatigue life values and higher lengths of fractured tips than those with only rotational relative movement. The finite element non-linear analyses shown, for identical conditions, maximum values for the first principal stress lower than the yield strength of the material and those were located in similar positions to the instrument‟s fracture location determined by the experimental testing results.
Resumo:
The performance of parts produced by Free Form Extrusion (FFE), an increasingly popular additive manufacturing technique, depends mainly on their dimensional accuracy, surface quality and mechanical performance. These attributes are strongly influenced by the evolution of the filament temperature and deformation during deposition and solidification. Consequently, the availability of adequate process modelling software would offer a powerful tool to support efficient process set-up and optimisation. This work examines the contribution to the overall heat transfer of various thermal phenomena developing during the manufacturing sequence, including convection and radiation with the environment, conduction with support and between adjacent filaments, radiation between adjacent filaments and convection with entrapped air. The magnitude of the mechanical deformation is also studied. Once this exercise is completed, it is possible to select the material properties, process variables and thermal phenomena that should be taken in for effective numerical modelling of FFE.
Resumo:
Tese de Doutoramento (Programa Doutoral em Engenharia Biomédica)
Resumo:
Relatório de estágio de mestrado em Arqueologia
Resumo:
El crecimiento exponencial del tráfico de datos es uno de los mayores desafíos que enfrentan actualmente los sistemas de comunicaciones, debiendo los mismos ser capaces de soportar velocidades de procesamiento de datos cada vez mas altas. En particular, el consumo de potencia se ha transformado en uno de los parámetros de diseño más críticos, generando la necesidad de investigar el uso de nuevas arquitecturas y algoritmos para el procesamiento digital de la información. Por otro lado, el análisis y evaluación de nuevas técnicas de procesamiento presenta dificultades dadas las altas velocidades a las que deben operar, resultando frecuentemente ineficiente el uso de la simulación basada en software como método. En este contexto, el uso de electrónica programable ofrece una oportunidad a bajo costo donde no solo se evaluan nuevas técnicas de diseño de alta velocidad sino también se valida su implementación en desarrollos tecnológicos. El presente proyecto tiene como objetivo principal el estudio y desarrollo de nuevas arquitecturas y algoritmos en electrónica programable para el procesamiento de datos a alta velocidad. El método a utilizar será la programación en dispositivos FPGA (Field-Programmable Gate Array) que ofrecen una buena relación costo-beneficio y gran flexibilidad para integrarse con otros dispositivos de comunicaciones. Para la etapas de diseño, simulación y programación se utilizaran herramientas CAD (Computer-Aided Design) orientadas a sistemas electrónicos digitales. El proyecto beneficiara a estudiantes de grado y postgrado de carreras afines a la informática y las telecomunicaciones, contribuyendo al desarrollo de proyectos finales y tesis doctorales. Los resultados del proyecto serán publicados en conferencias y/o revistas nacionales e internacionales y divulgados a través de charlas de difusión y/o encuentros. El proyecto se enmarca dentro de un área de gran importancia para la Provincia de Córdoba, como lo es la informática y las telecomunicaciones, y promete generar conocimiento de gran valor agregado que pueda ser transferido a empresas tecnológicas de la Provincia de Córdoba a través de consultorias o desarrollos de productos.
Resumo:
Fuel cell, PEM fuel cell, Network theory, Computer aided modelling, Nonlinear analysis
Resumo:
Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.
Resumo:
Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.
Resumo:
Estudi i disseny de la implantació d'un ERP (Enterprise Resource Planning) en una fàbrica de fruits secs.
Resumo:
Disseny d'un programari de gestió de magatzems on quedin reflectides les seves entrades, sortides i altres operacions pròpies dels magatzems. El programari ha de ser escalable i perdurar en el temps a més a més de permetre operacions d¿actualització, esborrat, addicció de dades i les operacionsfonamentals de consulta.
Resumo:
A pioneer team of students of the University of Girona decided to design and develop an autonomous underwater vehicle (AUV) called ICTINEU-AUV to face the Student Autonomous Underwater Challenge-Europe (SAUC-E). The prototype has evolved from the initial computer aided design (CAD) model to become an operative AUV in the short period of seven months. The open frame and modular design principles together with the compatibility with other robots previously developed at the lab have provided the main design philosophy. Hence, at the robot's core, two networked computers give access to a wide set of sensors and actuators. The Gentoo/Linux distribution was chosen as the onboard operating system. A software architecture based on a set of distributed objects with soft real time capabilities was developed and a hybrid control architecture including mission control, a behavioural layer and a robust map-based localization algorithm made ICTINEU-AUV the winning entry