933 resultados para coefficient of relatedness
Resumo:
Selection of common bean (Phaseolus vulgaris L.) cultivars with enhanced root growth would be a strategy for increasing P uptake and grain yield in tropical soils, but the strong plasticity of root traits may compromise their inclusion in breeding programs. The aim of this study was to evaluate the magnitude of the genotypic variability of root traits in common bean plants at two ontogenetic stages and two soil P levels. Twenty-four common bean genotypes, comprising the four growth habits that exist in the species and two wild genotypes, were grown in 4 kg pots at two levels of applied P (20 and 80 mg kg-1) and harvested at the stages of pod setting and early pod filling. Root area and root length were measured by digital image analysis. Significant genotype × P level and genotype × harvest interactions in analysis of variance indicate that the genotypic variation of root traits depended on soil nutrient availability and the stage at which evaluation was made. Genotypes differed for taproot mass, basal and lateral root mass, root area and root length at both P levels and growth stages; differences in specific root area and length were small. Genotypes with growth habits II (upright indeterminate) and III (prostrate indeterminate) showed better adaptation to limited P supply than genotypes of groups I (determinate) and IV (indeterminate climbing). Between the two harvests, genotypes of groups II and III increased the mass of basal and lateral roots by 40 and 50 %, respectively, whereas genotypes of groups I and IV by only 7 and 19 %. Values of the genotypic coefficient of determination, which estimates the proportion of phenotypic variance resulting from genetic effects, were higher at early pod filling than at pod setting. Correlations between shoot mass and root mass, which could indicate indirect selection of root systems via aboveground biomass, were higher at early pod filling than at pod setting. The results indicate that selection for root traits in common bean genotypes should preferentially be performed at the early pod-filling stage.
Resumo:
Uncorrelated random scale-free networks are useful null models to check the accuracy and the analytical solutions of dynamical processes defined on complex networks. We propose and analyze a model capable of generating random uncorrelated scale-free networks with no multiple and self-connections. The model is based on the classical configuration model, with an additional restriction on the maximum possible degree of the vertices. We check numerically that the proposed model indeed generates scale-free networks with no two- and three-vertex correlations, as measured by the average degree of the nearest neighbors and the clustering coefficient of the vertices of degree k, respectively.
Resumo:
Twitch mouth pressure (Pmo,tw) during magnetic phrenic nerve stimulation and sniff nasal inspiratory pressure (SNIP) were recently proposed as alternative noninvasive methods for assessing inspiratory muscle strength. This study aimed to compare their reproducibility with maximal inspiratory pressure (MIP) in normal subjects. Ten healthy subjects were studied at functional residual capacity in semirecumbent position. Cervical magnetic phrenic nerve stimulation was performed during gentle expiration against an occlusion incorporating a small leak. Constancy of stimulation was controlled by recording diaphragmatic electromyogram. Within and between-session reproducibility of pressure were studied for Pmo,tw, SNIP, and MIP. The subjects were studied during a session of 10 manoeuvres repeated after 1 day and 1 month. The mean values were 16 cmH2O for Pmo,tw, 118 cmH2O for SNIP, and 115 cmH2O for MIP. For the three tests, the within subject variation was small in relation to between-subject variation, with the intraclass correlation coefficient ranging 0.79-0.90 for Pmo,tw, 0.85-0.92 for SNIP, and 0.88-0.92 for MIP. At 1 day interval, the coefficient of repeatability (2 SD of differences) was 3.6 cmH2O for Pmo,tw, 32 cmH2O for SNIP and 28 cmH2O for MIP. At 1 month interval, the coefficient of repeatability was 5.8 cmH2O for Pmo,tw, 23 cmH2O for SNIP and 21 cmH2O for MIP. We conclude that the within session reproducibility of the new tests twitch mouth pressure and sniff nasal inspiratory pressure is sufficient to be clinically useful. For sniff nasal inspiratory pressure, the between session reproducibility established after 1 day was maintained after 1 month. For twitch mouth pressure, the between session reproducibility declined slightly after 1 month. These characteristics should be considered when using these methods to follow an individual patient over time.
Resumo:
OBJECTIVE: The purpose of the present study was to submit the same materials that were tested in the round robin wear test of 2002/2003 to the Alabama wear method. METHODS: Nine restorative materials, seven composites (belleGlass, Chromasit, Estenia, Heliomolar, SureFil, Targis, Tetric Ceram) an amalgam (Amalcap) and a ceramic (IPS Empress) have been submitted to the Alabama wear method for localized and generalized wear. The test centre did not know which brand they were testing. Both volumetric and vertical loss had been determined with an optical sensor. After completion of the wear test, the raw data were sent to IVOCLAR for further analysis. The statistical analysis of the data included logarithmic transformation of the data, the calculation of relative ranks of each material within each test centre, measures of agreement between methods, the discrimination power and coefficient of variation of each method as well as measures of the consistency and global performance for each material. RESULTS: Relative ranks of the materials varied tremendously between the test centres. When all materials were taken into account and the test methods compared with each other, only ACTA agreed reasonably well with two other methods, i.e. OHSU and ZURICH. On the other hand, MUNICH did not agree with the other methods at all. The ZURICH method showed the lowest discrimination power, ACTA, IVOCLAR and ALABAMA localized the highest. Material-wise, the best global performance was achieved by the leucite reinforced ceramic material Empress, which was clearly ahead of belleGlass, SureFil and Estenia. In contrast, Heliomolar, Tetric Ceram and especially Chromasit demonstrated a poor global performance. The best consistency was achieved by SureFil, Tetric Ceram and Chromasit, whereas the consistency of Amalcap and Heliomolar was poor. When comparing the laboratory data with clinical data, a significant agreement was found for the IVOCLAR and ALABAMA generalized wear method. SIGNIFICANCE: As the different wear simulator settings measure different wear mechanisms, it seems reasonable to combine at least two different wear settings to assess the wear resistance of a new material.
Resumo:
ABSTRACT The study of soil chemical and physical properties variability is important for suitable management practices. The aim of this study was to evaluate the spatial variability of soil properties in the Malhada do Meio settlement to subsidize soil use planning. The settlement is located in Chapadinha, MA, Brazil, and has an area of 630.86 ha. The vegetation is seasonal submontane deciduous forest and steppe savanna. The geology is formed of sandstones and siltstones of theItapecuru Formation and by colluvial and alluvial deposits. The relief consists of hills with rounded and flat tops with an average altitude of 67 m, and frequently covered over by ferruginous duricrusts. A total of 183 georeferenced soil samples were collected at the depth of 0.00-0.20 m inPlintossolos, Neossolo andGleissolo. The following chemical variables were analyzed: pH(CaCl2), H+Al, Al, SB, V, CEC, P, K, OM, Ca, Mg, SiO2, Al2O3, and Fe2O3; along with particle size variables: clay, silt, and sand. Descriptive statistical and geostatistical analyses were carried out. The coefficient of variation (CV) was high for most of the variables, with the exception of pH with a low CV, and of sand with a medium CV. The models fitted to the experimental semivariograms of these variables were the exponential and the spherical. The range values were from 999 m to 3,690 m. For the variables pH(CaCl2), SB, and clay, there are three specific areas for land use planning. The central part of the area (zone III), where thePlintossolos Pétricos and Neossolos Flúvicos occur, is the most suitable for crops due to higher macronutrient content, organic matter and pH. Zones I and II are indicated for environmental preservation.
Non-contact assessment of waist circumference: will tape measurements become progressively obsolete?
Resumo:
Waist circumference (WC) is a key variable to assess in health management as it is a proxy of abdominal fat mass and a surrogate marker of cardiometabolic disease risk, including the metabolic syndrome. Recently, a portable non-contact device calculating WC (ViScan) has been developed, which hence allows the tracking of WC independently of the inter-investigators error. We compared WC values obtained with this device with WC measured by simple non-stretchable tape in 74 adults of varying body mass indices (range 17-39 kg/m(2)). The correlation between the two methods was very high (r=0.97, P<0.0001) and the reproducibility (precision) assessed with a rigid phantom was excellent (<1 cm, coefficient of variability<1%). The instrument constitutes a potentially valuable tool for longitudinal surveys and comparative international studies, which require simple but precise measurements of WC in order to track the effect of subtle changes on various health outcomes.
Resumo:
Various site-specific recombination enzymes produce different types of knots or catenanes while acting on circular DNA in vitro and in vivo. By analysing the types of knots or links produced, it is possible to reconstruct the order of events during the reaction and to deduce the molecular "architecture" of the complexes that different enzymes form with DNA. Until recently it was necessary to use laborious electron microscopy methods to identify the types of knots or catenanes that migrate in different bands on the agarose gels used to analyse the products of the reaction. We reported recently that electrophoretic migration of different knots and catenanes formed on the same size DNA molecules is simply related to the average crossing number of the ideal representations of the corresponding knots and catenanes. Here we explain this relation by demonstrating that the expected sedimentation coefficient of randomly fluctuating knotted or catenated DNA molecules in solution shows approximately linear correlation with the average crossing number of ideal configurations of the corresponding knots or catenanes.
Resumo:
Meropenem, a carbapenem antibiotic displaying a broad spectrum of antibacterial activity, is administered in Medical Intensive Care Unit to critically ill patients undergoing continuous veno-venous haemodiafiltration (CVVHDF). However, there are limited data available to substantial rational dosing decisions in this condition. In an attempt to refine our knowledge and propose a rationally designed dosage regimen, we have developed a HPLC method to determine meropenem after solid-phase extraction (SPE) of plasma and dialysate fluids obtained from patients under CVVHDF. The assay comprises the simultaneous measurement of meropenem's open-ring metabolite UK-1a, whose fate has never been studied in CVVHDF patients. The clean-up procedure involved a SPE on C18 cartridge. Matrix components were eliminated with phosphate buffer pH 7.4 followed by 15:85 MeOH-phosphate buffer pH 7.4. Meropenem and UK-1a were subsequently desorbed with MeOH. The eluates were evaporated under nitrogen at room temperature (RT) and reconstituted in phosphate buffer pH 7.4. Separation was performed at RT on a Nucleosil 100-5 microm C18 AB cartridge column (125 x 4 mm I.D.) equipped with a guard column (8 x 4 mm I.D.) with UV-DAD detection set at 208 nm. The mobile phase was 1 ml min(-1), using a step-wise gradient elution program: %MeOH/0.005 M tetrabutylammonium chloride pH 7.4; 10/90-50/50 in 27 min. Over the range of 5-100 microg ml(-1), the regression coefficient of the calibration curves (plasma and dialysate) were >0.998. The absolute extraction recoveries of meropenem and UK-1a in plasma and filtrate-dialysate were stable and ranged from 88-93 to 72-77% for meropenem, and from 95-104 to 75-82% for UK-1a. In plasma and filtrate-dialysate, respectively, the mean intra-assay precision was 4.1 and 2.6% for meropenem and 4.2 and 3.7% for UK-1a. The inter-assay variability was 2.8 and 3.6% for meropenem and 2.3 and 2.8% for UK-1a. The accuracy was satisfactory for both meropenem and UK-1a with deviation never exceeding 9.0% of the nominal concentrations. The stability of meropenem, studied in biological samples left at RT and at +4 degrees C, was satisfactory with < 5% degradation after 1.5 h in blood but reached 22% in filtrate-dialysate samples stored at RT for 8 h, precluding accurate measurements of meropenem excreted unchanged in the filtrate-dialysate left at RT during the CVVHDF procedure. The method reported here enables accurate measurements of meropenem in critically ill patients under CVVHDF, making dosage individualisation possible in such patients. The levels of the metabolite UK-1a encountered in this population of patients were higher than those observed in healthy volunteers but was similar to those observed in patients with renal impairment under hemodialysis.
Resumo:
The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.
Resumo:
The Diagnosis and Recommendation System (DRIS) was applied to eucalypt trees (hybrids of Eucalyptus grandis x E. urophylla) with different ages and growing under different environmental conditions for three different clones. The basic data were obtained from 1,986 trees of commercial stands cultivated in the states of Espírito Santo and south Bahia, Brazil. The DRIS indices were calculated using the Beaufils' Range formula and grouped according to the Nutrient Application Potential Response method. The objective of this paper was to evaluate the N, P and Ca status in eucalypt trees, regarding the tree ages and genetic materials. The DRIS indices discriminated differences in the nutritional status of the trees, both in relation to age and the genetic materials (clones). The results indicated that the deficiency of N and Ca tended to decrease with tree age, whereas the P deficiency tended to increase. Furthermore, of the three evaluated clones, those numbered 00014 and 00034 showed opposite trends regarding to N, P, and Ca nutrition, and the clone numbered 00021, in general, presented the highest degree of unbalanced nutrition of N, P and Ca.
Resumo:
Since integral abutment bridges decrease the initial and maintenance costs of bridges, they provide an attractive alternative for bridge designers. The objective of this project is to develop rational and experimentally verified design recommendations for these bridges. Field testing consisted of instrumenting two bridges in Iowa to monitor air and bridge temperatures, bridge displacements, and pile strains. Core samples were also collected to determine coefficients of thermal expansion for the two bridges. Design values for the coefficient of thermal expansion of concrete are recommended, as well as revised temperature ranges for the deck and girders of steel and concrete bridges. A girder extension model is developed to predict the longitudinal bridge displacements caused by changing bridge temperatures. Abutment rotations and passive soil pressures behind the abutment were neglected. The model is subdivided into segments that have uniform temperatures, coefficients of expansion, and moduli of elasticity. Weak axis pile strains were predicted using a fixed-head model. The pile is idealized as an equivalent cantilever with a length determined by the surrounding soil conditions and pile properties. Both the girder extension model and the fixed-head model are conservative for design purposes. A longitudinal frame model is developed to account for abutment rotations. The frame model better predicts both the longitudinal displacement and weak axis pile strains than do the simpler models. A lateral frame model is presented to predict the lateral motion of skewed bridges and the associated strong axis pile strains. Full passive soil pressure is assumed on the abutment face. Two alternatives for the pile design are presented. Alternative One is the more conservative and includes thermally induced stresses. Alternative Two neglects thermally induced stresses but allows for the partial formation of plastic hinges (inelastic redistribution of forces). Ductility criteria are presented for this alternative. Both alternatives are illustrated in a design example.
Resumo:
Workgroup diversity can be conceptualized as variety, separation, or disparity. Thus, the proper operationalization of diversity depends on how a diversity dimension has been defined. Analytically, the minimal diversity must be obtained when there are no differences on an attribute among the members of a group, however maximal diversity has a different shape for each conceptualization of diversity. Previous work on diversity indexes indicated maximum values for variety (e.g., Blau"s index and Teachman"s index), separation (e.g., standard deviation and mean Euclidean distance), and disparity (e.g., coefficient of variation and the Gini coefficient of concentration), although these maximum values are not valid for all group characteristics (i.e., group size and group size parity) and attribute scales (i.e., number of categories). We demonstrate analytically appropriate upper boundaries for conditional diversity determined by some specific group characteristics, avoiding the bias related to absolute diversity. This will allow applied researchers to make better interpretations regarding the relationship between group diversity and group outcomes.
Resumo:
Single amino acid substitution is the type of protein alteration most related to human diseases. Current studies seek primarily to distinguish neutral mutations from harmful ones. Very few methods offer an explanation of the final prediction result in terms of the probable structural or functional effect on the protein. In this study, we describe the use of three novel parameters to identify experimentally-verified critical residues of the TP53 protein (p53). The first two parameters make use of a surface clustering method to calculate the protein surface area of highly conserved regions or regions with high nonlocal atomic interaction energy (ANOLEA) score. These parameters help identify important functional regions on the surface of a protein. The last parameter involves the use of a new method for pseudobinding free-energy estimation to specifically probe the importance of residue side-chains to the stability of protein fold. A decision tree was designed to optimally combine these three parameters. The result was compared to the functional data stored in the International Agency for Research on Cancer (IARC) TP53 mutation database. The final prediction achieved a prediction accuracy of 70% and a Matthews correlation coefficient of 0.45. It also showed a high specificity of 91.8%. Mutations in the 85 correctly identified important residues represented 81.7% of the total mutations recorded in the database. In addition, the method was able to correctly assign a probable functional or structural role to the residues. Such information could be critical for the interpretation and prediction of the effect of missense mutations, as it not only provided the fundamental explanation of the observed effect, but also helped design the most appropriate laboratory experiment to verify the prediction results.
Resumo:
This research project investigated the use of image analysis to measure the air void parameters of concrete specimens produced under standard laboratory conditions. The results obtained from the image analysis technique were compared to results obtained from plastic air content tests, Danish air meter tests (also referred to as Air Void Analyzer tests), high-pressure air content tests on hardened concrete, and linear traverse tests (as per ASTM C-457). Hardened concrete specimens were sent to three different laboratories for the linear traverse tests. The samples that were circulated to the three labs consisted of specimens that needed different levels of surface preparation. The first set consisted of approximately 18 specimens that had been sectioned from a 4 in. by 4 in. by 18 in. (10 cm by 10 cm by 46 cm) beam using a saw equipped with a diamond blade. These specimens were subjected to the normal sample preparation techniques that were commonly employed by the three different labs (each lab practiced slightly different specimen preparation techniques). The second set of samples consisted of eight specimens that had been ground and polished at a single laboratory. The companion labs were only supposed to retouch the sample surfaces if they exhibited major flaws. In general, the study indicated that the image analysis test results for entrained air content exhibited good to strong correlation to the average values determined via the linear traverse technique. Specimens ground and polished in a single laboratory and then circulated to the other participating laboratories for the air content determinations exhibited the strongest correlation between the image analysis and linear traverse techniques (coefficient of determination, r-squared = 0.96, for n=8). Specimens ground and polished at each of the individual laboratories exhibited considerably more scatter (coefficient of determination, r-squared = 0.78, for n=16). The image analysis technique tended to produce low estimates of the specific surface of the voids when compared to the results from the linear traverse method. This caused the image analysis spacing factor calculations to produce larger values than those obtained from the linear traverse tests. The image analysis spacing factors were still successful at distinguishing between the frost-prone test specimens and the other (more durable) test specimens that were studied in this research project.
Resumo:
Phenotypic virulence analysis was made on population of Pyricularia grisea isolates collected from 10 upland cultivars in three distinct rice breeding sites, with the objective of studying the degree of similarity in the phenotypic virulence among the isolates, the composition of races, and their virulence pattern. Sixteen races were identified based on the reaction type on eight standard international differentials, the predominant ones being IB9 and IB41. The virulence frequency was high on IAC47 and IAC165 among medium and early maturing cultivars, respectively. The frequency of isolates virulent was greater on upland rice cultivars (51.1%) than on irrigated rice cultivars (21.8%). Both virulent and avirulent isolates were present in the population of P. grisea to the known genes in the near isogenic lines. Of72test isolates, 94.4% were virulent for genes Pi3 and Pi4a. Thevirulence frequencies were relatively lower in decreasing order on Pi1, Pi4b and Pi2. Thecoefficient of similarity ranged from 0.28 to1.0 among the isolates pertaining to different races, while within the race IB9, it varied from 0.56 to1.0. Considering the coefficient of similarity of 0.81, 72% of isolates of race IB9 exhibited similar pattern of virulence.