938 resultados para bovine spine
Resumo:
19-Nortestosterone (beta-NT) is banned for use as a growth promoter in food animals within the European Union. For regulatory control purposes, urine and bile samples are routinely screened by immunoassay. The aim of the present study was to compare the ability of two immunoassays, using two rabbit polyclonal antibodies raised against two different NT derivatives, to detect NT residues in bovine bile. One antiserum cross-reacted with both alpha-NT and beta-NT (alpha/beta-NT), whereas the other was specific for alpha-NT. Bile samples from 266 slaughtered cattle were deconjugated and analyzed using both antibodies, with all screening positives (>2 ng ml(-1)) confirmed by high resolution gas chromatography mass spectrometry. The alpha/beta-NT and alpha-NT antibody-based ELISAs screened 39 and 44 samples positive, respectively, with NT confirmed in 22 and 39, respectively. The alpha/beta-NT antibody-based ELISA produced a false-negative rate of 44% compared to 0% for the alpha-NT antibody-based ELISA. Supplementary investigations concluded that a matrix effect was a major cause of the marked differences in false-negative rates. This result underlines the necessity to validate immunoassays in the sample matrix.
Resumo:
Ivermectin, a member of the avermectin group, is frequently used to control parasites in many food producing animal species. A method for the detection and quantification of ivermectin residues in bovine liver has been developed. Liver samples (4 g) were extracted with acetonitrile and applied to a competitive enzyme immunoassay using a polyclonal antiserum raised in rabbits against an ivermectin-transferrin conjugate, The limit of detection of the assay (mean +/- 3s) calculated from the analysis of 24 known negative samples was 1.6 ng g(-1), Intra- and inter-assay RSDs were determined as 8.8 and 14.6%, respectively, using a negative bovine liver sample fortified with 100 ng g(-1) of ivermectin. Four Friesian steers were treated with a pour-on application of ivermectin at a dose rate of 0.5 mg kg(-1) body mass then withdrawn and killed at 7, 14, 21 and 28 d, Livers mere removed and ivermectin residue concentrations determined using the proposed immunoassay procedure, Seven days post-treatment the ivermectin liver concentration was determined as 52.7 ng g(-1), decreasing to 4.1 ng(-1) at 28 d, All immunoassay results were confirmed using high-performance liquid chromatography (HPLC), The immunoassay and HPLC results for invermectin ranged from 1 to 58 ng g(-1) and were in close correlation (r = 0.99).
Resumo:
Zeranol and two Fusarium toxins, alpha-zearalenol and beta-zearalenol, were confirmed by gaschromatography/mass spectrometry (GC/MS) in bovine bile samples referred to this laboratory for analysis. No evidence of zeranol abuse was found on-farm. Given the recent suggestion that zeranol might arise from the metabolism of these Fusarium toxins, and the finding of zeranol in bovine and ovine urine across the EU, it. was concluded that the residues had arisen as a result of natural metabolism.
Resumo:
Haptoglobin (Hp) is recognised as a major acute phase protein in the bovidae and its presence in serum is used as an indicator of inflammation. A mouse monoclonal antibody (1D9) specific for bovine Hp was labelled with a lanthanide (Eu) chelate and used to develop a competitive immunoassay. This competitive immunoassay allowed direct measurement of Hp in serum and was validated for intra- and interassay coefficients of variation (below 8%). Cross-reactivity with other serum proteins was measured (less than 0.1%) and limits of detection for Hp in serum were established for adult male (0.344 mu g/ml) and adult female cattle (1.589 mu g/ml). The immunoassay was compared with an established haptoglobin-haemoglobin binding assay.
Resumo:
The performance of three conventional enzyme and radioimmunoassays routinely used to detect residues of anabolic steroids in cattle sera were compared with dissociation enhanced lanthanide fluorescence immunoassay (DELFIA) kits designed for the hospital market. Slight modifications to the kit reagents were required for the analysis of bovine sera. Owing to the large sample volumes used in conventional assays, detection limits were generally better than those obtained with DELFIA kits, however, assay reproducibility was enhanced using the DELFIA technology. Comparison of sera obtained from cattle implanted with anabolic steroids revealed a good correlation between alternate methods (r(2) from 0.91 to 0.97). The DELFIA kits offer a faster method for measuring estradiol, progesterone and testosterone with adequate sensitivity and in a safer environment than that encountered using radioimmunoassays.
Resumo:
A liquid chromatography-thermospray mass spectrometric assay was developed and validated to confirm the presence of illegal residues of the synthetic androgenic growth promoter, trenbolone acetate, in cattle. The assay was specific for 17alpha-trenbolone, the major bovine metabolite of trenbolone acetate. Methods were developed for the determination of 17alpha-trenbolone in both bile and faeces, the most appropriate matrices for the control of trenbolone acetate abuse. The clean-up.procedure developed relied on enzymatic hydrolysis, followed by sequential liquid-liquid and liquid-solid extraction. The extracts were then subjected to immunoaffinity chromatography. 17alpha-Trenbolone was detected by selected ion monitoring at m/z 271 using positive ion thermospray ionisation. The limit of detection was approximately 0.5 ng/g in faeces and 0.5 ng/ml in bile.
Resumo:
A gas chromatographic/mass spectrometric method is described for the detection of clenbuterol residues in liver, muscle, urine and retina. Tissue samples are first digested using protease and any clenbuterol present is extracted using a simple liquid/liquid extraction procedure. The dried extracts are then derivatized using methylboronic acid and the derivatives are subjected to gas chromatography/mass spectrometry on a magnetic sector instrument. The detection limit of the assay is 0.05 ng g-1 clenbuterol in liver, muscle or urine using a 10 g sample size, and 4 ng g-1 in retina using a 0.5 g sample size. The assay is made very specific by using selected ion monitoring of three ions at a resolution of 3500 and by ion ratio measurements. The precision and reproducibility of the assay are enhanced by the use of a deuterated internal standard, with a typical coefficient of variation of 3%.
Resumo:
Published work has shown that endothelin-l-induced contractility of bovine retinal pericytes is reduced after culture in high concentrations of glucose. The purpose of the present study was to establish the profile of endothelin-l-induced calcium transients in pericytes and to identify changes occurring after culture in high concentrations of glucose. Glucose had no effect on basal levels of cytosolic calcium or on endothelin-l-induced calcium release from intracellular stores. However, influx of calcium from the extracellular medium after endothelin-l stimulation was reduced in pericytes that had been cultured in 25 mM D-glucose. L-type Ca2+ currents were identified by patch clamping. The L-type Ca2+ channel agonist, (-)-Bay K8644, caused less influx of calcium from the extracellular medium in pericytes that had been cultured in 25 mM D-glucose than in those cultured with 5 mM D-glucose. However, 3-O-methylglucose, a nonmetabolizable analogue of glucose which can cause glycation, had similar effects to those of high concentrations of glucose. The results suggest that reduced function of the L-type Ca2+ channel that occurs in bovine retinal pericytes after culture in high concentrations of D-glucose is probably due to glycation of a channel protein.
Resumo:
The effect of simulated hyperglycaemia on bovine retinal pericytes was studied following culture of these cells for 10 days under normal (5 mmol/l) and elevated (25 mmol/l) glucose conditions in the absence of endothelial cells. Pericytes cultured under high ambient glucose exhibited both a delayed and reduced contractile response following stimulation with endothelin-1. Stimulation with 10(-7) mol/l endothelin-1 for 30 s caused significant contraction in cells grown in both 5 mmol/l and 25 mmol/l glucose. The former also contracted significantly with 10(-8) mol/l endothelin-1. Further, at all concentrations tested, statistical comparison of the time course of contraction showed a significant difference (p 0.1) between bovine retinal pericytes grown for 10 days under normo- or hyperglycaemic conditions, it became apparent that the altered contractility in bovine retinal pericytes following culture in high glucose must be due to post-binding intracellular disturbance(s). Indeed, both basal and 15 s post-stimulation with 10(-8) mol/l endothelin-1, levels of inositol trisphosphate were significantly reduced (p
Resumo:
Immunomagnetic separation (IMS) can selectively isolate and concentrate Mycobacterium bovis cells from lymph node tissue to facilitate subsequent detection by PCR (IMS-PCR) or culture (IMS-MGIT). This study describes application of these novel IMS-based methods to test for M. bovis in a survey of 280 bovine lymph nodes (206 visibly lesioned (VL), 74 non-visibly lesioned (NVL)) collected at slaughter as part of the Northern Ireland bovine TB eradication programme. Their performance was evaluated relative to culture. Overall, 174 (62.1%) lymph node samples tested positive by culture, 162 (57.8%) by IMS-PCR (targeting IS6110), and 196 (70.0%) by IMS-MGIT culture. Twelve (6.9%) of the 174 culture positive lymph node samples were not detected by either of the IMS-based methods. However, an additional 78 M. bovis positive lymph node samples (26 (12.6%) VL and 54 (73.0%) NVL) were detected by the IMS-based methods and not by culture. When low numbers of viable M. bovis are present in lymph nodes (e.g. in NVLs of skin test reactor cattle) decontamination prior to culture may adversely affect viability, leading to false negative culture results. In contrast, IMS specifically captures whole M. bovis cells (live, dead or potentially dormant) which are not subject to any deleterious treatment before detection by PCR or MGIT culture. During this study only 2.7% of NVL lymph nodes tested culture positive, whereas 73% of the same samples tested M. bovis positive by the IMS-based tests. Results clearly demonstrate that not only are the IMS-based methods more rapid but they have greater detection sensitivity than the culture approach currently used for the detection of M. bovis infection in cattle.. Adoption of the IMS-based methods for lymph node testing would have the potential to improve M. bovis detection in clinical samples.
Resumo:
The administration of recombinant methionyl bovine somatotropin (rMbST) to dairy cows to increase milk yield remains a common practice in many countries including the USA, Brazil, Mexico, South Africa and Korea, whereas it has been forbidden within the European Union (EU) since 1999. A rapid screening immunoanalytical method capable of the unequivocal determination of rMbST in milk would be highly desirable in order to effectively monitor compliance with the EU-wide ban for home-made or imported dairy products. For decades, the production of specific antibodies for this recombinant isoform of bovine somatotropin (bST) has remained elusive, due to the high degree of sequence homology between both counterparts (e.g. methionine for rMbST in substitution of alanine in bST at the N-terminus). In this study, we compared several immunizing strategies for the production of specific polyclonal antibodies (pAbs), based on the use of the full-length recombinant protein, an rMbST N-terminus peptide fragment and a multiple antigen peptide (MAP) which consists of an oligomeric branching lysine core attached to the first two N-terminus amino acids of rMbST, methionine and phenylalanine (MF-MAP). The immunization with KLH-conjugated MF-MAP led to the production of the pAb with the highest rMbST/bST recognition ratio amongst the generated battery of antibodies. The pAb exhibited a specific binding ability to rMbST in a competitive antigen-coated ELISA format, which avidity was further improved after purification by rMbST N-terminus peptide-based affinity chromatography. These results suggest that immunodiscrimination between structurally related proteins can be achieved using immuno-enhanced immunogens such as MAPs. © 2012 Elsevier B.V.