964 resultados para blood values


Relevância:

30.00% 30.00%

Publicador:

Resumo:

For driving aptitude assessment (DAA), the analysis of several alcohol biomarkers is essential for the detection of alcohol intake besides psycho-medical exploration. In Switzerland, EtG in hair (hEtG) is often the only direct marker for abstinence monitoring in DAA. Therefore, the suitability of phosphatidylethanol (PEth) was investigated as additional biomarker. PEth 16:0/18:1 and 16:0/18:2 were determined by online-SPE-LC-MS/MS in 136 blood samples of persons undergoing DAA and compared to hEtG, determined in hair segments taken at the same time. With a PEth 16:0/18:1 threshold of 210 ng/mL for excessive alcohol consumption, all (n = 30) but one tested person also had hEtG values ≥30 pg/mg. In 54 cases, results are not in contradiction to an abstinence as neither PEth (<20 ng/mL) nor hEtG (<7 pg/mg) was detected. In eight cases, both markers showed moderate consumption. Altogether, PEth and hEtG were in accordance in 68 % of the samples, although covering different time periods of alcohol consumption. With receiver operating characteristic analysis, PEth was evaluated to differentiate abstinence, moderate, and excessive alcohol consumption in accordance with hEtG limits. A PEth 16:0/18:1 threshold of 150 ng/mL resulted in the best sensitivity (70.6 %) and specificity (98.8 %) for excessive consumption. Values between 20 and 150 ng/mL passed for moderate consumption, values <20 ng/mL passed for abstinence. As PEth mostly has a shorter detection window (2-4 weeks) than hEtG (up to 6 months depending on hair length), changes in drinking behavior can be detected earlier by PEth than by hEtG analysis alone. Therefore, PEth helps to improve the diagnostic information and is a valuable additional alcohol marker for DAA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. The natriuretic peptide precursor A (Nppa) and B (Nppb) genes are candidate genes for hypertension and cardiac hypertrophy in the spontaneously hypertensive rat (SHR). The purpose of the present study was to determine the role of the Nppa and Nppb genes in the development of hypertension in the SHR. 2. A cohort (n = 162) of F2 segregating intercross animals was established between strains of hypertensive SHR and normotensive Wistar-Kyoto rats. Blood pressure and heart weight were measured in each rat at 12-16 weeks of age. Rats were genotyped using 11 informative microsatellite markers, distributed in the vicinity of the Nppa marker on rat chromosome 5 including an Nppb marker. The phenotype values were compared with genotype using the computer package MAP-MAKER 3.0 (Whitehead Institute, Boston, MA, USA) to determine whether there was a link between the genetic variants of the natriuretic peptide family and blood pressure or cardiac hypertrophy. 3. A strong correlation was observed between the Nppa marker and blood pressure. A quantitative trait locus (QTL) for blood pressure on chromosome 5 was identified between the Nppa locus and the D5Mgh15 marker, less than 2 cM from the Nppa locus. The linkage score for the blood pressure QTL on chromosome 5 was 3.8 and the QTL accounted for 43% of the total variance of systolic blood pressure, 54% of diastolic blood pressure and 59% of mean blood pressure. No association was found between the Nppb gene and blood pressure. This is the first report of linkage between the Nppa marker and blood pressure in the rat. There was no correlation between the Nppa or Nppb genes or other markers in this region and either heart weight or left ventricular weight in F2 rats. 4. These findings suggest the existence of a blood pressure-dependent Nppa marker variant or a gene close to Nppa predisposing to spontaneous hypertension in the rat. It provides a strong foundation for further detailed genetic studies in congenic strains, which may help to narrow down the location of this gene and lead to positional cloning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To measure haematological values of clinical significance for rusa deer and provide reference data for farmed animals. Design Blood samples were collected regularly from eight male rusa deer from 14 days to 27 months old. Procedure Blood samples, collected by venipuncture, were analysed within 6 hours of collection for red cell count, haemoglobin, packed cell volume, plasma glucose, white cell count and differentials. Results Haemoglobin concentrations appeared to increase with age and ranged from 6.0 to 20.9 g/dL. Packed cell volume and plasma glucose concentration did not appear to vary with age. White cell counts ranged from 6.3 to 7.0 x 10(9)/L and differential counts indicated neutrophils > lymphocytes > monocytes > eosinophils > basophils. In general, the values for packed cell volume, red cell count, mean cell volumes and mean cell haemoglobin concentrations were within ranges previously reported for captive or sedated rusa deer. Conclusions Physical restraint and resultant stress was sufficient to generate some of the effects previously reported for physically immobilised or agitated deer. The values reported here do not differ greatly from those previously reported for rusa deer and can be used as reference values for clinically healthy young farmed male rusa deer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In-vitro experimentation was performed on porcine and human blood to determine their comparative responsiveness to a novel fibrinolytic inhibitor and thereby assess whether the pig is a suitable animal model for subsequent in-vivo testing of this inhibitor. Thromboelastography showed the clots formed from porcine whole blood to be highly resistant to tissue plasminogen activator (t-PA)-catalyzed lysis, and this communication offers the resistance of porcine plasminogen to activation by t-PA as an explanation. Porcine blood containing 100 and 1500 IU/ml added t-PA lysed very slowly, having LY30 values of 1.9 +/- 1.4 and 2.9 +/- 1.9%, respectively. In contrast, the LY30 values for the human clots containing 100 and 1500 IU/ml t-PA were 77.1 +/- 6.3 and 93.3 +/- 1.3%, respectively. Moreover, purified porcine plasminogen was activated very slowly by added t-PA in the presence of both human and porcine fibrin. Activation of plasminogen by the endogenous activators, as measured by the euglobulin clot lysis time, was greatly prolonged for the pig (22 +/- 3 h) compared with the human (3.5 +/- 1.5 h). These results suggest caution in using the pig as an experimental model when studying the effects of various agents on fibrinolysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In emergency situations, where time for blood transfusion is reduced, the O negative blood type (the universal donor) is administrated. However, sometimes even the universal donor can cause transfusion reactions that can be fatal to the patient. As commercial systems do not allow fast results and are not suitable for emergency situations, this paper presents the steps considered for the development and validation of a prototype, able to determine blood type compatibilities, even in emergency situations. Thus it is possible, using the developed system, to administer a compatible blood type, since the first blood unit transfused. In order to increase the system’s reliability, this prototype uses different approaches to classify blood types, the first of which is based on Decision Trees and the second one based on support vector machines. The features used to evaluate these classifiers are the standard deviation values, histogram, Histogram of Oriented Gradients and fast Fourier transform, computed on different regions of interest. The main characteristics of the presented prototype are small size, lightweight, easy transportation, ease of use, fast results, high reliability and low cost. These features are perfectly suited for emergency scenarios, where the prototype is expected to be used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This multi-modal investigation aimed to refine analytic tools including proton magnetic resonance spectroscopy (1H-MRS) and fatty acid gas chromatography-mass spectrometry (GC-MS) analysis, for use with adult and paediatric populations, to investigate potential biochemical underpinnings of cognition (Chapter 1). Essential fatty acids (EFAs) are vital for the normal development and function of neural cells. There is increasing evidence of behavioural impairments arising from dietary deprivation of EFAs and their long-chain fatty acid metabolites (Chapter 2). Paediatric liver disease was used as a deficiency model to examine the relationships between EFA status and cognitive outcomes. Age-appropriate Wechsler assessments measured Full-scale IQ (FSIQ) and Information Processing Speed (IPS) in clinical and healthy cohorts; GC-MS quantified surrogate markers of EFA status in erythrocyte membranes; and 1H-MRS quantified neurometabolite markers of neuronal viability and function in cortical tissue (Chapter 3). Post-transplant children with early-onset liver disease demonstrated specific deficits in IPS compared to age-matched acute liver failure transplant patients and sibling controls, suggesting that the time-course of the illness is a key factor (Chapter 4). No signs of EFA deficiency were observed in the clinical cohort, suggesting that EFA metabolism was not significantly impacted by liver disease. A strong, negative correlation was observed between omega-6 fatty acids and FSIQ, independent of disease diagnosis (Chapter 5). In a study of healthy adults, effect sizes for the relationship between 1H-MRS- detectable neurometabolites and cognition fell within the range of previous work, but were not statistically significant. Based on these findings, recommendations are made emphasising the need for hypothesis-driven enquiry and greater subtlety of data analysis (Chapter 6). Consistency of metabolite values between paediatric clinical cohorts and controls indicate normal neurodevelopment, but the lack of normative, age-matched data makes it difficult to assess the true strength of liver disease-associated metabolite changes (Chapter 7). Converging methods offer a challenging but promising and novel approach to exploring brain-behaviour relationships from micro- to macroscopic levels of analysis (Chapter 8).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To explore views of patients with type 2 diabetes about self monitoring of blood glucose over time. Design: Longitudinal, qualitative study. Setting: Primary and secondary care settings across Lothian, Scotland. Participants: 18 patients with type 2 diabetes. Main outcome measures: Results from repeat in-depth interviews with patients over four years after clinical diagnosis. Results: Analysis revealed three main themes - the role of health professionals, interpreting readings and managing high values, and the ongoing role of blood glucose self monitoring. Self monitoring decreased over time, and health professionals' behaviour seemed crucial in this: participants interpreted doctors' focus on levels of haemoglobin A1c, and lack of perceived interest in meter readings, as indicating that self monitoring was not worth continuing. Some participants saw readings as a proxy measure of good and bad behaviour - with women especially, chastising themselves when readings were high. Some participants continued to find readings difficult to interpret, with uncertainty about how to respond to high readings. Reassurance and habit were key reasons for continuing. There was little indication that participants were using self monitoring to effect and maintain behaviour change. Conclusions: Clinical uncertainty about the efficacy and role of blood glucose self monitoring in patients with type 2 diabetes is mirrored in patients' own accounts. Patients tended not to act on their self monitoring results, in part because of a lack of education about the appropriate response to readings. Health professionals should be explicit about whether and when such patients should self monitor and how they should interpret and act upon the results, especially high readings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To characterize the population pharmacokinetics of canrenone following administration of potassium canrenoate (K-canrenoate) in paediatric patients. Methods: Data were collected prospectively from 37 paediatric patients (median weight 2.9 kg, age range 2 days–0.85 years) who received intravenous K-canrenoate for management of retained fluids, for example in heart failure and chronic lung disease. Dried blood spot (DBS) samples (n = 213) from these were analysed for canrenone content and the data subjected to pharmacokinetic analysis using nonlinear mixed-effects modelling. Another group of patients (n = 16) who had 71 matching plasma and DBS samples was analysed separately to compare canrenone pharmacokinetic parameters obtained using the two different matrices. Results: A one-compartment model best described the DBS data. Significant covariates were weight, postmenstrual age (PMA) and gestational age. The final population models for canrenone clearance (CL/F) and volume of distribution (V/F) in DBS were CL/F (l/h) = 12.86 ×  (WT/70.0)0.75 × e [0.066 ×  (PMA - 40]) and V/F (l) = 603.30 ×  (WT/70) × (GA/40)1.89 where weight is in kilograms. The corresponding values of CL/F and V/F in a patient with a median weight of 2.9 kg are 1.11 l/h and 20.48 l, respectively. Estimated half-life of canrenone based on DBS concentrations was similar to that based on matched plasma concentrations (19.99 and 19.37 h, respectively, in 70 kg patient). Conclusion: The range of estimated CL/F in DBS for the study population was 0.12–9.62 l/h; hence, bodyweight-based dosage adjustment of K-canrenoate appears necessary. However, a dosing scheme that takes into consideration both weight and age (PMA/gestational age) of paediatric patients seems more appropriate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An increasing number of publications on the dried blood spot (DBS) sampling approach for the quantification of drugs and metabolites have been spurred on by the inherent advantages of this sampling technique. In the present research, a selective and sensitive high-performance liquid chromatography method for the concurrent determination of multiple antiepileptic drugs (AEDs) [levetiracetam (LVT), lamotrigine (LTG), phenobarbital (PHB)], carbamazepine (CBZ) and its active metabolite carbamazepine-10,11 epoxide (CBZE)] in a single DBS has been developed and validated. Whole blood was spotted onto Guthrie cards and dried. Using a standard punch (6 mm diameter), a circular disc was punched from the card and extracted with methanol: acetonitrile (3:1, v/v) containing hexobarbital (Internal Standard) and sonicated prior to evaporation. The extract was then dissolved in water and vortex mixed before undergoing solid phase extraction using HLB cartridges. Chromatographic separation of the AEDs was achieved using Waters XBridge™ C18 column with a gradient system. The developed method was linear over the concentration ranges studied with r ≥ 0.995 for all compounds. The lower limits of quantification (LLOQs) were 2, 1, 2, 0.5 and 1 μg/mL for LVT, LTG, PHB, CBZE and CBZ, respectively. Accuracy (%RE) and precision (%CV) values for within and between day were <20% at the LLOQs and <15% at all other concentrations tested. This method was successfully applied to the analysis of the AEDs in DBS samples taken from children with epilepsy for the assessment of their adherence to prescribed treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate OneTouch® Verio™ test strip performance at hypoglycaemic blood glucose (BG) levels (<3.9mmol/L [<70mg/dL]) at seven clinical studies. Methods: Trained clinical staff performed duplicate capillary BG monitoring system tests on 700 individuals with type 1 and type 2 diabetes using blood from a single fingerstick lancing. BG reference values were obtained using a YSI 2300 STAT™ Glucose Analyzer. The number and percentage of BG values within ±0.83. mmol/L (±15. mg/dL) and ±0.56. mmol/L (±10. mg/dL) were calculated at BG concentrations of <3.9. mmol/L (<70. mg/dL), <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL). Results: At BG concentrations <3.9. mmol/L (<70. mg/dL), 674/674 (100%) of meter results were within ±0.83. mmol/L (±15. mg/dL) and 666/674 (98.8%) were within ±0.56. mmol/L (±10. mg/dL) of reference values. At BG concentrations <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL), 358/358 (100%) and 270/270 (100%) were within ±0.56. mmol/L (±10. mg/dL) of reference values, respectively. Conclusion: In this analysis of data from seven independent studies, OneTouch Verio test strips provide highly accurate results at hypoglycaemic BG levels. © 2012 Elsevier Ireland Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluorescence spectroscopy has recently become more common in clinical medicine. However, there are still many unresolved issues related to the methodology and implementation of instruments with this technology. In this study, we aimed to assess individual variability of fluorescence parameters of endogenous markers (NADH, FAD, etc.) measured by fluorescent spectroscopy (FS) in situ and to analyse the factors that lead to a significant scatter of results. Most studied fluorophores have an acceptable scatter of values (mostly up to 30%) for diagnostic purposes. Here we provide evidence that the level of blood volume in tissue impacts FS data with a significant inverse correlation. The distribution function of the fluorescence intensity and the fluorescent contrast coefficient values are a function of the normal distribution for most of the studied fluorophores and the redox ratio. The effects of various physiological (different content of skin melanin) and technical (characteristics of optical filters) factors on the measurement results were additionally studied.The data on the variability of the measurement results in FS should be considered when interpreting the diagnostic parameters, as well as when developing new algorithms for data processing and FS devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation evaluated the feasibility of using commercially available immortalized cell lines in building a tissue engineered in vitro blood-brain barrier (BBB) co-culture model for preliminary drug development studies. Mouse endothelial cell line and rat astrocyte cell lines purchased from American Type Culture Collections (ATCC) were the building blocks of the co-culture model. An astrocyte derived acellular extracellular matrix (aECM) was introduced in the co-culture model to provide a novel in vitro biomimetic basement membrane for the endothelial cells to form endothelial tight junctions. Trans-endothelial electrical resistance (TEER) and solute mass transport studies were engaged to quantitatively evaluate the tight junction formation on the in-vitro BBB models. Immuno-fluorescence microscopy and Western Blot analysis were used to qualitatively verify the in vitro expression of occludin, one of the earliest discovered tight junction proteins. Experimental data from a total of 12 experiments conclusively showed that the novel BBB in vitro co-culture model with the astrocyte derived aECM (CO+aECM) was promising in terms of establishing tight junction formation represented by TEER values, transport profiles and tight junction protein expression when compared with traditional co-culture (CO) model setups and endothelial cells cultured alone. Experimental data were also found to be comparable with several existing in vitro BBB models built from various methods. In vitro colorimetric sulforhodamine B (SRB) assay revealed that the co-cultured samples with aECM resulted in less cell loss on the basal sides of the insert membranes than that from traditional co-culture samples. The novel tissue engineering approach using immortalized cell lines with the addition of aECM was proven to be a relevant alternative to the traditional BBB in vitro modeling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stable isotope analysis has become a standard ecological tool for elucidating feeding relationships of organisms and determining food web structure and connectivity. There remain important questions concerning rates at which stable isotope values are incorporated into tissues (turnover rates) and the change in isotope value between a tissue and a food source (discrimination values). These gaps in our understanding necessitate experimental studies to adequately interpret field data. Tissue turnover rates and discrimination values vary among species and have been investigated in a broad array of taxa. However, little attention has been paid to ectothermic top predators in this regard. We quantified the turnover rates and discrimination values for three tissues (scutes, red blood cells, and plasma) in American alligators (Alligator mississippiensis). Plasma turned over faster than scutes or red blood cells, but turnover rates of all three tissues were very slow in comparison to those in endothermic species. Alligator δ15N discrimination values were surprisingly low in comparison to those of other top predators and varied between experimental and control alligators. The variability of δ15N discrimination values highlights the difficulties in using δ15N to assign absolute and possibly even relative trophic levels in field studies. Our results suggest that interpreting stable isotope data based on parameter estimates from other species can be problematic and that large ectothermic tetrapod tissues may be characterized by unique stable isotope dynamics relative to species occupying lower trophic levels and endothermic tetrapods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The impact of environmental pollution on the homeostasis of sea turtles remains scarce, particularly in the southern Gulf of Mexico. As many municipalities do not rely on a waste treatment plant along the coastline of the Yucatan Peninsula, the vulnerability of these specimens could results enhanced. We searched for relationships between presence of organochlorine pesticides (OCP) and the level of several oxidative and pollutant stress indicators of the hawksbill sea turtle (Eretmochelys imbricata) during the egg-laying period 2010 at Punta Xen (Campeche, Mexico). Endosulfans, aldrin related (aldrin, endrin, dieldrin, endrin ketone, endrin aldehyde) and dichlorodiphenyldichloroethylene (DDT) families were detected in 17, 21 and 26 of the 30 sampled sea turtles, respectively. Significant correlation existed between the size of sea turtles with the concentration of methoxychlor, cholinesterase activity in plasma and heptachlors family, and catalase activity and hexachlorohexane family. Cholinesterase activity in washed erythrocytes and lipid peroxidation were positively correlated with glutathione reductase activity. Antioxidant enzyme actions seem adequate as no lipids damages were correlated with any OCPs. Future studies are necessary to evaluate the effect of OCPs on males of the area because of the significant detection of methoxychlor that target endocrine functioning and increase its concentration with size of the sea turtles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine the haematological value and biochemical blood in baby alpacas with enteric disorder. A total of 30 blood and serum samples were collected from alpacas of 1 month old with diarrhoea and 5 blood samples of clinically healthy baby alpacas (controls). The animals were from communities in the central Andes from Peru. About haematology were determined haematocrit, haemoglobin concentration, red blood count and white blood count that were not significantly different between control animals and animals with diarrhoea. Moreover, biochemical blood parameters as total protein, albumin and calcium decrease significantly (p<0.05). We conclude that our results could be considered as factors in the mortality of baby alpaca by infectious diarrhoea.