955 resultados para VP latex


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The bulk free radical copolymerization of 2-hydroxyethyl methacrylate (HEMA) with N-vinyl-2-pyrrolidone (VP) was carried out to low conversions at 50 degreesC, using benzoyl peroxide (BPO) as initiator. The compositions of the copolymers; were determined using C-13 NMR spectroscopy. The conversion of monomers to polymers was studied using FT-NIR spectroscopy in order to predict the extent of conversion of monomer to polymer. From model fits to the composition data, a statistical F-test revealed that die penultimate model describes die copolymerization better than die terminal model. Reactivity ratios were calculated by using a non-linear least squares analysis (NLLS) and r(H) = 8.18 and r(V) = 0.097 were found to be the best fit values of the reactivity ratios for the terminal model and r(HH) = 12.0, r(VH) = 2.20, r(VV) = 0.12 and r(HV) = 0.03 for the penultimate model. Predictions were made for changes in compositions as a function of conversion based upon the terminal and penultimate models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poly(2-hydroxyethyl methacrylate) and copolymers of 2-hydroxyethyl methacrylate (HEMA) and 1-vinyl-2-pyrrolidone (VP) in the form of cylindrical samples (approximate to8mm x 20mm) have been prepared and the sorption of water into these cylinders has been studied by the mass-uptake methods and by magnetic-resonance imaging. The equilibrium water contents for the cylinders were found to vary systematically with the copolymer composition. Diffusion of water into the cylinders was found to follow Fickian behaviour for cylinders with high HEMA contents, with the diffusion coefficients obtained from mass-uptake studies dependent on the copolymer composition, varying from 1.7 x 10(-11) m(2) s(-1) for poly(HEMA) to 2.0 x 10(-11) m(2) s(-1) for poly(HEMA-co-VP) with a composition of 1:1. However, NMR-imaging studies showed that, while the profiles of the water diffusion fronts for cylinders with high HEMA contents were Fickian, that for the 1:1 copolymer was not and indicated that the mechanism was Case III. The polymers which were rich in VP were characterized by a water-sorption process which follows Case-III behaviour. (C) 2003 Society of Chemical Industry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

É crescente o mercado de flores tropicais no Brasil. No nordeste, por causa do clima, torna-se difícil a aclimatização dessas plantas. Portanto, este trabalho tem por objetivo determinar o recipiente mais adequado para aclimatizar mudas micropropagadas de bastão do imperador cv. Porcelana, em ambiente protegido. O experimento foi realizado em estufa e as mudas utilizadas foram obtidas por micropropagação. O delineamento experimental utilizado foi de blocos ao acaso, com quatro tratamentos (volumes) e cinco repetições. Os volumes dos recipientes testados foram: V1 - 50 cm³ (Copo pequeno - CP); V2 - 150 cm³ (Tubete pequeno - TP); V3 - 300 cm³ (Tubete grande - TG); V4 - 450 cm³(Vaso pequeno - VP). Foram coletados dados correspondentes ao número de folhas (NF), altura da muda (AM), diâmetro do pseudocaule (DP), massa fresca da parte aérea (MFPA), massa fresca do sistema radicular (MFSR), massa seca da parte aérea (MSPA) e massa seca do sistema radicular (MSSR). Foi realizada a análise de variância e os resultados de natureza qualitativa foram submetidos ao teste de média. O vaso de 450 cm³ é o recipiente mais adequado para aclimatização de bastão do imperador, pois proporcionou melhor desenvolvimento das mudas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seismic recordings of IRIS/IDA/GSN station CMLA and of several temporary stations in the Azores archipelago are processed with P and S receiver function (PRF and SRF) techniques. Contrary to regional seismic tomography these methods provide estimates of the absolute velocities and of the Vp/Vs ratio up to a depth of similar to 300 km. Joint inversion of PRFs and SRFs for a few data sets consistently reveals a division of the subsurface medium into four zones with a distinctly different Vp/Vs ratio: the crust similar to 20 km thick with a ratio of similar to 1.9 in the lower crust, the high-Vs mantle lid with a strongly reduced VpNs velocity ratio relative to the standard 1.8, the low-velocity zone (LVZ) with a velocity ratio of similar to 2.0, and the underlying upper-mantle layer with a standard velocity ratio. Our estimates of crustal thickness greatly exceed previous estimates (similar to 10 km). The base of the high-Vs lid (the Gutenberg discontinuity) is at a depth of-SO km. The LVZ with a reduction of S velocity of similar to 15% relative to the standard (IASP91) model is terminated at a depth of similar to 200 km. The average thickness of the mantle transition zone (TZ) is evaluated from the time difference between the S410p and SKS660p, seismic phases that are robustly detected in the S and SKS receiver functions. This thickness is practically similar to the standard IASP91 value of 250 km. and is characteristic of a large region of the North Atlantic outside the Azores plateau. Our data are indicative of a reduction of the S-wave velocity of several percent relative to the standard velocity in a depth interval from 460 to 500 km. This reduction is found in the nearest vicinities of the Azores, in the region sampled by the PRFs, but, as evidenced by SRFs, it is missing at a distance of a few hundred kilometers from the islands. We speculate that this anomaly may correspond to the source of a plume which generated the Azores hotspot. Previously, a low S velocity in this depth range was found with SRF techniques beneath a few other hotspots.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate the crust, upper mantle and mantle transition zone of the Cape Verde hotspot by using seismic P and S receiver functions from several tens of local seismograph stations. We find a strong discontinuity at a depth of similar to 10 km underlain by a similar to 15-km thick layer with a high (similar to 1.9) Vp/Vs velocity ratio. We interpret this discontinuity and the underlying layer as the fossil Moho, inherited from the pre-hotspot era, and the plume-related magmatic underplate. Our uppermost-mantle models are very different from those previously obtained for this region: our S velocity is much lower and there are no indications of low densities. Contrary to previously published arguments for the standard transition zone thickness our data indicate that this thickness under the Cape Verde islands is up to similar to 30 km less than in the ambient mantle. This reduction is a combined effect of a depression of the 410-km discontinuity and an uplift of the 660-km discontinuity. The uplift is in contrast to laboratory data and some seismic data on a negligible dependence of depth of the 660-km discontinuity on temperature in hotspots. A large negative pressure-temperature slope which is suggested by our data implies that the 660-km discontinuity may resist passage of the plume. Our data reveal beneath the islands a reduction of S velocity of a few percent between 470-km and 510-km depths. The low velocity layer in the upper transition zone under the Cape Verde archipelago is very similar to that previously found under the Azores and a few other hotspots. In the literature there are reports on a regional 520-km discontinuity, the impedance of which is too large to be explained by the known phase transitions. Our observations suggest that the 520-km discontinuity may present the base of the low-velocity layer in the transition zone. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A saúde em Portugal vive hoje mudanças significativas. A criação de modelos de Gestão Empresarial em instituições públicas visa a melhor qualidade ao menor custo. A aquisição de equipamento médico, cada vez mais sofisticado, exige das instituições esforços redobrados. A necessidade de redução dos custos acoplada à necessidade de aquisição de tecnologias cada vez mais avançadas exige que as instituições tomem mediadas mais rigorosas para melhorar o processo de aquisição. É importante estabelecer desde o início de um processo de aquisição, as exatas necessidades da instituição, com um conjunto de especificações bem detalhado do produto a adquirir bem como um conjunto exigências que devem ser feitas perante os fornecedores que salvaguardem a instituição. O conhecimento do equipamento a adquirir facilita todo o processo. Assim é de extrema importância garantir o estudo bastante alargado do equipamento, permitindo à instituição uma melhor avaliação do equipamento, aquando da seleção do mesmo. A garantia da confiabilidade metrológica é outro ponto muito importante a ter em conta no processo, uma vez que o sucesso dos cuidados de saúde parte da confiança e segurança que transmitem aos seus utentes. O objetivo deste trabalho é o estudo de Ventiladores Pulmonares (VP) focando essencialmente na seleção e aquisição destes equipamentos. Neste estudo faz-se também um estudo dos procedimentos de avaliação da confiabilidade metrológica dos VP, tendo em vista a definição dos testes de verificação a serem efetuados ao longo do processo de aquisição. É normalizado o Caderno de Encargos (CE) e respetivas especificações/requisitos técnicos, tentando comprar de acordo com as reais necessidades da instituição, visando o menor desperdício e garantido a melhor qualidade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Molecularly imprinted polymers (MIP) were used as potentiometric sensors for the selective recognition and determination of chlormequat (CMQ). They were produced after radical polymerization of 4-vinyl pyridine (4-VP) or methacrylic acid (MAA) monomers in the presence of a cross-linker. CMQwas used as template. Similar nonimprinted (NI) polymers (NIP) were produced by removing the template from reaction media. The effect of kind and amount of MIP or NIP sensors on the potentiometric behavior was investigated. Main analytical features were evaluated in steady and flow modes of operation. The sensor MIP/4-VP exhibited the best performance, presenting fast near-Nernstian response for CMQover the concentration range 6.2×10-6 – 1.0×10-2 mol L-1 with detection limits of 4.1×10-6 mol L-1. The sensor was independent from the pH of test solutions in the range 5 – 10. Potentiometric selectivity coefficients of the proposed sensors were evaluated over several inorganic and organic cations. Results pointed out a good selectivity to CMQ. The sensor was applied to the potentiometric determination of CMQin commercial phytopharmaceuticals and spiked water samples. Recoveries ranged 96 to 108.5%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar os serviços do Sistema Único de Saúde brasileiro de assistência ambulatorial a adultos vivendo com aids em 2007 e comparar com a avaliação de 2001. MÉTODOS: Os 636 serviços cadastrados no Ministério da Saúde em 2007 foram convidados a responder a um questionário previamente validado (Questionário Qualiaids) com 107 questões de múltipla escolha sobre a organização da assistência prestada. Analisaram-se as frequências das respostas de 2007 comparando-as com as obtidas em 2001 na forma de variação percentual (VP). RESULTADOS: Responderam o questionário 504 (79,2%) serviços. Cerca de 100,0% dos respondentes relataram ter pelo menos um médico, suprimento sem falhas de antirretrovirais e de exames CD4 e carga viral. Vários aspectos mostraram melhor desempenho em 2007 comparados a 2001: registro de número de faltas à consulta médica (de 18,3 para 27,0%, VP: 47,5%), agendamento de consulta em menos de 15 dias no início da terapia antirretroviral (de 55,3 para 66,2%, VP: 19,7%) e participação organizada do usuário (de 5,9 para 16,7%, VP: 183,1%). Houve manutenção de dificuldades: pequena variação na disponibilidade de exames especializados em até 15 dias, como endoscopia (31,9 para 34,5%, VP: 8,1%), e a piora de indicadores como tempo ideal de acesso a consultas especializadas (55,9 para 34,5% em cardiologia, VP negativa de 38,3%). O tempo médio despendido nas consultas médicas de seguimento manteve-se baixo: 15 minutos ou menos (52,5 para 49,5%, VP negativa de 5,8%). CONCLUSÕES: A avaliação de 2007 mostrou que os serviços contam com os recursos essenciais para a assistência ambulatorial. Houve melhoras em muitos aspectos em relação a 2001, mas persistem desafios. Pouco tempo dedicado à consulta médica pode estar vinculado ao número insuficiente de médicos e/ou à baixa capacidade de escuta e diálogo. A acessibilidade prejudicada a consultas especializadas mostra a dificuldade das infraestruturas locais do Sistema Único de Saúde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – O melanoma maligno cutâneo (MMC) é considerado uma das mais letais neoplasias e no seu seguimento recorre-se, para além dos exames clínicos e da análise de marcadores tumorais, a diversos métodos imagiológicos, como é o exame Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT, do acrónimo inglês Positron Emission Tomography/Computed Tomography) com 18fluor-fluorodeoxiglucose (18F-FDG). O presente estudo tem como objetivo avaliar a utilidade da PET/CT relativamente à análise da extensão e à suspeita de recidiva do MMC, comparando os achados imagiológicos com os descritos em estudos CT. Metodologia – Estudo retrospetivo de 62 estudos PET/CT realizados em 50 pacientes diagnosticados com MMC. Excluiu-se um estudo cujo resultado era duvidoso (nódulo pulmonar). As informações relativas aos resultados dos estudos anatomopatológicos e dos exames imagiológicos foram obtidas através da história clínica e dos relatórios médicos dos estudos CT e PET/CT. Foi criada uma base de dados com os dados recolhidos através do software Excel e foi efetuada uma análise estatística descritiva. Resultados – Dos estudos PET/CT analisados, 31 foram considerados verdadeiros positivos (VP), 28 verdadeiros negativos (VN), um falso positivo (FP) e um falso negativo (FN). A sensibilidade, especificidade, o valor preditivo positivo (VPP), o valor preditivo negativo (VPN) e a exatidão da PET/CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 96,9%, 96,6%, 96,9%, 96,6% e 96,7%. Dos resultados da CT considerados na análise estatística, 14 corresponderam a VP, 12 a VN, três a FP e cinco a FN. A sensibilidade, especificidade, o VPP e o VPN e a exatidão da CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 73,7%, 80,0%, 82,4%, 70,6% e 76,5%. Comparativamente aos resultados CT, a PET/CT permitiu uma mudança na atitude terapêutica em 23% dos estudos. Conclusão – A PET/CT é um exame útil na avaliação do MMC, caracterizando-se por uma maior acuidade diagnóstica no estadiamento e na avaliação de suspeita de recidiva do MMC comparativamente à CT isoladamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Information obtained from the routine application of hydatid immunodiagnostic techniques in different clinical situations over a seven-year period is presented. The Immunoelectrophoresis test was used until it was replaced by the simpler, more sensitive and equally specific arc 5 double diffusion (DD5) test. Examination of sera from 1,888 patients with signs and/or symptoms compatible with hydatid disease revealed that the presurgical confirmation of Echinococcus granulosus infection is only obtained by detection of anti-antigen 5 antibodies. The latter were not found in 1,539 presumptive hydatidosis patients whose definitive diagnoses corresponded to other disease conditions. However, false positive latex agglutination test results were obtained in two cases. In all patients whose preoperative serum showed three or more uncharacteristic bands in the absence of anti-antigen 5 antibodies, hydatid cysts were found sur gically. DD5 testing of a fluid sample collected by puncture established its hydatid etiology. Post-operative monitoring of hydatidosis patients demonstrated that persistence of DD5-positivity two years after surgery established the presence of other cysts. Further evidence was obtained in patients with hydatid cysts in intrathoracic, abdominal or other locations associating cyst membrane integrity, antigen release and immunodiagnostic test positivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have conducted a P and S receiver functions [PRFs and SRFs] analysis for 19 seismic stations on the Iberia and western Mediterranean. In the transition zone [TZ] the PRFs analysis reveals a band [from Gibraltar to Balearic] increased by 10-20 km relative to the standard 250 km. The TZ thickness variations are strongly correlated with the P660s times in PRFs. We interpret the variable depth of the 660-km discontinuity as an effect of subduction. Over the anomalous TZ we found a reduced velocity zone in the upper mantle. Joint inversion of PRFs and SRFs reveals a subcrustal high S velocity lid and an underlying LVZ. A reduction of the S velocity in the LVZ is less than 10%. The Gutenberg discontinuity is located at 65±5 km, but in several models sampling the Mediterranean, the lid is missing or its thickness is reduced to ~30 km. In the Gibraltar and North Africa this boundary is located at ~100 km. The lid Vp/Vs beneath Betics is reduced relative to the standard 1.8. Another evidence of the Vp/Vs anomaly is provided by S410p phase late arrivals in the SRFs. The azimuthal anisotropy analysis with a new technology was conducted at 5 stations and at 2 groups of stations. The fast direction in the uppermost mantle layer is ~90º in Iberian Massif. In Balearic is in the azimuth of ~120º. At a depth of ~60 km the direction becomes 90º. Anisotropy in the upper layer can be interpreted as frozen, whereas anisotropy in the lower layer is active, corresponding to the present-day or recent flow. The effect of the asthenosphere in the SKS splitting is much larger than the effect of the subcrustal lithosphere.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Revista Portuguesa de Cardiologia, 1994, 13(10): 763-768.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Antígeno del polisacárido capsular (Ag PC) de Cryptococcus neoformans fue detectado por la técnica de aglutinación de latex (AL) en LCR y suero de pacientes con Sindrome de Inmunodeficiencia Adquirida (SIDA) y primer episodio de neurocriptococosis, usando como patrón el examen micológico (examen directo y cultivo) de LCR. Se obtuvo una sensibilidad del 100% de AL para detectar AgPC de C. neoformans, el cual por su rápidez permite tratamiento específico precoz. Títulos iniciales de AgPC de la levadura en esos pacientes pueden ser > 1.000.000, pareciendo que cuando esos títulos están presentes en suero, se relacionan con mortalidad durante el tratamiento. En los pacientes que sobrevivieron se observó que el examen micológico directo y AgPC de C. neoformans, en LCR y suero, permanecen positivos aún después de tratamiento y mejoría clínica del paciente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Se normalizó un ultramicroELISA indirecto para la detección de anticuerpos a Citomegalovirus (CMV) humano (UMELISA CMV). Se determinó la concentración óptima de antígeno en 30 ug/ml, la dilución de los sueros fue de 1:40 y la dilución de trabajo del conjugado fue de 1:1500. El UMELISA CMV fue comparado con las técnicas de aglutinación de latex para anticuerpos anti-CMV (Dupont de Neumors) y la inmunofluorescencia indirecta (EFT). Los resultados mostraron un alto grado de concordancia y elevada copositividad y conegatividad del UMELISA con respecto a estos dos ensayos. El método es válido para el pesquisaje de anticuerpos en banco de sangre asi como para el diagnóstico de la infección mediante sueros pareados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The lethal effect of a bait containing an aqueous hexachlorocyclohexane (HCH) suspension at the concentration of 1g/l and maintained at room temperature was studied in the laboratory over a period of 12 weeks. The suspension was placed in a latex bag hanging inside a 1000-ml beaker tightly covered with nylon netting, and left there with no changes for 85 days. Sixteen groups of R. prolixas bugs, consisting on average of 30 specimens each, were successively exposed to the bait and observed at different intervals for one week each. The mortality rate was 100% for all groups, except for the 16th, whose mortality rate was 96.7%. As the groups succeeded one another, mortality started to occur more rapidly and was more marked at the 6- and 24-h intervals. Later tests respectively started at 6:00 a.m. and 6:00 p.m. showed that diurnal and nocturnal periodicity in the offer of food had no effect on mortality. First- and 2nd- instar nymphs and adults male were more sensitive and 5th- instar nymphs were more resistant to the active principle of the bait.