980 resultados para VIDEO-ASSISTED THORACIC SURGERY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report presents a case of acute lung injury developing within hours after administration of mefloquine for a low-level Plasmodium falciparum malaria, which was persistent despite halofantrine therapy. Extensive microbiological investigation remained negative and video-assisted thoracoscopic lung biopsy demonstrated diffuse alveolar damage. The evolution was favourable without treatment. This is the second report of acute lung injury and diffuse alveolar damage caused by mefloquine. Glucose-6-phosphate dehydrogenase deficiency was present in the former case and was thought to contribute to the lung injury. However, glucose-phosphate dehydrogenase was normal in the present case, suggesting that it is not a predisposing condition to the lung injury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The pre-treatment of tumour neovessels by low-level photodynamic therapy (PDT) improves the distribution of concomitantly administered systemic chemotherapy. The mechanism by which PDT permeabilizes the tumour vessel wall is only partially known. We have recently shown that leukocyte-endothelial cell interaction is essential for photodynamic drug delivery to normal tissue. The present study investigates whether PDT enhances drug delivery in malignant mesothelioma and whether it involves comparable mechanisms of actions. METHODS: Human mesothelioma xenografts (H-meso-1) were grown in the dorsal skinfold chambers of 28 nude mice. By intravital microscopy, the rolling and recruitment of leukocytes were assessed in tumour vessels following PDT (Visudyne(®) 400 μg/kg, fluence rate 200 mW/cm(2) and fluence 60 J/cm(2)) using intravital microscopy. Likewise, the distribution of fluorescently labelled macromolecular dextran (FITC-dextran, MW 2000 kDa) was determined after PDT. Study groups included no PDT, PDT, PDT plus a functionally blocking anti-pan-selectin antibody cocktail and PDT plus isotype control antibody. RESULTS: PDT significantly enhanced the extravascular accumulation of FITC-dextran in mesothelioma xenografts, but not in normal tissue. PDT significantly increased leukocyte-endothelial cell interaction in tumour. While PDT-induced leukocyte recruitment was significantly blunted by the anti-pan-selectin antibodies in the tumour xenograft, this manipulation did not affect the PDT-induced extravasation of FITC-dextran. CONCLUSIONS: Low-level PDT pre-treatment selectively enhances the uptake of systemically circulating macromolecular drugs in malignant mesothelioma, but not in normal tissue. Leukocyte-endothelial cell interaction is not required for PDT-induced drug delivery to malignant mesothelioma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comment on : Results of two different approaches to closure of subaortic ventricular septal defects in children. [Eur J Cardiothorac Surg. 2014]

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is a frequent arrhythmia after conventional coronary artery bypass grafting. With the advent of minimally invasive technique for left internal mammary artery-left anterior descending coronary artery (LIMA-LAD) grafting, we analyzed the incidence and the risk factors of postoperative AF in this patient population. This prospective study involves all patients undergoing isolated LIMA-LAD grafting with minimally invasive technique between January 1994 and June 2000. Twenty-four possible risk factors for postoperative AF were entered into univariate and multivariate logistic regression analyses. Postoperative AF occurred in 21 of the 90 patients (23.3%) analyzed. Double- or triple-vessel disease was present in 12/90 patients (13.3%). On univariate analysis, right coronary artery disease (p <0.01), age (p = 0.01), and diabetes (p = 0.04) were found to be risk factors for AF. On multivariate analysis, right coronary artery disease was identified as the sole significant risk factor (p = 0.02). In this patient population, the incidence of AF after minimally invasive coronary artery bypass is in the range of that reported for conventional coronary artery bypass grafting. Right coronary artery disease was found to be an independent predictor, and this may be related to the fact that in this patient population the diseased right coronary artery was not revascularized at the time of the surgical procedure. For the same reason, this risk factor may find a broader application to noncardiac thoracic surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Sleep disordered breathing with central apnea or hypopnea frequently occurs during sleep at high altitude. The aim of this study was to assess the effects of added dead space (DS) on sleep disordered breathing and transcutaneous CO2 (PtcCO2) level during sleep at high altitude. Methods: Full night sleep recordings were obtained on 12 unacclimatized mountaineers (11 males, 1 female, mean age 39 ± 12 y.o.) during one of the first 4 nights after arrival in Leh, Ladakh (3500 m). In random order, half of the night was spent with a 500 ml increase in dead space through a custom designed full face mask and the other half without it. PtcCO2 was measured in 3 participants. Results: Baseline recordings reveled two clearly distinct groups: one with severe sleep disordered breathing (n = 5) and the other with mild or no disordered breathing (n = 7). Added dead space markedly improved breathing in the first group (baseline vs DS): apnea hypopnea index (AHI) 70.3 ± 25.8 vs 29.4 ± 6.9 (p = 0.013), oxygen desaturation index (ODI): 72.9 ± 24.1/h vs 42.5 ± 14.4 (p = 0.031), whereas it had no significant effect in the second group. Added dead space did not have a significant effect on mean oxygen saturation level. Respiratory events were almost exclusively central apnea or hypopnea except for one subject. Only a minor increase in mean PtcCO2 (n = 3) was observed: 33.6 ± 1.8 mm Hg at baseline and 35.0 ± 2.62 mm Hg with DS. Sleep quality was preserved under dead space condition, since the microarousal rate remained unchanged (16.8 ± 8.7/h vs 19.4 ± 18.6/h (p = 0.51). Conclusion: In mountaineers with severe sleep disordered breathing at high altitude, a 500 ml increase in dead space through a fitted mask significantly improves nocturnal breathing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Use of cardiopulmonary bypass for emergency resuscitation is not new. In fact, John Gibbon proposed this concept for the treatment of severe pulmonary embolism in 1937. Significant progress has been made since, and two main concepts for cardiac assist based on cardiopulmonary bypass have emerged: cardiopulmonary support (CPS) and extracorporeal membrane oxygenation (ECMO). The objective of this review is to summarize the state of the art in these two technologies. METHODS: Configuration of CPS is now fairly standard. A mobile cart with relatively large wheels allowing for easy transportation carries a centrifugal pump, a back-up battery with a charger, an oxygen cylinder, and a small heating system. Percutaneous cannulation, pump-driven venous return, rapid availability, and transportability are the main characteristics of a CPS system. Cardiocirculatory arrest is a major predictor of mortality despite the use of CPS. In contrast, CPS appears to be a powerful tool for patients in cardiogenic shock before cardiocirculatory arrest, requiring some type of therapeutic procedures, especially repair of anatomically correctable problems or bridging to other mechanical circulatory support systems such as ventricular assist devices. CPS is in general not suitable for long-term applications because of the small-bore cannulas, resulting in significant pressure gradients and eventually hemolysis. RESULTS: In contrast, ECMO can be designed for longer-term circulatory support. This requires large-bore cannulas and specifically designed oxygenators. The latter are either plasma leakage resistent (true membranes) or relatively thrombo-resistant (heparin coated). Both technologies require oxygenator changeovers although the main reason for this is different (clotting for the former, plasma leakage for the latter). Likewise, the tubing within a roller pump has to be displaced and centrifugal pump heads have to be replaced over time. ECMO is certainly the first choice for a circulatory support system in the neonatal and pediatric age groups, where the other assist systems are too bulky. ECMO is also indicated for patients improving on CPS. Septic conditions are, in general, considered as contraindications for ECMO. CONCLUSIONS: Ease of availability and moderate cost of cardiopulmonary bypass-based cardiac support technologies have to be balanced against the significant immobilization of human resources, which is required to make them successful.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Benign mature teratomas are the most common type of germ cell tumors that arise in the anterior mediastinum. Intrapericardial teratomas are a rare manifestation of this tumor type, which are generally diagnosed during infancy because of the heart compression symptoms they produce. Here we report a rare case of intrapericardial mature teratoma that was incidentally discovered in an asymptomatic 51-year-old woman.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study is to create a standard test to approve the efficacy of a surgical sealant. An industrial test, the bulge-and-blister test, which is very convenient for measuring adhesion energy, is applied to the surgical field to quantify adhesion of bioadhesives. METHODS: Samples were composed of two circular layers of equine pericardium glued by the surgical sealant studied. The sample was fixed to a support with an industrial glue. The support and the bottom layer were perforated in the centre to allow injection of pressurised water. Water was progressively introduced through the hole in the support and the bottom layer to create a blister with constant radius, increasing height and internal pressure during this first step. At a critical pressure, delamination started, the radius and height of the blister increased and the pressure decreased. At this point, the adhesion energy could be determined. The experimental parameters were measured with a pressure sensor and an optical profilometry device for deflection. RESULTS: Adhesion testing was carried out in eight paired equine pericardium samples bonded with a Dermabond cyanoacrylate glue. The average value of the practical adhesion energy is 2.3 Jm(-2) with a standard deviation of 1.5 Jm(-2). CONCLUSION: Application of the bulge-and-blister test to the surgical field was achieved and allowed a quantification of adhesion of a surgical glue. Such information is essential to compare the different surgical glues presently available. The study of the impact of bonding conditions such as pressure, hygrometry or setting conditions will provide a better understanding of the characteristics of adhesion in the surgical field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: All patients with extensive resection of the anterolateral chest wall and the sternum followed by reconstruction with methylmethacrylate substitutes were assessed prospectively 6 months after the operation to delineate chest wall integrity with pulmonary function and cine-magnetic resonance imaging. METHODS: Twenty-six patients underwent chest wall reconstruction by use of methylmethacrylate between 1994 and 1998 due to primary tumors in 35%, metastases in 27%, T3 lung cancer in 19%, and debridement for radionecrosis and osteomyelitis in 19% of patients. Three to eight ribs were resected and additional sternum resection was performed in 39% of patients. RESULTS: There was no 30-day mortality. All patients were extubated after the operation without need for reintubation. Prosthesis dislocation occurred in 1 patient and infection in 2 patients during follow-up. Nineteen patients (73%) suffered no restrictions of daily activities. Clinical examination revealed normal shoulder girdle function in 77% of patients. There was no significant difference between preoperative and postoperative FEV1 (forced expiratory volume in 1 second) measurements in patients with lobectomy or wedge resections. Cinemagnetic resonance imaging revealed concordant chest wall movements during respiration in 92% of patients without paradoxical movements or implant dislocations being observed. CONCLUSIONS: Large defects of the anterolateral chest wall and sternum can be reconstructed efficiently with methylmethacrylate substitutes with minimal morbidity and excellent cosmetic and functional outcome.