846 resultados para Using an harmonic instrument


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. PATIENTS AND METHODS: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. RESULTS: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to < o =0.3 mm. CONCLUSIONS: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Methods. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. Results. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7mmHgand-0.9+/- 0.5mmHg, respectively), withameanpulsepressureof3.4mmHg.ThedifferencebetweenthemeanCVPandCVPatend-diastoleduringexpirationwas0.58+/- 0.81 mmHg. Conclusions. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this single-center study was to report our initial experience with an implantable remote pressure sensor for aneurysm sac pressure measurement in patients post-endovascular aneurysm repair (EVAR) including short-term follow-up. A pressure sensor (EndoSure, Atlanta, GA) was implanted in 12 patients treated with different commercially available aortic endografts for EVAR. Pressure was read pre- and post-EVAR in the operating room. One-month follow-up (30 days +/- 6 days) was performed including sac pressure readings and IV contrast CT scans. Variables were compared using the paired Student's t test. An intraprocedure type-I endoleak and a type-III endoleak were successfully treated resulting in decreasing sac pressures. In all patients, post-EVAR systolic sac pressure decreased by an average of 33% (P ans, the average maximum aneurysm diameter pre-EVAR was 6.3 +/- 1.6 cm and post-EVAR 6.0 +/- 1.7 cm (Paneurysm sac was larger only in one patient with a type-III endoleak. Remote sac pressure measurement may provide important information in addition to imaging and may help to reduce the number of follow-up CT scans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To report the efficacy of percutaneous treatment of an orbital venous malformation with an electrolytically detachable fibred coil. METHODS: We report an instance of radiography-guided percutaneous treatment with an electrolytically detachable fibred coil in a 16-year-old boy with acute, spontaneous, painless proptosis on the left side, which progressed with time. RESULTS: Magnetic resonance imaging, angiography and orbitophlebography revealed a low-flow, intraorbital venous malformation. Percutaneous puncture and drainage were followed by a short remission. Following an acute recurrence, a single detachable fibred coil was deployed via a percutaneous approach under angiographic guidance. No radiological or clinical recurrences were observed over 4 years. CONCLUSIONS: Embolization of a deep orbital venous malformation with detachable fibred coils via a percutaneous approach can be highly effective, and may be considered before proceeding with open surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare objective fellow and expert efficiency indices for an interventional radiology renal artery stenosis skill set with the use of a high-fidelity simulator. MATERIALS AND METHODS: The Mentice VIST simulator was used for three different renal artery stenosis simulations of varying difficulty, which were used to grade performance. Fellows' indices at three intervals throughout 1 year were compared to expert baseline performance. Seventy-four simulated procedures were performed, 63 of which were captured as audiovisual recordings. Three levels of fellow experience were analyzed: 1, 6, and 12 months of dedicated interventional radiology fellowship. The recordings were compiled on a computer workstation and analyzed. Distinct measurable events in the procedures were identified with task analysis, and data regarding efficiency were extracted. Total scores were calculated as the product of procedure time, fluoroscopy time, tools, and contrast agent volume. The lowest scores, which reflected efficient use of tools, radiation, and time, were considered to indicate proficiency. Subjective analysis of participants' procedural errors was not included in this analysis. RESULTS: Fellows' mean scores diminished from 1 month to 12 months (42,960 at 1 month, 18,726 at 6 months, and 9,636 at 12 months). The experts' mean score was 4,660. In addition, the range of variance in score diminished with increasing experience (from a range of 5,940-120,156 at 1 month to 2,436-85,272 at 6 months and 2,160-32,400 at 12 months). Expert scores ranged from 1,450 to 10,800. CONCLUSIONS: Objective efficiency indices for simulated procedures can demonstrate scores directly comparable to the level of clinical experience.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The GLAaS algorithm for pretreatment intensity modulation radiation therapy absolute dose verification based on the use of amorphous silicon detectors, as described in Nicolini et al. [G. Nicolini, A. Fogliata, E. Vanetti, A. Clivio, and L. Cozzi, Med. Phys. 33, 2839-2851 (2006)], was tested under a variety of experimental conditions to investigate its robustness, the possibility of using it in different clinics and its performance. GLAaS was therefore tested on a low-energy Varian Clinac (6 MV) equipped with an amorphous silicon Portal Vision PV-aS500 with electronic readout IAS2 and on a high-energy Clinac (6 and 15 MV) equipped with a PV-aS1000 and IAS3 electronics. Tests were performed for three calibration conditions: A: adding buildup on the top of the cassette such that SDD-SSD = d(max) and comparing measurements with corresponding doses computed at d(max), B: without adding any buildup on the top of the cassette and considering only the intrinsic water-equivalent thickness of the electronic portal imaging devices device (0.8 cm), and C: without adding any buildup on the top of the cassette but comparing measurements against doses computed at d(max). This procedure is similar to that usually applied when in vivo dosimetry is performed with solid state diodes without sufficient buildup material. Quantitatively, the gamma index (gamma), as described by Low et al. [D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, Med. Phys. 25, 656-660 (1998)], was assessed. The gamma index was computed for a distance to agreement (DTA) of 3 mm. The dose difference deltaD was considered as 2%, 3%, and 4%. As a measure of the quality of results, the fraction of field area with gamma larger than 1 (%FA) was scored. Results over a set of 50 test samples (including fields from head and neck, breast, prostate, anal canal, and brain cases) and from the long-term routine usage, demonstrated the robustness and stability of GLAaS. In general, the mean values of %FA remain below 3% for deltaD equal or larger than 3%, while they are slightly larger for deltaD = 2% with %FA in the range from 3% to 8%. Since its introduction in routine practice, 1453 fields have been verified with GLAaS at the authors' institute (6 MV beam). Using a DTA of 3 mm and a deltaD of 4% the authors obtained %FA = 0.9 +/- 1.1 for the entire data set while, stratifying according to the dose calculation algorithm, they observed: %FA = 0.7 +/- 0.9 for fields computed with the analytical anisotropic algorithm and %FA = 2.4 +/- 1.3 for pencil-beam based fields with a statistically significant difference between the two groups. If data are stratified according to field splitting, they observed %FA = 0.8 +/- 1.0 for split fields and 1.0 +/- 1.2 for nonsplit fields without any significant difference.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In this paper, we present a new method for the calibration of a microscope and its registration using an active optical tracker. METHODS: Practically, both operations are done simultaneously by moving an active optical marker within the field of view of the two devices. The IR LEDs composing the marker are first segmented from the microscope images. By knowing their corresponding three-dimensional (3D) position in the optical tracker reference system, it is possible to find the transformation matrix between the referential of the two devices. Registration and calibration parameters can be extracted directly from that transformation. In addition, since the zoom and focus can be modified by the surgeon during the operation, we propose a spline based method to update the camera model to the new setup. RESULTS: The proposed technique is currently being used in an augmented reality system for image-guided surgery in the fields of ear, nose and throat (ENT) and craniomaxillofacial surgeries. CONCLUSIONS: The results have proved to be accurate and the technique is a fast, dynamic and reliable way to calibrate and register the two devices in an OR environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In tuberculosis (TB), the risk of exposure is determined mainly by the proximity to and the hours of direct contact with an infectious patient. We describe the contact investigation after detection of an infectious form of TB in a military camp using an Interferon-g-Release-Assay (IGRA, QuantiFERON-TB Gold In Tube [QTF-GIT]) eight weeks after detection of the index case. INDEX PATIENT: The index patient presented with fever, cough and weight loss in the military hospital six weeks after entering the camp. TB was suspected and anti-tuberculous therapy given immediately. Subsequently, TB was microbiologically confirmed. METHODS: Four exposure groups were formed a priori based on the proximity and the hours of direct contact to the index case. 168 (95.5%) agreed to be investigated: - Group A: sharing the same dormitory (15 persons) - Group B: same platoon, but not sharing the dormitory (20 persons) - Group C: staff and patients of the military hospital (22 persons) - Group D: other three platoons and senior military staff (111 persons). RESULTS: 34 (20.2%) out of 168 contacts tested positive in the QFT-GIT assay. For the exposure groups, the respective QFT-GIT testing results were: group A, 14/15 (93%); group B, 4/20 (20%); group C, 5/22 (22.7%); and group D, 11/111 (9.9%). No secondary TB cases were identified. CONCLUSIONS: In our study, test results show a correlation with the risk of exposure, suggesting that IGRA may be useful for the assessment of TB infection in TB contacts. The high mobility of recruits reduced traceability of contacts. In this context, QFT-GIT allowed for an efficient screening of contacts at a single time point.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate whether equine serum amyloid A (SAA) concentrations could be reliably measured in plasma with a turbidimetric immunoassay previously validated for equine SAA concentrations in serum. Paired serum and lithium-heparin samples obtained from 40 horses were evaluated. No difference was found in SAA concentrations between serum and plasma using a paired t test (P=0.48). The correlation between paired samples was 0.97 (Spearman's rank P<0.0001; 95% confidence interval 0.95-0.99). Passing-Bablok regression analyses revealed no differences between paired samples. Bland-Altman plots revealed a positive bias in plasma compared to serum but the difference was not considered clinically significant. The results indicate that lithium-heparin plasma samples are suitable for measurement of equine SAA using this method. Use of either serum or plasma allows for greater flexibility when it comes to sample collection although care should be taken when comparing data between measurements from different sample types.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In cranio-maxillofacial surgery, the determination of a proper surgical plan is an important step to attain a desired aesthetic facial profile and a complete denture closure. In the present paper, we propose an efficient modeling approach to predict the surgical planning on the basis of the desired facial appearance and optimal occlusion. To evaluate the proposed planning approach, the predicted osteotomy plan of six clinical cases that underwent CMF surgery were compared to the real clinical plan. Thereafter, simulated soft-tissue outcomes were compared using the predicted and real clinical plan. This preliminary retrospective comparison of both osteotomy planning and facial outlook shows a good agreement and thereby demonstrates the potential application of the proposed approach in cranio-maxillofacial surgical planning prediction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the main problems of flood hazard assessment in ungauged or poorly gauged basins is the lack of runoff data. In an attempt to overcome this problem we have combined archival records, dendrogeomorphic time series and instrumental data (daily rainfall and discharge) from four ungauged and poorly gauged mountain basins in Central Spain with the aim of reconstructing and compiling information on 41 flash flood events since the end of the 19th century. Estimation of historical discharge and the incorporation of uncertainty for the at-site and regional flood frequency analysis were performed with an empirical rainfall–runoff assessment as well as stochastic and Bayesian Markov Chain Monte Carlo (MCMC) approaches. Results for each of the ungauged basins include flood frequency, severity, seasonality and triggers (synoptic meteorological situations). The reconstructed data series clearly demonstrates how uncertainty can be reduced by including historical information, but also points to the considerable influence of different approaches on quantile estimation. This uncertainty should be taken into account when these data are used for flood risk management.