878 resultados para Unified User Experience Model
Resumo:
Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques
Resumo:
Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques.
Resumo:
Theory building is one of the most crucial challenges faced by basic, clinical and population research, which form the scientific foundations of health practices in contemporary societies. The objective of the study is to propose a Unified Theory of Health-Disease as a conceptual tool for modeling health-disease-care in the light of complexity approaches. With this aim, the epistemological basis of theoretical work in the health field and concepts related to complexity theory as concerned to health problems are discussed. Secondly, the concepts of model-object, multi-planes of occurrence, modes of health and disease-illness-sickness complex are introduced and integrated into a unified theoretical framework. Finally, in the light of recent epistemological developments, the concept of Health-Disease-Care Integrals is updated as a complex reference object fit for modeling health-related processes and phenomena.
Resumo:
The future of health care delivery is becoming more citizen-centred, as today’s user is more active, better informed and more demanding. The European Commission is promoting online health services and, therefore, member states will need to boost deployment and use of online services. This makes e-health adoption an important field to be studied and understood. This study applied the extended unified theory of acceptance and usage technology (UTAUT2) to explain patients’ individual adoption of e-health. An online questionnaire was administrated Portugal using mostly the same instrument used in UTAUT2 adapted to e-health context. We collected 386 valid answers. Performance expectancy, effort expectancy, social influence, and habit had the most significant explanatory power over behavioural intention and habit and behavioural intention over technology use. The model explained 52% of the variance in behavioural intention and 32% of the variance in technology use. Our research helps to understand the desired technology characteristics of ehealth. By testing an information technology acceptance model, we are able to determine what is more valued by patients when it comes to deciding whether to adopt e-health systems or not.
Resumo:
Tese de Doutoramento em Tecnologias e Sistemas de Informação
Resumo:
The treatment of back pain patients refers to the biopsychosocial model of care. This model includes illness in patient's personal and relational life. In this context, it is not only the physical symptom of the patient which is focused but also his psychological distress often hidden by algic complain. Clinical interviews conducted with back pain patients have highlighted psychosocial aspects able to influence the relationship between health care user and provider. Taking account of psychosocial aspects implies an interdisciplinary approach that identify and assesses patients' needs through adequate tools. As a result, the different health care providers implied with back pain patients have to collaborate in a structured network.
Resumo:
The optimization of the pilot overhead in single-user wireless fading channels is investigated, and the dependence of this overhead on various system parameters of interest (e.g., fading rate, signal-to-noise ratio) is quantified. The achievable pilot-based spectral efficiency is expanded with respect to the fading rate about the no-fading point, which leads to an accurate order expansion for the pilot overhead. This expansion identifies that the pilot overhead, as well as the spectral efficiency penalty with respect to a reference system with genie-aided CSI (channel state information) at the receiver, depend on the square root of the normalized Doppler frequency. It is also shown that the widely-used block fading model is a special case of more accurate continuous fading models in terms of the achievable pilot-based spectral efficiency. Furthermore, it is established that the overhead optimization for multiantenna systems is effectively the same as for single-antenna systems with the normalized Doppler frequency multiplied by the number of transmit antennas.
Resumo:
BACKGROUND: A device to perform sutureless end-to-side coronary artery anastomosis has been developed by means of stent technology (GraftConnector). The present study assesses the long-term quality of the GraftConnector anastomosis in a sheep model. METHODS: In 8 adult sheep, 40-55 kg in weight, through left anterior thoracotomy, the right internal mammary artery (RIMA) was prepared and connected to the left anterior descending artery (LAD) by means of GraftConnector, on beating heart, without using any stabilizer. Ticlopidine 250 mg/day for anticoagulation for 4 weeks and Aspirin 100 mg/day for 6 months were given. The animals were sacrificed after 6 months and histological examination of anastomoses was carried out after slicing with the connector in situ for morphological analysis. RESULTS: All animals survived at 6 months. All anastomoses were patent and mean luminal width at histology was 1.8 +/- 0.2 mm; mean myotomia hyperplasia thickness was 0.21 +/- 0.1 mm. CONCLUSIONS: Long-term results demonstrate that OPCABGs performed with GraftConnector had 100% patency rate. The mean anastomotic luminal width corresponds to mean LAD's adult sheep diameter. We may speculate that myotomia hyperplasia occurred as a result of local device oversizing.
Resumo:
We report on a series of 514 consecutive diagnoses of skeletal dysplasia made over an 8-year period at a tertiary hospital in Kerala, India. The most common diagnostic groups were dysostosis multiplex group (n = 73) followed by FGFR3 (n = 49) and osteogenesis imperfecta and decreased bone density group (n = 41). Molecular confirmation was obtained in 109 cases. Clinical and radiographic evaluation was obtained in close diagnostic collaboration with expert groups abroad through Internet communication for difficult cases. This has allowed for targeted biochemical and molecular studies leading to the correct identification of rare or novel conditions, which has not only helped affected families by allowing for improved genetic counseling and prenatal diagnosis but also resulted in several scientific contributions. We conclude that (1) the spectrum of genetic bone disease in Kerala, India, is similar to that of other parts of the world, but recessive entities may be more frequent because of widespread consanguinity; (2) prenatal detection of skeletal dysplasias remains relatively rare because of limited access to expert prenatal ultrasound facilities; (3) because of the low accessibility to molecular tests, precise clinical-radiographic phenotyping remains the mainstay of diagnosis and counseling and of gatekeeping to efficient laboratory testing; (4) good phenotyping allows, a significant contribution to the recognition and characterization of novel entities. We suggest that the tight collaboration between a local reference center with dedicated personnel and expert diagnostic networks may be a proficient model to bring current diagnostics to developing countries. © 2014 Wiley Periodicals, Inc.