943 resultados para Umbilical Arteries
Resumo:
PURPOSE The aim of this present study was to evaluate the sonographic correlation between Doppler flow characteristics of the uterine arteries and tumor size in patients with cervical cancer, in order to establish a new potential marker to monitor treatment response. METHODS This was a retrospective cohort study of 25 patients who underwent a sonographic evaluation of Doppler flow characteristics of the uterine arteries before surgery or radiochemotherapy for early and locally advanced/advanced cervical cancer, respectively, was analyzed. The primary outcome was the correlation between Doppler flow characteristics of the uterine arteries and tumor size in patients with cervical cancer. RESULTS Median age was 49 (range 26-85) years, and mean tumor size was 40.8 ± 17 mm. A significant positive correlation was found between tumor diameter and the uterine artery end-diastolic velocity (r = 0.47, p < 0.05) as well as the peak systolic velocity (r = 0.41, p < 0.05). No correlation was found between tumor size and the pulsatility index or resistance index. CONCLUSIONS In cervical cancer, uterine artery velocity parameters are associated with tumor size. This finding could become particularly useful in the follow-up of locally advanced cervical cancer patients undergoing radiochemotherapy or in corroborating the selection of women with more possibility of a high response rate during neoadjuvant chemotherapy before surgery.
Resumo:
According to the World Health Organization, 15 million people suffer stroke worldwide each year, of these, 5 million die and 5 million are permanently disabled. Stroke is therefore a major cause of mortality world-wide. The majority of strokes are caused by a blood clot that occludes an artery in the brain, and although thrombolytic agents such as Alteplase are used to dissolve clots that arise in the arteries of the brain, there are limitations on the use of these thrombolytic agents. However over the past decade, other methods of treatment have been developed which include Thrombectomy Devices e.g. the 'GP' Thrombus Aspiration Device ('GP' TAD). Such devices may be used as an alternative to thrombolytics or in conjunction with them to extract blood clots in arteries such as the middle cerebral artery of the midbrain brain, and the posterior inferior cerebellar artery (PICA) of the posterior aspect of the brain. In this paper, we mathematically model the removal of blood clots using the 'GP' TAD from selected arteries of the brain where blood clots may arise taking into account factors such as the resistances, compliances and inertances effects. Such mathematical modelling may have potential uses in predicting the pressures necessary to extract blood clots of given lengths, and masses from arteries in the Circle of Willis - posterior circulation of the brain
Resumo:
Through progress in medical imaging, image analysis and finite element (FE) meshing tools it is now possible to extract patient-specific geometries from medical images of abdominal aortic aneurysms(AAAs), and thus to study clinically-relevant problems via FE simulations. Such simulations allow additional insight into human physiology in both healthy and diseased states. Medical imaging is most often performed in vivo, and hence the reconstructed model geometry in the problem of interest will represent the in vivo state, e.g., the AAA at physiological blood pressure. However, classical continuum mechanics and FE methods assume that constitutive models and the corresponding simulations begin from an unloaded, stress-free reference condition.
Resumo:
The objective of the current work is to present the results of several numerical simulations of pulsatile blood flow in healthy and diseased arteries and compare with clinical expectations. Different realistic and physiological aspects such as blood flow interaction with arterial walls, effect of heart movement, cardiovascular autoregulation, arterial walls' hyperelasticity and cardiovascular disorders have been incorporated in the models thanks to a direct coupling of Abaqus and STAR-CCM+. Comparisons of implicit and explicit coupling methods in cardiovascular simulations have been discussed. An in-house methodology combined with explicit FSI coupling has reduced considerably calculation time while the simulations stay realistic and reliable for clinicians
Resumo:
In pre-surgery decisions in hospital emergency cases, fast and reliable results of the solid and fluid mechanics problems are of great interest to clinicians. In the current investigation, an iterative process based on a pressure-type boundary condition is proposed in order to reduce the computational costs of blood flow simulations in arteries, without losing control of the important clinical parameters. The incorporation of cardiovascular autoregulation, together with the well-known impedance boundary condition, forms the basis of the proposed methodology. With autoregulation, the instabilities associated with conventional pressure-type or impedance boundary conditions are avoided without an excessive increase in computational costs. The general behaviour of pulsatile blood flow in arteries, which is important from the clinical point of view, is well reproduced through this new methodology. In addition, the interaction between the blood and the arterial walls occurs via a modified weak coupling, which makes the simulation more stable and computationally efficient. Based on in vitro experiments, the hyperelastic behaviour of the wall is characterised and modelled. The applications and benefits of the proposed pressure-type boundary condition are shown in a model of an idealised aortic arch with and without an ascending aorta dissection, which is a common cardiovascular disorder.
Resumo:
Nitric oxide (NO), synthesized from l-arginine by NO synthases (NOS), plays an essential role in the regulation of cerebrovascular tone. Adenoviral vectors have been widely used to transfer recombinant genes to different vascular beds. To determine whether the recombinant endothelial NOS (eNOS) gene can be delivered in vivo to the adventitia of cerebral arteries and functionally expressed, a replication-incompetent adenoviral vector encoding eNOS gene (AdCMVNOS) or β-galactosidase reporter gene (AdCMVLacZ) was injected into canine cerebrospinal fluid (CSF) via the cisterna magna (final viral titer in CSF, 109 pfu/ml). Adventitial transgene expression was demonstrated 24 h later by β-galactosidase histochemistry and quantification, eNOS immunohistochemistry, and Western blot analysis of recombinant eNOS. Electron microscopy immunogold labeling indicated that recombinant eNOS protein was expressed in adventitial fibroblasts. In AdCMVNOS-transduced arteries, basal cGMP production and bradykinin-induced relaxations were significantly augmented when compared with AdCMVLacZ-transduced vessels (P < 0.05). The increased receptor-mediated relaxations and cGMP production were inhibited by eNOS inhibitors. In addition, the increase in cGMP production was reversed in the absence of calcium, suggesting that the increased NO production did not result from inducible NOS expression. The present study demonstrates the successful in vivo transfer and functional expression of recombinant eNOS gene in large cerebral arteries. It also suggests that perivascular eNOS gene delivery via the CSF is a feasible approach that does not require interruption of cerebral blood flow.