986 resultados para Triple Frequency Combination


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eigen-based techniques and other monolithic approaches to face recognition have long been a cornerstone in the face recognition community due to the high dimensionality of face images. Eigen-face techniques provide minimal reconstruction error and limit high-frequency content while linear discriminant-based techniques (fisher-faces) allow the construction of subspaces which preserve discriminatory information. This paper presents a frequency decomposition approach for improved face recognition performance utilising three well-known techniques: Wavelets; Gabor / Log-Gabor; and the Discrete Cosine Transform. Experimentation illustrates that frequency domain partitioning prior to dimensionality reduction increases the information available for classification and greatly increases face recognition performance for both eigen-face and fisher-face approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a novel hybrid approach is presented that uses a combination of both time domain and frequency domain solution strategies to predict the power distribution within a lossy medium loaded within a waveguide. The problem of determining the electromagnetic fields evolving within the waveguide and the lossy medium is decoupled into two components, one for computing the fields in the waveguide including a coarse representation of the medium (the exterior problem) and one for a detailed resolution of the lossy medium (the interior problem). A previously documented cell-centred Maxwell’s equations numerical solver can be used to resolve the exterior problem accurately in the time domain. Thereafter the discrete Fourier transform can be applied to the computed field data around the interface of the medium to estimate the frequency domain boundary condition in-formation that is needed for closure of the interior problem. Since only the electric fields are required to compute the power distribution generated within the lossy medium, the interior problem can be resolved efficiently using the Helmholtz equation. A consistent cell-centred finite-volume method is then used to discretise this equation on a fine mesh and the underlying large, sparse, complex matrix system is solved for the required electric field using the iterative Krylov subspace based GMRES iterative solver. It will be shown that the hybrid solution methodology works well when a single frequency is considered in the evaluation of the Helmholtz equation in a single mode waveguide. A restriction of the scheme is that the material needs to be sufficiently lossy, so that any penetrating waves in the material are absorbed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Activated protein C resistance (APCR), the most common risk factor for venous thrombosis, is the result of a G to A base substitution at nucleotide 1691 (R506Q) in the factor V gene. Current techniques to detect the factor V Leiden mutation, such as determination of restriction length polymorphisms, do not have the capacity to screen large numbers of samples in a rapid, cost- effective test. The aim of this study was to apply the first nucleotide change (FNC) technology, to the detection of the factor V Leiden mutation. After preliminary amplification of genomic DNA by polymerase chain reaction (PCR), an allele-specific primer was hybridised to the PCR product and extended using fluorescent terminating dideoxynucleotides which were detected by colorimetric assay. Using this ELISA-based assay, the prevalence of the factor V Leiden mutation was determined in an Australian blood donor population (n = 500). A total of 18 heterozygotes were identified (3.6%) and all of these were confirmed with conventional MnlI restriction digest. No homozygotes for the variant allele were detected. We conclude from this study that the frequency of 3.6% is compatible with others published for Caucasian populations. In addition, the FNC technology shows promise as the basis for a rapid, automated DNA based test for factor V Leiden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decoupling networks can alleviate the effects of mutual coupling in antenna arrays. Conventional decoupling networks can provide decoupled and matched ports at a single frequency. This paper describes dual-frequency decoupling which is achieved by using a network of series or parallel resonant circuits instead of single reactive elements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flood flow in urbanised areas constitutes a major hazard to the population and infrastructure as seen during the summer 2010-2011 floods in Queensland (Australia). Flood flows in urban environments have been studied relatively recently, although no study considered the impact of turbulence in the flow. During the 12-13 January 2011 flood of the Brisbane River, some turbulence measurements were conducted in an inundated urban environment in Gardens Point Road next to Brisbane's central business district (CBD) at relatively high frequency (50 Hz). The properties of the sediment flood deposits were characterised and the acoustic Doppler velocimeter unit was calibrated to obtain both instantaneous velocity components and suspended sediment concentration in the same sampling volume with the same temporal resolution. While the flow motion in Gardens Point Road was subcritical, the water elevations and velocities fluctuated with a distinctive period between 50 and 80 s. The low frequency fluctuations were linked with some local topographic effects: i.e, some local choke induced by an upstream constriction between stairwells caused some slow oscillations with a period close to the natural sloshing period of the car park. The instantaneous velocity data were analysed using a triple decomposition, and the same triple decomposition was applied to the water depth, velocity flux, suspended sediment concentration and suspended sediment flux data. The velocity fluctuation data showed a large energy component in the slow fluctuation range. For the first two tests at z = 0.35 m, the turbulence data suggested some isotropy. At z = 0.083 m, on the other hand, the findings indicated some flow anisotropy. The suspended sediment concentration (SSC) data presented a general trend with increasing SSC for decreasing water depth. During a test (T4), some long -period oscillations were observed with a period about 18 minutes. The cause of these oscillations remains unknown to the authors. The last test (T5) took place in very shallow waters and high suspended sediment concentrations. It is suggested that the flow in the car park was disconnected from the main channel. Overall the flow conditions at the sampling sites corresponded to a specific momentum between 0.2 to 0.4 m2 which would be near the upper end of the scale for safe evacuation of individuals in flooded areas. But the authors do not believe the evacuation of individuals in Gardens Point Road would have been safe because of the intense water surges and flow turbulence. More generally any criterion for safe evacuation solely based upon the flow velocity, water depth or specific momentum cannot account for the hazards caused by the flow turbulence, water depth fluctuations and water surges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the timing of mutations in BRAF (v-raf murine sarcoma viral oncogene homolog B1) during melanocytic neoplasia, we carried out mutation analysis on microdissected melanoma and nevi samples. We observed mutations resulting in the V599E amino-acid substitution in 41 of 60 (68%) melanoma metastases, 4 of 5 (80%) primary melanomas and, unexpectedly, in 63 of 77 (82%) nevi. These data suggest that mutational activation of the RAS/RAF/MAPK pathway in nevi is a critical step in the initiation of melanocytic neoplasia but alone is insufficient for melanoma tumorigenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microwave heating technology is a cost-effective alternative way for heating and curing of used in polymer processing of various alternate materials. The work presented in this paper addresses the attempts made by the authors to study the glass transition temperature and curing of materials such as casting resins R2512, R2515 and laminating resin GPR 2516 in combination with two hardeners ADH 2403 and ADH 2409. The magnetron microwave generator used in this research is operating at a frequency of 2.45 GHz with a hollow rectangular waveguide. During this investigation it has been noted that microwave heated mould materials resulted with higher glass transition temperatures and better microstructure. It also noted that Microwave curing resulted in a shorter curing time to reach the maximum percentage cure. From this study it can be concluded that microwave technology can be efficiently and effectively used to cure new generation alternate polymer materials for manufacture of injection moulds in a rapid and efficient manner. Microwave curing resulted in a shorter curing time to reach the maximum percentage cure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Road traffic injuries are a major global public health problem but continue to receive inadequate attention. Alcohol influences both risk and consequence of road traffic injury but the scale of the problem is not well understood in many countries. In Vietnam, economic development has brought a substantial increase in the number of registered motorcycles as well as alcohol consumption. Traffic injury is among the leading causes of death in Vietnam but there is little local information regarding alcohol related traffic injuries. The primary goal of this study is to explore the drinking and driving patterns of males and their perceptions towards drink-driving and to determine the relationship between alcohol consumption and road traffic injuries. Furthermore, this thesis aims to present the situation analysis for choosing priority actions to reduce drinking and driving in Vietnam. The study is a combination of two cross-sectional surveys and a pilot study. The pilot study, involving 224 traffic injured patients, was conducted to test the tools and the feasibility of approach methods. In the first survey, male patrons (n=464) were randomly selected at seven restaurants. Face-to-face interviews were conducted when patrons just arrived and breath tests were collected when they were about to leave the restaurant. In the second survey, male patients admitted to hospital following a traffic injury (n=480, of which 414 were motorcycle or bicycle riders) were interviewed and their blood alcohol concentration (BAC) measured by breathalyzer. The results show broadly similar patterns of drinking and driving among male patrons and male traffic injured patients with a high frequency of drinking and drink-driving reported among the majority of the two groups. A high proportion of male patrons were leaving restaurants with a BAC over the legal limit. Factors that significantly associate with the number of drinks and BAC were age, hazardous drinking, frequency of drink-driving in the past year, self-estimated number of drinks consumed to drive legally, perceived family’s disapproval of drink-driving, and perceived legal risk and physical risk. The proportion of patrons and patients with BAC above the legal limit of 0.05 were 86.7% and 60.4% respectively, which was much higher than found in previous studies. In addition, both groups had a high prevalence of BAC over 0.15g/100ml (39.7% of patrons and 45.6% patients), a level that can seriously affect driving capacity. Results from the case-crossover analysis for patients indicate a dose-response relationship between alcohol consumption and the risk of traffic injury. The risk of traffic injury increased when alcohol was consumed before driving and there was a more than 13 fold increase when six or more drinks were consumed. Regarding perceptions towards drinking and driving, findings corroborate the low awareness among males in Vietnam, with a majority of respondents holding a low knowledge of safe and legally permissible alcohol use, and a low perceived risk of drinking and driving. The results also indicate a huge gap in prevention skills in terms of planning ahead or using alternative transport to avoid drink-driving and a perception by patrons and patients of a low rate of disapproval of drink-driving from peers and family. Findings in this study have considerable implications for national policy, injury prevention, clinical practice, reporting systems, and for further research. The low rate of compliance with existing laws and a generally low perceived legal risk toward drink-driving in this study call for the strengthening of enforcement along with mass media campaigns and news coverage in order to decrease the widespread perception of impunity and thereby, to reduce the level of drink-driving. In addition, no significant difference was found in this study on risk of traffic injuries between car drivers and motorcycle drivers. The current inconsistency between legal BAC for drivers of motorcycles, compared to cars, thus needs addressing. Furthermore, as drinking was found to be very common, rather than solely targeting drink-driving, it is important to call for a more strategic and comprehensive approach to alcohol policy in Viet Nam. This study also has considerable implications for clinical practice in terms of screening and brief interventions. Our study suggests that the short form of the AUDIT (AUDIT-C) screening tool is appropriate for use in busy emergency departments. The high proportion of traffic injured patients with evidence of alcohol abuse or hazardous drinking suggests that brief interventions by alcohol and drug counselors in emergency departments are a sensible option to addressing this important problem. The significance of this study is in the combination of the systematic collection of breath test and use of case-crossover design to estimate the risk of traffic injuries after alcohol consumption. The results provide convincing evidence to policy makers, health authorities and the media to help raise community awareness and policy advocacy toward the drinkdriving problem in Vietnam. The findings suggest an urgent need for a multi-sectoral approach to curtail drink-driving in Vietnam, especially programs to raise community awareness and effective legal enforcement. Furthermore, serving as a situation analysis, the thesis should inform the formulation of interventions designed to curtail drinking and driving in Vietnam and other developing countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Bioimpedance techniques provide a reliable method of assessing unilateral lymphedema in a clinical setting. Bioimpedance devices are traditionally used to assess body composition at a current frequency of 50 kHz. However, these devices are not transferable to the assessment of lymphedema, as the sensitivity of measuring the impedance of extracellular fluid is frequency dependent. It has previously been shown that the best frequency to detect extracellular fluid is 0 kHz (or DC). However, measurement at this frequency is not possible in practice due to the high skin impedance at DC, and an estimate is usually determined from low frequency measurements. This study investigated the efficacy of various low frequency ranges for the detection of lymphedema. Methods and Results: Limb impedance was measured at 256 frequencies between 3 kHz and 1000 kHz for a sample control population, arm lymphedema population, and leg lymphedema population. Limb impedance was measured using the ImpediMed SFB7 and ImpediMed L-Dex® U400 with equipotential electrode placement on the wrists and ankles. The contralateral limb impedance ratio for arms and legs was used to calculate a lymphedema index (L-Dex) at each measurement frequency. The standard deviation of the limb impedance ratio in a healthy control population has been shown to increase with frequency for both the arm and leg. Box and whisker plots of the spread of the control and lymphedema populations show that there exists good differentiation between the arm and leg L-Dex measured for lymphedema subjects and the arm and leg L-Dex measured for control subjects up to a frequency of about 30 kHz. Conclusions: It can be concluded that impedance measurements above a frequency of 30 kHz decrease sensitivity to extracellular fluid and are not reliable for early detection of lymphedema.