846 resultados para Tracking errors
Resumo:
This paper examines a dataset that derives from an observational tracking, in order to analyze where and how middle-class working families spend time at home. We use an ethnographic approach to study the everyday lives of Italian dual-income middle-class families, with the aim to analyze quantitatively the use of home spaces and the types of activities of family members on weekday afternoons and evenings. The different analyses (multiple correspondence analysis, agglomerative hierarchical cluster, discriminant analysis) show how particular spaces and activities in these spaces are dominated by certain family members. We suggest a combination of qualitative and quantitative methodologies as useful tools to explore in detail the everyday lives of families, and to understand how family members use the domestic spaces. In particular, we consider relevant the use of quantitative analyses to examine ethnographic data, especially in connection with the methodological reflexivity among researchers
Resumo:
Introduction: Neuronal oscillations have been the focus of increasing interest in the neuroscientific community, in part because they have been considered as a possible integrating mechanism through which internal states can influence stimulus processing in a top-down way (Engel et al., 2001). Moreover, increasing evidence indicates that oscillations in different frequency bands interact with one other through coupling mechanisms (Jensen and Colgin, 2007). The existence and the importance of these cross-frequency couplings during various tasks have been verified by recent studies (Canolty et al., 2006; Lakatos et al., 2007). In this study, we measure the strength and directionality of two types of couplings - phase-amplitude couplings and phase-phase couplings - between various bands in EEG data recorded during an illusory contour experiment that were identified using a recently-proposed adaptive frequency tracking algorithm (Van Zaen et al., 2010). Methods: The data used in this study have been taken from a previously published study examining the spatiotemporal mechanisms of illusory contour processing (Murray et al., 2002). The EEG in the present study were from a subset of nine subjects. Each stimulus was composed of 'pac-man' inducers presented in two orientations: IC, when an illusory contour was present, and NC, when no contour could be detected. The signals recorded by the electrodes P2, P4, P6, PO4 and PO6 were averaged, and filtered into the following bands: 4-8Hz, 8-12Hz, 15-25Hz, 35-45Hz, 45-55Hz, 55-65Hz and 65-75Hz. An adaptive frequency tracking algorithm (Van Zaen et al., 2010) was then applied in each band in order to extract the main oscillation and estimate its frequency. This additional step ensures that clean phase information is obtained when taking the Hilbert transform. The frequency estimated by the tracker was averaged over sliding windows and then used to compare the two conditions. Two types of cross-frequency couplings were considered: phase-amplitude couplings and phase-phase couplings. Both types were measured with the phase locking value (PLV, Lachaux et al., 1999) over sliding windows. The phase-amplitude couplings were computed with the phase of the low frequency oscillation and the phase of the amplitude of the high frequency one. Different coupling coefficients were used when measuring phase-phase couplings in order to estimate different m:n synchronizations (4:3, 3:2, 2:1, 3:1, 4:1, 5:1, 6:1, 7:1, 8:1 and 9:1) and to take into account the frequency differences across bands. Moreover, the direction of coupling was estimated with a directionality index (Bahraminasab et al., 2008). Finally, the two conditions IC and NC were compared with ANOVAs with 'subject' as a random effect and 'condition' as a fixed effect. Before computing the statistical tests, the PLV values were transformed into approximately normal variables (Penny et al., 2008). Results: When comparing the mean estimated frequency across conditions, a significant difference was found only in the 4-8Hz band, such that the frequency within this band was significantly higher for IC than NC stimuli starting at ~250ms post-stimulus onset (Fig. 1; solid line shows IC and dashed line NC). Significant differences in phase-amplitude couplings were obtained only when the 4-8 Hz band was taken as the low frequency band. Moreover, in all significant situations, the coupling strength is higher for the NC than IC condition. An example of significant difference between conditions is shown in Fig. 2 for the phase-amplitude coupling between the 4-8Hz and 55-65Hz bands (p-value in top panel and mean PLV values in the bottom panel). A decrease in coupling strength was observed shortly after stimulus onset for both conditions and was greater for the condition IC. This phenomenon was observed with all other frequency bands. The results obtained for the phase-phase couplings were more complex. As for the phase-amplitude couplings, all significant differences were obtained when the 4-8Hz band was considered as the low frequency band. The stimulus condition exhibiting the higher coupling strength depended on the ratio of the coupling coefficients. When this ratio was small, the IC condition exhibited the higher phase-phase coupling strength. When this ratio was large, the NC condition exhibited the higher coupling strength. Fig. 3 shows the phase-phase couplings between the 4-8Hz and 35-45Hz bands for the coupling coefficient 6:1, and the coupling strength was significantly higher for the IC than NC condition. By contrast, for the coupling coefficient 9:1 the NC condition gave the higher coupling strength (Fig. 4). Control analyses verified that it is not a consequence of the frequency difference between the two conditions in the 4-8Hz band. The directionality measures indicated a transfer of information from the low frequency components towards the high frequency ones. Conclusions: Adaptive tracking is a feasible method for EEG analyses, revealing information both about stimulus-related differences and coupling patterns across frequencies. Theta oscillations play a central role in illusory shape processing and more generally in visual processing. The presence vs. absence of illusory shapes was paralleled by faster theta oscillations. Phase-amplitude couplings were decreased more for IC than NC and might be due to a resetting mechanism. The complex patterns in phase-phase coupling between theta and beta/gamma suggest that the contribution of these oscillations to visual binding and stimulus processing are not as straightforward as conventionally held. Causality analyses further suggest that theta oscillations drive beta/gamma oscillations (see also Schroeder and Lakatos, 2009). The present findings highlight the need for applying more sophisticated signal analyses in order to establish a fuller understanding of the functional role of neural oscillations.
Resumo:
Several methods and approaches for measuring parameters to determine fecal sources of pollution in water have been developed in recent years. No single microbial or chemical parameter has proved sufficient to determine the source of fecal pollution. Combinations of parameters involving at least one discriminating indicator and one universal fecal indicator offer the most promising solutions for qualitative and quantitative analyses. The universal (nondiscriminating) fecal indicator provides quantitative information regarding the fecal load. The discriminating indicator contributes to the identification of a specific source. The relative values of the parameters derived from both kinds of indicators could provide information regarding the contribution to the total fecal load from each origin. It is also essential that both parameters characteristically persist in the environment for similar periods. Numerical analysis, such as inductive learning methods, could be used to select the most suitable and the lowest number of parameters to develop predictive models. These combinations of parameters provide information on factors affecting the models, such as dilution, specific types of animal source, persistence of microbial tracers, and complex mixtures from different sources. The combined use of the enumeration of somatic coliphages and the enumeration of Bacteroides-phages using different host specific strains (one from humans and another from pigs), both selected using the suggested approach, provides a feasible model for quantitative and qualitative analyses of fecal source identification.
Resumo:
According to molecular epidemiology theory, two isolates belong to the same chain of transmission if they are similar according to a highly discriminatory molecular typing method. This has been demonstrated in outbreaks, but is rarely studied in endemic situations. Person-to-person transmission cannot be established when isolates of meticillin-resistant Staphylococcus aureus (MRSA) belong to endemically predominant genotypes. By contrast, isolates of infrequent genotypes might be more suitable for epidemiological tracking. The objective of the present study was to determine, in newly identified patients harbouring non-predominant MRSA genotypes, whether putative epidemiological links inferred from molecular typing could replace classical epidemiology in the context of a regional surveillance programme. MRSA genotypes were defined using double-locus sequence typing (DLST) combining clfB and spa genes. A total of 1,268 non-repetitive MRSA isolates recovered between 2005 and 2006 in Western Switzerland were typed: 897 isolates (71%) belonged to four predominant genotypes, 231 (18%) to 55 non-predominant genotypes, and 140 (11%) were unique. Obvious epidemiological links were found in only 106/231 (46%) patients carrying isolates with non-predominant genotypes suggesting that molecular surveillance identified twice as many clusters as those that may have been suspected with classical epidemiological links. However, not all of these molecular clusters represented person-to-person transmission. Thus, molecular typing cannot replace classical epidemiology but is complementary. A prospective surveillance of MRSA genotypes could help to target epidemiological tracking in order to recognise new risk factors in hospital and community settings, or emergence of new epidemic clones.
Resumo:
PURPOSE: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction. MATERIALS AND METHODS: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images. RESULTS: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs. CONCLUSION: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging.
Resumo:
Magnetic resonance angiography (MRA) provides a noninvasive means to detect the presence, location and severity of atherosclerosis throughout the vascular system. In such studies, and especially those in the coronary arteries, the vessel luminal area is typically measured at multiple cross-sectional locations along the course of the artery. The advent of fast volumetric imaging techniques covering proximal to mid segments of coronary arteries necessitates automatic analysis tools requiring minimal manual interactions to robustly measure cross-sectional area along the three-dimensional track of the arteries in under-sampled and non-isotropic datasets. In this work, we present a modular approach based on level set methods to track the vessel centerline, segment the vessel boundaries, and measure transversal area using two user-selected endpoints in each coronary of interest. Arterial area and vessel length are measured using our method and compared to the standard Soap-Bubble reformatting and analysis tool in in-vivo non-contrast enhanced coronary MRA images.
Resumo:
This article reports on a lossless data hiding scheme for digital images where the data hiding capacity is either determined by minimum acceptable subjective quality or by the demanded capacity. In the proposed method data is hidden within the image prediction errors, where the most well-known prediction algorithms such as the median edge detector (MED), gradient adjacent prediction (GAP) and Jiang prediction are tested for this purpose. In this method, first the histogram of the prediction errors of images are computed and then based on the required capacity or desired image quality, the prediction error values of frequencies larger than this capacity are shifted. The empty space created by such a shift is used for embedding the data. Experimental results show distinct superiority of the image prediction error histogram over the conventional image histogram itself, due to much narrower spectrum of the former over the latter. We have also devised an adaptive method for hiding data, where subjective quality is traded for data hiding capacity. Here the positive and negative error values are chosen such that the sum of their frequencies on the histogram is just above the given capacity or above a certain quality.
Resumo:
In a system where tens of thousands of words are made up of a limited number of phonemes, many words are bound to sound alike. This similarity of the words in the lexicon as characterized by phonological neighbourhood density (PhND) has been shown to affect speed and accuracy of word comprehension and production. Whereas there is a consensus about the interfering nature of neighbourhood effects in comprehension, the language production literature offers a more contradictory picture with mainly facilitatory but also interfering effects reported on word production. Here we report both of these two types of effects in the same study. Multiple regression mixed models analyses were conducted on PhND effects on errors produced in a naming task by a group of 21 participants with aphasia. These participants produced more formal errors (interfering effect) for words in dense phonological neighbourhoods, but produced fewer nonwords and semantic errors (a facilitatory effect) with increasing density. In order to investigate the nature of these opposite effects of PhND, we further analysed a subset of formal errors and nonword errors by distinguishing errors differing on a single phoneme from the target (corresponding to the definition of phonological neighbours) from those differing on two or more phonemes. This analysis confirmed that only formal errors that were phonological neighbours of the target increased in dense neighbourhoods, while all other errors decreased. Based on additional observations favouring a lexical origin of these formal errors (they exceeded the probability of producing a real-word error by chance, were of a higher frequency, and preserved the grammatical category of the targets), we suggest that the interfering effect of PhND is due to competition between lexical neighbours and target words in dense neighbourhoods.
Resumo:
The purpose of this bachelor's thesis was to chart scientific research articles to present contributing factors to medication errors done by nurses in a hospital setting, and introduce methods to prevent medication errors. Additionally, international and Finnish research was combined and findings were reflected in relation to the Finnish health care system. Literature review was conducted out of 23 scientific articles. Data was searched systematically from CINAHL, MEDIC and MEDLINE databases, and also manually. Literature was analysed and the findings combined using inductive content analysis. Findings revealed that both organisational and individual factors contributed to medication errors. High workload, communication breakdowns, unsuitable working environment, distractions and interruptions, and similar medication products were identified as organisational factors. Individual factors included nurses' inability to follow protocol, inadequate knowledge of medications and personal qualities of the nurse. Developing and improving the physical environment, error reporting, and medication management protocols were emphasised as methods to prevent medication errors. Investing to the staff's competence and well-being was also identified as a prevention method. The number of Finnish articles was small, and therefore the applicability of the findings to Finland is difficult to assess. However, the findings seem to fit to the Finnish health care system relatively well. Further research is needed to identify those factors that contribute to medication errors in Finland. This is a necessity for the development of methods to prevent medication errors that fit in to the Finnish health care system.
Resumo:
Usingof belt for high precision applications has become appropriate because of the rapid development in motor and drive technology as well as the implementation of timing belts in servo systems. Belt drive systems provide highspeed and acceleration, accurate and repeatable motion with high efficiency, long stroke lengths and low cost. Modeling of a linear belt-drive system and designing its position control are examined in this work. Friction phenomena and position dependent elasticity of the belt are analyzed. Computer simulated results show that the developed model is adequate. The PID control for accurate tracking control and accurate position control is designed and applied to the real test setup. Both the simulation and the experimental results demonstrate that the designed controller meets the specified performance specifications.
Resumo:
Three molecular typing methods (pulsed-field electrophoresis, localization of the mecA gene, and probing the vicinity of mec) have been used for the characterization of 40 catheter-related isolates of coagulase-negative staphylococci (CNS) in 14 patients admitted to the same hospital. The 40 isolates yielded 14 different SmaI banding patterns and corresponding unique localizations of mecA, each associated with a unique ClaI mecA polymorph. In 6 of the 14 patients the contaminated skin at the catheter entry site was the source of 4 local infections and 2 cases of bacteremia. A contaminated hub was the origin of 2 local infections and 4 cases of bacteremia in 6 more patients. The remaining 2 patients had positive cultures from both skin and catheter hub. In each bacteremic patient, the CNS recovered from catheter-related sites (tip, skin, and/or hub) and the CNS recovered from blood were identical, but each of these matching isolates was unique to the particular patient, indicating a low rate of cross-infection from patient to patient. Although classical methods for typing CNS (e.g., biotype and antibiotype) are readily available for most hospital laboratories, they have limitations concerning reproducibility and discriminatory power. Molecular epidemiologic techniques can provide powerful support to traditional techniques in determining the etiologic role of CNS in the disease process
Resumo:
This study is an empirical analysis of the impact of direct tax revenue budgeting errors on fiscal deficits. Using panel data from 26 Swiss cantons between 1980 and 2002, we estimate a single equation model on the fiscal balance, as well as a simultaneous equation model on revenue and expenditure. We use new data on budgeted and actual tax revenue to show that underestimating tax revenue significantly reduces fiscal deficits. Furthermore, we show that this effect is channeled through decreased expenditure. The effects of over and underestimation turn out to be symmetric.
Resumo:
The market place of the twenty-first century will demand that manufacturing assumes a crucial role in a new competitive field. Two potential resources in the area of manufacturing are advanced manufacturing technology (AMT) and empowered employees. Surveys in Finland have shown the need to invest in the new AMT in the Finnish sheet metal industry in the 1990's. In this run the focus has been on hard technology and less attention is paid to the utilization of human resources. In manymanufacturing companies an appreciable portion of the profit within reach is wasted due to poor quality of planning and workmanship. The production flow production error distribution of the sheet metal part based constructions is inspectedin this thesis. The objective of the thesis is to analyze the origins of production errors in the production flow of sheet metal based constructions. Also the employee empowerment is investigated in theory and the meaning of the employee empowerment in reducing the overall production error amount is discussed in this thesis. This study is most relevant to the sheet metal part fabricating industrywhich produces sheet metal part based constructions for electronics and telecommunication industry. This study concentrates on the manufacturing function of a company and is based on a field study carried out in five Finnish case factories. In each studied case factory the most delicate work phases for production errors were detected. It can be assumed that most of the production errors are caused in manually operated work phases and in mass production work phases. However, no common theme in collected production error data for production error distribution in the production flow can be found. Most important finding was still that most of the production errors in each case factory studied belong to the 'human activity based errors-category'. This result indicates that most of the problemsin the production flow are related to employees or work organization. Development activities must therefore be focused to the development of employee skills orto the development of work organization. Employee empowerment gives the right tools and methods to achieve this.
Resumo:
Evaluar una arquitectura de la información en un sitio web ya desplegado no resulta una tarea sencilla. La mayoría de las técnicas se centran en examinar la usabilidad del sistema que, aunque afecta a la arquitectura de la información, no es el único factor que influye en ella. La principal técnica que se utiliza es el test de estrés de navegación. Se muestra un aporte metodológico para hacer dicha técnica más informativa, llevándola más allá de la simple anotación en papel por parte del usuario de respuestas a las preguntas de navegación planteadas. Se propone la combinación de ésta con otras técnicas de evaluación de la usabilidad: la técnica de pensar en voz alta o thinking aloud y un cuestionario de usabilidad. Se ha utilizado un sistema de seguimiento de la mirada o eye tracking para complementar la información obtenida mediante las técnicas aplicadas. El enfoque metodológico planteado se ha puesto a prueba analizando una serie de sitios web de bibliotecas de universidades públicas españolas. Se muestra en los resultados la validez del enfoque empleado, así como el valor que dicho enfoque y el uso del eye tracking aportan al análisis de la arquitectura de la información respecto al test de estrés de navegación tradicional.
Resumo:
We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies.