956 resultados para Torque Arms
Resumo:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Considering the importance of muscle strength to functional capacity in the elderly, the study investigated the effects of age on isokinetic performance and torque production as a function of muscle length. Eleven younger (24.2±2.9years) and seventeen older men (62.7±2.5years) were subjected to concentric and eccentric isokinetic knee extension/flexion at 60°.s-1 and 120°.s-1 through a functional range of motion. The older group presented lower peak torque (Nm) than the young group for both isokinetic contraction types (age effect, p<0.001). Peak torque deficits in the older group were near 30% and 29% for concentric and eccentric contraction, respectively. Concentric peak torque was lower at 120.s-1 than at 60.s-1 for both groups (angular velocity effect, p<0.001). Eccentric knee extension torque was the only exercise tested that showed an interaction effect between age and muscle length (p<0.001), which suggested different torque responses to the muscle length between groups. Compared with the young group, the eccentric knee extension torque was 22% to 56% lower in the older group, with the deficits being lower in the shortened muscle length (22-27%) and higher (33-56%) in stretched muscle length. In older men, the production of eccentric knee strength seems to be muscle length-dependent. At more stretched positions, older subjects lose the capacity to generate eccentric knee extension torque. More studies are needed to assess the mechanisms involved in eccentric strength preservation with aging and its relationship with muscle length.
Resumo:
Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.
Resumo:
Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.
Onset of quadriceps and torque variation in individuals with patellofemoral pain during stair ascent
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objectives: The aim of this study was to evaluate the variation in removal torque of implant prosthetic abutment screws after successive tightening and loosening cycles, in addition to evaluating the influence of the hexagon at the abutment base on screw removal torque. Material and methods: Twenty hexagonal abutments were tightened to 20 regular external hex implants with a titanium alloy screw, with an insertion torque of 32 N cm, measured with a digital torque gauge. The implant/abutment/screw assemblies were divided into two groups: ( 1) abutments without hexagon at the base and ( 2) abutments with a hexagon at the base. Each assembly received a provisional restoration and was submitted to mechanical loading cycles. After this, the screws were removed and the removal torque was measured. This sequence was repeated 10 times, then the screw was replaced by a new one, and another cycle was performed. Linear regression analysis was performed. Results: Removal torque values tended to decrease as the number of insertion/removal cycles increased, for both groups. Comparisons of the slopes and the intercepts between groups showed no statistical difference. There was no significant difference between the mean values of last five cycles and the 11th cycle. Within the limitations of this in vitro study, it was concluded that ( 1) repeated insertion/removal cycles promoted gradual reduction in removal torque of screws, ( 2) replacing the screw with a new one after 10 cycles did not increase resistance to loosening, and ( 3) removal of the hexagon from the abutment base had no effect on the removal torque of the screws.
Resumo:
Introduction: The ankle sprain is one of the most common injuries in athletes. Direct evaluation of the ligament laxity can be obtained through the objective measurement of extreme passive inversion and eversion movements, but there are few studies on the use of the evaluation of the passive resistive torque of the ankle to assess the capsule and ligaments resistance. Objective: The aim of this study was to compare the inversion and eversion passive torque in athletes with and without ankle sprains history. Method: 32 female basketball and volleyball athletes (16.06 +/- 0.8 years old; 67.63 +/- 8.17 kg; 177.8 +/- 6.47 cm) participated in this study. Their ankles were divided into two groups: control group (29), composed of symptom-free ankles, and ankle sprain group, composed of ankles which have suffered injury (29). The resistive torque at maximum passive ankle movement was measured by the isokinetic dynamometer and the muscular activity by electromyography system. The athletes performed 2 repetitions of inversion and eversion movement at 5, 10 and 20 degrees/s and the same protocol only at maximum inversion movement. Results: The resistive passive torque during the inversion and eversion was lower in the ankle sprain group. This group also showed lower torques at the maximum inversion movement. No differences were observed between inversion and eversion movement. Conclusions: Ankle sprain leads to lower passive torque, indicating reduction of the resistance of the lateral ankle ligaments and mechanical laxity.
Resumo:
Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.
Resumo:
This paper presents a method for electromagnetic torque ripple and copper losses reduction in (non-sinusoidal or trapezoidal) surface-mount permanent magnet synchronous machines (SM-PMSM). The method is based on an extension of classical dq transformation that makes it possible to write a vectorial model for this kind of machine (with a non-sinusoidal back-EMF waveform). This model is obtained by the application of that transformation in the classical machine per-phase model. That transformation can be applied to machines that have any type of back-EMF waveform, and not only trapezoidal or square-wave back-EMF waveforms. Implementation results are shown for an electrical converter, using the proposed vectorial model, feeding a non-sinusoidal synchronous machine (brushless DC motor). They show that the use of this vectorial mode is a way to achieve improvements in the performance of this kind of machine, considering the electromagnetic torque ripple and copper losses, if compared to a drive system that employs a classical six-step mode as a converter. Copyright (C) 2011 John Wiley & Sons, Ltd.
Resumo:
Torque teno sus virus (TTSuV) is emergent in swine herds. Recent studies have shown an increased frequency of TTSuV2 in Porcine circovirus type 2 (PCV2)-associated diseases (PCVAD), which are endemic in many swine-producing countries, including Brazil. Coinfection with several other viral and bacterial agents results in an increased incidence of more severe PCVAD. Given the limited information on TTSuV and PCV2 coinfection, especially in Brazilian swine herds, this study made a preliminary estimation of the occurrence of coinfection in swine herds by testing samples from different categories. Between 2008 and 2009, 111 samples of feces and 23 serum samples from 5 swine herds were tested for PCV2 and TTSuVs and the results analyzed for associations between these agents. No significant differences in coinfection frequency were observed for PCV2 1 + TTSuV1 or for PCV2 1 TTSuV2 between nursery piglets (P = 0.730), growing pigs (P = 0.331), or sows (P = 0.472). However, a significant difference was observed for PCV2 1 TTSuV1 1 TTSuV2 between nursery piglets and growing pigs (P = 0.004; Fisher's exact test). Phylogenetic studies agreed with the grouping of TTSuV1 and TTSuV2 into 2 different clades, with no distinct pattern of clustering of these isolates with the animal categories.
Resumo:
Background: High-frequency trains of electrical stimulation applied over the human muscles can generate forces higher than would be expected by direct activation of motor axons, as evidenced by an unexpected relation between the stimuli and the evoked contractions, originating what has been called “extra forces”. This phenomenon has been thought to reflect nonlinear input/output neural properties such as plateau potential activation in motoneurons. However, more recent evidence has indicated that extra forces generated during electrical stimulation are mediated primarily, if not exclusively, by an intrinsic muscle property, and not from a central mechanism as previously thought. Given the inherent differences between electrical and vibratory stimuli, this study aimed to investigate: (a) whether the generation of vibration-induced muscle forces results in an unexpected relation between the stimuli and the evoked contractions (i.e. extra forces generation) and (b) whether these extra forces are accompanied by signs of a centrally-mediated mechanism or whether intrinsic muscle properties are the redominant mechanisms. Methods: Six subjects had their Achilles tendon stimulated by 100 Hz vibratory stimuli that linearly increased in amplitude (with a peak-to-peak displacement varying from 0 to 5 mm) for 10 seconds and then linearly decreased to zero for the next 10 seconds. As a measure of motoneuron excitability taken at different times during the vibratory stimulation, short-latency compound muscle action potentials (V/F-waves) were recorded in the soleus muscle in response to supramaximal nerve stimulation. Results: Plantar flexion torque and soleus V/F-wave amplitudes were increased in the second half of the stimulation in comparison with the first half. Conclusion: The present findings provide evidence that vibratory stimuli may trigger a centrally-mediated mechanism that contributes to the generation of extra torques. The vibration-induced increased motoneuron excitability (leading to increased torque generation) presumably activates spinal motoneurons following the size principle, which is a desirable feature for stimulation paradigms involved in rehabilitation programs and exercise training.