878 resultados para Topographic correction
Resumo:
Semiconductor manufactures are increasing reliant on optical emission spectroscopy (OES) to source information on plasma characteristics and process change. However, nonlinearities in the response of OES sensors and errors in their calibration lead to discrepancies in observed wavelength detector response. This paper presents a technique for the retrospective spectral calibration of multiple OES sensors. Underlying methodology is given, and alignment performance is evaluated using OES recordings from a semiconductor plasma process. The paper concludes with a discussion of results and suggests avenues for future work.
Resumo:
1. The prediction and mapping of climate in areas between climate stations is of increasing importance in ecology.
2. Four categories of model, simple interpolation, thin plate splines, multiple linear regression and mixed spline-regression, were tested for their ability to predict the spatial distribution of temperature on the British mainland. The models were tested by external cross-verification.
3. The British distribution of mean daily temperature was predicted with the greatest accuracy by using a mixed model: a thin plate spline fitted to the surface of the country, after correction of the data by a selection from 16 independent topographical variables (such as altitude, distance from the sea, slope and topographic roughness), chosen by multiple regression from a digital terrain model (DTM) of the country.
4. The next most accurate method was a pure multiple regression model using the DTM. Both regression and thin plate spline models based on a few variables (latitude, longitude and altitude) only were comparatively unsatisfactory, but some rather simple methods of surface interpolation (such as bilinear interpolation after correction to sea level) gave moderately satisfactory results. Differences between the methods seemed to be dependent largely on their ability to model the effect of the sea on land temperatures.
5. Prediction of temperature by the best methods was greater than 95% accurate in all months of the year, as shown by the correlation between the predicted and actual values. The predicted temperatures were calculated at real altitudes, not subject to sea-level correction.
6. A minimum of just over 30 temperature recording stations would generate a satisfactory surface, provided the stations were well spaced.
7. Maps of mean daily temperature, using the best overall methods are provided; further important variables, such as continentality and length of growing season, were also mapped. Many of these are believed to be the first detailed representations at real altitude.
8. The interpolated monthly temperature surfaces are available on disk.
Resumo:
Membrane currents were recorded under voltage clamp from root hairs of Arabidopsis thaliana L. using the two-electrode method. Concurrent measurements of membrane voltage distal to the point of current injection were also carried out to assess the extent of current dissipation along the root hair axis. Estimates of the characteristic cable length, λ, showed this parameter to be a function both of membrane voltage and of substrate concentration for transport. The mean value for λ at 0 mV was 103 ± 20 μm (n=17), but ranged by as much as 6-fold in any one cell for membrane voltages from -300 to +40 mV and was affected by 0.25 to 3-fold at any one voltage on raising [K+]0 from 0.1 to 10 mol m-3. Current dissipation along the length of the cells lead to serious distortions of the current-voltage [I-V) characteristic, including consistent underestimates of membrane current as well as a general linearization of the I-V curve and a masking of conductance changes in the presence of transported substrates. In some experiments, microelectrodes were also placed in neighbouring epidermal cells to record the extent of intercellular coupling. Even with current-passing microelectrodes placed at the base of root hairs, coupling was ≤5% (voltage deflection of the epidermal cell ≤5% that recorded at the site of current injection), indicating an appreciable resistance to current passage between cells. These results demonstrate the feasibility of using root hairs as a 'single-cell model' in electrophysiological analyses of transport across the higher-plant plasma membrane; they also confirmed the need to correct for the cable properties of these cells on a cell-by-cell basis. © 1994 Oxford University Press.
Resumo:
In this paper, we introduce a statistical data-correction framework that aims at improving the DSP system performance in presence of unreliable memories. The proposed signal processing framework implements best-effort error mitigation for signals that are corrupted by defects in unreliable storage arrays using a statistical correction function extracted from the signal statistics, a data-corruption model, and an application-specific cost function. An application example to communication systems demonstrates the efficacy of the proposed approach.
Resumo:
PURPOSE: To quantify the impact on self-reported visual functioning of spectacle provision for school-aged children in Oaxaca, Mexico. METHODS: The Refractive Status Vision Profile (RSVP), a previously validated tool to measure the impact of refractive correction on visual functioning, was adapted for use in rural children and administered at baseline and 4 weeks (27.3 +/- 4.4 days) after the provision of free spectacles. Visual acuity with and without correction, age, sex, and spherical equivalent refraction were recorded at the time of follow-up. RESULTS: Among 88 children (mean age, 12 years; 55.7% girls), the median presenting acuity (uncorrected or with original spectacles), tested 4 weeks after the provision of free spectacles, was 6/9 (range, 6/6-6/120). Significant improvements in the following subscales of the RSVP were seen for the group as a whole after the provision of free spectacles: function, 11.2 points (P = 0.0001); symptoms, 14.3 points (P < 0.0001); total score, 10.3 points (P = 0.0001). After stratification by presenting vision in the better-seeing eye, children with 6/6 acuity (n = 22) did not have significant improvement in any subscale; those with acuity of 6/7.5 to 6/9 (n = 34) improved only on function (P = 0.02), symptoms (P = 0.005), and total score (P = 0.003); and those with acuity of 6/12 or worse improved on total score (P < 0.0001) and all subscales. Subjects (n = 31) with uncorrected myopia of -1.25 D or more had a mean improvement in total score of 15.9 points (P < 0.0001), whereas those with uncorrected myopia between -0.50 and -1.00 D inclusive (n = 53) had a mean improvement of 8 points (P = 0.01). CONCLUSIONS: Provision of spectacles to children in this setting had a significant impact on self-reported function, even at modest levels of baseline visual disability. The correlation between presenting vision/refraction and improvement and the failure of children 6/6 at baseline to improve offer evidence for a real effect.
Resumo:
OBJECTIVE: To compare outcomes between adjustable spectacles and conventional methods for refraction in young people. DESIGN: Cross sectional study. SETTING: Rural southern China. PARTICIPANTS: 648 young people aged 12-18 (mean 14.9 (SD 0.98)), with uncorrected visual acuity ≤ 6/12 in either eye. INTERVENTIONS: All participants underwent self refraction without cycloplegia (paralysis of near focusing ability with topical eye drops), automated refraction without cycloplegia, and subjective refraction by an ophthalmologist with cycloplegia. MAIN OUTCOME MEASURES: Uncorrected and corrected vision, improvement of vision (lines on a chart), and refractive error. RESULTS: Among the participants, 59% (384) were girls, 44% (288) wore spectacles, and 61% (393/648) had 2.00 dioptres or more of myopia in the right eye. All completed self refraction. The proportion with visual acuity ≥ 6/7.5 in the better eye was 5.2% (95% confidence interval 3.6% to 6.9%) for uncorrected vision, 30.2% (25.7% to 34.8%) for currently worn spectacles, 96.9% (95.5% to 98.3%) for self refraction, 98.4% (97.4% to 99.5%) for automated refraction, and 99.1% (98.3% to 99.9%) for subjective refraction (P = 0.033 for self refraction v automated refraction, P = 0.001 for self refraction v subjective refraction). Improvements over uncorrected vision in the better eye with self refraction and subjective refraction were within one line on the eye chart in 98% of participants. In logistic regression models, failure to achieve maximum recorded visual acuity of 6/7.5 in right eyes with self refraction was associated with greater absolute value of myopia/hyperopia (P<0.001), greater astigmatism (P = 0.001), and not having previously worn spectacles (P = 0.002), but not age or sex. Significant inaccuracies in power (≥ 1.00 dioptre) were less common in right eyes with self refraction than with automated refraction (5% v 11%, P<0.001). CONCLUSIONS: Though visual acuity was slightly worse with self refraction than automated or subjective refraction, acuity was excellent in nearly all these young people with inadequately corrected refractive error at baseline. Inaccurate power was less common with self refraction than automated refraction. Self refraction could decrease the requirement for scarce trained personnel, expensive devices, and cycloplegia in children's vision programmes in rural China.
Resumo:
The World Health Organization estimates that 13 million children aged 5-15 years worldwide are visually impaired from uncorrected refractive error. School vision screening programs can identify and treat or refer children with refractive error. We concentrate on the findings of various screening studies and attempt to identify key factors in the success and sustainability of such programs in the developing world. We reviewed original and review articles describing children's vision and refractive error screening programs published in English and listed in PubMed, Medline OVID, Google Scholar, and Oxford University Electronic Resources databases. Data were abstracted on study objective, design, setting, participants, and outcomes, including accuracy of screening, quality of refractive services, barriers to uptake, impact on quality of life, and cost-effectiveness of programs. Inadequately corrected refractive error is an important global cause of visual impairment in childhood. School-based vision screening carried out by teachers and other ancillary personnel may be an effective means of detecting affected children and improving their visual function with spectacles. The need for services and potential impact of school-based programs varies widely between areas, depending on prevalence of refractive error and competing conditions and rates of school attendance. Barriers to acceptance of services include the cost and quality of available refractive care and mistaken beliefs that glasses will harm children's eyes. Further research is needed in areas such as the cost-effectiveness of different screening approaches and impact of education to promote acceptance of spectacle-wear. School vision programs should be integrated into comprehensive efforts to promote healthy children and their families.
Resumo:
Dans le domaine des centres d’appels, l’affectation d’agents au service à la clientèle efficaces et satisfaits représente une activité cruciale pour toute direction dédiée aux ressources humaines de ces unités d’affaires. Or, pour parvenir à prendre de bonnes décisions d’embauche et de rejet, des instruments de mesure et d’évaluation des compétences sont souvent mis à contribution. À cet effet, les tests de jugement situationnel (TJS) sont de plus en plus utilisés pour la sélection du personnel. L’objet de cette thèse est donc de vérifier l’efficacité relative des différentes méthodes d’élaboration des grilles de correction des TJS. En effet, jusqu’à présent, trois méthodes ont été privilégiées par les concepteurs de tests (Weekley, Ployhart, & Holtz, 2006) : (1) l’approche rationnelle ou théorique (2) l’approche empirique et (3) le recours à des experts. La possibilité qu’une combinaison de ces différentes approches puisse conduire à de meilleurs résultats est également explorée. Pour y parvenir, le résultat total obtenu à un TJS a été mis en lien avec une évaluation du rendement global effectuée par un supérieur immédiat en y appliquant huit grilles de correction différentes. Au total, un échantillon de 312 employés œuvrant dans des emplois de téléopérateurs au sein d’une grande institution financière québécoise ont participé à cette recherche. Dans l’ensemble, les résultats indiquent qu’une approche empirique permet généralement d’obtenir de meilleures statistiques descriptives en termes de distribution et de dispersion des scores pour un processus de sélection. Cependant, des analyses corrélationnelles indiquent qu’une approche multiple ou méthode hybride, basée sur une intégration des informations fournies par différentes sources d’informations (empirique, théorique et basé sur les experts) pour l’élaboration d’une grille de correction d’un TJS, permet de mieux prédire le rendement des employés (r=0,247**) comparativement à l’utilisation de la théorie pour définir les attentes (r=0,162**), le recours à des experts de contenu œuvrant dans le domaine de pratique (r=0,164**) ou l’utilisation d’une approche empirique (r=0,154*). Mots clés : Test de jugement situationnel, grilles de correction, validité critériée, centre d’appels.
Resumo:
Tese de mestrado integrado em Engenharia Biomédica e Biofísica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2014