870 resultados para Standard IEEE 1451
Implementação de sistemas de encriptação AES advanced encryption standard em hardware para segurança
Resumo:
Dissertação de mestrado integrado em Engenharia Electrónica Industrial e Computadores
Resumo:
Blood typing is a crucial step before any blood transfusion. However, sometimes in emergency situations there is no time to determine the blood of the patient beforehand. In this cases, O negative blood type is administered, which has a lesser incompatibility risk to the patient. Nowadays, the “gold standard” blood typing devices cannot be used in emergency situations due to their high response time (about 30 minutes). This paper reports a blood typing device that determines the ABO and Rh human phenotypes. This device is fast (response time – 5 min), low-cost, and portable. Characteristics that make it suitable to be used in emergency situations, contributing to a higher efficiency and quality in healthcare.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
As manufacturers face an increasingly competitive environment, they seek out opportunities to reduce production costs without negatively affecting the yield or the quality of their finished products. The challenge of maintaining high product quality while simultaneously reducing production costs can often be met through investments in energy efficient technologies and energy efficiency practices. Energy management systems can offer both technological and best practice efficiencies in order to achieve substantial savings. A strong energy management system provides a solid foundation for an organisation to reduce production costs and improve site efficiency. The I.S EN16001 energy management standard specifies the requirements for establishing, implementing, maintaining and improving an energy management system and represents the latest best practice for energy management in Ireland. The objective of the energy management system is to establish a systematic approach for improving energy performance continuously. The I.S EN16001 standard specifies the requirements for continuous improvement through using energy more efficiently. The author analysed how GlaxoSmithKline’s (GSK) pharmaceutical manufacturing facility in Cork implemented the I.S. EN16001 energy management system model, and defined how energy saving opportunities where identified and introduced to improve efficiency performance. The author performed an extensive literature research in order to determine the current status of the pharmaceutical industry in Ireland, the processes involved in pharmaceutical manufacturing, the energy users required for pharmaceutical manufacturing and the efficiency measures that can be applied to these energy users in order to reduce energy consumption. The author then analysed how energy management standards are introduced to industry and critically analysed the driving factors for energy management performance in Ireland through case studies. Following an investigation as to how the I.S. EN16001 energy management standard is operated in GSK, a critical analysis of the performance achieved by the GSK energy management system is undertaken in order to determine if implementing the I.S EN16001 standard accelerates achieving energy savings. Since its introduction, the I.S. EN16001 model for energy management has enabled GSK to monitor, target and identify energy efficiency opportunities throughout the site. The model has put in place an energy management system that is continuously reviewed for improvement and to date has reduced GSK’s site operations cost by over 30% through technical improvements and generating energy awareness for smarter energy consumption within the GSK Cork site. Investment in I.S. EN16001 has proved to be a sound business strategy for GSK especially in today's manufacturing environment.
Resumo:
v.2 [Crustacea & Insects] (1886)
Resumo:
v.4 [Birds] (1885)
Resumo:
Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.
Resumo:
Gegenstand der hier vorliegenden Arbeit ist die Untersuchung der Auswirkung der MAC-Zugriffsverfahren CSMA/CA auf das Transportschicht-Protokoll in WLAN-Netzen. Zum Erreichen des Ziels dieser Arbeit wurde es zuerst nachgewiesen, dass CSMA/CA zum TCP-Retransmission führen könnte. Dann die kumulative Verteilung der OWDs auf jedem Szena-rio analysiert. Am Ende wurde die kumulative Verteilung der Abstände zwischen den Spitzenwerten der OWD nach der Datenverarbeitung auf jedem Szenario analysiert.
Resumo:
In this paper the construction of Reed-Solomon RS(255,239) codeword is described and the process of coding and decoding a message is simulated and verified. RS(255,239), or its shortened version RS(224,208) is used as a coding technique in Low-Power Single Carrier (LPSC) physical layer, as described in IEEE 802.11ad standard. The encoder takes 239 8-bit information symbols, adds 16 parity symbols and constructs 255-byte codeword to be transmitted through wireless communication channel. RS(255,239) codeword is defined over Galois Field GF and is used for correcting upto 8 symbol errors. RS(255,239) code construction is fully implemented and Simulink test project is constructed for testing and analyzing purposes.
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2015
Resumo:
Estudi realitzat a partir d’una estada al laboratori LSR (Logiciels, Systèmes, Réseaux) – IMAG a Grenoble, França, entre els mesos de setembre del 2005 i febrer del 2006. El grup de recerca Drakkar d’aquest laboratori va desenvolupar un nou mecanisme d’accés al medi per a xarxes d’àrea local sense fils (WLAN) anomenat Idle Sense. S’ha avaluat aquest mecanisme en entorns cel·lulars i s’ha comparat del seu comportament amb l’estàndard IEEE 802.11 DCF mitjançant la implementació en un simulador. En els entorns cel·lulars es troben condicions de transmissió molt allunyades de les ideals, i de les analitzades fins al moment, que consisteixen en escenaris formats per una única cel·la aïllada. Per aquest motiu, primer s’ha estudiat els mecanismes d’accés al medi d’Idle Sense en una cel·la i en condicions de transmissió adverses. Després, s’ha estudiat en entorns multicel·lulars, on les comunicacions entre estacions es veuen influenciades pel problema de solapament de cel·les i per les interferències provocades per les transmissions d’estacions d’altres cel·les. També s’ha comparat els resultats obtinguts amb el comportament d’IEEE 802.11 DCF i d’altres propostes de millora: Asymptotically Optimal Backoff (AOB) i Slow Decrease. Finalment, s’ha realitzat una modificació sobre Idle Sense, que s’ha anomenat Weighted Idle Sense, que resulta més adecuat per a treballar en xarxes d’àrea local sense fils en mode infraestructura.
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
Estudi elaborat a partir d’una estada a la Universität Karlsruhe entre gener i maig del 2007. Les biblioteques d’estructures de dades defineixen interfícies i implementen algorismes i estructures de dades fonamentals. Un exemple n’és la Satandard Template Library (STL ), que forma part del llenguatge de programació C++. En el marc d’una tesi, s’està treballant per obtenir implementacions més eficients i/o versàtils d’alguns components de la STL. Per a fer-ho s’utilitzen tècniques de la enginyeria d’algorismes. En particular, s’integra el coneixement de la comunitat algorítmica i es té en consideració la tecnologia existent. L’acció durant l’estada s’ha emmarcat en el desenvolupament la Multi Core STL (MCSTL ). La MCSTL és una implementació paral•lela de la STL per a màquines multi-core. Les màquines multi-core són actualment l’únic tipus de màquina disponible al mercat. Per tant, tot i que el paral•lelisme obtingut no sigui òptim, és preferible a tenir els processadors esperant, ja que , la tendència és que el nombre de processadors per computador augmenti.
Resumo:
El principal objectiu que es pretén assolir és dissenyar un simulador de la capa MAC, definida a l’estàndard IEEE 802.15.4. Convé matisar que l’objectiu no és implementar un simulador, sinó utilitzar una plataforma genèrica existent, MATLAB, i definir sobre ella, una metodologia que, permeti utilitzar-la més com a plataforma específica de desenvolupament i simulació de protocols per a xarxes de sensors, que no pas com a simple simulador.
Resumo:
A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.