978 resultados para Somatosensory response detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The expression of immune response in the form of leukocytic infiltrate by CD3+, CD4+, and CD8+ cells in the epithelium and in the intestinal lamina propria of chicks was studied in the present work by means of immunohistochemical reaction. The chicks were treated with Lactobacillus spp. or cecal microflora (CM) and experimentally challenged or not with Salmonella enterica serovar Enteritidis. The 320 birds utilized were divided into 4 groups containing 80 chicks each and submitted to treatments with Lactobacillus reuteri, Lactobacillus salivarius, Lactobacillus acidophilus, and CM. Each group was subdivided into 4 subgroups of 20 birds each and classified into a subgroup that did not receive treatment (negative control), subgroup treated, subgroup treated and challenged with Salmonella Enteritidis, and subgroup only challenged with Salmonella Enteritidis (positive control). The results obtained show that the treatment with L. reuteri, L. salivarius, L. acidophilus, or CM and challenged or not with Salmonella Enteritidis determine immune response in the form of leukocytic infiltrate by CD3+ and CD8+ lymphocytes followed by CD4+ in the epithelium and in the lamina propria of the duodenum, jejunum, and cecum of chicks up to 12 d of age. The quantity of CD3+ lymphocytes was significantly higher (P < 0.05) in the intestine of chicks treated with L. acidophilus or CM and challenged or not with Salmonella Enteritidis; however, the higher quantity of CD8+ lymphocytes was in the intestine of chicks treated with CM and challenged with Salmonella Enteritidis. The duodenum was the segment in which the immune response by T cells (CD3+, CD4+, and CD8+) was stimulated with the greatest intensity, followed by, respectively, the jejunum and cecum. The quantity of CD3+ lymphocytes present in the duodenum, jejunum, and cecum increases with the age of chicks, independent of the stimulus determined by treatments or challenge.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The 43,000-molecular-weight (43K) soluble glycoprotein was detected in sera of patients with paracoccidioidomycosis by the immunoblot technique by using as the probe rabbit monospecific antisera to this fraction. The 43K antigen was present before treatment in sera of patients with the acute (juvenile) form; it started to disappear from circulation after 10 months of chemotherapy, and it was undetectable afer 2 years of treatment. In the chronic cases, the 43K antigen was detected in patients without treatment, and it was absent in the healed cases. The detection of the 43K protein specific to Paracoccidioides brasiliensis may be important for its diagnostic value as well as for modulation of the host immune response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sera of patients with paracoccidioidomycosis contained IgG-, IgA-, and IgM-specific antibodies to a 43 kDa antigen contained in the filtrate of a culture of Paracoccidioides brasiliensis. IgG- and IgA-specific antibodies were present in all observed patients. The IgM response was more frequent in acute cases, and the mean titers of IgG- and IgM-specific antibodies were higher in the acute forms. By the fourth month of chemotherapy, there was a decay of IgG, IgA, and IgM antibody titers to this antigen in acute cases, correlating with clinical improvement. The detection of IgG and IgA antibodies and the sequential determination of antibodies to the 43 kDa glycoprotein may be useful tools for serodiagnosis and evaluation of therapeutic efficacy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses the application of a damage detection methodology to monitor the location and extent of partial structural damage. The methodology combines, in an iterative way, the model updating technique based on frequency response functions (FRF) with monitoring data aiming at identifying the damage area of the structure. After the updating procedure reaches a good correlation between the models, it compares the parameters of the damage structure with those of the undamaged one to find the deteriorated area. The influence of the FEM mesh size on the evaluation of the extent of the damage has also been discussed. The methodology is applied using real experimental data from a spatial frame structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The exoantigen of Paracoccidioides brasiliensis standardized by Camargo et al. [1] (AgR) was used to evaluate the in vivo and in vitro cell immune response of experimental animals and of patients with paracoccidioidomycosis (PBM). Fava Netto antigen (AgF) was tested in parallel as a control antigen. The study was conducted with mice and guinea pigs infected with P. brasiliensis or immunized with its fungal antigens, on patients with PBM and on their respective control groups. The cell immune response was analysed by skin tests, and by the macrophage and leucocyte migration inhibition tests (MMIT and LMIT) in the animals and in the patients, respectively. The skin test with AgR as paracoccidioidin was positive in infected or immunized mice and guinea pigs and negative in control animals. The skin tests with AgR (24 h) showed 96.7% positivity in patients with PBM and were negative in control individuals. Histopathological study of the in vivo tests in the different experimental models was consistent with a delayed hypersensitivity response (DHR). Immunohistochemical study of the skin tests of PBM patients demonstrated a predominance of T lymphocytes, confirming the nature of a DHR to the fungal antigens. The in vitro cell immune response showed variable results for the various experimental models, i.e. significant rates of MMIT in immunized mice, a tendency to positivity in infected guinea pigs, and the absence of migration inhibition in PBM patients. Taken together, the data indicate that the AgR is efficient as paracoccidioidin in the evaluation of DHR in PBM, with an optimum time of reading the test of 24 h.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new methodology for soluble oxalic acid determination in grass samples was developed using a two enzyme reactor in an FIA system. The reactor consisted of 3 U of oxalate oxidase and 100 U of peroxidase immobilized on Sorghum vulgare seeds activated with glutaraldehyde. The carbon dioxide was monitored spectrophotometrically, after reacting with an acid-base indicator (Bromocresol Purple) after it permeated through a PTFE membrane. A linear response range was observed between 0.25 and 1.00mmol l-1 of oxalic acid; the data was fit by the equation A=-0.8(±1.5)+ 57.2(±2.5)[oxalate], with a correlation coefficient of 0.9971 and a relative standard deviation of 2% for n=5. The variance for a 0.25 mmol l-1 oxalic acid standard solution was lower than 4% for 11 measurements. The FIA system allows analysis of 20 samples per hour without prior treatment. The proposed method showed a good correlation with that of the Sigma Kit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article, an implementation of structural health monitoring process automation based on vibration measurements is proposed. The work presents an alternative approach which intent is to exploit the capability of model updating techniques associated to neural networks to be used in a process of automation of fault detection. The updating procedure supplies a reliable model which permits to simulate any damage condition in order to establish direct correlation between faults and deviation in the response of the model. The ability of the neural networks to recognize, at known signature, changes in the actual data of a model in real time are explored to investigate changes of the actual operation conditions of the system. The learning of the network is performed using a compressed spectrum signal created for each specific type of fault. Different fault conditions for a frame structure are evaluated using simulated data as well as measured experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this investigation was to determine whether the coupling between dynamic somatosensory information and body sway is similar in children and adults. Thirty children (4-, 6-, and 8-year-olds) and 10 adults stood upright, with feet parallel, and lightly contacting the fingertip to a rigid metal plate that moved rhythmically at 0.2, 0.5, and 0.8 Hz. Light touch to the moving contact surface induced postural sway in all participants. The somatosensory stimulus produced a broadband frequency response in children, while the adult response was primarily at the driving frequency. Gain, as a function of frequency, was qualitatively the same in children and adults. Phase decreased less in 4-year-olds than other age groups, suggesting a weaker coupling to position information in the sensory stimulus. Postural sway variability was larger in children than adults. These findings suggest that, even as young as age 6, children show well-developed coupling to the sensory stimulus. However, unlike adults, this coupling is not well focused at the frequency specified by the somatosensory signal. Children may be unable to uncouple from sensory information that is less relevant to the task, resulting in a broadband response in their frequency spectrum. Moreover, higher sway variability may not result from the sensory feedback process, but rather from the children's underdeveloped ability to estimate an internal model of body orientation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluorescence diagnosis of malignant lesions has been showed as an attractive optical technique due especially to its real-time response and a more objective and quantitative evaluation. Even though the oral cavity allows a direct examination many lesions are diagnosed when it is already in advanced stage, compromising the patient prognosis. In this study, the fluorescence spectroscopy was used to the detection of chemically induced carcinoma at the lateral border of the tongue in a hamster model. Two excitations wavelengths in visible region were applied: 442 and 532 nm. All the spectra results were analyzed comparing with the histopathological diagnosis. The better results were achieved with the 442 nm laser excitation. The spectra from carcinoma showed new emission bands and these were used to determined different ratios for a quantitative analysis. Using the 625-645 nm fluorescence range under 442 nm excitation (A3 coefficient) the percentage of false negative was of 9.1%, however the false positive percentage was of 18.5%. The 532 nm excitation provided a better normal tissue detection compared to 442 nm excitation. The ideal clinical condition is probably the use of multiple wavelengths excitation for a broader tissue fluorescence investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple, rapid, and automated assay for hydrogen peroxide in pharmaceutical samples was developed by combining the multicommutation system with a chemiluminescence (CL) detector. The detection was performed using a spiral flow-cell reactor made from polyethylene tubing that was positioned in front of a photodiode. It allows the rapid mixing of CL reagent and analyte and simultaneous detection of the emitted light. The chemiluminescence was based on the reaction of luminol with hydrogen peroxide catalyzed by hexacyanoferrate(III). The feasibility of the flow system was ascertained by analyzing a set of pharmaceutical samples. A linear response within the range of 2.2-210 μmol l-1 H2O2 with a LD of 1.8 μmol l-1 H2O2 and coefficient of variations smaller than 0.8% for 1.0×10-5 mol l-1 and 6.8×10-5 mol l-1 hydrogen peroxide solutions (n=10) were obtained. Reagents consumption of 90 μg of luminol and 0.7 mg of hexacyanoferrate(III) per determination and sampling rate of 200 samples per hour were also achieved. Copyright © Taylor & Francis Group, LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Structural health monitoring (SHM) is related to the ability of monitoring the state and deciding the level of damage or deterioration within aerospace, civil and mechanical systems. In this sense, this paper deals with the application of a two-step auto-regressive and auto-regressive with exogenous inputs (AR-ARX) model for linear prediction of damage diagnosis in structural systems. This damage detection algorithm is based on the. monitoring of residual error as damage-sensitive indexes, obtained through vibration response measurements. In complex structures there are. many positions under observation and a large amount of data to be handed, making difficult the visualization of the signals. This paper also investigates data compression by using principal component analysis. In order to establish a threshold value, a fuzzy c-means clustering is taken to quantify the damage-sensitive index in an unsupervised learning mode. Tests are made in a benchmark problem, as proposed by IASC-ASCE with different damage patterns. The diagnosis that was obtained showed high correlation with the actual integrity state of the structure. Copyright © 2007 by ABCM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analysis of the active pixel sensor (APS), considering the doping profiles of the photodiode in an APS fabricated in a 0.18 μm standard CMOS technology, is presented. A simple and accurate model for the junction capacitance of the photodiode is proposed. An analytic expression for the output voltage of the APS obtained with this capacitance model is in good agreement with measurements and is more accurate than the models used previously. A different mode of operation for the APS based on the dc level of the output is suggested. This new mode has better low-light-level sensitivity than the conventional APS operating mode, and it has a slower temporal response to the change of the incident light power. At 1μW/cm2 and lower levels of light, the measured signal-to-noise ratio (SNR) of this new mode is more than 10 dB higher than the SNR of previously reported APS circuits. Also, with an output SNR of about 10 dB, the proposed dc level is capable of detecting light powers as low as 20 nW/cm2, which is about 30 times lower than the light power detected in recent reports by other groups. © 2007 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the optimisation and the analytical performances of a label-free impedimetric immunosensor for the detection of tumour marker CA125 based on gold nanoparticles modified screen-printed graphite electrode. Experimental conditions of each step for the developed immunosensor were studied and optimised. The immunosensor response varied linearly (r2 = 0.996) with antigen concentration between 0 and 100 U/mL. The estimated detection limit was 6.7 U/mL. The electrochemical immunosensor allowed unambiguous identification of CA125, while no significant non-specific signal was detected in the case of all negative controls. The analytical usefulness of the impedimetric immunosensor was finally demonstrated analysing serum samples. © 2012 Elsevier B.V. All rights reserved.