991 resultados para Software CAD 3D para vestu


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The kinematics is a fundamental tool to infer the dynamical structure of galaxies and to understand their formation and evolution. Spectroscopic observations of gas emission lines are often used to derive rotation curves and velocity dispersions. It is however difficult to disentangle these two quantities in low spatial-resolution data because of beam smearing. In this thesis, we present 3D-Barolo, a new software to derive the gas kinematics of disk galaxies from emission-line data-cubes. The code builds tilted-ring models in the 3D observational space and compares them with the actual data-cubes. 3D-Barolo works with data at a wide range of spatial resolutions without being affected by instrumental biases. We use 3D-Barolo to derive rotation curves and velocity dispersions of several galaxies in both the local and the high-redshift Universe. We run our code on HI observations of nearby galaxies and we compare our results with 2D traditional approaches. We show that a 3D approach to the derivation of the gas kinematics has to be preferred to a 2D approach whenever a galaxy is resolved with less than about 20 elements across the disk. We moreover analyze a sample of galaxies at z~1, observed in the H-alpha line with the KMOS/VLT spectrograph. Our 3D modeling reveals that the kinematics of these high-z systems is comparable to that of local disk galaxies, with steeply-rising rotation curves followed by a flat part and H-alpha velocity dispersions of 15-40 km/s over the whole disks. This evidence suggests that disk galaxies were already fully settled about 7-8 billion years ago. In summary, 3D-Barolo is a powerful and robust tool to separate physical and instrumental effects and to derive a reliable kinematics. The analysis of large samples of galaxies at different redshifts with 3D-Barolo will provide new insights on how galaxies assemble and evolve throughout cosmic time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Die Transmissionselektronenmikroskopie gepaart mit bioinformatischen Methoden zur digitalen Bildverarbeitung ist ein schneller Weg zur Erstellung dreidimensionaler Rekonstruktionen großer Proteinkomplexe. Durch die Kombination der 3D-Elektronenmikroskopie mit der Röntgenstruktur von Untereinheiten erhält man ein pseudoatomares Modell der Quartärstruktur.rnIn dieser Arbeit wurden auf diese Weise die Quartärstrukturen von drei unterschiedlichen respiratorischen Proteinen analysiert (einem Hämoglobin und zwei Hämocyaninen). Zudem wurden spezielle Software-Tools entwickelt, um vorhandene Softwarepakete besser miteinander kombinieren zu können.rnDie ca. 15Å 3D-Rekonstruktion des Hämoglobins vom Wasserfloh Daphnia pulex klärt die umstrittene Frage, wie viele Untereinheiten die Quartärstruktur aufbauen: Es sind 16 (mit je zwei Häm-Domänen), angeordnet in zwei Schichten als D4-symmetrisches Sandwich. Die ca. 15 Å 3D-Rekonstruktion des 2x6meren Hämocyanins des Flusskrebses Astacus leptodactylus gibt neue Einblicke in die Kontaktstelle zwischen den beiden Hexameren; sie liegt im Bereich der Domäne 3. Bei dem aus 48 Untereinheiten bestehenden Hämocyanin des Pfeilschwanzes Limulus polyphemus wurde eine Auflösung von ca. 7 Å erreicht. Die Homologiemodelle der Untereinheiten wurden flexibel gefittet. An einer der Kontaktstellen zwischen den beiden Halbmolekülen wurden Molekulardynamik (MD)-Simulationen durchgeführt, um mehr über die Art der chemischen Bindung an dieser Kontaktstelle zu erfahren.rnSpeziell für die Kombination von 3D-Elektronenmikroskopie und MD-Simulation wurden verschiedene bioinformatische Werkzeuge und eine leicht zu erweiternde universelle grafische Benutzeroberfläche (GUI) entwickelt.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Negli ultimi 20 anni il progresso tecnologico ha segnato un profondo cambiamento in svariati ambiti tra i quali quello della Sanità in cui hanno preso vita apparecchiature diagnostiche, cosiddette “digitali native”, come la Tomografia Computerizzata (TC), la Tomografia ad Emissione di Positroni (PET), la Risonanza Magnetica Nucleare (RMN), l’Ecografia. A differenza delle diagnostiche tradizionali, come ad esempio la Radiologia convenzionale, che forniscono come risultato di un esame un’immagine bidimensionale ricavata dalla semplice proiezione di una struttura anatomica indagata, questi nuovi sistemi sono in grado di generare scansioni tomografiche. Disporre di immagini digitali contenenti dati tridimensionali rappresenta un enorme passo in avanti per l’indagine diagnostica, ma per poterne estrapolare e sfruttare i preziosi contenuti informativi occorrono i giusti strumenti che, data la natura delle acquisizioni, vanno ricercati nel mondo dell’Informatica. A tal proposito il seguente elaborato si propone di presentare un software package per la visualizzazione, l’analisi e l’elaborazione di medical images chiamato 3D Slicer che rappresenta un potente strumento di cui potersi avvalere in differenti contesti medici. Nel primo capitolo verrà proposta un’introduzione al programma; Seguirà il secondo capitolo con una trattazione più tecnica in cui verranno approfondite alcune funzionalità basilari del software e altre più specifiche; Infine nel terzo capitolo verrà preso in esame un intervento di endoprotesica vascolare e come grazie al supporto di innovativi sistemi di navigazione chirurgica sia possibile avvalersi di 3D Slicer anche in ambiente intraoperatorio

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Una tracciato anormale della rotula può provocare dolore anteriore al ginocchio dopo un’artroplastica e può condurre al fallimento dell’intervento stesso. È importante quindi valutare questo tracciato sia intra che post-operatoriamente, anche per validare disegni protesici innovativi e supportare il chirurgo per le più critiche decisioni chirurgiche al momento dell’impianto. Ad oggi però le valutazioni in-vivo della cinematica femoro-rotulea sono poche e poco attendibili; è per questi motivi che abbiamo deciso di analizzare l’articolazione con la tecnica video-fluoroscopica, appositamente adattata allo scopo di tale studio, a sei mesi di follow-up dall’intervento. Per lo studio abbiamo esaminato, tramite video-fluoroscopia 3D, sette pazienti che hanno subito l’impianto di una protesi totale al ginocchio con ricopertura della rotula. Successivamente le immagini sono state elaborate con un apposito software per ricostruire la cinematica 3D, e sono stati ottenuti i grafici per ogni grado di libertà dell’articolazione. Dall’analisi dei risultati, la tecnica utilizzata è risultata fattibile ed affidabile, infatti dai grafici si nota come la normale cinematica delle articolazioni studiate sia stata ripristinata. Questo studio, oltre a validare l’applicazione della tecnica video-fluoroscopica all’articolazione femoro-rotulea oltre che a quella tibio-femorale, dopo un confronto con i dati derivanti dalla navigazione chirurgica, ha consentito di validare anche questa tecnica intra-operatoria. Questo risultato potrà condurre ad una maggiore precisione nell’allineamento delle componenti protesiche da parte del chirurgo, con conseguente riduzione del rischio di fallimento dell’impianto.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In questo elaborato sono state messe a confronto differenti procedure per la creazione di file in formato STL a partire da dati tomografici. Questo tipo di formato di dati è attualmente molto richiesto in quanto è adottato dalle stampanti 3D. I tre software presi in analisi, nello specifico, sono: DEVIDE, un programma open source, compatibile sia con Windows che con Linux, sviluppato presso la Delft University of Technology, nei Paesi Bassi; Imagej, un programma informatico di elaborazione digitale delle immagini, accessibile a tutti, basato su Sun-Java e sviluppato dal National Institutes of Health negli Stati Uniti; e infine VGStudioMax, un software sviluppato in Germania dalla VolumeGraphics GmbH. Un confronto diretto di questi software ha portato ad evidenziare i pregi ed i difetti d’ognuno di questi programmi, prendendo come criteri svariati fattori, tra cui la possibilità di scelta di uno o più soglie per i livelli di grigio, la velocità di esecuzione, il fatto che sia open-source o meno, ecc. I risultati ottenuti tramite l’utilizzo di slice filtrate riguardanti una Cera Anatomica e un Feticcio Africano, sono stati molto soddisfacenti, in quanto hanno permesso la realizzazione di modelli virtuali 3D di entrambi i reperti nel formato richiesto.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’effetto dell’informatica e dell’automazione sulle procedure medico sanitarie si sta manifestando in maniera sempre più ampia, portando notevoli vantaggi per la salute e il benessere di tutti i pazienti e al tempo stesso ponendo sfide sempre più complesse alle istituzioni sanitarie e ai produttori di dispositivi medico-sanitari. Al di là dei meriti del singolo prodotto o tecnologia, esiste un fattore strategico che dovrebbe essere sempre considerato nel momento di progettare un software o un dispositivo da utilizzare in ambito sanitario (da parte dei produttori) o nel momento di pianificare l’acquisto di sistemi medicali o diagnostici complessi (da parte delle istituzioni sanitarie): l’aspetto dell’Integrazione, ovvero la capacità del sistema di inserirsi in maniera semplice, efficace e poco costosa in un Workflow (flusso di lavoro) completamente integrato. Nel primo capitolo di questo elaborato finale è stato fatto un quadro generale sull’organizzazione del flusso di lavoro in radiologia e sono stati trattati i vari standard di comunicazione e scambio dati in ambito clinico, in primis DICOM, HL7 e IHE. L’oggetto del secondo capitolo è l’organizzazione e gli obbiettivi del Dipartimento di Radiologia attuati dal Gruppo Villa Maria (GVM) e il confronto di questi ultimi con il contenuto del documento: ‘Linee guida per l’assicurazione di qualita` in teleradiologia ‘che è stata redatta dal Istituto Superiore di Sanita` destinata ad apportare, non solo ai medici radiologi ed ai TSRM ma anche agli altri professionisti della sanità coinvolti, gli elementi di informazione e di metodo per l’organizzazione della teleradiologia nel rispetto delle esigenze della deontologia medica, della sicurezza del paziente, compreso il consenso, anche per quanto riguarda la radioprotezione, la privacy e la qualità. Nel terzo capitolo sono elencati gli strumenti con cui il Dipartimento di radiologia intende perseguire i suoi obbiettivi. Il quarto capitolo tratta la mia esperienza presso una clinica esterna al GVM, in particolare la clinica Santo Stefano, di Porto Potenza Picena, dove sono stati fatti dei test volti a valutare i tempi di caricamento di esami di TAC e RMN sul cloud di GVM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present thesis we address the problem of detecting and localizing a small spherical target with characteristic electrical properties inside a volume of cylindrical shape, representing female breast, with MWI. One of the main works of this project is to properly extend the existing linear inversion algorithm from planar slice to volume reconstruction; results obtained, under the same conditions and experimental setup are reported for the two different approaches. Preliminar comparison and performance analysis of the reconstruction algorithms is performed via numerical simulations in a software-created environment: a single dipole antenna is used for illuminating the virtual breast phantom from different positions and, for each position, the corresponding scattered field value is registered. Collected data are then exploited in order to reconstruct the investigation domain, along with the scatterer position, in the form of image called pseudospectrum. During this process the tumor is modeled as a dielectric sphere of small radius and, for electromagnetic scattering purposes, it's treated as a point-like source. To improve the performance of reconstruction technique, we repeat the acquisition for a number of frequencies in a given range: the different pseudospectra, reconstructed from single frequency data, are incoherently combined with MUltiple SIgnal Classification (MUSIC) method which returns an overall enhanced image. We exploit multi-frequency approach to test the performance of 3D linear inversion reconstruction algorithm while varying the source position inside the phantom and the height of antenna plane. Analysis results and reconstructed images are then reported. Finally, we perform 3D reconstruction from experimental data gathered with the acquisition system in the microwave laboratory at DIFA, University of Bologna for a recently developed breast-phantom prototype; obtained pseudospectrum and performance analysis for the real model are reported.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To retrospectively analyze the performance of a commercial computer-aided diagnosis (CAD) software in the detection of pulmonary nodules in original and energy-subtracted (ES) chest radiographs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate whether measurements on conventional cephalometric radiographs are comparable with 3D measurements on 3D models of human skulls, derived from cone beam CT (CBCT) data. A CBCT scan and a conventional cephalometric radiograph were made of 40 dry skulls. Standard cephalometric software was used to identify landmarks on both the 2D images and the 3D models. The same operator identified 17 landmarks on the cephalometric radiographs and on the 3D models. All images and 3D models were traced five times with a time-interval of 1 week and the mean value of repeated measurements was used for further statistical analysis. Distances and angles were calculated. Intra-observer reliability was good for all measurements. The reproducibility of the measurements on the conventional cephalometric radiographs was higher compared with the reproducibility of measurements on the 3D models. For a few measurements a clinically relevant difference between measurements on conventional cephalometric radiographs and 3D models was found. Measurements on conventional cephalometric radiographs can differ significantly from measurements on 3D models of the same skull. The authors recommend that 3D tracings for longitudinal research are not used in cases were there are only 2D records from the past.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is one of the most important tasks of the forensic pathologist to explain the forensically relevant medical findings to medical non-professionals. However, it is often difficult to comment on the nature and potential consequences of organ injuries in a comprehensive way to individuals with limited knowledge of anatomy and physiology. This rare case of survived pancreatic transaction after kicks to the abdomen illustrates how the application of dedicated software programs for three-dimensional reconstruction can overcome these difficulties, allowing for clear and concise visualization of complex findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bite mark analysis offers the opportunity to identify the biter based on the individual characteristics of the dentitions. Normally, the main focus is on analysing bite mark injuries on human bodies, but also, bite marks in food may play an important role in the forensic investigation of a crime. This study presents a comparison of simulated bite marks in different kinds of food with the dentitions of the presumed biter. Bite marks were produced by six adults in slices of buttered bread, apples, different kinds of Swiss chocolate and Swiss cheese. The time-lapse influence of the bite mark in food, under room temperature conditions, was also examined. For the documentation of the bite marks and the dentitions of the biters, 3D optical surface scanning technology was used. The comparison was performed using two different software packages: the ATOS modelling and analysing software and the 3D studio max animation software. The ATOS software enables an automatic computation of the deviation between the two meshes. In the present study, the bite marks and the dentitions were compared, as well as the meshes of each bite mark which were recorded in the different stages of time lapse. In the 3D studio max software, the act of biting was animated to compare the dentitions with the bite mark. The examined food recorded the individual characteristics of the dentitions very well. In all cases, the biter could be identified, and the dentitions of the other presumed biters could be excluded. The influence of the time lapse on the food depends on the kind of food and is shown on the diagrams. However, the identification of the biter could still be performed after a period of time, based on the recorded individual characteristics of the dentitions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Besides DNA, dental radiographs play a major role in the identification of victims in mass casualties or in corpses with major postmortem alterations. Computed tomography (CT) is increasingly applied in forensic investigations and is used to scan the dentition of deceased persons within minutes. We investigated different restoration materials concerning their radiopacity in CT for dental identification purposes. METHODS: Extracted teeth with different filling materials (composite, amalgam, ceramic, temporary fillings) were CT scanned. Radiopacities of the filling materials were analyzed in extended CT scale images. RESULTS: Radiopacity values ranged from 6000-8500HU (temporary fillings), 4500-17000HU (composite fillings) and >30710HU (Amalgam and Gold). The values were used to define presets for a 3D colored volume rendering software. CONCLUSIONS: The effects of filling material caused streak artifacts could be distinctively reduced for the assessment of the dental status and a postprocessing algorithm was introduced that allows for 3D color encoded visualization and discrimination of different dental restorations based on postmortem CT data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a method for DRR generation as well as for volume gradients projection using hardware accelerated 2D texture mapping and accumulation buffering and demonstrates its application in 2D-3D registration of X-ray fluoroscopy to CT images. The robustness of the present registration scheme are guaranteed by taking advantage of a coarse-to-fine processing of the volume/image pyramids based on cubic B-splines. A human cadaveric spine specimen together with its ground truth was used to compare the present scheme with a purely software-based scheme in three aspects: accuracy, speed, and capture ranges. Our experiments revealed an equivalent accuracy and capture ranges but with much shorter registration time with the present scheme. More specifically, the results showed 0.8 mm average target registration error, 55 second average execution time per registration, and 10 mm and 10° capture ranges for the present scheme when tested on a 3.0 GHz Pentium 4 computer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We developed an object-oriented cross-platform program to perform three-dimensional (3D) analysis of hip joint morphology using two-dimensional (2D) anteroposterior (AP) pelvic radiographs. Landmarks extracted from 2D AP pelvic radiographs and optionally an additional lateral pelvic X-ray were combined with a cone beam projection model to reconstruct 3D hip joints. Since individual pelvic orientation can vary considerably, a method for standardizing pelvic orientation was implemented to determine the absolute tilt/rotation. The evaluation of anatomically morphologic differences was achieved by reconstructing the projected acetabular rim and the measured hip parameters as if obtained in a standardized neutral orientation. The program had been successfully used to interactively objectify acetabular version in hips with femoro-acetabular impingement or developmental dysplasia. Hip(2)Norm is written in object-oriented programming language C++ using cross-platform software Qt (TrollTech, Oslo, Norway) for graphical user interface (GUI) and is transportable to any platform.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the open source framework MARVIN for rapid application development in the field of biomedical and clinical research. MARVIN applications consist of modules that can be plugged together in order to provide the functionality required for a specific experimental scenario. Application modules work on a common patient database that is used to store and organize medical data as well as derived data. MARVIN provides a flexible input/output system with support for many file formats including DICOM, various 2D image formats and surface mesh data. Furthermore, it implements an advanced visualization system and interfaces to a wide range of 3D tracking hardware. Since it uses only highly portable libraries, MARVIN applications run on Unix/Linux, Mac OS X and Microsoft Windows.