979 resultados para Scanning electron microscopy (SEM)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detection of rotavirus RNA by polyacrylamide gel electrophoresis (PAGE) proved to be a highly sensitive and rapid diagnostic test. A comparison of this assay with immuno-electron microscopy (IEM) and enzyme immunoassay (EIA) in 245 faeces from children with gastroenteritis revealed complete agreement between the three assays in 238 (97.14%) samples. Among 75 samples positive in at least one of the three assays, negative results were observed in 5 (6.48%) by PAGE, in 6 (6.76%) by EIA and in none by IEM. Silver staining greatly increased the sensitivity of the PAGE assay. We conclude that although IEM remains the most sensitive and rapid rotavirus diagnostic assay, the PAGE technique has many advantages in its favour, including the non-requirement of expensive equipment, the use of only chemically defined reagents and the capacity to distinguish virus subgroup and variants and to detect non-crossreactive rotaviruses which are missed in serological assays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

First and second instar larvae of some Sarcophagidae (Diptera) of the tribe Raviniini are described on observations with a scanning electron microscope.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L1, L2 and L3 of Oxysarcodexia paulistanensis (Mattos), L3 of O. confusa Lopes, L2 of Ravinia belforti (Prado & Fonseca) and L2 of Oxyvinia excisa (Lopes) were described and figured using scanning electron microscope.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transmission electon microscopy has been employed for the rapid detection of mycoplasma in sera and cell cultures. High speed centrifugation of sera or low speed centrifugation of cell debris, followed by negative staining of the resuspended pellet, detected mycoplasma contamination more frequently than a culture method followed by direct fluorescence (DAPI), which was used as a control procedure. The appearance of the mycoplasma cell border and content gives some information about particle viability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Male genitalia of Oxyvinia exicisa (Lopes), Oxysarcodexia thomax (Walker), O. fluminensis Lopes, Sarcodexia lambens (Wiedemann), Peckia chrysostoma (Wiedemann) and Liopygia ruficornis (Fabricius) were studied based on scanning electron microscope photography. Some important details were evidentiated with this method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mitochondrial (M) and lipid droplet (L) volume density (vd) are often used in exercise research. Vd is the volume of muscle occupied by M and L. The means of calculating these percents are accomplished by applying a grid to a 2D image taken with transmission electron microscopy; however, it is not known which grid best predicts these values. PURPOSE: To determine the grid with the least variability of Mvd and Lvd in human skeletal muscle. METHODS: Muscle biopsies were taken from vastus lateralis of 10 healthy adults, trained (N=6) and untrained (N=4). Samples of 5-10mg were fixed in 2.5% glutaraldehyde and embedded in EPON. Longitudinal sections of 60 nm were cut and 20 images were taken at random at 33,000x magnification. Vd was calculated as the number of times M or L touched two intersecting grid lines (called a point) divided by the total number of points using 3 different sizes of grids with squares of 1000x1000nm sides (corresponding to 1µm2), 500x500nm (0.25µm2) and 250x250nm (0.0625µm2). Statistics included coefficient of variation (CV), 1 way-BS ANOVA and spearman correlations. RESULTS: Mean age was 67 ± 4 yo, mean VO2peak 2.29 ± 0.70 L/min and mean BMI 25.1 ± 3.7 kg/m2. Mean Mvd was 6.39% ± 0.71 for the 1000nm squares, 6.01% ± 0.70 for the 500nm and 6.37% ± 0.80 for the 250nm. Lvd was 1.28% ± 0.03 for the 1000nm, 1.41% ± 0.02 for the 500nm and 1.38% ± 0.02 for the 250nm. The mean CV of the three grids was 6.65% ±1.15 for Mvd with no significant differences between grids (P>0.05). Mean CV for Lvd was 13.83% ± 3.51, with a significant difference between the 1000nm squares and the two other grids (P<0.05). The 500nm squares grid showed the least variability between subjects. Mvd showed a positive correlation with VO2peak (r = 0.89, p < 0.05) but not with weight, height, or age. No correlations were found with Lvd. CONCLUSION: Different size grids have different variability in assessing skeletal muscle Mvd and Lvd. The grid size of 500x500nm (240 points) was more reliable than 1000x1000nm (56 points). 250x250nm (1023 points) did not show better reliability compared with the 500x500nm, but was more time consuming. Thus, choosing a grid with square size of 500x500nm seems the best option. This is particularly relevant as most grids used in the literature are either 100 points or 400 points without clear information on their square size.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In correlative microscopy, light microscopy provides the overview and orientation of the complex cells and tissue, while electron microscopy offers the detailed localization and correlation of subcellular structures. In this chapter we offer detailed high-quality electron microscopical preparation methods for optimum preservation of the cellular ultrastructure. From such preparations serial thin sections are collected and used for comparative histochemical, immunofluorescence, and immunogold staining.In light microscopy histological stains identify the orientation of the sample and immunofluorescence labeling facilitates to find the region of interest, namely, the labeled cells expressing the macromolecule under investigation. Sections, labeled with immunogold are analyzed by electron microscopy in order to identify the label within the cellular architecture at high resolution.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Axial deflection of DNA molecules in solution results from thermal motion and intrinsic curvature related to the DNA sequence. In order to measure directly the contribution of thermal motion we constructed intrinsically straight DNA molecules and measured their persistence length by cryo-electron microscopy. The persistence length of such intrinsically straight DNA molecules suspended in thin layers of cryo-vitrified solutions is about 80 nm. In order to test our experimental approach, we measured the apparent persistence length of DNA molecules with natural "random" sequences. The result of about 45 nm is consistent with the generally accepted value of the apparent persistence length of natural DNA sequences. By comparing the apparent persistence length to intrinsically straight DNA with that of natural DNA, it is possible to determine both the dynamic and the static contributions to the apparent persistence length.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cryo-electron microscopy of vitreous sections (CEMOVIS) has recently been shown to provide images of biological specimens with unprecedented quality and resolution. Cutting the sections remains however the major difficulty. Here, we examine the parameters influencing the quality of the sections and analyse the resulting artefacts. They are in particular: knife marks, compression, crevasses, and chatter. We propose a model taking into account the interplay between viscous flow and fracture. We confirm that crevasses are formed on only one side of the section, and define conditions by which they can be avoided. Chatter is an effect of irregular compression due to friction of the section of the knife edge and conditions to prevent this are also explored. In absence of crevasses and chatter, the bulk of the section is compressed approximately homogeneously. Within this approximation, it is possible to correct for compression by a simple linear transformation for the bulk of the section. A research program is proposed to test and refine our understanding of the sectioning process.