912 resultados para SPECT-CT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the international technological production on biodiesel using bibliometric indicators of patents. The data were gathered from Derwent Innovations Index, from 2000 to 2007. The evolution of patent registration by organizations and individuals was analyzed as well as the classification of inventions. The results are useful to visualize the dynamics of technological production on biodiesel and lay grounds for reflections on use of bibliometric indicators and for ST&I policy in the biodiesel field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microvascular density (MVD) may be an additional prognostic marker for astrocytomas, but the heterogeneity of these tumors limits its use. Thus, imaging examinations such as SPECT-MIBI (2-methoxyisobutyl isonitrile) may take on an indirect role in astrocytoma evaluation. The aim of this study was to evaluate MVD in astrocytomas using immunohistochemistry with anti-CD34 monoclonal antibodies. The relationship between the immunohistochemical data and the parameters obtained from SPECT-MIBI was evaluated. This cross-sectional study evaluated 48 patients with brain tumors including low-grade astrocytomas (LGAs), anaplastic astrocytomas (AAs) and glioblastoma multiformes (GBMs). Patients had been admitted to the Hospital de Cancer de Barretos - Fundação Pio XII, and underwent brain SPECT-MIBI prior to any treatment. MVD was determined under an optical microscope by counting microvessels on slides from each case. SPECT-MIBI images were analyzed visually and semiquantitatively. GBMs, AAs and LGAs represented 50, 16.7 and 33.3% of the total sample, respectively. There were 13 normal and 35 abnormal SPECT-MIBI images. Significant differences in MVD were found between AA and LGA cases (p=0.040), but not between normal and abnormal SPECT-MIBI. The mean counts from SPECT-MIBI were not correlated with MVD. Among the GBM cases, there were no significant findings, except for an increased likelihood of abnormal histological test results. MVD was related to histological grade (in AA and LGA cases) but was not correlated with SPECT-MIBI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this prospective study was to evalute the midpalatal suture in children submitted to rapid palatal expansion, at the end of the retention stage, with CT scans. The sample was comprised of 17 children aged between 5 years 2 months and 10 years 5 months. The tomographic images showed that the midpalatal suture was completely ossified from the anterior nasal spine area to the posterior nasal spine area at the end of the retention phase, that is, 8 to 9 months post-expansion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. Methods: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. results: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. Conclusion: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. Methods: 257 non-filled approximal surfaces from human permanent premolars and molars were recorded by two intraoral digital receptors, a storage phosphor plate (Digora Optime, Soredex) and a solid-state CMOS sensor (Digora Toto, Soredex), and scanned in a cone beam CT unit (3D Accuitomo FPD80, Morita) with a FOV of 4 cm and a voxel size of 0.08 mm. Image sections were carried out in the axial and mesiodistal tooth planes. Six observers recorded surface cavitation in all images. Validation of the true absence or presence of surface cavitation was performed by inspecting the surfaces under strong light with the naked eye. Differences in sensitivity, specificity and agreement were estimated by analysing the binary data in a generalized linear model using an identity link function. Results: A significantly higher sensitivity was obtained by all observers with CBCT (p,0.001), which was not compromised by a lower specificity. Therefore, a significantly higher overall agreement was obtained with CBCT (p,0.001). There were no significant differences between the Digora Optime phosphor plate system and the Digora Toto CMOS sensor for any parameter. Conclusions: CBCT was much more accurate in the detection of surface cavitation in approximal surfaces than intraoral receptors. The differences are interpreted as clinically significant. A CBCT examination performed for other reasons should also be assessed for approximal surface cavities in teeth without restorations. © 2013 The British Institute of Radiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare two endodontic preparation systems using micro-CT analysis. Twenty-four one-rooted mandibular premolars were selected and randomly assigned to two groups. The samples (n = 12) of Group 1 were prepared using the ProTaper Universal rotary system, while Group 2 (n = 12) was prepared using the EndoEZE AET system complemented by manual apical preparation with K-type hand files up to #30. A 2.5% sodium hypochlorite solution was used in both groups for irrigating. Both groups were scanned by highresolution microcomputed tomography before and after preparation (SkyScan 1172, SkyScan, Kontich, Belgium). The root canal volume and surface area was measured before and after preparation, and the differences were calculated and analyzed for statistically significant differences using ANOVA complemented by the Tukey test (p < 0.05). The results showed no statistically significant differences between the mean volumes of dentin removal by the two systems. However, the EndoEZE AET system presented a significantly greater mean surface area compared to the ProTaper system (p < 0.05). The EndoEZE AET system enabled preparation of a greater root canal surface area when compared to the ProTaper Universal system. There seemed to be no difference in dentin volume loss between the two systems used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the influence of anatomical location on computed tomography (CT) numbers in mid- and full field of view (FOV) cone beam computed tomography (CBCT) scans. Study Design: Polypropylene tubes with varying concentrations of dipotassium hydrogen phosphate (K2HPO4) solutions (50-1200 mg/mL) were imaged within the incisor, premolar, and molar dental sockets of a human skull phantom. CBCT scans were acquired using the NewTom 3G and NewTom 5G units. The CT numbers of the K2HPO 4 phantoms were measured, and the relationship between CT numbers and K2HPO4 concentration was examined. The measured CT numbers of the K2HPO4 phantoms were compared between anatomical sites. Results: At all six anatomical locations, there was a strong linear relationship between CT numbers and K2HPO4 concentration (R 2 > 0.93). However, the absolute CT numbers varied considerably with the anatomical location. Conclusion: The relationship between CT numbers and object density is not uniform through the dental arch on CBCT scans. © 2013 Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El Instituto Nicaraguense de Energia presenta al BID una solicitud de cooperacion tecnica consistente en el adiestramiento de un grupo de profesionales en tecnicas de analisis de sistemas electricos debiles o longitudinales de paises en desarrollo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A literatura contemporânea expressa o rompimento das fronteiras entre a cultura erudita e a cultura de massa ou comercial, criando formas híbridas que convivem no interior do texto. No romance Voyages de l’autre cote (1975), de Jean-Marie Gustave Le Clézio, as canções do pop rock embalam as viagens da fada Naja Naja e de seus amigos em busca do ‘outro lado’. Desta forma, a impregnação da música popular à escritura poética, parece ajudar a libertar a imaginação, preparando as personagens para o encontro do infinito sensível.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)