979 resultados para Repertory grid technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Meshless methods are used for their capability of producing excellent solutions without requiring a mesh, avoiding mesh related problems encountered in other numerical methods, such as finite elements. However, node placement is still an open question, specially in strong form collocation meshless methods. The number of used nodes can have a big influence on matrix size and therefore produce ill-conditioned matrices. In order to optimize node position and number, a direct multisearch technique for multiobjective optimization is used to optimize node distribution in the global collocation method using radial basis functions. The optimization method is applied to the bending of isotropic simply supported plates. Using as a starting condition a uniformly distributed grid, results show that the method is capable of reducing the number of nodes in the grid without compromising the accuracy of the solution. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electronics Letters Vol.38, nº 19

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chagas'disease has been described as the commonest form of chronic myocarditis. An immunologic pathogenesis has been discribed for this form of the disease. So far, no immunoperoxidase technique has been used for the detection of immunological deposits in chronic experimental Chagas'myocardiopathy. Forty-one Swiss mice, three months old were inoculated intraperitoneally with doses between 10 and 10(5) Tulahuen trypomastigotes. Mice were reinoculated one month after with doses between 10² and 10(5) and sacrificed at 6 (n=21) and 9 months (n=9) after the first inoculation. ECGs were recorded before sacrifice. Immunoperoxidase technique (peroxidase-antiperoxidase method), immunofluorescence (direct and indirect) as well as histological studies were performed in myocardiums and skeletal muscles of the surviving animals. The most sensitive methods for detecting chronic chagasic infection were the routine histologic studies (73%) and the ECGs 83% and 89% on 6 and 9 mo. post-infected mice, respectively. Myocardial involvement varied from interstitial mild focal lymphocyte infiltrates up to replacement of myocytes by loose connective tissue. Atrial myocardiums (21/23, 91%) were more affected than ventricles (9/23, 39%). Typical chagasic nests were rarely found. Skeletal muscle involvement (11/18 and 7/9) varied from mild to extensive lymphocyte and plasmacell infiltrates, and necrotic fibers. The involved antigen were shown in skeletal muscles by the immunoperoxidase technique as diffusely arranged granular intracytoplasmatic deposit for both IgC and total immunoglobulins. The coincidence between this technique and histologic muscle lesions was 11/18 (61(%) in 6 mo. and 6/8 (75%) at 9 mo. post-infection. In heart, delicate granular deposits of total immunoglobulins were seen diffusely arranged within the ventricular myocytes; coincidence between immunoperoxidase technique anl histologic involvement increased from 36 to 66% in animals sacrifeced 6 and 9 mo. post-infection. This strongly stressed the increase of immunologic phenomena with the chronification of infection. Concerning sensitivity, immunoperoxidase and direct immunofluorescence were highly sensitive in skeletal muscle (100%, p < 0.01). Conversely, direct immunofluorescence technique showed poor results in heart while immunoperoxidase increased its sensitivity from 21.4% (at 6 mo.) to 66.6% (at 9 mo.) post-infection (p < 0.001). Considering the necessity of obtaining an adequate vaccine in order to prevent this disease an experimental model like this, rendering immunological reactions as revealed by the immunoperoxidase technique, would be useful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica no Ramo de Automação e Electrónica Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A clinical trial involving 80 patients of both sexes, from ages 15 to 55, with chronic intestinal or hepatointestinal schistosomiasis mansoni, was carried out to evaluate the therapeutical efficacy of different dose regimens of praziquantel. The patients were randomly allocated into four groups with an equal number of cases and were then treated with one of the following dosages: 60 mg/kg for 1 day; 60 mg/kg daily for 2 days; 60 mg/kg daily for 3 days; and 30 mg/kg daily for 6 days. The assessment of parasitological cure was based on the quantitative oogram technique through rectal mucosa biopsies which were undertaken prior to, as well as, 1,2,4 and 6 months post-treatment. Concurrently, stool examinations according to the qualitative Hoffman, Pons & Janer (HPJ) and the quantitative Kato-Katz (K-K) methods were also performed. The best tolerability was observed with 30 mg/kg daily for 6 days whereas the highest incidence of side-effects (mainly dizziness and nausea) was found with 60 mg/kg daily for 3 days. No serious adverse drug reaction has occurred. The achieved cure rates were: 25% with 60 mg/kg for 1 day; 60% with 60 mg/kg daily for 2 days; 89.5% with 60 mg/kg daily for 3 days; and 90% with 30 mg/kg daily for 6 days. At the same time there has been a downfall of 64%, 73%, 87% and 84% respectively, in the median number of viable S. mansoni ova per gram of tissue. Thus, a very clear direct correlation between dose and effect could be seen. The corresponding cure rates according to stool examinations by HPJ were 39%, 80%, 100% and 95%; by K-K 89%, 100%, 100% and 100%. This discrepancy in results amongst the three parasitological methods is certainly due to their unequal accuracy. In fact, when the number of viable eggs per gram of tissue fell below 5,000 the difference in the percentage of false negative findings between HPJ (28%) and K-K (80%) became significative. When this number dropped to less than 2,000 the percentage of false negative results obtained with HPJ (49%) turned significant in relation to the oogram as well. In conclusion, it has been proven that praziquantel is a highly efficacious agent against S. mansoni infections. If administered at a total dose of 180 mg/kg divided into either 3 or 6 days, it yields a 90% cure rate. Possibly, one could reach 100% by increasing the total dose to 240 mg/kg. Furthermore, it was confirmed that the quantitative oogram technique is the most reliable parasitological method when evaluating the efficacy of new drugs in schistosomiasis mansoni.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEEE International Symposium on Circuits and Systems, pp. 232 – 235, Seattle, EUA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prescribed fire is a technique that is often used, it has several advantages. Pedological and hydropedological techniques were tested to assess the prescribed fire changes may cause in soils. This work was performed in Tresminas area (Vila Pouca de Aguiar, Northern Portugal), during February and March 2011. In the present study we applied several techniques. For the field sampling was followed the ISO 10381-1[1], ISO 10381-2[2], and FAO rules [3], as well as were used a grid with 17 points for measuring the soil parameters. During the fire, we have tried to check, with the assistance of the Portuguese Forestry Authority, some important parameters such as, the propagation speed, the size of the flame front and the intensity of energy emitted per unit area. Before the fire, was collected carefully soil disturbed and undisturbed samples for laboratory analysis, and measured soil water content; we also have placed four sets of thermocouples for measuring soil temperature. After the fire, were collected the thermocouples and new soil samples; the water content were measured in the soil and collected ashes. In the laboratory, after preparing and sieving the samples, were determined the soil particle size. The soil pH and electrical conductivity in water was also determined. The total carbon (TC) and inorganic carbon (IC)[4] was measured by a Shimadzu TOC-Vcsn. The water content in soil has not varied significantly before and after the fire, as well as soil pH and soil electrical conductivity. The TC and IC did not change, which was expected, since the fire not overcome the 200° C. Through the various parameters, we determined that the prescribed fire didn’t affect the soil. The low temperature of the fire and its rapid implementation that lead to the possible adverse effects caused by the wild fire didn’t occurred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TiO2 films have been deposited on ITO substrates by dc reactive magnetron sputtering technique. It has been found that the sputtering pressure is a very important parameter for the structure of the deposited TiO2 films. When the pressure is lower than 1 Pa, the deposited has a dense structure and shows a preferred orientation along the [101] direction. However, the nanorod structure has been obtained as the sputtering pressure is higher than 1 Pa. These nanorods structure TiO2 film shows a preferred orientation along the [110] direction. The x-ray diffraction and the Raman scattering measurements show both the dense and the nanostructure TiO2 films have only an anatase phase, no other phase has been obtained. The results of the SEM show that these TiO2 nanorods are perpendicular to the ITO substrate. The TEM measurement shows that the nanorods have a very rough surface. The dye-sensitized solar cells (DSSCs) have been assembled using these TiO2 nanorod films prepared at different sputtering pressures as photoelectrode. And the effect of the sputtering pressure on the properties of the photoelectric conversion of the DSSCs has been studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smart grids with an intensive penetration of distributed energy resources will play an important role in future power system scenarios. The intermittent nature of renewable energy sources brings new challenges, requiring an efficient management of those sources. Additional storage resources can be beneficially used to address this problem; the massive use of electric vehicles, particularly of vehicle-to-grid (usually referred as gridable vehicles or V2G), becomes a very relevant issue. This paper addresses the impact of Electric Vehicles (EVs) in system operation costs and in power demand curve for a distribution network with large penetration of Distributed Generation (DG) units. An efficient management methodology for EVs charging and discharging is proposed, considering a multi-objective optimization problem. The main goals of the proposed methodology are: to minimize the system operation costs and to minimize the difference between the minimum and maximum system demand (leveling the power demand curve). The proposed methodology perform the day-ahead scheduling of distributed energy resources in a distribution network with high penetration of DG and a large number of electric vehicles. It is used a 32-bus distribution network in the case study section considering different scenarios of EVs penetration to analyze their impact in the network and in the other energy resources management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado para obtenção do grau de Mestre em Engenharia Eletrotécnica Ramo Automação e Eletrónica Industrial