837 resultados para RADIOLOGICAL PERSONNEL


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Instillation of contrast medium into stab wounds has shown promising results regarding visibility and assessment of general stab direction with computed tomography. However, the accuracy of this method--and, incidentally also probing of stab wounds--has to our knowledge not previously been examined. Also the effect of bluntness of different stabbing objects on the examination of stab wounds was not considered before this study. METHODS Using a pocket-knife, a steak-knife, and a Phillips screwdriver, nine stab wounds each were inflicted to three pork haunches. The depths of the stab wounds were determined by probing and multislice computed tomography (MSCT) after instillation of a contrast medium (CM) and then compared to those observed by dissection, our internal "gold standard". RESULTS In stab wounds inflicted by knives, MSCT-CM and probing provided results which differed by roughly 10-11% from the dissection results. In screwdriver stabs MSCT-CM showed a deviation of almost 30%, probing over 33%. DISCUSSION MSCT-CM is a possible alternative to layer-by-layer dissection in autopsy cases of knife stab wounds. Probing, although obsolete in post-mortem examinations, is sufficiently accurate in determining the length of a stab wound of a living person. In cases of stab wounds with blunt objects such as screwdrivers, neither MSCT-CM nor probing proved to be sufficiently accurate. CONCLUSION MSCT-CM is a possible alternative to layer-by-layer dissection in autopsy cases of knife stab wounds. Probing, although obsolete in post-mortem examinations, is sufficiently accurate in determining the length of a stab wound of a living person. In cases of stab wounds with blunt objects such as screwdrivers, neither MSCT-CM nor probing proved to be sufficiently accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Intensity-modulated radiotherapy (IMRT) credentialing for a EORTC study was performed using an anthropomorphic head phantom from the Radiological Physics Center (RPC; RPC(PH)). Institutions were retrospectively requested to irradiate their institutional phantom (INST(PH)) using the same treatment plan in the framework of a Virtual Phantom Project (VPP) for IMRT credentialing. MATERIALS AND METHODS CT data set of the institutional phantom and measured 2D dose matrices were requested from centers and sent to a dedicated secure EORTC uploader. Data from the RPC(PH) and INST(PH) were thereafter centrally analyzed and inter-compared by the QA team using commercially available software (RIT; ver.5.2; Colorado Springs, USA). RESULTS Eighteen institutions participated to the VPP. The measurements of 6 (33%) institutions could not be analyzed centrally. All other centers passed both the VPP and the RPC ±7%/4 mm credentialing criteria. At the 5%/5 mm gamma criteria (90% of pixels passing), 11(92%) as compared to 12 (100%) centers pass the credentialing process with RPC(PH) and INST(PH) (p = 0.29), respectively. The corresponding pass rate for the 3%/3 mm gamma criteria (90% of pixels passing) was 2 (17%) and 9 (75%; p = 0.01), respectively. CONCLUSIONS IMRT dosimetry gamma evaluations in a single plane for a H&N prospective trial using the INST(PH) measurements showed agreement at the gamma index criteria of ±5%/5 mm (90% of pixels passing) for a small number of VPP measurements. Using more stringent, criteria, the RPC(PH) and INST(PH) comparison showed disagreement. More data is warranted and urgently required within the framework of prospective studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Sexuality is an essential aspect of human function, well-being and quality of life. Many people have sex without complications. However, there are some people who need to seek emergency medical help for related health problems. The aim of this study was to present a first overview of patients who received a radiological examination related to sexual intercourse based emergency department admission. METHODS Our centralized electronic patient record database was reviewed for patients who had been admitted to our emergency department with an emergency after sexual intercourse between 2000 and 2011. The database was scanned for the standardized key words 'sexual intercourse' or 'coitus' retrospectively. For all patients identified in the electronic patient record database the radiological examinations were searched for manually in our Radiology Information System, and reviewed by three independent radiologists. RESULTS One hundred and twenty nine out of 445 (29,0%) patients received a radiological examination after immediate emergency department admission related to sexual intercourse. Fifty two out of 129 (40.3%) patients had positive radiological findings while 77 (59.7%) did not. Eighty point seven percent (n = 42) of the radiological findings were a sexual intercourse-associated pathology and 19.2% (n = 10) were considered to be incidental findings. Age and male sex positively correlated with radiological imaging workup (p<0.001, respectively p<0.037). The most common sexual intercourse-associated pathology was headache attributed to cerebrovascular insult (n = 21, 40.3%) followed by epididymitis (n = 7, 16.6%) and obstructive uropathy (n = 5, 11.6%). Of the patients with headache attributed to non-traumatic intracranial hemorrhage, subarachnoid hemorrhage (n = 14, 66.6%) was the most common, followed by intracerebral bleeding (n = 4, 19.0%) and one subdural hemorrhage. CONCLUSIONS Pathological findings are manifold. Cerebral imaging is the most common type of radiological imaging performed. Further prospective and standardized studies should be performed to better evaluate the significance of radiological imaging in this patient collective with the aim to gain better knowledge on what patients profit from what type of radiological imaging when presenting with a sexual intercourse related emergency. ADVANCES IN KNOWLEDGE The present study provides a first overview on radiological findings of sexual intercourse related emergency department admissions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The perioperative management of patients with mediastinal masses is a special clinical challenge in our field. Even though regional anaesthesia is normally the first choice, in some cases it is not feasible due to the method of operation. In these cases general anaesthesia is the second option but can lead to respiratory and haemodynamic decompensation due to tumor-associated compression syndrome (mediastinal mass syndrome). The appropriate treatment begins with the preoperative risk classification on the basis of clinical and radiological findings. In addition to anamnesis, chest radiograph, and CT, dynamical methods (e.g. pneumotachography and echocardiography) should be applied to verify possible intraoperative compression syndromes. The induction of general anaesthesia is to be realized in awake-fiberoptic intubation with introduction of the tube via nasal route while maintaining the spontaneous breathing of the patient. The anaesthesia continues with short effective agents applied inhalative or iv. If possible from the point of operation, agents of muscle relaxation are not to be applied. If the anaesthesia risk is classified as uncertain or unsafe, depending on the location of tumor compression (tracheobronchial tree, pulmonary artery, superior vena cava), alternative techniques of securing the respiratory tract (different tubes, rigid bronchoscope) and cardiopulmonary bypass with extracorporal oxygen supply are prepared. For patients with severe clinical symptoms and extensive mediastinal mass, the preoperative cannulation of femoral vessels is also recommended. In addition to fulfilling technical and personnel requirements, an interdisciplinary cooperation of participating fields is the most important prerequisite for the optimal treatment of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Workflow interruptions during surgery may cause a threat to patient's safety. Workflow interruptions were tested to predict failure in action regulation that in turn predicts near-accidents in surgery and related health care. Methods One-hundred-and-thirty-three theater nurses and physicians from eight Swiss hospitals participated in a cross-sectional questionnaire survey. The study participation rate was 43%. Results Structural equation modeling confirmed an indirect path from workflow interruptions through cognitive failure in action regulation on near-accidents (p < 0.05). The indirect path was stronger for workflow interruptions by malfunctions and task organizational blockages compared with workflow interruptions that were caused by persons. The indirect path remained meaningful when individual differences in conscientiousness and compliance with safety regulations were controlled. Conclusion Task interruptions caused by malfunction and organizational constraints are likely to trigger errors in surgery. Work redesign is recommended to reduce workflow interruptions by malfunction and regulatory constraints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until today, most of the documentation of forensic relevant medical findings is limited to traditional 2D photography, 2D conventional radiographs, sketches and verbal description. There are still some limitations of the classic documentation in forensic science especially if a 3D documentation is necessary. The goal of this paper is to demonstrate new 3D real data based geo-metric technology approaches. This paper present approaches to a 3D geo-metric documentation of injuries on the body surface and internal injuries in the living and deceased cases. Using modern imaging methods such as photogrammetry, optical surface and radiological CT/MRI scanning in combination it could be demonstrated that a real, full 3D data based individual documentation of the body surface and internal structures is possible in a non-invasive and non-destructive manner. Using the data merging/fusing and animation possibilities, it is possible to answer reconstructive questions of the dynamic development of patterned injuries (morphologic imprints) and to evaluate the possibility, that they are matchable or linkable to suspected injury-causing instruments. For the first time, to our knowledge, the method of optical and radiological 3D scanning was used to document the forensic relevant injuries of human body in combination with vehicle damages. By this complementary documentation approach, individual forensic real data based analysis and animation were possible linking body injuries to vehicle deformations or damages. These data allow conclusions to be drawn for automobile accident research, optimization of vehicle safety (pedestrian and passenger) and for further development of crash dummies. Real 3D data based documentation opens a new horizon for scientific reconstruction and animation by bringing added value and a real quality improvement in forensic science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been a renewed interest in disaster epidemiology after the World Trade Center and Pentagon terrorist attacks of 2001, the devastation of Hurricane Katrina and the overwhelming loss of life that resulted from the tsunami that originated in the Indian Ocean and struck Indonesia and other adjacent countries on December 26, 2004. Institutions that have accepted the challenge of training the next generation of public health professionals as well as to continue the education of the dedicated professionals already serving in public health fields have a responsibility to train practitioners in the basic principles of disaster epidemiology as well as in practical applications of these principles. This culminating experience project involved developing an on-line course complete with the background information as well as relevant case studies that can be used as a curriculum for an introductory course in disaster epidemiology. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation consists of two parts: (1) Exposure of pharmacy personnel to antineoplastic drugs. The Salmonella reversion test was used to measure the mutagenic activities of urine concentrates from individuals preparing antineoplastic drugs for intravenous administration. Longitudinal studies were performed in which the total urine produced in 24-hour periods was collected, starting on a Sunday at 7 P.M. after a duty-free weekend and extending over an eight-day period. There was no detectable increase in mutagenic activity in the urine concentrates of three pharmacy administrators who had no contact with these drugs. All six individuals admixing drugs in open-faced, horizontal laminar flow hoods displayed a two-fold increase in mutagenesis by the fourth day with peak values of 2.7 to 24-fold occurring on days five and six, reduced values by day seven with a return to the spontaneous level by day eight. When four of the six positive individuals in the preceding experiment admixed comparable amounts of antineoplastic drugs in a closed-faced, vertical laminar flow hood, no increase in mutagenic activity was detected in their urine concentrates over the eight-day period. (2) Estimate of potential carcinogenic risks of antineoplastic drugs. Excision repair is the major repair system that is involved with the elimination of chemically induced DNA (deoxyribonucleic acid) lesions. This DNA excision repair capability increases in mammalian species with longer life span such as humans. In this study, the effect of functional DNA excision repair on the mutagenesis invoked by 17 antineoplastic drugs was determined by using a Salmonella/Microsome assay which was expanded to include some uvr('+) counterparts of the excisionless (uvrB) tester strains routinely employed. Although extrapolation cannot be made from bacteria to humans, one should be able to make a qualitative comparison as to which antineoplastic drugs are more potentially carcinogenic to humans based on the effects of excision repair on their mutagenesis in bacteria. The tested antineoplastic drugs were divided into three classes: those requiring excision repair for mutagenesis; those producing nonrepairable genetic damage; and those producing mostly repairable premutational DNA lesions. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of the Anisotropic Analytical Algorithm (AAA) implemented in the Eclipse treatment planning system (TPS) was evaluated using theRadiologicalPhysicsCenteranthropomorphic lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was covered such that at least 95% of Planning Target Volume (PTV) received 100% of the prescribed dose while ensuring that normal tissue constraints were followed as well. Calculated doses were exported from the Eclipse TPS and compared with the experimental data as measured using thermoluminescence detectors (TLD) and radiochromic films that were placed inside the phantom. The results demonstrate that the AAA superposition-convolution algorithm is able to calculate SBRT treatment plans with all clinically used photon beams in the range from 6 MV to 18 MV. The measured dose distribution showed a good agreement with the calculated distribution using clinically acceptable criteria of ±5% dose or 3mm distance to agreement. These results show that in a heterogeneous environment a 3D pencil beam superposition-convolution algorithms with Monte Carlo pre-calculated scatter kernels, such as AAA, are able to reliably calculate dose, accounting for increased lateral scattering due to the loss of electronic equilibrium in low density medium. The data for high energy plans (15 MV and 18 MV) showed very good tumor coverage in contrast to findings by other investigators for less sophisticated dose calculation algorithms, which demonstrated less than expected tumor doses and generally worse tumor coverage for high energy plans compared to 6MV plans. This demonstrates that the modern superposition-convolution AAA algorithm is a significant improvement over previous algorithms and is able to calculate doses accurately for SBRT treatment plans in the highly heterogeneous environment of the thorax for both lower (≤12 MV) and higher (greater than 12 MV) beam energies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) uses both on-site and remote reviews to credential institutions for participation in clinical trials. Anthropomorphic quality assurance (QA) phantoms are one tool the RPC uses to remotely audit institutions, which include thermoluminescent dosimeters (TLDs) and radiochromic film. The RPC desires to switch from TLD as the absolute dosimeter in the phantoms, to optically stimulated luminescent dosimeters (OSLDs), but a problem lies in the angular dependence exhibited by the OSLD. The purpose of this study was to characterize the angular dependence of OSLD and establish a correction factor if necessary, to provide accurate dosimetric measurements as a replacement for TLD in the QA phantoms. A 10 cm diameter high-impact polystyrene spherical phantom was designed and constructed to hold an OSLD to study the angular response of the dosimeter under the simplest of circumstances for both coplanar and non-coplanar treatment deliveries. OSLD were irradiated in the spherical phantom, and the responses of the dosimeter from edge-on angles were normalized to the response when irradiated with the beam incident normally on the surface of the dosimeter. The average normalized response was used to establish an angular correction factor for 6 MV and 18 coplanar treatments, and for 6 MV non-coplanar treatments specific to CyberKnife. The RPC pelvic phantom dosimetry insert was modified to hold OSLD, in addition to the TLD, adjacent to the planes of film. Treatment plans of increasing angular beam delivery were developed, three in Pinnacle v9.0 (4-field box, IMRT, and VMAT) and one in Accuray’s MultiPlan v3.5.3 (CyberKnife). The plans were delivered to the pelvic phantom containing both TLD and OSLD in the target volume. The pelvic phantom was also sent to two institutions to be irradiated as trials, one delivering IMRT, and the other a CyberKnife treatment. For the IMRT deliveries and the two institution trials, the phantom also included film in the sagittal and coronal planes. The doses measured from the TLD and OSLD were calculated for each irradiation, and the angular correction factors established from the spherical phantom irradiations were applied to the OSLD dose. The ratio of the TLD dose to the angular corrected OSLD dose was calculated for each irradiation. The corrected OSLD dose was found to be within 1% of the TLD measured dose for all irradiations, with the exception of the in-house CyberKnife deliveries. The films were normalized to both TLD measured dose and the corrected OSLD dose. Dose profiles were obtained and gamma analysis was performed using a 7%/4 mm criteria, to compare the ability of the OSLD, when corrected for the angular dependence, to provide equivalent results to TLD. The results of this study indicate that the OSLD can effectively be used as a replacement for TLD in the RPC’s anthropomorphic QA phantoms for coplanar treatment deliveries when a correction is applied for the dosimeter’s angular dependence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Validation of treatment plan quality and dose calculation accuracy is essential for new radiotherapy techniques, including volumetric modulated arc therapy (VMAT). VMAT delivers intensity modulated radiotherapy treatments while simultaneously rotating the gantry, adding an additional level of complexity to both the dose calculation and delivery of VMAT treatments compared to static gantry IMRT. The purpose of this project was to compare two VMAT systems, Elekta VMAT and Varian RapidArc, to the current standard of care, IMRT, in terms of both treatment plan quality and dosimetric delivery accuracy using the Radiological Physics Center (RPC) head and neck (H&N) phantom. Clinically relevant treatment plans were created for the phantom using typical prescription and dose constraints for Elekta VMAT (planned with Pinnacle3 Smart Arc) and RapidArc and IMRT (both planned with Eclipse). The treatment plans were evaluated to determine if they were clinically comparable using several dosimetric criteria, including ability to meet dose objectives, hot spots, conformity index, and homogeneity index. The planned treatments were delivered to the phantom and absolute doses and relative dose distributions were measured with thermoluminescent dosimeters (TLDs) and radiochromic film, respectively. The measured and calculated doses of each treatment were compared to determine if they were clinically acceptable based upon RPC criteria of ±7% dose difference and 4 mm distance-to-agreement. Gamma analysis was used to assess dosimetric accuracy, as well. All treatment plans were able to meet the dosimetric objectives set by the RPC and had similar hot spots in the normal tissue. The Elekta VMAT plan was more homogenous but less conformal than the RapidArc and IMRT plans. When comparing the measured and calculated doses, all plans met the RPC ±7%/4 mm criteria. The percent of points passing the gamma analysis for each treatment delivery was acceptable. Treatment plan quality of the Elekta VMAT, RapidArc and IMRT treatments were comparable for consistent dose prescriptions and constraints. Additionally, the dosimetric accuracy of the Elekta VMAT and RapidArc treatments was verified to be within acceptable tolerances.