987 resultados para Pressure measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 58 newborn infants a new iridium oxide sensor was evaluated for transcutaneous carbon dioxide (tcPCO2) monitoring at 42 degrees C with a prolonged fixation time of 24 hours. The correlation of tcPCO2 (y; mm Hg) v PaCO2 (x; mm Hg) for 586 paired values was: y = 4.6 + 1.45x; r = .89; syx = 6.1 mm Hg. The correlation was not influenced by the duration of fixation. The transcutaneous sensor detected hypocapnia (PaCO2 less than 35 mm Hg) in 74% and hypercapnia (PCO2 greater than 45 mm Hg) in 74% of all cases. After 24 hours, calibration shifts were less than 4 mm Hg in 90% of the measuring periods. In 86% of the infants, no skin changes were observed; in 12% of infants, there were transitional skin erythemas and in 2% a blister which disappeared without scarring. In newborn infants with normal BPs, continuous tcPCO2 monitoring at 42 degrees C can be extended for as many as 24 hours without loss of reliability or increased risk for skin burns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blood pressures measured casually by a doctor often differ considerably from those recorded during everyday activities away from the medical environment. In the present study, we compared office and ambulatory recorded pressures in 475 consecutive untreated patients diagnosed hypertensive by physicians. Blood pressure monitored non-invasively during the day was, on average 15/7 mmHg lower than the corresponding office pressures. The difference between office and ambulatory recorded pressure tended to be greatest in those patients with the highest office blood pressure levels, although the relationship between the two types of measurement was too weak (r = 0.50 and 0.38 for systolic and diastolic pressure, respectively) to have any predictive value in the individual patient. Office blood pressures were at least 10 mmHg higher than ambulatory pressures in 62% of patients for systolic and 42% for diastolic pressure. Blood pressure levels recorded during ambulatory monitoring were higher than in the doctor's office for 18% of patients for systolic and 22% for diastolic pressure. Among patients with systolic pressures of between 161 and 180 mmHg or diastolic pressures between 96 and 105 mmHg when facing a doctor, 27 and 37% respectively, showed markedly lower systolic (less than 140 mmHg) or diastolic (less than 90 mmHg) ambulatory recorded pressures. These data therefore indicate that ambulatory blood pressure monitoring may help to identify those truly hypertensive patients who are most likely to benefit from antihypertensive therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blood pressure (BP) is a heritable, quantitative trait with intraindividual variability and susceptibility to measurement error. Genetic studies of BP generally use single-visit measurements and thus cannot remove variability occurring over months or years. We leveraged the idea that averaging BP measured across time would improve phenotypic accuracy and thereby increase statistical power to detect genetic associations. We studied systolic BP (SBP), diastolic BP (DBP), mean arterial pressure (MAP), and pulse pressure (PP) averaged over multiple years in 46,629 individuals of European ancestry. We identified 39 trait-variant associations across 19 independent loci (p < 5 × 10(-8)); five associations (in four loci) uniquely identified by our LTA analyses included those of SBP and MAP at 2p23 (rs1275988, near KCNK3), DBP at 2q11.2 (rs7599598, in FER1L5), and PP at 6p21 (rs10948071, near CRIP3) and 7p13 (rs2949837, near IGFBP3). Replication analyses conducted in cohorts with single-visit BP data showed positive replication of associations and a nominal association (p < 0.05). We estimated a 20% gain in statistical power with long-term average (LTA) as compared to single-visit BP association studies. Using LTA analysis, we identified genetic loci influencing BP. LTA might be one way of increasing the power of genetic associations for continuous traits in extant samples for other phenotypes that are measured serially over time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We did a subject-level meta-analysis of the changes (Δ) in blood pressure (BP) observed 3 and 6 months after renal denervation (RDN) at 10 European centers. Recruited patients (n=109; 46.8% women; mean age 58.2 years) had essential hypertension confirmed by ambulatory BP. From baseline to 6 months, treatment score declined slightly from 4.7 to 4.4 drugs per day. Systolic/diastolic BP fell by 17.6/7.1 mm Hg for office BP, and by 5.9/3.5, 6.2/3.4, and 4.4/2.5 mm Hg for 24-h, daytime and nighttime BP (P0.03 for all). In 47 patients with 3- and 6-month ambulatory measurements, systolic BP did not change between these two time points (P0.08). Normalization was a systolic BP of <140 mm Hg on office measurement or <130 mm Hg on 24-h monitoring and improvement was a fall of 10 mm Hg, irrespective of measurement technique. For office BP, at 6 months, normalization, improvement or no decrease occurred in 22.9, 59.6 and 22.9% of patients, respectively; for 24-h BP, these proportions were 14.7, 31.2 and 34.9%, respectively. Higher baseline BP predicted greater BP fall at follow-up; higher baseline serum creatinine was associated with lower probability of improvement of 24-h BP (odds ratio for 20-μmol l(-1) increase, 0.60; P=0.05) and higher probability of experiencing no BP decrease (OR, 1.66; P=0.01). In conclusion, BP responses to RDN include regression-to-the-mean and remain to be consolidated in randomized trials based on ambulatory BP monitoring. For now, RDN should remain the last resort in patients in whom all other ways to control BP failed, and it must be cautiously used in patients with renal impairment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Higher nighttime blood pressure (BP) and the loss of nocturnal dipping of BP are associated with an increased risk for cardiovascular events. However, the determinants of the loss of nocturnal BP dipping are only beginning to be understood. We investigated whether different indicators of physical activity were associated with the loss of nocturnal dipping of BP. METHODS: We conducted a cross-sectional study of 103 patients referred for 24-hour ambulatory monitoring of BP. We measured these patients' step count (SC), active energy expenditure (AEE), and total energy expenditure simultaneously, using actigraphs. RESULTS: In our study population of 103 patients, most of whom were hypertensive, SC and AEE were associated with nighttime systolic BP in univariate (SC, r = -0.28, P < 0.01; AEE, r = -0.20, P = 0.046) and multivariate linear regression analyses (SC, coefficient beta = -5.37, P < 0.001; AEE, coefficient beta = -0.24, P < 0.01). Step count was associated with both systolic (r = 0.23, P = 0.018) and diastolic (r = 0.20, P = 0.045) BP dipping. Nighttime systolic BP decreased progressively across the categories of sedentary, moderately active, and active participants (125mm Hg, 116mm Hg, 112mm Hg, respectively; P = 0.002). The degree of BP dipping of BP increased progressively across the same three categories of activity (respectively 8.9%, 14.6%, and 18.6%, P = 0.002, for systolic BP and respectively 12.8%, 18.1%, and 22.2%, P = 0.006, for diastolic BP). CONCLUSIONS: Step count is continuously associated with nighttime systolic BP and with the degree of BP dipping independently of 24-hour mean BP. The combined use of an actigraph for measuring indicators of physical activity and a device for 24-hour measurement of ambulatory BP may help identify patients at increased risk for cardiovascular events in whom increased physical activity toward higher target levels may be recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a consensus meeting on ABPM in Milan in 2011 that the 34 attendees should prepare a comprehensive position paper on the scientific evidence for ABPM.This position paper considers the historical background, the advantages and limitations of ABPM, the threshold levels for practice, and the cost-effectiveness of the technique. It examines the need for selecting an appropriate device, the accuracy of devices, the additional information and indices that ABPM devices may provide, and the software requirements.At a practical level, the paper details the requirements for using ABPM in clinical practice, editing considerations, the number of measurements required, and the circumstances, such as obesity and arrhythmias, when particular care needs to be taken when using ABPM.The clinical indications for ABPM, among which white-coat phenomena, masked hypertension, and nocturnal hypertension appear to be prominent, are outlined in detail along with special considerations that apply in certain clinical circumstances, such as childhood, the elderly and pregnancy, and in cardiovascular illness, examples being stroke and chronic renal disease, and the place of home measurement of blood pressure in relation to ABPM is appraised.The role of ABPM in research circumstances, such as pharmacological trials and in the prediction of outcome in epidemiological studies is examined and finally the implementation of ABPM in practice is considered in relation to the issue of reimbursement in different countries, the provision of the technique by primary care practices, hospital clinics and pharmacies, and the growing role of registries of ABPM in many countries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background. In children, waist-for-height ratio (WHtR) has been proposed to identify subjects at higher risk of cardiovascular diseases. The utility of WHtR to identify children with elevated blood pressure (BP) is unclear. Design. Cross-sectional population-based study of schoolchildren. Methods. Weight, height, waist circumference and BP were measured in all sixth-grade schoolchildren of the canton de Vaud (Switzerland) in 2005/06. WHtR was computed as waist [cm]/height [cm]. Elevated BP was defined according to sex-, age- and height-specific US reference data. The area under the receiver operating characteristic curve (AUC) statistic was computed to compare the ability of body mass index (BMI) z-score and WHtR, alone or in combination, to identify children with elevated BP. Results. 5207 children participated (76% response) [2621 boys, 2586 girls; mean (± SD) age, 12.3 ± 0.5 years; range: 10.1-14.9]. The prevalence of elevated BP was 11%. Mean WHtR was 0.44 ± 0.05 (range: 0.29- 0.77) and 11% had high WHtR (> 0.5). BMI z-score and WHtR were strongly correlated (Spearman correlation coefficient r = 0.76). Both indices were positively associated with elevated BP. AUCs for elevated BP was relatively low for BMI z-score (0.62) or for WHtR (0.62), and was not substantially improved when both indices were considered together (0.63). Conclusions. The ability of BMI z-score or WHtR to identify children aged 10-14 with elevated BP was weak. Adding WHtR did not confer additional discriminative power to BMI alone. These findings do not support the measurement of WHtR in addition to BMI to identify children with elevated BP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Prevalence of hypertension in HIV infection is high, and information on blood pressure control in HIV-infected individuals is insufficient. We modeled blood pressure over time and the risk of cardiovascular events in hypertensive HIV-infected individuals. METHODS: All patients from the Swiss HIV Cohort Study with confirmed hypertension (systolic or diastolic blood pressure above 139 or 89 mm Hg on 2 consecutive visits and presence of at least 1 additional cardiovascular risk factor) between April 1, 2000 and March 31, 2011 were included. Patients with previous cardiovascular events, already on antihypertensive drugs, and pregnant women were excluded. Change in blood pressure over time was modeled using linear mixed models with repeated measurement. RESULTS: Hypertension was diagnosed in 2595 of 10,361 eligible patients. Of those, 869 initiated antihypertensive treatment. For patients treated for hypertension, we found a mean (95% confidence interval) decrease in systolic and diastolic blood pressure of -0.82 (-1.06 to -0.58) mm Hg and -0.89 (-1.05 to -0.73) mm Hg/yr, respectively. Factors associated with a decline in systolic blood pressure were baseline blood pressure, presence of chronic kidney disease, cardiovascular events, and the typical risk factors for cardiovascular disease. In patients with hypertension, increase in systolic blood pressure [(hazard ratio 1.18 (1.06 to 1.32) per 10 mm Hg increase], total cholesterol, smoking, age, and cumulative exposure to protease inhibitor-based and triple nucleoside regimens were associated with cardiovascular events. CONCLUSIONS: Insufficient control of hypertension was associated with increased risk of cardiovascular events indicating the need for improved management of hypertension in HIV-infected individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new respiratory impedance estimator to minimize the error due to breathing. Its practical reliability was evaluated in a simulation using realistic signals. These signals were generated by superposing pressure and flow records obtained in two conditions: 1) when applying forced oscillation to a resistance- inertance- elastance (RIE) mechanical model; 2) when healthy subjects breathed through the unexcited forced oscillation generator. Impedances computed (4-32 Hz) from the simulated signals with the new estimator resulted in a mean value which was scarcely biased by the added breathing (errors less than 1 percent in the mean R, I , and E ) and had a small variability (coefficients of variation of R, I, and E of 1.3, 3.5, and 9.6 percent, respectively). Our results suggest that the proposed estimator reduces the error in measurement of respiratory impedance without appreciable extracomputational cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed.¦METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy.¦RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months.¦CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Screening of elevated blood pressure (BP) in children has been advocated to early identify hypertension. However, identification of children with sustained elevated BP is challenging due to the high BP variability. The value of an elevated BP measure during childhood and adolescence for the prediction of future elevated BP is not well described. Objectives: We assessed the positive (PPV) and negative (NPV) predictive value of high BP for sustained elevated BP in cohorts of children of the Seychelles, a rapidly developing island state in the African region. Methods: Serial school-based surveys of weight, height, and BP were conducted yearly between 1998-2006 among all students of the country in four school grades (kindergarten [G0, mean age (SD): 5.5 (0.4) yr], G4 [9.2 (0.4) yr], G7 [12.5 (0.4) yr] and G10 (15.6 (0.5) yr]. We constituted three cohorts of children examined twice at 3-4 years interval: 4,557 children examined at G0 and G4, 6,198 at G4 and G7, and 6,094 at G7 and G10. The same automated BP measurement devices were used throughout the study. BP was measured twice at each exam and averaged. Obesity and elevated BP were defined using the CDC (BMI_95th sex-, and age-specific percentile) and the NHBPEP criteria (BP_95th sex-, age-, and height specific percentile), respectively. Results: Prevalence of obesity was 6.1% at G0, 7.1% at G4, 7.5% at G7, and 6.5% at G10. Prevalence of elevated BP was 10.2% at G0, 9.9% at G4, 7.1% at G7, and 8.7% at G10. Among children with elevated BP at initial exam, the PPV of keeping elevated BP was low but increased with age: 13% between G0 and G4, 19% between G4 and G7, and 27% between G7 and G10. Among obese children with elevated BP, the PPV was higher: 33%, 35% and 39% respectively. Overall, the probability for children with normal BP to remain in that category 3-4 years later (NPV) was 92%, 95%, and 93%, respectively. By comparison, the PPV for children initially obese to remain obese was much higher at 71%, 71%, and 62% (G7-G10), respectively. The NPV (i.e. the probability of remaining at normal weight) was 94%, 96%, and 98%, respectively. Conclusion: During childhood and adolescence, having an elevated BP at one occasion is a weak predictor of sustained elevated BP 3-4 years later. In obese children, it is a better predictor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient &gt; or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.