973 resultados para Potential detection
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Milk is considered a nutritious food because it contains several important nutrients including proteins and vitamins. Conversely, it can be a vehicle for several pathogenic bacteria such as Staphylococcus aureus. This study aimed to analyze the frequency of genes encoding the staphylococcal enterotoxins (SEs) SEA, SEB, SEC, SED, SEE, SEG, SEH, SEI and SEJ in S. aureus strains isolated from raw or pasteurized bovine milk. S. aureus was found in 38 (70.4%) out of 54 raw milk samples at concentrations of up to 8.9 X 10(5) CFU/ml. This microorganism was present in eight samples of pasteurized milk before the expiration date and in 11 samples analyzed on the expiration date. of the 57 strains studied, 68.4% were positive for one or more genes encoding the enterotoxins, and 12 different genotypes were identified. The gene coding for enterotoxin A, sea, was the most frequent ( 16 strains, 41%), followed by sec (8 strains, 20.5%), sed (5 strains, 12.8%). seb (3 strains. 7.7%) and see (2 strains, 5.1%). Among the genes encoding the other enterotoxins, seg was the most frequently observed (11 strains. 28.2%), followed by sei (10 strains) and seh and sej (3 strains each). With the recent identification of new SEs, the perceived frequency of enterotoxigenic strains has increased. suggesting that the pathogenic potential of staphylococci may be higher than previously thoughts however, further studies are required to assess the expression of these new SEs by S. aureus. and their impact in foodborne disease. The quality of Brazilian milk is still low. and efforts from the government and the entire productive chain are required to attain consumer safety. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Conjugated polymers have been subject of great interest in the recent literature from both fundamental point of view and applied science perspective. Among the several types of conjugated polymers used in recent investigations, polythiophene and its derivatives have attracted considerable attention over the past 20 years due to their high mobility and other remarkable solid-state properties. They have potential applications in many fields, such as microelectronic devices, catalysts, organic field-effect transistors, chemical sensors, and biosensors. They have been studied as gas and volatile organic compounds (VOCs) sensors using different principles or transduction techniques, such as optical absorption, conductivity, and capacitance measurements. In this work, we report on the fabrication of gas sensors based on a conducting polymer on an interdigitated gold electrode. We use as active layer of the sensor a polythiophene derivative: poly (3-hexylthiophene) (P3HT) and analyzed its conductivity as response for exposure to dynamic flow of saturated vapors of six VOCs [n-hexane, toluene, chloroform, dichloromethane, methanol, and tetrahydrofuran (THE)]. Different responses were obtained upon exposure to all VOCs, THF gave the higher response while methanol the lower response. The influence of moisture on the measurements was also evaluated. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Procion red HE-3B (RR120) is an example of dye currently used in affinity purification. A method is described for determining trace amounts of RR120 dye contaminant in human serum albumin by cathodic stripping voltammetry. The method is based on a measure of a well-defined peak at -0.58 V, obtained when samples of HSA protein (0.01-2% w/v) containing dye concentrations are submitted to a heating time of 330 min at 80degreesC in NaOH, pH 12.0 and the samples are removed to a solution containing Britton-Robinson buffer, pH 4.0. Using an optimum accumulation potential and tune of 0 V and 240 s, respectively, linear calibration curves were obtained from 1.0 X 10(-9) to 1.0 X 10(-8) mol 1(-1) for RR120 dye. Leakage/hydrolysis of reactive red 120 from an agarose support (e.g. at pH 2 or 12) can also be conveniently determined at very low levels (sub-mug ml(-1)) by means of cathodic stripping voltammetry, which involves adsorptive accumulation of the dye onto the hanging mercury-drop electrode. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
Toxocara vitulorum, a parasite of the small intestine of cattle and water buffaloes, is mainly acquired by calves via the colostrum/milk from infected cows. To understand the development of immune responses in calves, antibody levels to a soluble extract antigen (Ex) from T. vitulorum infective larvae were measured by an indirect ELISA with sera of 15 buffalo calves, which were sampled every 15 days for the first 180 days after birth and 9 buffalo cows during the perinatal period. From all serum samples examined during the first 180 days, antibody level was lowest and highest in calves at 1 day of age before and after suckling colostrum, respectively, suggesting that the origin of antibodies was the colostrum. Immediately after birth, antibody levels in suckled calves remained at high levels until day 15, began to decrease to lower levels between 15 and 30 days and remained relatively stable until 120 days. By comparing the immune responses of these animals with their parasitological status it was considered possible to determine if passively acquired or actively produced antibodies provided protection against the infection. High numbers of T. vitulorum eggs in the feces between 30 and 60 days indicated that passively acquired antibodies did not provide protection against the infection, at least during these first days, and the maximum fecal egg counts during 30-45 days were coincident with decreased antibody levels. Between 60 and 120 days, when serum antibodies were detected at reduced, but stable levels, adult nematodes were expelled from the intestines and no more T. vitulorum eggs were found, suggesting development of acquired resistance. However, the potential and functional protective role of the antibodies against T. vitulorum infection and the process of self-cure requires further investigation. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
In view of the importance of venereal transmission of bovine leptospirosis, the objective of the present study was to apply the polymerase chain reaction (PCR) to 26 serovars of Leptospira interrogans, L. borgpetersenii, L. santarosai, L. noguchii and L. biflexa, to determine the detection threshold in semen samples and to evaluate the possibility of differentiation among serovars using 19 restriction endonucleases. The results showed that all serovars were amplified and the detection threshold in semen samples of a bull was 100 bacteria/ml. Using endonucleases we could classify the 26 serovars into eight groups. The present results show that PCR is a method of great potential for the detection of Leptospira spp, at bovine artificial insemination centers. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Protein A containing Staphylococcus aureus was used to develop a coagglutination (COA) test for the detection and typing of foot and mouth disease virus (FMDV) O, A and C serotypes in infected cells and tissues. Different batches and amounts of guinea pig anti-FMDV sera were assessed to optimize the preparation of COA conjugates. The sensitivity and specificity of the COA Test for the detection of FMDV O, A and C serotypes and heterologous viruses was also characterized. Comparison between the COA Test and complement fixation test for the detection and typing of FMDV obtained from extracts of tongue epithelial tissues from infected cattle revealed high agreement in the results and indicated a potential application of the COA Test for the direct diagnosis of viruses.
Resumo:
A high performance liquid chromatography ( HPLC) method with electrochemical detection (ED) was developed for the determination of benzidine, 3,3-dimethylbenzidine, o-toluidine and 3,3-dichlorobenzidine in the wastewater of the textile industry. The aromatic amines were eluted on a reversed phase column Shimadzu Shimpack C-18 using acetonitrile + ammonium acetate (1 x 10(-4) mol L-1) at a ratio 46: 54 v/v as mobile phase, pumped at a flow rate of 1.0 mL min(-1). The electrochemical oxidation of the aromatic amines exhibits well-defined peaks at a potential range of +0.45 to +0.78 V on a glassy carbon electrode. Optimum working potentials for amperometric detection were from 0.70 V to +1.0 V vs. Ag/AgCl. Analytical curves for all the aromatic amines studied using the best experimental conditions present linear relationship from 1 x 10(-8) mol L-1 to 1.5 x 10(-5) mol L-1, r = 0.99965, n = 15. Detection limits of 4.5 nM (benzidine), 1.94 nM (o-toluidine), 7.69 nM (3,3-dimethylbenzidine), and 5.15 nM (3,3-dichlorobenzidine) were achieved, respectively. The detection limits were around 10 times lower than that verified for HPLC with ultra violet detection. The applicability of the method was demonstrated by the determination of benzidine in wastewater from the textile industry dealing with an azo dye processing plant.
Resumo:
A competitive enzyme-linked immunosorbent assay (ELISA) method for carbaryl quantitation in crop extracts was validated by liquid chromatography (LC) with diode array detection (DAD). For this purpose, six crops (banana, carrot, green bean, orange, peach and potato) were chosen for recovery and reproducibility studies. The general sample preparation included extraction with methanol followed by liquid-liquid partitioning and clean-up on Celite-charcoal adsorbent column of the vegetable extracts. ELISA samples consisted of a diluted LC extract in assay phosphate buffer (pH 7.5). The potential effect of methanol in these samples was evaluated. It was observed that a maximum content of 10% methanol present in the assay buffer could be tolerated without expressive losses in the ELISA performance. Under these conditions, a IC50 similar to 1.48 mu g l(-1) was obtained. A minimum matrix effect with a 1:50 dilution of the methanolic extracts in assay buffer was noticed, except for green bean samples that inhibited completely the assay. For the vegetable extracts, the ELISA sensitivities varied from 3.9 to 5.7 mu g l(-1), and good recoveries (82-96%) with R.S.D.s ranging from 5.7 to 12.1% were found. An excellent correlation between the LC-DAD and ELISA techniques was obtained. The confirmation of the carbaryl in less concentrated samples was achieved by LC-mass spectrometry interfaced with atmospheric pressure chemical ionisation. The [M + H](+)= 202 and [M + H-57](+)=145 ions, equivalent to the protonated molecular and l-naphthol ions, respectively, were used to carbaryl identification in these samples. (C) 1998 Elsevier B.V. B.V. All rights reserved.
Resumo:
A new methodology was developed for analysis of aldehydes and ketones in fuel ethanol by high-performance liquid chromatography (HPLC) coupled to electrochemical detection. The electrochemical oxidation of 5-hydroxymetkylfurfural, 2-furfuraldehyde, butyraldehyde, acetone and methyl ethyl ketone derivatized with 2,4-dinitrophenylhydrazine (DNPH) at glassy carbon electrode present a well defined wave at +0.94 V; +0.99 V; +1.29 V; +1.15 V and +1.18 V, respectively which are the basis for its determination on electrochemical defector. The carbonyl compounds derivatized were separated by a reverse-phase column under isocratic conditions with a mobile phase containing a binary mixture of methanol /LiClO4(aq) at a concentration of 1.0 x 10(-3) mol L-1 (80:20 v/v) and a flow-rate of 1.1 mL min(-1). The optimum potential for the electrochemical detection of aldehydes-DNPH and ketones-DNPH was +1.0 V vs. Ag/AgCl. The analytical curve of aldehydes-DNPH and ketones-DNPH presented linearity over the range 5.0 to 400.0 ng mL(-1), with detection limits of 1.7 to 2.0 ng mL(-1) and quantification limits from 5.0 to 6.2 ng mL(-1), using injection volume of 20 mu L. The proposed methodology was simple, low time-consuming (15 min/analysis) and presented analytical recovery higher than 95%.