962 resultados para PCR Arrays
Resumo:
Nano-fibrillar arrays are fabricated using polystyrene materials. The average diameter of each fiber is about 300 nm. Experiments show that such a fibrillar surface possesses a relatively hydrophobic feature with a water contact angle of 142 degrees. Nanoscale friction properties are mainly focused on. It is found that the friction force of polystyrene nano-fibrillar surfaces is obviously enhanced in contrast to polystyrene smooth surfaces. The apparent coefficient of friction increases with the applied load, but is independent of the scanning speed. An interesting observation is that the friction force increases almost linearly with the real contact area, which abides by the fundamental Bowden-Tabor law of nano-scale friction.
Resumo:
A method is developed to calculate the settling speed of dilute arrays of spheres for the three cases of: I, a random array of freely moving particles; II, a random array of rigidly held particles; and III, a cubic array of particles. The basic idea of the technique is to give a formal representation for the solution and then manipulate this representation in a straightforward manner to obtain the result. For infinite arrays of spheres, our results agree with the results previously found by other authors, and the analysis here appears to be simpler. This method is able to obtain more terms in the answer than was possible by Saffman's unified treatment for point particles. Some results for arbitrary two sphere distributions are presented, and an analysis of the wall effect for particles settling in a tube is given. It is expected that the method presented here can be generalized to solve other types of problems.
Resumo:
Galaxy clusters are the largest gravitationally bound objects in the observable universe, and they are formed from the largest perturbations of the primordial matter power spectrum. During initial cluster collapse, matter is accelerated to supersonic velocities, and the baryonic component is heated as it passes through accretion shocks. This process stabilizes when the pressure of the bound matter prevents further gravitational collapse. Galaxy clusters are useful cosmological probes, because their formation progressively freezes out at the epoch when dark energy begins to dominate the expansion and energy density of the universe. A diverse set of observables, from radio through X-ray wavelengths, are sourced from galaxy clusters, and this is useful for self-calibration. The distributions of these observables trace a cluster's dark matter halo, which represents more than 80% of the cluster's gravitational potential. One such observable is the Sunyaev-Zel'dovich effect (SZE), which results when the ionized intercluster medium blueshifts the cosmic microwave background via Compton scattering. Great technical advances in the last several decades have made regular observation of the SZE possible. Resolved SZE science, such as is explored in this analysis, has benefitted from the construction of large-format camera arrays consisting of highly sensitive millimeter-wave detectors, such as Bolocam. Bolocam is a submillimeter camera, sensitive to 140 GHz and 268 GHz radiation, located at one of the best observing sites in the world: the Caltech Submillimeter Observatory on Mauna Kea in Hawaii. Bolocam fielded 144 of the original spider web NTD bolometers used in an entire generation of ground-based, balloon-borne, and satellite-borne millimeter wave instrumention. Over approximately six years, our group at Caltech has developed a mature galaxy cluster observational program with Bolocam. This thesis describes the construction of the instrument's full cluster catalog: BOXSZ. Using this catalog, I have scaled the Bolocam SZE measurements with X-ray mass approximations in an effort to characterize the SZE signal as a viable mass probe for cosmology. This work has confirmed the SZE to be a low-scatter tracer of cluster mass. The analysis has also revealed how sensitive the SZE-mass scaling is to small biases in the adopted mass approximation. Future Bolocam analysis efforts are set on resolving these discrepancies by approximating cluster mass jointly with different observational probes.
Resumo:
DNA in canned tuna is degraded into short fragments of a rew hundred base pairs. The polymerase chain reaction (PCR) was used to amplify short sequences of mitochondrial DNA, which were denatured and analysed by polyacrylamide gel electrophoresis (native PAGE) for detection of single strand conformation polymorphisms. Species specific patterns of DNA bands were obtained for a number of tuna and bonito species. DE: In Thunfischkonserven liegt die DNA in Form kurzkettiger Fragmente von wenigen Hundert Basenpaaren Länge vor. Mit Hilfe der Polymerase-Kettenreaktion (PCR) wurden kurze Sequenzen der mitochondrialen DNA vervielfältigt. Anschließend wurde die gebildete DNA in Einzelsträngen überführt, die durch eine native Polyacrylamidgel-Elektrophorese (PAGE) aufgetrennt wurde. Für eine Reihe von Thunfischen und Boniten ergaben die Einzelstränge artspezifische Bandenmuster, die auf unterschiedliche Konformationen der DNA-Stränge der einzelnen Fischarten zurückzuführen sind.
Resumo:
Uniform arrays of periodic nanoparticles with 80-nm period are formed on 6H-SiC crystal irradiated by circularly polarized 400-nm femtosecond laser pulses. In order to understand the formation mechanism, the morphology evolvement as a function of laser pulse energy and number is studied. Periodic nanoripples are also formed on the sample surface irradiated by linearly polarized 400-, 510- and 800-nm femtosecond laser pulses. All these results support well the mechanism that second-harmonic generation plays an important role in the formation of periodic nanostructures.
Resumo:
Fundamental studies of magnetic alignment of highly anisotropic mesostructures can enable the clean-room-free fabrication of flexible, array-based solar and electronic devices, in which preferential orientation of nano- or microwire-type objects is desired. In this study, ensembles of 100 micron long Si microwires with ferromagnetic Ni and Co coatings are oriented vertically in the presence of magnetic fields. The degree of vertical alignment and threshold field strength depend on geometric factors, such as microwire length and ferromagnetic coating thickness, as well as interfacial interactions, which are modulated by varying solvent and substrate surface chemistry. Microwire ensembles with vertical alignment over 97% within 10 degrees of normal, as measured by X-ray diffraction, are achieved over square cm scale areas and set into flexible polymer films. A force balance model has been developed as a predictive tool for magnetic alignment, incorporating magnetic torque and empirically derived surface adhesion parameters. As supported by these calculations, microwires are shown to detach from the surface and align vertically in the presence of magnetic fields on the order of 100 gauss. Microwires aligned in this manner are set into a polydimethylsiloxane film where they retain their vertical alignment after the field has been removed and can subsequently be used as a flexible solar absorber layer. Finally, these microwires arrays can be protected for use in electrochemical cells by the conformal deposition of a graphene layer.
Resumo:
[ES]El sistema PAMELA III, con sus correspondientes phased arrays, se diseñó para la detección de daños en aeronaves mediante la tecnología SHM (structural health monitoring). Sin embargo, según los estudios del profesor Tadeusz Stepinski, la distribución de los piezoélectricos utilizada en estos phase arrays producen interferencias. Por ello, este proyecto se basa en el diseño de cuatro phased arrays diferentes, utilizando una de las distribuciones de piezoélectricos estudiada por el profesor Tadeusz. La distribución utilizada es la de cross-shaped (en forma de cruz), con lo que se consigue disminuir las interferencias producidas en los antiguos phased arrays. Además, se ha producido un diseño que es compatible tanto con PAMELA III, como con una futura actualización a PAMELA IV. Con lo que se ha conseguido que se pueda aumentar el tamaño de almacenamiento de la memoria utilizada cambiando la tecnología 1-wire por la de I2C, que sería utilizada solo en el sistema PAMELA IV. Aparte del diseño de los PCBs, también se han diseñado unas piezas de plástico que aportan rigidez a los phased arrays y además, hace que la parte inferior de la tarjeta quede toda a la misma altura y no sobresalgan los piezoélectricos, con lo que aumentará la facilidad de instalación.
Resumo:
The Lau cavity is the self-imaging cavity with a phase corrector under the Lau reimaging condition. The author proposes the use of the Lau cavity to utilize both the Talbot and the Lau effects for phase locking one-dimensional and two-dimensional diode-laser arrays into a single-lobe coherent beam. Analyses on the self-reproducing of a coherent lasing field and the reimaging of initial incoherent radiation are given.
Resumo:
Recent advances in our knowledge of the genetic structure of human caliciviruses (HuCVs) and small round-structured viruses (SRSVs) have led to the development of polymerase chain reaction (PCR)-based molecular tests specific for these viruses. These methods have been developed to detect a number of human pathogenic viruses in environmental samples including water, sewage and shellfish. HuCVs and SRSVs are not culturable, and no animal model is currently available. Therefore there is no convenient method of preparing viruses for study or for reagent production. One problem facing those attempting to use PCR-based methods for the detection of HuCVs and SRSVs is the lack of a suitable positive control substrate. This is particularly important when screening complex samples in which the levels of inhibitors present may significantly interfere with amplificiation. Regions within the RNA polymerase regions of two genetically distinct human caliciviruses have been amplified and used to produce recombinant baculoviruses which express RNA corresponding to the calicivirus polymerase. This RNA is being investigated as a positive control substrate for PCR testing, using current diagnostic primer sets. Recombinant baculovirus technology will enable efficient and cost-effective production of large quantities of positive control RNA with a specific known genotype. We consider the development of these systems as essential for successful screening and monitoring applications.
Resumo:
Recent theoretical and experimental results suggested that the silver superlens could be constructed through controlling silver thin film thickness and preparation conditions, and applied in subdiffraction-limited optical imaging and optical lithography. In this work, we report another significant application of silver superlens-ultrahigh density optical data storage. With the silver superlens the subdiffraction-limited pit arrays on an optical disk are dynamically read out and the carrier-to-noise ratio can reach 25 dB for the thin film thickness of 46 nm. The readout laser power and readout velocity have little effect on the carrier-to-noise ratio. Additionally, in our experiment the silver thin film thickness needs to be controlled in the range from 20 to 80 nm.
Resumo:
Fast moving arrays of periodic sub-diffraction-limit pits were dynamically read out via a silver thin film. The mechanism of the dynamic readout is analysed and discussed in detail, both experimentally and theoretically. The analysis and experiment show that, in the course of readout, surface plasmons can be excited at the silver/air interface by the focused laser beam and amplified by the silver thin film. The surface plasmons are transmitted into the substrate/silver interface with a large enhancement. The surface waves at the substrate/silver interface are scattered by the sinusoidal pits of sub-diffraction-limit size. The scattered waves are collected by a converging lens and guided into the detector for the readout.